Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Neuropsychology ; 15(4): 535-43, 2001 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-11761043

RESUMO

This cross-sectional study examined modal attention asymmetries in patients with schizophrenia (n = 47) and bipolar disorder (n = 42), as contrasted to a matched-sample comparison group of normal participants (n = 89). A test of continuous auditory and visual attention was the primary measure. The data were analyzed from 2 experimental conditions: simple modal responses (auditory and visual) and modal switching responses (ipsimodal and cross-modal switching). In the simple modal condition, patients with schizophrenia demonstrated a visual over auditory asymmetry; patients with bipolar disorder showed no differences. In modal switching conditions, however, patients with bipolar disorder displayed a significant auditory over visual asymmetry. No main effect was detected between medications and attention functioning. Results are discussed in light of differentiating these 2 populations on the basis of modal specificity of attention functioning.


Assuntos
Atenção , Transtorno Bipolar/psicologia , Dominância Cerebral , Reconhecimento Visual de Modelos , Esquizofrenia/diagnóstico , Psicologia do Esquizofrênico , Percepção da Fala , Adulto , Idoso , Transtorno Bipolar/diagnóstico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Psicometria , Tempo de Reação , Valores de Referência
2.
J Int Neuropsychol Soc ; 5(6): 534-9, 1999 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-10561934

RESUMO

The relationship between neurocognitive impairment and employment in a cohort of 130 predominantly symptomatic individuals with HIV-1 infection was examined. Participants were classified as employed (full or part-time for pay) or unemployed (N = 64) and administered a neuropsychological test battery. When covarying for CD4 count, age, and physical limitations, the results revealed that unemployed men performed below that of employed participants on tasks of memory, set shifting-cognitive flexibility, and psychomotor speed. The results are discussed within the context of similar findings in other illnesses.


Assuntos
Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/etiologia , Emprego , Soropositividade para HIV/complicações , Testes Neuropsicológicos , Adulto , Transtornos Cognitivos/psicologia , Humanos , Masculino , Índice de Gravidade de Doença
3.
Acta Anaesthesiol Scand ; 43(4): 458-63, 1999 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10225081

RESUMO

BACKGROUND: The absorption of irrigation fluid during transurethral resection of the prostate (TURP) is determined primarily by hydrostatic pressure in the bladder and prostatic venous pressure. In comparison to spontaneously breathing patients, patients undergoing mechanical ventilation with positive pressure have a raised central venous pressure and a reduced venous return, both of which can influence intravascular absorption. The purpose of the prospective study was to compare the effects of general (GA) and spinal anaesthetic (SA) techniques on the perioperative absorption of irrigating fluid in patients undergoing TURP. METHODS: Forty patients undergoing TURP were randomised and assigned either to group GA or SA. Irrigating fluid absorption was traced by adding 1.5% (w/v) ethanol to the irrigating fluid. Perioperative blood ethanol concentration (BEC), haemoglobin concentration, haematocrit, serum sodium concentration and central venous pressure (CVP) were measured at 10-min intervals during TURP and at 30-min intervals while patients were recovering. Absorption routes were indexed by the BEC and changes in serum sodium concentrations. Where the BEC was greater than 0.05 mg.mL-1, absorption of irrigating fluid was assumed. For assessing the volume of irrigating fluid absorbed, the maximum BEC, the absorption rate, the area under the BEC curve (AUC), and the volumes calculated according to the Hahn nomogram (Volin) for each patient were taken into consideration. RESULTS: There were 15 cases of irrigating fluid absorption in patients receiving GA (75%), and 11 in those receiving SA (55%). CVP was significantly lower in spontaneously breathing patients with SA as compared to those with GA (P < 0.05). In patients with irrigating fluid absorption the maximum BEC (P < 0.02), as well as the rate of irrigant fluid absorption (P < 0.01), were significantly higher amongst patients receiving SA. In this group, the calculated area under the curve and the absorbed fluid volumes determined with the nomogram were significantly increased (P < 0.05). CONCLUSION: The absorption of irrigation fluid during the TURP is significantly more marked amongst spontaneously breathing patients with regional anaesthesia in comparison to patients undergoing general anaesthesia with positive pressure ventilation. The markedly lower central venous pressure before the start of irrigation should be considered as a possible cause of this effect.


Assuntos
Anestesia Geral , Raquianestesia , Prostatectomia , Sorbitol/farmacocinética , Absorção , Idoso , Área Sob a Curva , Pressão Venosa Central/fisiologia , Etanol/sangue , Seguimentos , Hematócrito , Hemoglobinas/análise , Humanos , Pressão Hidrostática , Indicadores e Reagentes , Masculino , Respiração com Pressão Positiva , Estudos Prospectivos , Próstata/irrigação sanguínea , Respiração , Sódio/sangue , Irrigação Terapêutica , Bexiga Urinária/metabolismo , Pressão Venosa/fisiologia
4.
Biomed Tech (Berl) ; 41(3): 54-9, 1996 Mar.
Artigo em Alemão | MEDLINE | ID: mdl-8652785

RESUMO

Absorption of irrigating fluid by blood vessels during endoscopic urological surgery may result in cardiac insufficiency, impairment of electrolyte metabolism and neurological disorders. For detection and quantification of the volume absorbed, ethanol is added to the irrigating fluid. The resulting blood alcohol concentration can be obtained by measuring the alcohol concentration in the expired air. For artificially ventilated patients receiving a general anesthetic, electrochemical sensors that remain uneffected by volatile anaesthetics are used. In the present study, the measuring accuracy of three different alcohol analyzers using electrochemical sensors was tested against an infrared reference sensor during simulated ventilation in a lung model, and the optimal trigger time point for sampling determined. All three devices tested show the same degree of accuracy as the reference. For manual endexpiratory triggering devices with short sampling times are best suitable. Portable devices powered by rechargeable batteries and usable with both spontaneously breathing and ventilated patients are recommended for clinical application.


Assuntos
Testes Respiratórios/instrumentação , Etanol/farmacocinética , Modelos Anatômicos , Respiração Artificial , Água Corporal/metabolismo , Eletroquímica/instrumentação , Desenho de Equipamento , Humanos , Pulmão/metabolismo , Taxa de Depuração Metabólica/fisiologia , Volume de Ventilação Pulmonar/fisiologia
5.
Anaesthesist ; 45(2): 154-62, 1996 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-8720888

RESUMO

UNLABELLED: Absorption of irrigating fluid in transurethral prostatic resection (TURP) and percutaneous nephrolitholapaxy (PNL) into veins or delayed absorption due to fluid extravasation may result in a TURP syndrome. The measurement of end-tidal breath alcohol concentration (et AC) as a monitor of absorption of irrigating fluid labelled with 2% ethanol is limited by the disturbance of infrared sensors by volatile anaesthetics and nitrous oxide (N2O) (Fig. 2). An electrochemical sensor is acceptable for this method. The aim of the present study was the evaluation of breath alcohol measurements using an electrochemical sensor device (Alcomed 3010, Envitec). The stability of the sensor in the presence of volatile anaesthetics was examined using a lung model. In a clinical investigation, the device was then applied to spontaneously breathing or mechanically ventilated patients inhaling volatile anaesthetics during endoscopic urological surgery. METHOD: A two-chamber lung model filled with water for performing noninvasive measurements at the mouth of a patient has already been introduced by Brunner et al. (Fig. 1). With the addition of different amounts of ethanol to the temperature-controlled water, a constant ethanol concentration is achievable in the air above the water that is dependent on adjustments of the ventilator. Increasing concentrations of volatile anaesthetics (isoflurane, enflurane, halothane, and sevoflurane) were added to the fresh gas flow (2 l O2/3 l N2O) and etACs were measured using the manually triggered self-absorbent electrochemical sensor. First, regression equations were established between breath alcohol concentrations and increased volatile anaesthetic concentrations. Regression equations were then established between end-tidal anaesthetic gas concentrations and vaporizer adjustments in order to rule out an influence of ethanol on the anaesthetic gas monitor Ultima V (Datex). In the clinical investigation, 53 intubated and ventilated patients (33 undergoing PNL, 20 undergoing TURP) and 48 patients breathing spontaneously (32 with inhalation anaesthesia, 16 with spinal anaesthesia) were investigated. The etAC was measured with the Alcomed 3010 and compared with gas-chromatographically registered blood alcohol concentrations (BAC). The study had previously been approved by the Ethical Committee of the Medical University of Luebeck. Patients with liver disease and a history of toxic abuse were excluded. Only one value per patient (maximum BAC) was included in the statistics in order to avoid a cluster effect. RESULTS: The lung model experiments demonstrated that the measurement of etAC with an electrochemical sensor is free of interference by volatile anaesthetics (Table 1). The slope of the regression between the measured alcohol concentration and increased concentrations of anaesthetics did not differ significantly from baseline values. The measurement of end-tidal anaesthetic concentrations was not significantly different from vaporizer adjustments in the presence of increased alcohol concentrations (Table 2). During the clinical investigation, a regression between etAC and BAC was determined for both groups. For the group of patients breathing spontaneously, the correlation coefficient was 0.961 and the regression equation revealed etAC = 0.5677*BAC-0.1303 (Fig. 5). However, in the group of ventilated patients a biphasic course was shown that was dependent on BAC (Fig. 6). At BAC < 0.4%, a similar correlation (r = 0.856) to the spontaneously breathing group could be seen (regression equation: etAC = 0.617*BAC-0.020). Above 0.4% BAC there was no acceptable correlation (r = 0.444, regression equation: etAC = 0.202*BAC+0.104). CONCLUSIONS: The tested electrochemical sensor does not interfere with volatile anaesthetics and N2O as demonstrated by a lung model. There is a good correlation between etAC and BAC measurements in patients breathing spontaneously with special regard to the slope of the regression (s = 0.57).


Assuntos
Anestésicos/análise , Testes Respiratórios/instrumentação , Etanol/análise , Monitorização Intraoperatória/instrumentação , Interações Medicamentosas , Eletroquímica , Estudos de Avaliação como Assunto , Humanos , Litotripsia , Masculino , Modelos Biológicos , Próstata/cirurgia , Irrigação Terapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...