Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 193: 110627, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36584412

RESUMO

Computed tomography is widely used for planar imaging. Previous studies showed that CR systems involve higher patient radiation doses compared to digital systems. Therefore, assessing the patient's dose and CR system performance is necessary to ensure that patients received minimal dose with the highest possible image quality. The study was performed at three medical diagnostic centers in Sudan: Medical Corps Hospital (MCH), Advance Diagnostic Center (ADC), and Advance Medical Center (AMC). The following tools were used in this study: Tape measure, Adhesive tape, 1.5 mm copper filtration (>10 × 10 cm), TO 20 threshold contrast test object, Resolution test object (e.g., Huttner 18), MI geometry test object or lead ruler, Contact mish, Piranha (semiconductor detector), Small lead or copper block (∼5 × 5 cm), and Steel ruler, to do a different type of tests (Dark Noise, Erasure cycle efficiency, Sensitivity Index calibration, Sensitivity Index consistency, Uniformity, Scaling errors, Blurring, Limiting spatial Resolution, Threshold, and Laser beam Function. Entrance surface air kerma (ESAK (mGy) was calculated from patient exposure parameters using DosCal software for three imaging modalities. A total of 199 patients were examined (112 chest X rays, 77 lumbar spine). The mean and standard deviation (sd) for patients ESAK (mGy) were 2.56 ± 0.1 mGy and 1.6 mGy for the Anteroposterior (AP) and lateral projections for the lumbar spine, respectively. The mean and sd for the patient's chest doses were 0.1 ± 0.01 for the chest X-ray procedures. The three medical diagnostic centers' CR system performance was evaluated and found that all of the three centers have good CR system functions. All the centers satisfy all the criteria of acceptable visual tests. CR's image quality and sensitivity were evaluated, and the CR image is good because it has good contrast and resolution. All the CR system available in the medical centers and upgraded from old X-ray systems to new systems, has been found to work well. The patient's doses were comparable for the chest X-ray procedures, while patients' doses from the lumbar spine showed variation up to 2 folds due to the variation in patients' weight and X-ray machine setting. Patients dose optimization is recommended to ensure the patients received a minimal dose while obtaining the diagnostic findings.


Assuntos
Cobre , Vértebras Lombares , Humanos , Doses de Radiação , Radiografia , Raios X
2.
Eur Radiol ; 27(3): 1012-1020, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27380902

RESUMO

OBJECTIVES: The purpose of this study was to investigate the ability of computed tomography texture analysis (CTTA) to provide additional prognostic information in patients with Hodgkin's lymphoma (HL) and high-grade non-Hodgkin's lymphoma (NHL). METHODS: This retrospective, pilot-study approved by the IRB comprised 45 lymphoma patients undergoing routine 18F-FDG-PET-CT. Progression-free survival (PFS) was determined from clinical follow-up (mean-duration: 40 months; range: 10-62 months). Non-contrast-enhanced low-dose CT images were submitted to CTTA comprising image filtration to highlight features of different sizes followed by histogram-analysis using kurtosis. Prognostic value of CTTA was compared to PET FDG-uptake value, tumour-stage, tumour-bulk, lymphoma-type, treatment-regime, and interim FDG-PET (iPET) status using Kaplan-Meier analysis. Cox regression analysis determined the independence of significantly prognostic imaging and clinical features. RESULTS: A total of 27 patients had aggressive NHL and 18 had HL. Mean PFS was 48.5 months. There was no significant difference in pre-treatment CTTA between the lymphoma sub-types. Kaplan-Meier analysis found pre-treatment CTTA (medium feature scale, p=0.010) and iPET status (p<0.001) to be significant predictors of PFS. Cox analysis revealed that an interaction between pre-treatment CTTA and iPET status was the only independent predictor of PFS (HR: 25.5, 95% CI: 5.4-120, p<0.001). Specifically, pre-treatment CTTA risk stratified patients with negative iPET. CONCLUSION: CTTA can potentially provide prognostic information complementary to iPET for patients with HL and aggressive NHL. KEY POINTS: • CT texture-analysis (CTTA) provides prognostic information complementary to interim FDG-PET in Lymphoma. • Pre-treatment CTTA and interim PET status were significant predictors of progression-free survival. • Patients with negative interim PET could be further stratified by pre-treatment CTTA. • Provide precision surveillance where additional imaging reserved for patients at greatest recurrence-risk. • Assists in risk-adapted treatment strategy based on interim PET and CTTA.


Assuntos
Fluordesoxiglucose F18 , Doença de Hodgkin/diagnóstico por imagem , Linfoma não Hodgkin/dietoterapia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Prognóstico , Compostos Radiofarmacêuticos , Reprodutibilidade dos Testes , Estudos Retrospectivos , Medição de Risco , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...