Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Life (Basel) ; 13(2)2023 Jan 30.
Artigo em Inglês | MEDLINE | ID: mdl-36836741

RESUMO

INTRODUCTION: Intra-abdominal hypertension and the resulting abdominal compartment syndrome are serious complications of severely ill patients. Diagnosis requires an intra-abdominal pressure (IAP) measurement, which is currently cumbersome and underused. We aimed to test the accuracy of a novel continuous IAP monitor. METHODS: Adults having laparoscopic surgery and requiring urinary catheter intra-operatively were recruited to this single-arm validation study. IAP measurements using the novel monitor and a gold-standard foley manometer were compared. After anesthesia induction, a pneumoperitoneum was induced through a laparoscopic insufflator, and five randomly pre-defined pressures (between 5 and 25 mmHg) were achieved and simultaneously measured via both methods in each participant. Measurements were compared using Bland-Altman analysis. RESULTS: In total, 29 participants completed the study and provided 144 distinct pairs of pressure measurements that were analyzed. A positive correlation between the two methods was found (R2 = 0.93). There was good agreement between the methods, with a mean bias (95% CI) of -0.4 (-0.6, -0.1) mmHg and a standard deviation of 1.3 mmHg, which was statistically significant but of no clinical importance. The limits of agreement (where 95% of the differences are expected to fall) were -2.9 and 2.2 mmHg. The proportional error was statistically insignificant (p = 0.85), suggesting a constant agreement between the methods across the range of values tested. The percentage error was 10.7%. CONCLUSIONS: Continuous IAP measurements using the novel monitor performed well in the clinical setup of controlled intra-abdominal hypertension across the evaluated range of pressures. Further studies should expand the range to more pathological values.

2.
Eur J Anaesthesiol ; 39(1): 50-57, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-33852498

RESUMO

BACKGROUND: Epidural fentanyl doses above 100 µg have been shown, using the paracetamol absorption test, to reduce gastric emptying in fasted labouring women. OBJECTIVE: To investigate the effect of fentanyl dose on gastric emptying in nonfasted labouring women using gastric ultrasonography. DESIGN: A double-blinded randomised controlled study. SETTING: A tertiary medical centre in Tel Aviv, Israel between 30 July 2020 and 11 October 2020. PATIENTS: Eighty labouring women with cervical dilation 5 cm or less, at least 18 years age, at least 37 weeks gestation with a singleton pregnancy and cephalad foetus. INTERVENTIONS: Women randomised to high (>100 µg) or low (<100 µg) cumulative epidural fentanyl had ultrasound gastric content assessment, measuring antral cross-sectional area (CSA) at epidural placement and 2 h thereafter (T2  h). MAIN OUTCOME MEASURES: The primary outcome was CSA at T2  h comparing high-dose versus low-dose fentanyl. Secondary outcomes included change in CSA between baseline and T2  h. Sub-group analysis compared stomach content at T2  h according to baseline stomach content, empty (CSA <381 mm2) or full (CSA ≥381 mm2), and high-dose versus low-dose fentanyl. RESULTS: Data from 80 women were analysed; 63 had empty and 17 had full stomach at baseline. There was no significant difference in CSA at T2  h between high-dose, mean 335 ±â€ŠSD 133 mm2, versus low-dose fentanyl, mean 335 ±â€ŠSD 172 mm2, P = 0.991. Change in CSA baseline to T2  h was 46 ±â€ŠSD 149 mm2 for high and 49 ±â€ŠSD 163 mm2 for low-dose group, P = 0.931. The subgroup analysis according to baseline stomach content showed no statistically significant differences in CSA at T2  h. CONCLUSION: The CSA at T2  h was similar for women who received high-dose versus low-dose epidural fentanyl, measured by ultrasound, in our nonfasted labouring cohort. TRIAL REGISTRATION: Clinicaltrials.gov number: NCT04202887.


Assuntos
Analgesia Epidural , Analgesia Obstétrica , Anestesia Epidural , Trabalho de Parto , Método Duplo-Cego , Feminino , Fentanila , Esvaziamento Gástrico , Humanos , Gravidez , Ultrassonografia
3.
BMC Anesthesiol ; 20(1): 262, 2020 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-33050885

RESUMO

BACKGROUND: The Coronavirus infectious disease 2019 (COVID-19) brings anesthesiologists and intensive care physicians to the mainstay of clinical workload and healthcare managements' focus. There are approximately 900 anesthesiologists in Israel, working in non-private hospitals. This nationwide cross-sectional study evaluated the readiness and involvement of anesthesia departments in Israel in management of the COVID-19 pandemic. The impact on anesthesiologists' health, workload, and clinical practices were also evaluated. METHODS: An online questionnaire was distributed to all of anesthesia department chairs in Israel on April 14th. Each response was identifiable on the hospital level only. Informed consent was waived since no patient data were collected. RESULTS: Response rate was 100%. A decrease of at least 40% in operating-room activity was reported by two-thirds of the departments. Anesthesiologists are leading the treatment of COVID-19 patients in 19/28 (68%) Israeli hospitals. Israel Society of Anesthesiologists' recommendations regarding intubation of COVID-19 patients were strictly followed (intubations performed by the most experienced available physician, by rapid-sequence induction utilizing video-laryngoscopy, while minimizing the number of people in the room - about 90% compliance for each). Anesthesiologists in most departments use standard personal protective equipment when caring for COVID-19 patients, including N95 masks, face shields, and water-proof gowns. Only one anesthesiologist across Israel was diagnosed with COVID-19 (unknown source of transmission). All department chairs reported emerging opportunities that advance the anesthesia profession: implementation of new technologies and improvement in caregivers' clinical capabilities (68% each), purchase of new equipment (96%), and increase in research activity (36%). CONCLUSIONS: This nationwide cross-sectional study had a complete response rate and therefore well-represents the anesthesia practice in Israel. We found that Israeli anesthesia departments are generally highly involved in the health system efforts to cope with the COVID-19 pandemic. Anesthesia and airway management are performed in a remarkably comparable manner and with proper protection of caregivers. Ambulatory anesthesia activity has dramatically decreased, but many departments find opportunities for improvement even in these challenging times.


Assuntos
Serviço Hospitalar de Anestesia/organização & administração , Anestesiologistas/organização & administração , Anestesiologia/organização & administração , Infecções por Coronavirus/epidemiologia , Pneumonia Viral/epidemiologia , Manuseio das Vias Aéreas/métodos , Anestesia/métodos , COVID-19 , Estudos Transversais , Humanos , Intubação Intratraqueal/métodos , Israel/epidemiologia , Salas Cirúrgicas/organização & administração , Pandemias , Inquéritos e Questionários
4.
Bone Marrow Transplant ; 55(7): 1305-1316, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32433499

RESUMO

Graft versus host disease (GvHD) remains a limiting factor for successful hematopoietic stem cell transplantation (HSCT). T cells and antigen-presenting cells (APCs) are major components of the hematopoietic G-CSF mobilized peripheral blood cell (MPBC) graft. Here we show that a short incubation (2 h) of MPBCs with hexameric Fas ligand (FasL) selectively induces apoptosis of specific donor T cell subsets and APCs but not of CD34+ cells. FasL treatment preferentially induces apoptosis in mature T cell subsets which express high levels of Fas (CD95), such as T stem cell memory, T central memory, and T effector memory cells, as well as TH1 and TH17 cells. Anti-CD3/CD28 stimulated T cells derived from FasL-treated-MPBCs express lower levels of CD25 and secrete lower levels of IFN-γ as compared to control cells not treated with FasL. FasL treatment also induces apoptosis of transitional, naïve, memory and plasmablastoid B cells leading to a reduction in their numbers in the graft and following engraftment in transplanted mice. Most importantly, ex vivo treatment of MPBCs with FasL prior to transplant in conditioned NOD-scid IL2Rγnull (NSG) mice prevented GvHD while preserving graft versus leukemia (GvL) effects, and leading to robust stem cell engraftment.


Assuntos
Doença Enxerto-Hospedeiro , Transplante de Células-Tronco Hematopoéticas , Animais , Proteína Ligante Fas , Doença Enxerto-Hospedeiro/prevenção & controle , Ligantes , Camundongos , Camundongos Endogâmicos NOD , Células-Tronco
5.
Insect Sci ; 25(2): 309-316, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28028893

RESUMO

Ongoing climate change affects various aspects of an animal's life, with important effects on distribution range and phenology. The relationship between global warming and body size changes in mammals and birds has been widely studied, with most findings indicating a decline in body size over time. Nevertheless, little data exist on similar size change patterns of invertebrates in general and insects in particular, and it is unclear whether insects should decrease in size or not with climate warming. We measured over 4000 beetle specimens, belonging to 29 beetle species in 8 families, collected in Israel during the last 100 years. The sampled species are all herbivorous. We examined whether beetle body size had changed over the years, while also investigating the relationships between body size and annual temperature, precipitation, net primary productivity (NPP) at the collection site and collection month. None of the environmental variables, including the collection year, was correlated with the size of most of the studied beetle species, while there were strong interactions of all variables with species. Our results, though mostly negative, suggest that the effect of climate change on insect body size is species-specific and by no means a general macro-ecological rule. They also suggest that the intrapopulation variance in body size of insects collected as adults in the field is large enough to conceal intersite environmental effects on body size, such as the effect of temperature and NPP.


Assuntos
Tamanho Corporal , Mudança Climática , Besouros , Animais , Chuva
6.
PLoS One ; 9(1): e86131, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24465916

RESUMO

UNLABELLED: Circularly polarized light, rare in the animal kingdom, has thus far been documented in only a handful of animals. Using a rotating circular polarization (CP) analyzer we detected CP in linearly polarized light transmitted through epipelagic free living Sapphirina metallina copepods. Both left and right handedness of CP was detected, generated from specific organs of the animal's body, especially on the dorsal cephalosome and prosome. Such CP transmittance may be generated by phase retardance either in the muscle fibers or in the multilayer membrane structure found underneath the cuticle. Although the role, if any, played by circularly polarized light in Sapphirinidae has yet to be clarified, in other animals it was suggested to take part in mate choice, species recognition, and other forms of communication. HIGHLIGHTS: Planktonic Sapphirinidae copepods were found to circularly polarize the light passing through them. Circular polarization may be created by unique, multilayered features of the membrane structure found under their cuticle or by organized muscle fibers.


Assuntos
Copépodes/fisiologia , Luz , Animais , Copépodes/citologia , Copépodes/ultraestrutura , Microscopia , Processamento de Sinais Assistido por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...