Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bone ; 120: 25-37, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30240961

RESUMO

Clinical retrospective studies have only reported limited improvements in hip fracture classification accuracy using finite element (FE) models compared to conventional areal bone mineral density (aBMD) measurements. A possible explanation is that state-of-the-art quasi-static models do not estimate patient-specific loads. A novel FE modeling technique was developed to improve the biofidelity of simulated impact loading from sideways falling. This included surrogate models of the pelvis, lower extremities, and soft tissue that were morphed based on subject anthropometrics. Hip fracture prediction models based on aBMD and FE measurements were compared in a retrospective study of 254 elderly female subjects from the AGES-Reykjavik study. Subject fragility ratio (FR) was defined as the ratio between the ultimate forces of paired biofidelic models, one with linear elastic and the other with non-linear stress-strain relationships in the proximal femur. The expected end-point value (EEV) was defined as the FR weighted by the probability of one sideways fall over five years, based on self-reported fall frequency at baseline. The change in maximum volumetric strain (ΔMVS) on the surface of the femoral neck was calculated between time of ultimate femur force and 90% post-ultimate force in order to assess the extent of tensile tissue damage present in non-linear models. After age-adjusted logistic regression, the area under the receiver-operator curve (AUC) was highest for ΔMVS (0.72), followed by FR (0.71), aBMD (0.70), and EEV (0.67), however the differences between FEA and aBMD based prediction models were not deemed statistically significant. When subjects with no history of falling were excluded from the analysis, thus artificially assuming that falls were known a priori with no uncertainty, a statistically significant difference in AUC was detected between ΔMVS (0.85), and aBMD (0.74). Multivariable linear regression suggested that the variance in maximum elastic femur force was best explained by femoral head radius, pelvis width, and soft tissue thickness (R2 = 0.79; RMSE = 0.46 kN; p < 0.005). Weighting the hip fracture prediction models based on self-reported fall frequency did not improve the models' sensitivity, however excluding non-fallers lead to significant differences between aBMD and FE based models. These findings suggest that an accurate assessment of fall probability is necessary for accurately identifying individuals predisposed to hip fracture.


Assuntos
Análise de Elementos Finitos , Fraturas do Quadril/classificação , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Estudos de Coortes , Feminino , Fêmur/patologia , Humanos , Islândia , Masculino , Probabilidade , Curva ROC , Estudos Retrospectivos
2.
J Mech Behav Biomed Mater ; 78: 196-205, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29172124

RESUMO

Sideways falls are largely responsible for the highly prevalent osteoporotic hip fractures in today's society. These injuries are dynamic events, therefore dynamic FE models validated with dynamic ex vivo experiments provide a more realistic simulation than simple quasi-static analysis. Drop tower experiments using cadaveric specimens were used to identify the material mapping strategy that provided the most realistic mechanical response under impact loading. The present study tested the addition of compression-tension asymmetry, tensile bone damage, and cortical-specific strain rate dependency to the material mapping strategy of fifteen dynamic FE models of the proximal femur, and found improved correlations and reduced error for whole bone stiffness (R2 = 0.54, RSME = 0.87kN/mm) and absolute maximum force (R2 = 0.56, RSME =0.57kN), and a high correlation in impulse response (R2 = 0.82, RSME =12.38kg/s). Simulations using fully bonded nodes between the rigid bottom plate and PMMA cap supporting the femoral head had higher correlations and less error than simulations using a frictionless sliding at this contact surface. Strain rates over 100/s were observed in certain elements in the femoral neck and trochanter, indicating that additional research is required to better quantify the strain rate dependencies of both trabecular and cortical bone at these strain rates. These results represent the current benchmark in dynamic FE modeling of the proximal femur in sideways falls. Future work should also investigate improvements in experimental validation techniques by developing better displacement measurements and by enhancing the biofidelity of the impact loading wherever possible.


Assuntos
Acidentes por Quedas , Fêmur , Teste de Materiais , Fenômenos Mecânicos , Idoso , Fenômenos Biomecânicos , Feminino , Análise de Elementos Finitos , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...