Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
1.
Eur J Cardiothorac Surg ; 59(5): 1059-1068, 2021 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-33517374

RESUMO

OBJECTIVES: Cardiac surgery training has become more challenging as patients and their diagnoses become more complex. Our goal was to develop a multicategorical assessment model for evaluating residents in cardiac surgery. This model is intended to ensure goal-directed progress in their training as well as to recognize and support their surgical talents. METHODS: We developed a new questionnaire in a multistage, 3-round process based on the Delphi method 'estimate-talk-estimate', using 55 competencies, including 38 general and 17 domain-specific competencies. Each competency is evaluated with 1 or more questions, to which 1 (not competent) to 6 (very competent) points can be chosen as an answer. RESULTS: The resulting model achieved 2 main goals: first, presenting a well-defined competency list for cardiac surgical training and second, providing an objective and realistic evaluation of trainees' abilities. Residents were assessed by all trainers to achieve a high level of objectivity. CONCLUSIONS: This evaluation model is highly objective, because residents are evaluated by multiple trainers. It allows individual support and enables better transparency in residency training. Talents and skills are evaluated, recognized and adopted as a base for individual feedback and personalized training programmes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cirurgia Geral , Internato e Residência , Competência Clínica , Educação de Pós-Graduação em Medicina , Cirurgia Geral/educação , Objetivos , Humanos
2.
Ann Thorac Surg ; 106(6): e297-e298, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-29723533

RESUMO

The Trifecta aortic valve has excellent hemodynamic performance as result of an expansive valve design with a bovine pericardial sheet externally mounted on a titanium stent. We report 2 cases of early Trifecta valve degeneration, both caused by partial rupture of one of the leaflet cusps 3 and 4 years post-implant. Post discharge, both patients had routinely performed echocardiography check-ups, without signs of valve failure. Transesophageal echocardiography performed during emergency hospital readmission due to severe dyspnea revealed transvalvular aortic regurgitation without signs of endocarditis. Urgent redo-surgery was successful in both cases, replacing the Trifecta prosthesis with a different bovine bioprosthesis.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Bioprótese , Próteses Valvulares Cardíacas , Desenho de Prótese , Falha de Prótese , Idoso , Bioprótese/efeitos adversos , Feminino , Humanos , Fatores de Tempo
3.
J Cardiothorac Vasc Anesth ; 28(5): 1257-63, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25281043

RESUMO

OBJECTIVES: The Glasgow Coma Scale (GCS) is used commonly for assessing patients' neurologic condition and outcome in intensive care units (ICUs); however, its reliability in cardiac surgical patients has been questioned. It has been claimed that active sedation is the cause of its unsuitability for these patients. This study aimed to compare the accuracy of GCS in cardiac surgical patients with and without active sedation to find out if the inapplicability of GCS in surgical patients is related to active sedation. DESIGN: This was an observational cohort study. SETTING: The study was conducted in a cardiac surgical intensive care unit between January 1, 2007 and December 31, 2009. PARTICIPANTS: All consecutive adult cardiac surgical patients were included in this study. INTERVENTIONS: All types of cardiac surgical procedures performed during the study period were included without any exceptions. The study population was divided into 2 groups: sedated and non-sedated. MEASUREMENTS AND MAIN RESULTS: GCS was calculated daily for the first 7 postoperative days. The authors developed a new 4-point neurologic descriptor (ND): (1) neurologically free, (2) ICU psychosis, (3) actively sedated, and (4) documented focal neurologic deficits. The accuracy of both scales (GCS and ND) at predicting ICU mortality was compared by replacing the GCS in the Sequential Organ Failure Assessment (SOFA) score with the new ND, producing a modified SOFA. GCS was not an accurate outcome predictor in non-sedated or sedated patients. The ND was superior to GCS. Correspondingly, the modified SOFA showed a significantly higher accuracy of ICU-mortality prediction than the original SOFA. CONCLUSIONS: Regardless of active sedation, GCS is not accurate at outcome prediction for cardiac surgical patients. The suggested ND is a simple and more accurate risk stratification variable in cardiac surgical ICUs.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/tendências , Escala de Coma de Glasgow/normas , Escala de Coma de Glasgow/tendências , Idoso , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Resultado do Tratamento
4.
Scand Cardiovasc J ; 48(2): 111-9, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-24645642

RESUMO

OBJECTIVES: Cardiac surgery patients are excluded from SAPS2 but included in SAPS3. Neither score is evaluated for this exclusive population; however, they are used daily. We hypothesized that SAPS3 may be superior to SAPS2 in outcome prediction in cardiac surgery patients. DESIGN: All consecutive patients undergoing cardiac surgery between January 2007 and December 2010 were included in our prospective study. Both models were tested with calibration and discrimination statistics. We compared the AUC of the ROC curves by DeLong's method and calculated OCC values. RESULTS: A total of 5207 patients with mean age of 67.2 ± 10.9 years were admitted to the ICU. The mean length of ICU stay was 4.6 ± 7.0 days and the ICU mortality was 5.9%. The two tested models had acceptable discriminatory power (AUC: SAPS2: 0.777-0.875; SAPS3: 0.757-893). SAPS3 had a low AUC and poor calibration on admission day. SAPS2 had poor calibration on Days 1-6 and 8. CONCLUSIONS: Despite including cardiac surgery patients, SAPS3 was not superior to SAPS2 in our analysis. In this large cohort of ICU cardiac surgery patients, performance of both SAPS models was generally poor. In this subset of patients, neither scoring system is recommended.


Assuntos
Unidades de Cuidados Coronarianos , Índice de Gravidade de Doença , Idoso , Procedimentos Cirúrgicos Cardíacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Risco Ajustado
5.
Thorac Cardiovasc Surg ; 61(8): 708-17, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24338631

RESUMO

BACKGROUND: Blood lactate is accepted as a mortality risk marker in intensive care units (ICUs), especially after cardiac surgery. Unfortunately, most of the commonly used ICU risk stratification scoring systems did not include blood lactate as a variable. We hypothesized that blood lactate alone can predict the risk of mortality after cardiac surgery with an accuracy that is comparable to those of other complex models. We therefore evaluated its accuracy at mortality prediction and compared it with that of other widely used complex scoring models statistically. METHODS: We prospectively collected data of all consecutive adult patients who underwent cardiac surgery between January 1, 2007, and December 31, 2009. By using χ2 statistics, a blood lactate-based scale (LacScale) with only four cutoff points was constructed in a developmental set of patients (January 1, 2007, and May 31, 2008). LacScale included five categories: 0 (≤ 1.7 mmol/L); 1 (1.8-5.9 mmol/L), 2 (6.0-9.3 mmol/L), 3 (9.4-13.3 mmol/L), and 4 (≥ 13.4 mmol/L). Its accuracy at predicting ICU mortality was evaluated in another independent subset of patients (validation set, June 1, 2008, and December 31, 2009) on both study-population level (calibration analysis, overall correct classification) and individual-patient-risk level (discrimination analysis, ROC statistics). The results were then compared with those obtained from other widely used postoperative models in cardiac surgical ICUs (Sequential Organ Failure Assessment [SOFA] score, Simplified Acute Physiology Score II [SAPS II], and Acute Physiology and Chronic Health Evaluation II [APACHE II] score). RESULTS: ICU mortality was 5.8% in 4,054 patients. LacScale had a reliable calibration in the validation set (2,087 patients). It was highly accurate in predicting ICU mortality with an area under the ROC curve (area under curve [AUC]; discrimination) of 0.88. This AUC was significantly larger than that of all the other models (SOFA 0.83, SAPS II: 0.79 and APACHE II: 0.76) according to DeLong's comparison. Integrating the LacScale in those scores further improved their accuracy by increasing their AUCs (0.88, 0.81, and 0.80, respectively). This improvement was also highly significant. CONCLUSION: Blood lactate accurately predicts mortality at both individual patient risk and patient cohort levels. Its precision is higher than that of other commonly used "complex" scoring models. The proposed LacScale is a simple and highly reliable model. It can be used (at bedside without electronic calculation) as such or integrated in other models to increase their accuracy.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Indicadores Básicos de Saúde , Ácido Láctico/sangue , APACHE , Idoso , Área Sob a Curva , Biomarcadores/sangue , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Distribuição de Qui-Quadrado , Análise Discriminante , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Razão de Chances , Escores de Disfunção Orgânica , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Regulação para Cima
6.
Eur J Cardiothorac Surg ; 44(6): 992-7; discussion 997-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23756348

RESUMO

OBJECTIVES: The purpose of this study was to develop a new scoring system for the prompt recognition of clinical deterioration and early treatment in postoperative cardiac surgical patients. METHODS: All consecutive adult patients undergoing cardiac surgery between 1st January 2007 and 31st December 2010 were included. The new score was calculated daily until intensive care unit (ICU) discharge. The score consists of 11 variables representing six different organ systems. Performance was assessed using receiver-operating characteristic (ROC) curves and calibration tests. RESULTS: A total of 5207 patients with a mean age of 67.2 ± 10.9 years were admitted to the ICU after cardiac surgery. The operations performed covered the whole spectrum of cardiac surgery. ICU mortality was 5.9%. The mean length of ICU stay was 4.6 ± 7.0 days. The new score had an excellent discrimination with areas under the ROC curves between 0.91 and 0.96. Calibration was also excellent reflected by observed/expected mortality ratios ranging between 1.0 and 1.26. CONCLUSIONS: The new score is a simple and reliable scoring system to assess organ dysfunction in cardiac intensive care patients. It is designed especially for personal digital assistants to simplify and accelerate the process of risk stratification in cardiac surgical ICUs.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Computadores de Mão , Medição de Risco/métodos , Índice de Gravidade de Doença , Idoso , Cuidados Críticos , Feminino , Mortalidade Hospitalar , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Resultado do Tratamento , Interface Usuário-Computador
7.
Thorac Cardiovasc Surg ; 61(7): 642-5, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23344759

RESUMO

There is no universally accepted single line treatment for residual space empyema. Recently, the vacuum-assisted instillation therapy was applied for wounds in different anatomical positions. However, it has not yet been applied as an intrathoracic management. Herein, we describe the first experience of intrathoracic vacuum-assisted instillation therapy for residual space empyema after extended thoracic surgery. It appears to be an attractive treatment option for patients with large contaminated pleural cavities in preparation for reconstructive surgery.


Assuntos
Empiema Pleural/terapia , Neoplasias Pulmonares/cirurgia , Tratamento de Ferimentos com Pressão Negativa , Pneumonectomia/efeitos adversos , Infecções por Pseudomonas/terapia , Pseudomonas aeruginosa/isolamento & purificação , Retalhos Cirúrgicos , Toracostomia , Idoso , Antibacterianos/administração & dosagem , Anti-Infecciosos Locais/administração & dosagem , Biguanidas/administração & dosagem , Empiema Pleural/diagnóstico , Empiema Pleural/microbiologia , Humanos , Neoplasias Pulmonares/patologia , Masculino , Infecções por Pseudomonas/diagnóstico , Infecções por Pseudomonas/microbiologia , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento
8.
J Cardiothorac Surg ; 6: 110, 2011 Sep 16.
Artigo em Inglês | MEDLINE | ID: mdl-21923900

RESUMO

BACKGROUND: The original Logistic Organ Dysfunction Sore (LODS) excluded cardiac surgery patients from its target population, and the suitability of this score in cardiac surgery patients has never been tested. We evaluated the accuracy of the LODS and the usefulness of its daily measurement in cardiac surgery patients. The LODS is not a true logistic scoring system, since it does not use ß-coefficients. METHODS: This prospective study included all consecutive adult patients who were admitted to the intensive care unit (ICU) after cardiac surgery between January 2007 and December 2008. The LODS was calculated daily from the first until the seventh postoperative day. Performance was assessed with Hosmer-Lemeshow (HL) goodness-of-fit test (calibration) and receiver operating characteristic (ROC) curves (discrimination) from ICU admission day until day 7. The outcome measure was ICU mortality. RESULTS: A total of 2801 patients (29.6% female) with a mean age of 66.4 ± 10.7 years were included. The ICU mortality rate was 5.2% (n = 147). The mean stay on the ICU was 4.3 ± 6.8 days. Calibration of the LODS was good with no significant difference between expected and observed mortality rates on any day (p ≥ 0.05). The initial LODS had an area under the ROC curve (AUC) of 0.81. The AUC was best on ICU day 3 with a value of 0.93, and declined to 0.85 on ICU day 7. CONCLUSIONS: Although the LODS has not previously been validated for cardiac surgery patients it showed reasonable accuracy in prediction of ICU mortality in patients after cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência de Múltiplos Órgãos/mortalidade , Gestão de Riscos/métodos , Idoso , Área Sob a Curva , Feminino , Mortalidade Hospitalar , Humanos , Unidades de Terapia Intensiva , Masculino , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Índice de Gravidade de Doença
10.
Eur J Cardiothorac Surg ; 38(1): 104-9, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20219387

RESUMO

OBJECTIVES: The purpose of this study was to develop a specific postoperative score in intensive care unit (ICU) cardiac surgical patients for the assessment of organ dysfunction and survival. To prove the reliability of the new scoring system, we compared its performance to existing ICU scores. METHODS: This prospective study consisted of all consecutive adult patients admitted after cardiac surgery to our ICU over a period of 5.5 years. Variables were evaluated using the patients of the first year who stayed in ICU for at least 24h. The reproducibility was then tested in two validation sets using all patients. Performance was assessed with the Hosmer-Lemeshow (HL) goodness-of-fit test and receiver operating characteristic (ROC) curves and compared with the Acute Physiology and Chronic Health Evaluation (APACHE II) and Multiple Organ Dysfunction Score (MODS). The outcome measure was defined as 30-day mortality. RESULTS: A total of 6007 patients were admitted to the ICU after cardiac surgery. Mean HL values for the new score were 5.8 (APACHE II, 11.3; MODS, 9.7) for the construction set, 7.2 (APACHE II, 8.0; MODS, 4.5) for the validation set I and 4.9 for the validation set II. The mean area under the ROC curve was 0.91 (APACHE II, 0.86; MODS, 0.84) for the new score in the construction set, 0.88 (APACHE II, 0.84; MODS, 0.84) in the validation set I and 0.92 in the validation set II. CONCLUSIONS: Most of general ICU scoring systems use extensive data collection and focus on the first day of ICU stay. Despite this fact, general scores do not perform well in the prediction of outcome in cardiac surgical patients. Our new 10-variable risk index performs very well, with calibration and discrimination very high, better than general severity systems, and it is an appropriate tool for daily risk stratification in ICU cardiac surgery patients. Thus, it may serve as an expert system for diagnosing organ failure and predicting mortality in ICU cardiac surgical patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/mortalidade , Unidades de Terapia Intensiva/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Métodos Epidemiológicos , Feminino , Alemanha/epidemiologia , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Cuidados Pós-Operatórios/métodos , Período Pós-Operatório , Prognóstico , Adulto Jovem
11.
Pacing Clin Electrophysiol ; 33(7): 860-4, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20180913

RESUMO

AIMS: Third-generation mobile phones, UMTS (Universal Mobile Telecommunication System), were recently introduced in Europe. The safety of these devices with regard to their interference with implanted pacemakers is as yet unknown and is the point of interest in this study. METHODS AND RESULTS: The study comprised 100 patients with permanent pacemaker implantation between November 2004 and June 2005. Two UMTS cellular phones (T-Mobile, Vodafone) were tested in the standby, dialing, and operating mode with 23 single-chamber and 77 dual-chamber pacemakers. Continuous surface electrocardiograms (ECGs), intracardiac electrograms, and marker channels were recorded when calls were made by a stationary phone to cellular phone. All pacemakers were tested under a "worst-case scenario," which includes a programming of the pacemaker to unipolar sensing and pacing modes and inducing of a maximum sensitivity setting during continuous pacing of the patient. Patients had pacemaker implantation between June 1990 and April 2005. The mean age was 68.4 +/- 15.1 years. Regardless of atrial and ventricular sensitivity settings, both UMTS mobile phones (Nokia 6650 and Motorola A835) did not show any interference with all tested pacemakers. In addition, both cellular phones did not interfere with the marker channels and the intracardiac ECGs of the pacemakers. CONCLUSION: Third-generation mobile phones are safe for patients with permanent pacemakers. This is due to the high-frequency band for this system (1,800-2,200 MHz) and the low power output between 0.01 W and 0.25 W.


Assuntos
Artefatos , Telefone Celular/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos , Marca-Passo Artificial/estatística & dados numéricos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Interact Cardiovasc Thorac Surg ; 10(5): 766-9, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20154069

RESUMO

OBJECTIVES: Gaseous embolism is a possible complication during off-pump coronary surgery with the use of a blower and can cause ischemic injuries. We describe two different possible mechanisms of carbon-dioxide embolization. METHODS: Out of 2196 coronary bypass surgeries, between 1 January 2007 and 31 December 2009, there were 977 off-pump operations. Two off-pump cases (0.2%) had gaseous (carbon-dioxide) emboli that migrated against blood stream proximally through T-anastomoses and then into the native coronary vessels. These emboli caused a temporary haemodynamic deterioration in other territories. Two types of T-anastomoses were included [saphenous vein on left internal thoracic artery (LITA) or right internal thoracic artery (RITA) on LITA]. RESULTS: Simple procedures and measurements were necessary but enough to regain haemodynamic stability. There was no effect on the postoperative outcome. CONCLUSION: We have concluded that carbon-dioxide emboli can also cause massive but temporary haemodynamic deterioration during off-pump surgery despite higher solubility in blood. The blower should be used only when a bull-dog clamp is applied on the graft. Also, proper de-airing and flushing of grafts is very important and avoids consequences of the trapped small emboli.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Doença das Coronárias/cirurgia , Embolia Aérea/diagnóstico por imagem , Complicações Intraoperatórias/diagnóstico , Idoso , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Dióxido de Carbono/efeitos adversos , Dióxido de Carbono/farmacologia , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/métodos , Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Doença das Coronárias/diagnóstico por imagem , Embolia Aérea/cirurgia , Feminino , Seguimentos , Rejeição de Enxerto , Sobrevivência de Enxerto , Hemodinâmica/fisiologia , Humanos , Insuflação/efeitos adversos , Complicações Intraoperatórias/cirurgia , Masculino , Pessoa de Meia-Idade , Radiografia , Medição de Risco , Taxa de Sobrevida , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...