Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Curr Rheumatol Rev ; 14(1): 46-52, 2018 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-27894239

RESUMO

BACKGROUND: Biologic agents have contributed significantly to the management of patients with in rheumatoid arthritis (RA). A significant proportion of patients with RA still require arthroplasty procedures however. It is unclear whether these agents increase the risk of post operative infection after lower limb arthroplasty. METHOD: A literature search was performed for articles published over the last 10 years in the English language examining the association between anti-tumour necrosis factor inhibitors and the incidence of post operative infection in patients with RA undergoing hip and knee arthroplasty procedures. RESULTS: One large meta-analysis has been published suggesting a 2-fold increase in infection rates following orthopaedic surgery in patients receiving biological agents. When subgroup analysis of arthroplasty cases alone was performed the finding failed to reach significance. However, several further studies have demonstrated both an increased risk for surgical site infection with the use of biological agents and several conflicting articles argue the opposite. CONCLUSION: There is no current consensus on this topic. The safety of continuation of perioperative anti-TNF-α therapy in patients undergoing lower limb arthroplasty procedures is unclear. There is also little robust guidance from specialist rheumatologic societies. There is need for large scale multicentre randomised controlled trials to address this issue.


Assuntos
Antirreumáticos/efeitos adversos , Artrite Reumatoide/tratamento farmacológico , Artroplastia/efeitos adversos , Infecção da Ferida Cirúrgica/epidemiologia , Fatores Biológicos/efeitos adversos , Humanos
2.
Surgeon ; 7(4): 228-31, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19736890

RESUMO

Intellectual property rights protect innovations and their authors. This review describes the concepts of copyright and patent with their relative merits and drawbacks. An understanding of intellectual property rights is important for doctors to allow protection of their work but should not be at the expense of scientific progress.


Assuntos
Biotecnologia/legislação & jurisprudência , Propriedade Intelectual , Propriedade/legislação & jurisprudência , União Europeia
3.
Knee ; 15(1): 40-4, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17945500

RESUMO

Revision total knee arthroplasty using a second generation modular rotating hinge design was done on thirty two knees in 30 patients over an 8-year period. Twenty-nine knees in 29 patients were followed up for 4.5-11 years (mean, 58 months). Four prostheses failed and two patients had died and one patient was lost to followup. Indications for revision were recurrent sepsis (five knees), component failure (four knees), ligamentous instability (two knees), aseptic loosening (10 knees), fracture (six knees), and gross bone loss (five knees). Early results have demonstrated improvement in both the Knee Society knee and function Scores and range of movement. The Knee Society knee score improved from 26 preoperatively to 68 postoperatively. The function score improved from 27 preoperatively to 75 postoperatively. One patient had evidence of aseptic loosening on radiographs, and the patellofemoral complication rate was low at 6%. This short-term clinical and radiographic review has demonstrated encouraging results in the use of a custom-made second generation rotating hinge component when used in revision knee surgery.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Falha de Prótese , Adulto , Idoso , Feminino , Humanos , Articulação do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia , Reoperação , Terapia de Salvação
4.
J Bone Joint Surg Br ; 89(11): 1431-8, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17998177

RESUMO

We report an independent prospective review of the first 230 Birmingham hip resurfacings in 212 patients at a mean follow-up of five years (4 to 6). Two patients, one with a loose acetabular component and the other with suspected avascular necrosis of the femoral head, underwent revision. There were two deaths from unrelated causes and one patient was lost to follow-up. The survivorship with the worst-case scenario was 97.8% (95% confidence interval 95.8 to 99.5). The mean Harris hip score improved significantly (paired t-test, p < 0.05) from 62.54 (8 to 92) pre-operatively to 97.7 (61 to 100) at a mean of three years (2.1 to 4.3), then deteriorated slightly to a mean of 95.2 (47 to 100) at a mean of five years. The mean flexion improved from 91.5 degrees (25 degrees to 140 degrees) to 110.4 degrees (80 degrees to 145 degrees) at a mean of three years with no further improvement at five years (111.2 degrees; 70 degrees to 160 degrees). On radiological review at five years, one patient had a progressive lucent line around the acetabular component and six had progressive lucent lines around the femoral component. A total of 18 femoral components (8%) had migrated into varus and those with lucent lines present migrated a mean of 3.8 degrees (1.02 degrees to 6.54 degrees) more than the rest. Superolateral notching of the femoral neck and reactive sclerosis at the tip of the peg of the femoral component were associated with the presence of lucent lines (chi-squared test, p < 0.05), but not with migration of the femoral component, and are of unknown significance. Our results with the Birmingham hip resurfacing continue to be satisfactory at a mean follow-up of five years.


Assuntos
Artrite Reumatoide/cirurgia , Artroplastia de Quadril/métodos , Osteonecrose/cirurgia , Desenho de Prótese , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Artrite Reumatoide/diagnóstico por imagem , Artrite Reumatoide/reabilitação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Osteonecrose/diagnóstico por imagem , Cuidados Pós-Operatórios/métodos , Cuidados Pós-Operatórios/reabilitação , Estudos Prospectivos , Radiografia , Resultado do Tratamento
5.
J Bone Joint Surg Br ; 89(8): 1019-24, 2007 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-17785738

RESUMO

Narrowing of the femoral neck after resurfacing arthroplasty of the hip has been described previously in both cemented and uncemented hip resurfacing. The natural history of narrowing of the femoral neck is unknown. We retrospectively measured the diameter of the femoral neck in a series of 163 Birmingham hip resurfacings in 163 patients up to a maximum of six years after operation to determine the extent and progression of narrowing. There were 105 men and 58 women with a mean age of 52 years (18 to 82). At a mean follow-up of five years, the mean Harris hip score was 94.8 (47 to 100) and the mean flexion of the hip 112.5 degrees (80 degrees to 160 degrees ). There was some narrowing of the femoral neck in 77% (125) of the patients reviewed, and in 27.6% (45) the narrowing exceeded 10% of the diameter of the neck. A multiple logistic regression analysis showed a significant association (chi-squared test (derived from logistic regression) p = 0.01) of narrowing with female gender and a valgus femoral neck/shaft angle. There was no significant association between the range of movement, position or size of the component or radiological lucent lines and narrowing of the neck (chi-squared test; p = 0.10 (flexion), p = 0.08 (size of femoral component), p = 0.09 (size of acetabular component), p = 0.71 (femoral component angulation), p = 0.99 (lucent lines)). There was no significant difference between the diameter of the neck at a mean of three years (2.5 to 3.5) and that at five years (4.5 to 5.5), indicating that any change in the diameter of the neck had stabilised by three years (sign rank test, p = 0.60). We conclude that narrowing of the femoral neck which is found with the Birmingham hip resurfacing arthroplasty is in most cases associated with no adverse clinical or radiological outcome up to a maximum of six years after the initial operation.


Assuntos
Artroplastia de Quadril/efeitos adversos , Colo do Fêmur/diagnóstico por imagem , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antropometria , Artroplastia de Quadril/métodos , Feminino , Colo do Fêmur/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Análise de Regressão , Estudos Retrospectivos , Fatores Sexuais , Resultado do Tratamento
6.
Injury ; 36(12): 1416-20, 2005 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-16051240

RESUMO

A prospective clinical trial was performed to assess the suitability of a new type of sterilisable, user-friendly radiation protection glove. In a preliminary trial, we showed that the dominant hand of the primary operating orthopaedic surgeon receives the highest dose of radiation. During a 4-month period, 98 procedures were done requiring the use of an image intensifier. The doses of radiation to the dominant hand of the operating surgeon were reduced to less than the doses of radiation to the non-dominant hand. The glove was sterilisable, user-friendly and accepted by the majority of surgeons. It offers greater than 90% attenuation of X-rays and is superior to all other scatter gloves on the market.


Assuntos
Luvas Protetoras , Luvas Cirúrgicas , Exposição Ocupacional/prevenção & controle , Ortopedia , Proteção Radiológica/instrumentação , Humanos , Doenças Profissionais/prevenção & controle , Estudos Prospectivos , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Intensificação de Imagem Radiográfica , Espalhamento de Radiação , Dosimetria Termoluminescente
7.
Br J Sports Med ; 39(7): 444-7, 2005 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15976168

RESUMO

BACKGROUND: Mixed martial arts have rapidly succeeded boxing as the world's most popular full contact sport, and the incidence of injury is recognised to be high. OBJECTIVE: To assess qualitatively and quantitatively the potential risk for participants to sustain cervical spine and associated soft tissue injuries. METHODS: Four commonly performed manoeuvres with possible risks to the cervical spine were analysed with respect to their kinematics, and biomechanical models were constructed. RESULTS: Motion analysis of two manoeuvres revealed strong correlations with rear end motor vehicle impact injuries, and kinematics of the remaining two suggested a strong risk of injury. Mathematical models of the biomechanics showed that the forces involved are of the same order as those involved in whiplash injuries and of the same magnitude as compression injuries of the cervical spine. CONCLUSIONS: This study shows that there is a significant risk of whiplash injuries in this sport, and there are no safety regulations to address these concerns.


Assuntos
Vértebras Cervicais/lesões , Artes Marciais/lesões , Lesões do Pescoço/etiologia , Traumatismos em Chicotada/etiologia , Adulto , Fenômenos Biomecânicos , Humanos , Fatores de Risco
8.
Orthop Clin North Am ; 36(2): 187-93, ix, 2005 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15833456

RESUMO

Hip resurfacing arthroplasty is an old orthopedic concept that has undergone a resurgence of interest in the past decade. Because of the rapid increase in the number of procedures being performed, previously recognized complications have begun to recur. This article focuses on complications that are related to the hip resurfacing procedure such as femoral neck fractures, avascular necrosis, raised metal ion levels, and sound initial and durable long-term fixation of an all-metal monoblock cobalt/chrome acetabular component. Dislocation rates after resurfacing and other complications are briefly discussed.


Assuntos
Artroplastia de Quadril/efeitos adversos , Prótese de Quadril , Falha de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Artroplastia de Quadril/instrumentação , Artroplastia de Quadril/métodos , Segurança de Equipamentos , Feminino , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Necrose da Cabeça do Fêmur/cirurgia , Seguimentos , Fraturas do Quadril/diagnóstico por imagem , Fraturas do Quadril/cirurgia , Humanos , Masculino , Teste de Materiais , Metais , Osteoartrite do Quadril/diagnóstico por imagem , Osteoartrite do Quadril/cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Desenho de Prótese , Infecções Relacionadas à Prótese/epidemiologia , Radiografia , Reoperação
9.
J Bone Joint Surg Br ; 87(3): 324-9, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15773639

RESUMO

We describe the experience with the first consecutive 230 Birmingham hip resurfacings at our centre. At a mean follow-up of three years (25 to 52 months) survivorship was 99.14% with revision in one patient for a loose acetabular component and one death from unrelated causes. One patient developed a fracture of the femoral neck at six weeks which united unremarkably after a period of non-weight-bearing. The Harris hip score improved from a mean of 62.54 (8 to 92) to 97.74 (61 to 100). The mean flexion improved from 91.52 degrees (25 to 140) to 110.41 degrees (80 to 145). Most patients (97%) considered the outcome to be good or excellent. Our preliminary experience with this implant is encouraging and the results are superior to the earlier generation of resurfacings for the same length of follow-up.


Assuntos
Artroplastia de Quadril/métodos , Prótese de Quadril , Complicações Pós-Operatórias/etiologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Falha de Prótese , Reoperação , Infecção da Ferida Cirúrgica/etiologia , Resultado do Tratamento , Doenças Vasculares/etiologia
10.
J Bone Joint Surg Br ; 85(3): 351-3, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12729107

RESUMO

We have carried out a retrospective review of 11 Souter-Strathclyde primary total elbow arthroplasties in ten patients with osteoarthritis, over a period of nine years. The diagnosis was primary osteoarthritis in nine elbows and post-traumatic arthritis in two. The mean follow-up was 68 months (15 to 117). Although no patient was symptomatic, radiological review revealed evidence of loosening affecting three humeral and two ulnar components, one of which subsequently failed and was revised at 97 months. There were no dislocations, deep infections or mechanical failures. Complications included two superficial wound infections and two neurapraxias of the ulnar nerve which resolved. This study shows that the unlinked Souter-Strathclyde total elbow arthroplasty can be considered for patients with osteoarthritis and gives good symptomatic relief and improvement in function.


Assuntos
Artroplastia de Substituição/métodos , Articulação do Cotovelo/cirurgia , Prótese Articular , Osteoartrite/cirurgia , Idoso , Feminino , Seguimentos , Humanos , Imobilização , Masculino , Pessoa de Meia-Idade , Osteoartrite/fisiopatologia , Cuidados Pós-Operatórios/métodos , Falha de Prótese , Amplitude de Movimento Articular , Recidiva , Reoperação , Resultado do Tratamento
11.
Knee ; 10(1): 55-60, 2003 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-12649028

RESUMO

Component angles of 198 Kinemax total knee replacements were measured from standard short leg radiographs. An ideal tibio-femoral angle of between 4 and 10 degrees of valgus was achieved in 64.6% of patients. After an average follow-up of 6.5 years (range 4.5 to 9.5), there was no significant difference between knees in acceptable and suboptimal alignment in terms of pre- and post-operative knee and function scores and prevalence of radiolucent lines. Varus placement of the tibial component was significantly more common by trainee surgeons (P<0.001).


Assuntos
Artroplastia do Joelho/métodos , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/efeitos adversos , Mau Alinhamento Ósseo , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Osteoartrite do Joelho/diagnóstico por imagem , Período Pós-Operatório , Cuidados Pré-Operatórios , Probabilidade , Desenho de Prótese , Ajuste de Prótese , Radiografia , Sistema de Registros , Estudos Retrospectivos , Resultado do Tratamento
12.
Ann R Coll Surg Engl ; 84(5): 334-7, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12398127

RESUMO

Posterior shoulder dislocations are uncommon, with frequent delays in the diagnosis. Three missed posterior dislocations within our hospital caused us to review the standard radiographs taken and the knowledge of this condition. A total of 40 radiographers and 40 casualty officers were surveyed. Of the radiographers, 63% felt it unnecessary to perform two views, they complained that laterals were difficult to obtain because of patient distress. All the radiographers surveyed knew of alternative views, but would not perform them unless specifically requested. Casualty officers claimed always to request two views, but did not in 75% of cases. Only 20% were aware of alternative views, all would accept one view for exclusion of a dislocation and none were aware of the radiographic signs associated with a posterior dislocation. Increased education and a change of view would assist in decreasing the rate of missed diagnoses.


Assuntos
Luxação do Ombro/diagnóstico por imagem , Adulto , Idoso , Competência Clínica/normas , Serviço Hospitalar de Emergência , Inglaterra , Inquéritos Epidemiológicos , Hospitais Gerais , Humanos , Corpo Clínico Hospitalar , Pessoa de Meia-Idade , Prática Profissional , Estudos Prospectivos , Radiografia
13.
J Bone Joint Surg Br ; 83(3): 359-63, 2001 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-11341420

RESUMO

We reviewed the outcome of 422 primary cemented Kinemax total knee arthroplasties implanted into 369 patients over a period of five years, from January 1989. The operations were carried out at two NHS district general hospitals and one teaching hospital by 31 surgeons. During the period of review, 49 patients died and ten knees were lost to follow-up (68 knees). The mean Knee Society score improved from 28 before to 89 after surgery, and the mean function score increased from 23 to 79. The range of flexion improved from 92 degrees to 105 degrees. These improvements were maintained throughout the period of study. At the latest review radiolucent lines of 1 mm were seen around 15% of tibial components, 1.4% of patellar components and 9.5% of femoral components. In no case were these changes progressive. Using revision as the endpoint, cumulative survival was 99% after five years and 96.95% after nine years. All revisions were undertaken for deep infection or secondary trauma. Our study has shown that the Kinemax total knee replacement, when carried out with retention of the posterior cruciate ligament by surgeons of varying experience, produces very satisfactory results in the medium term.


Assuntos
Artroplastia do Joelho , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Amplitude de Movimento Articular , Reoperação , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...