1.
Australas Phys Eng Sci Med ; 39(4): 913-919, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27787758

RESUMO

This study evaluated the accuracy of image thresholding in the reconstruction of catheters in brachytherapy treatment planning systems. Six test cases including four planar catheter configurations, an interstitial prostate and an intracavitary treatment plan were made use of in this study. The four planar CT scanned catheter arrangements included; catheters placed approximately 1, 0.5 cm apart, catheters closely arranged in a plan (<0.5 cm apart) and a loop arrangement. The intracavitary plan consisted of catheters arranged inside a mould configuration. All reconstruction methods were based on tracking wire markers placed inside the plastic catheters. Each of these catheter arrangements was reconstructed using an existing window adjustment technique (manual reconstruction) in the treatment planning system followed by a CT-based automated thresholding technique available in the same planning system. A corresponding reconstructed catheter was created using a segmented catheter structure using image thresholding from another planning system within the same department. Co-ordinates from all the reconstructed catheters were compared against each other to assess the geometric shift between manual and threshold based reconstruction on each transaxial image using in-house software and the maximum variations were recorded for assessment. It was observed in general that automated thresholding technique could assist in catheter reconstruction for catheters which are greater than 0.5 cm apart. The segmented thresholding method reported smaller variations when compared to the manual reconstruction using window adjustment technique. Automated reconstruction saves time in the brachytherapy planning, however it was noted that it is not feasible for closely spaced catheters. Segmented catheter reconstruction although time consuming, did provide a better alternative in most cases.


Assuntos
Braquiterapia/métodos , Catéteres , Interpretação de Imagem Radiográfica Assistida por Computador , Humanos , Tomografia Computadorizada por Raios X
2.
Brachytherapy ; 14(2): 267-72, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25466360

RESUMO

PURPOSE: Patients with cervical and vaginal cancer sometimes have a less straightforward approach for choice of brachytherapy treatment owing to the tumor's location and clinical presentation. The staff at Royal Brisbane & Women's Hospital in Queensland, Australia, is trying to solve this problem by the use of an old technique in a new approach called vaginal molds. With a patient-specific vaginal mold, the appearance of the applicator and the dose distribution can be customized to provide an optimal treatment for each patient. METHODS AND MATERIALS: The technique used at the Royal Brisbane & Women's Hospital uses a flexible two-part putty, moulded to the shape of the vagina, in which standard catheters (flexible implant tubes) are incorporated, in a pattern designed to permit a dose distribution more conformal to the target volume. RESULTS: The presented technique is efficient and improves the accuracy of a homogeneous target cover and sparing of organs at risk for vaginal mold brachytherapy treatments at our institution. CONCLUSION: This technique offers a customizable option when traditional cylindrical- or dome-type applicators cannot be used, or provide inadequate dose coverage. Molds to match the patient anatomy can be created quickly, while allowing flexibility in positioning of catheters to achieve the desired dose distribution.


Assuntos
Braquiterapia/instrumentação , Neoplasias dos Genitais Femininos/radioterapia , Desenho de Equipamento , Feminino , Humanos , Doses de Radiação , Vagina