1.
Front Pediatr ; 11: 1213310, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37719452

RESUMO

Objective: The performance of automated control of inspired oxygen (A-FiO2) has been confirmed in dozens of studies but reports of routine use are limited. Broadly adopted in Poland, our aim is to share that experience. Methods: We used a prospectively planned observational study of the performance, general use patterns, unit practices, and problems with A-FiO2, based on a web registry of case reports, complemented by surveys of subjective impressions. Results: In 2019, a total of 92 A-FiO2 systems were in routine use in 38 centers. Of the 38 centers, 20 had agreed in 2013 to participate in the project. In these centers, A-FiO2 was applied in infants of all weights, but some centers restricted its use to weaning from oxygen and unstable infants. A cohort had reported their experience with each use (5/20 centers, 593 cases). A quarter of those infants were managed with a lower target range and three-quarters with alarms looser than European guidelines for manual SpO2 control. The perceived primary advantages of A-FiO2 were as follows: keeping the readings in the target range, reducing exposure to SpO2 extremes, reducing risk from nurse distraction, reducing workload, and reducing alarm fatigue. Practices did evolve with experience, including implementing changes in the alarm strategy, indications for use, and target range. The potential for over-reliance on automation was cited as a risk. There were a few reports of limited effectiveness (moderate 12/593 and poor 2/593). Conclusions: Automated oxygen control is broadly perceived by users as an improvement in controlling SpO2 with infrequent problems.

2.
Arch Dis Child Fetal Neonatal Ed ; 102(5): F395-F399, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28209638

RESUMO

OBJECTIVE: To evaluate the effect of implementing automated oxygen control as routine care in maintaining oxygen saturation (SpO2) within target range in preterm infants. METHODS: Infants <30 weeks gestation in Leiden University Medical Centre before and after the implementation of automated oxygen control were compared. The percentage of time spent with SpO2 within and outside the target range (90-95%) was calculated. SpO2 values were collected every minute and included for analysis when infants received extra oxygen. RESULTS: In a period of 9 months, 42 preterm infants (21 manual, 21 automated) were studied. In the automated period, the median (IQR) time spent with SpO2 within target range increased (manual vs automated: 48.4 (41.5-56.4)% vs 61.9 (48.5-72.3)%; p<0.01) and time SpO2 >95% decreased (41.9 (30.6-49.4)% vs 19.3 (11.5-24.5)%; p<0.001). The time SpO2<90% increased (8.6 (7.2-11.7)% vs 15.1 (14.0-21.1)%; p<0.0001), while SpO2<80% was similar (1.1 (0.4-1.7)% vs 0.9 (0.5-2.1)%; ns). CONCLUSIONS: During oxygen therapy, preterm infants spent more time within the SpO2 target range after implementation of automated oxygen control, with a significant reduction in hyperoxaemia, but not hypoxaemia.


Assuntos
Monitorização Fisiológica , Oximetria , Oxigênio/administração & dosagem , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Intubação Intratraqueal , Ventilação não Invasiva , Oxigênio/sangue , Oxigenoterapia , Estudos Prospectivos
3.
Pediatrics ; 98(6 Pt 1): 1058-61, 1996 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-8951253

RESUMO

OBJECTIVE: The association between high-frequency ventilation (HFV) and intraventricular hemorrhage (IVH) and periventricular leukomalacia (PVL) has been debated. PURPOSE: To determine if premature neonates treated with HFV are at greater risk for developing IVH and/or PVL than neonates treated with conventional ventilation, we completed a meta-analysis of all prospective randomized control trials comparing HFV and conventional ventilation in the management of respiratory distress syndrome. METHODS: The meta-analysis included nine studies comparing HFV and conventional ventilation in the management of preterm neonates. To summarize the data, we calculated the difference in absolute risk for IVH and PVL between neonates treated with HFV and those treated with standard ventilation. These differences were combined to determine an overall difference in the absolute risk and its confidence interval. We examined the effect of estimated gestational age, birth weight, surfactant, and age at study entry on the results. Because one trial (HIFI study) was much larger than the other studies, it dominated the analysis, so we evaluated the data with and without including data from the HIFI trial. RESULTS: The occurrences of IVH and PVL ranged from 14% to 47% and 5% to 16%, respectively. This variation may be explained by the difference in the populations of neonates treated. The meta-analysis showed that use of HFV was associated with an increased risk of PVL (odds ratio = 1.7 with a confidence interval of 1.06 to 2.74), but not IVH or severe (> or = grade 3) IVH. When the results of the HIFI study were excluded, there were no differences between HFV and conventional ventilation in the occurrence of IVH or PVL. CONCLUSIONS: The association between HFV and adverse neurologic outcomes is primarily influenced by the results of the HIFI trial. Meta-analysis of more recent studies does not confirm the findings of the HIFI trial and suggests that HFV is not associated with increased occurrence of IVH or PVL.


Assuntos
Hemorragia Cerebral/etiologia , Ventilação de Alta Frequência/efeitos adversos , Recém-Nascido Prematuro , Leucomalácia Periventricular/etiologia , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Ensaios Clínicos como Assunto , Idade Gestacional , Humanos , Recém-Nascido , Respiração Artificial