Methods Cell Biol ; 147: 3-28, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30165961

RESUMO

Microfluidic technologies have become a standard tool in cell biological studies, offering unprecedented control of the chemical and physical environment of cells grown in microdevices, the possibility of multiplexing assays, as well as the capacity to monitor the behavior of single cells in real time while dynamically manipulating their growth medium. However, the properties of the materials employed for the fabrication of microchips that are compatible with live-cell imaging has limited the use of these techniques for a broad range of experiments. In particular, the strong absorption of a large panel of small molecules by these materials prevents the accurate delivery of compounds of interest. Here we describe a novel microsystem dedicated to live-cell imaging that (1) uses alternative materials devoid of absorptive properties, and (2) allows for dynamic in-chip control of sample temperature. Based on a proof-of-concept design that we have routinely used with non-adherent fission yeast cells, this chapter details all the steps for the fabrication and utilization of these microdevices.


Assuntos
Sistemas de Liberação de Medicamentos , Técnicas Analíticas Microfluídicas/métodos , Temperatura , Alcenos/química , Animais , Calibragem , Sobrevivência Celular , Imageamento Tridimensional , Polímeros/química
2.
BMC Cell Biol ; 19(1): 8, 2018 06 20.
Artigo em Inglês | MEDLINE | ID: mdl-29925307

RESUMO

BACKGROUND: Real-time monitoring of cellular responses to dynamic changes in their environment or to specific treatments has become central to cell biology. However, when coupled to live-cell imaging, such strategies are difficult to implement with precision and high time resolution, and the simultaneous alteration of multiple parameters is a major challenge. Recently, microfluidics has provided powerful solutions for such analyses, bringing an unprecedented level of control over the conditions and the medium in which cells under microscopic observation are grown. However, such technologies have remained under-exploited, largely as a result of the complexity associated with microfabrication procedures. RESULTS: In this study, we have developed simple but powerful microfluidic devices dedicated to live-cell imaging. These microsystems take advantage of a robust elastomer that is readily available to researchers and that presents excellent bonding properties, in particular to microscopy-grade glass coverslips. Importantly, the chips are easy-to-build without sophisticated equipment, and they are compatible with the integration of complex, customized fluidic networks as well as with the multiplexing of independent assays on a single device. We show that the chips are re-usable, a significant advantage for the popularization of microfluidics in cell biology. Moreover, we demonstrate that they allow for the dynamic, accurate and simultaneous control of multiple parameters of the cellular environment. CONCLUSIONS: While they do not possess all the features of the microdevices that are built using complex and costly procedures, the simplicity and versatility of the chips that we have developed make them an attractive alternative for a range of applications. The emergence of such devices, which can be fabricated and used by any laboratory, will provide the possibility for a larger number of research teams to take full advantage of these new methods for investigating cell biology.


Assuntos
Imageamento Tridimensional , Microfluídica/métodos , Sobrevivência Celular , Elastômeros/química , Fluorescência , Células HeLa , Humanos , Perfusão , Pressão , Reologia , Saccharomyces cerevisiae/metabolismo , Temperatura
3.
Open Biol ; 6(8)2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27512142

RESUMO

Monitoring cellular responses to changes in growth conditions and perturbation of targeted pathways is integral to the investigation of biological processes. However, manipulating cells and their environment during live-cell-imaging experiments still represents a major challenge. While the coupling of microfluidics with microscopy has emerged as a powerful solution to this problem, this approach remains severely underexploited. Indeed, most microdevices rely on the polymer polydimethylsiloxane (PDMS), which strongly absorbs a variety of molecules commonly used in cell biology. This effect of the microsystems on the cellular environment hampers our capacity to accurately modulate the composition of the medium and the concentration of specific compounds within the microchips, with implications for the reliability of these experiments. To overcome this critical issue, we developed new PDMS-free microdevices dedicated to live-cell imaging that show no interference with small molecules. They also integrate a module for maintaining precise sample temperature both above and below ambient as well as for rapid temperature shifts. Importantly, changes in medium composition and temperature can be efficiently achieved within the chips while recording cell behaviour by microscopy. Compatible with different model systems, our platforms provide a versatile solution for the dynamic regulation of the cellular environment during live-cell imaging.


Assuntos
Desenho de Equipamento/métodos , Microfluídica/instrumentação , Células HeLa/ultraestrutura , Humanos , Reprodutibilidade dos Testes , Temperatura , Leveduras/ultraestrutura