Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Arq. odontol ; 59: 106-113, 2023. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-1518971

RESUMO

Aim: The purpose of this study was to evaluate the efficacy to determine the root canal length, in vitro,of both the electronic apex locator (M2) and the autostop (AS - M3) functions of the Endus Duo Gnatus endodontic motor (Gnatus, São Paulo, SP, Brazil). Methods: Thirty extracted human single-rooted premolars had their root canal lengths (TLs) up to the apical foramen determined using the Endus Duo Gnatus in two ways: (1) In the stainless steel (SS) control group, the measurement was obtained using a stainless steel hand instrument with the electronic locator mode (M2 function) connected to a stainless-steel hand instrument (K-file #15). In the NiTi rotary instrument (NiTi RI) intervention group, the measurement was obtained during the instrumentation (M3 function) of the root canals with a nickel-titanium rotary instrument (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, USA), size 25/.06. The NiTi manually used instrument (NiTi MUI) Intervention group performed the measurement in locator mode using a Hyflex instrument, placed to true length manually. Statistical analysis was performed using ANOVA followed by the Tukey post-hoc test with a significance level of p < 0.05. Results: The true mean length and standard deviation (SD) of the standardized root canals were 18.40 ± 2.14mm, while the mean lengths and standard deviations (SD) were 18.29 ± 1.89mm, 18.22 ± 1.85mm, and 17.24 ± 2.09mm for the SS, NiTi RI, and NiTi MUI groups, respectively. However, data from the NiTi MUI Intervention group indicated shorter root canal lengths when compared to the SS control group and the NiTi RI Intervention group values, and were significantly shorter than the true canal length (p < 0.001). Conclusions:The use of the motor in NiTi RI Intervention group showed acceptable results. However, the NiTi MUI Intervention group resulted in unacceptable short measurements.


Objetivo: O objetivo deste estudo foi avaliar a eficácia na determinação do comprimento do canal radicular, in vitro, das funções localizador eletrônico foraminal (M2) e auto-parada durante a instrumentação (M3) do motor endodôntico Endus Duo Gnatus ( Gnatus, São Paulo, SP, Brasil). Métodos: Trinta pré-molares humanos uniradiculares extraídos tiveram seus comprimentos de canais radiculares (CRTs) até o forame apical determinados usando o Endus Duo Gnatus de duas maneiras: (1) No grupo controle de aço inoxidável (SS), a medida foi obtida usando um instrumento manual de aço inoxidável com modo de localização eletrônica foraminal (função M2) conectado a um instrumento manual de aço inoxidável (lima tipo K #15). No grupo intervenção instrumento rotatório NiTi (NiTi RI), a medida foi obtida durante a instrumentação (função M3) dos canais radiculares com instrumento rotatório de níquel-titânio (Hyflex CM: Coltene Whaledent, Cuyahoga Falls, OH, EUA), tamanho 25/.06. O grupo de intervenção NiTi instrumento usado manualmente (NiTi MUI) realizou a medição no modo localizador foraminal usando um instrumento Hyflex, colocado manualmente no comprimento real do dente. A análise estatística foi realizada por meio de ANOVA seguida do teste post-hoc de Tukey com nível de significância de p < 0,05. Resultados: Os comprimentos reais médios dos dentes e desvios-padrão (DP) dos canais radiculares padronizados foram 18,40 ± 2,14 mm, enquanto os comprimentos médios e desvios- padrão (DP) foram 18,29 ± 1,89 mm, 18,22 ± 1,85 mm e 17,24 ± 2,09 mm para os grupos SS, NiTi RI e NiTi MUI, respectivamente. No entanto, os dados do grupo de intervenção NiTi MUI indicaram comprimentos de canais radiculares mais curtos quando comparados aos valores do grupo controle SS e do grupo de intervenção NiTi RI, e foram significativamente mais curtos que o comprimento real do canal (p < 0,001). Conclusões: A utilização do motor no grupo Intervenção NiTi RI apresentou resultados aceitáveis. No entanto, o grupo de intervenção NiTi MUI resultou em medições curtas inaceitáveis.


Assuntos
Pesos e Medidas , Equipamentos Odontológicos , Cavidade Pulpar , Endodontia
2.
Aust Endod J ; 46(1): 52-59, 2020 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-31087492

RESUMO

This study assessed the cutting properties of two Nickel Titanium file systems with different designs and manufacturing materials. ProTaper Next X1 and X2 (PTN; Dentsply Sirona) and ProTaper Universal S2 and F1 (PTU; Dentsply Sirona) instruments were employed. The cutting parameters, that is torque and apical forces, were determined using a specially designed bench-testing machine. Dimensional and geometric parameters were considered to evaluate the results. The average maximum torque values showed statistically significant differences (P < 0.05) among all instruments. Apical force for PTN X2 and PTU F1 instruments initially decreased and then experienced a rapid increase in the last 2 mm of the canal. For PTN X1 and PTU S2, apical force increased during the entire test. When compared to PTU files, PTN required higher torque and apical forces during the shaping procedure. The results lead us to conclude that PTN instruments demonstrated a lower cutting efficiency than PTU.


Assuntos
Ligas Dentárias , Preparo de Canal Radicular , Desenho de Equipamento , Teste de Materiais , Titânio , Torque
3.
Arq. odontol ; 54: 1-8, jan.-dez. 2018. ilus, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-996747

RESUMO

Aim:This study tested a setup for in vitro experimental analysis of axial forces and torque during the preparation of artificial canals using nickel-titanium reciprocating endodontic files.Methods: The cutting efficiency of Reciproc (RC) and WaveOne (WO) reciprocating size 25/.08 instruments (n = 10) was evaluated, taking into account their dimensional and geometrical features. Measurements of the diameter at each millimeter from the tip, pitch length, helical angle, and cross-sectional design and area were assessed. Cutting efficiency tests were carried out on a specific bench device by measuring the torque and axial force required during artificial canal shaping. Statistical analysis was performed using one-way ANOVA (α = 0.05). Results:The WO samples showed larger A3 mean values than did the RC instruments (p < 0.0001), despite having equal diameters at 3mm from the tip (D3) (p = 0.521). The mean values of pitch length were higher for RC than for WO instruments (p< 0.0001), with consequently smaller helical angles (p < 0.0001). For the cutting efficiency tests, the required torque was lower for the RC group when compared to the WO group, but it was significant only in the first stage of insertion in the artificial canals (p = 0.008). Regarding the apical force, the RC instruments reached higher values when compared to the WO instruments (p = 0.04) in the second stage of cutting action. Conclusion: Reciproc instruments demonstrated statistically higher cutting efficiency when compared to WaveOne instruments.


Objetivo: Este estudo testa uma configuração para análise experimental in vitro de forças axiais e torque durante o preparo de canais artificiais usando instrumentos endodônticos reciprocantes de níquel-titânio. Métodos: Foi avaliada a eficiência de corte dos instrumentos reciprocantes tamanho 25 / 0,08 (n = 10) Reciproc (RC) e WaveOne (WO), levando em consideração suas características dimensionais e geométricas. Medidas do diâmetro a cada milímetro a partir da ponta, comprimento de pitch, ângulo helicoidal e desenho da área transversal e área foram avaliados. Testes de eficiência de corte foram realizados em um dispositivo de bancada específico, medindo-se o torque e a força axial exigidos durante a modelagem de canais artificiais. A análise estatística foi feita com ANOVA one-way (α = 0,05). Resultados: As amostras de WO mostraram valores médios A3 maiores do que os instrumentos RC (p <0,0001), apesar de terem diâmetros iguais a 3 mm da ponta (D3) (p = 0,521). Os valores médios do comprimento do pitch foram maiores para o RC do que para os instrumentos do WO (p < 0,0001), com consequentemente menores ângulos helicoidais (p < 0,0001). Para os testes de eficiência de corte, o torque necessário foi menor para o grupo RC em comparação com o grupo WO, mas significativo apenas no primeiro estágio de inserção nos canais artificiais (p = 0,008). Em relação à força apical, os instrumentos RC alcançaram valores maiores em relação aos instrumentos WO (p = 0,04) no segundo estágio de corte. Conclusão: Os instrumentos Reciproc demonstraram uma eficiência de corte estatisticamente superior em comparação com os instrumentos WaveOne.


Assuntos
Teste de Materiais , Torque , Instrumentos Odontológicos , Cavidade Pulpar , Endodontia
4.
J Endod ; 43(4): 613-618, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28190587

RESUMO

INTRODUCTION: The aim of this study was to evaluate the influence of cyclic deformation on the torsional resistance of controlled memory (CM) nickel-titanium files in comparison with superelastic (SE) instruments with similar geometric and dimensional characteristics. METHODS: New 30/.06 HyFlex (HF; Coltene/Whaledent, Inc, Cuyahoga Falls, OH), Typhoon (Clinician's Choice Dental Products, New Milford, CT), RaCe (FKG, La-Chaux De Fonds, Switzerland), and ProTaper Universal F2 instruments (F2; Dentsply Maillefer, Ballaigues, Switzerland) were assessed. The diameter and pitch length were measured along the active part of the instruments. The number of cycles to failure (Nf) in flexural fatigue and the torsional resistance were evaluated for new files (n = 10). Ten new instruments of each type were fatigued to 3/4 of their fatigue life and then submitted to torsion until rupture. Data were analyzed using 1-way analysis of variance (α = .05). RESULTS: New CM files had a significantly higher Nf when compared with SE instruments; HF exhibited the highest value (P = .001). The mean torque value for F2 was the highest (P = .001). CM files precycled to 3/4 Nf had a significantly lower torque than the new files (HF: P = .003, Typhoon: P = .001), whereas the SE instruments displayed no significant differences (F2: P = .059, RaCe: P = .079). CONCLUSIONS: Cyclic flexural loading significantly reduced the torsional resistance of CM instruments.


Assuntos
Endodontia/instrumentação , Falha de Equipamento , Níquel , Titânio , Ligas , Análise de Falha de Equipamento , Humanos , Torção Mecânica
5.
J Appl Oral Sci ; 24(4): 310-6, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27556200

RESUMO

OBJECTIVE: The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. MATERIAL AND METHODS: Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. RESULTS: WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. CONCLUSION: After clinical use, no statistically significant reduction in the torsional resistance was observed.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Torção Mecânica , Desenho de Equipamento , Falha de Equipamento , Teste de Materiais , Microscopia Eletrônica de Varredura , Níquel , Valores de Referência , Rotação , Estresse Mecânico , Propriedades de Superfície , Titânio , Torque
6.
J. appl. oral sci ; J. appl. oral sci;24(4): 310-316, July-Aug. 2016. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-792591

RESUMO

ABSTRACT Torsional overload is a fracture representative parameter for instruments in single-file techniques. Objective The aim of this study was to assess the influence of clinical use, in vivo, on the torsional behavior of Reciproc and WaveOne instruments considering the possibility that they degraded with use. Material and Methods Diameter at each millimeter, pitch length, and area at 3 mm from the tip were determined for both types of instruments. Twenty-four instruments, size 25, 0.08 taper, of each system were divided into two groups (n=12 each): Control Group (CG), in which new Reciproc (RC) and WaveOne Primary (WO) instruments were tested in torsion until rupture based on ISO 3630-1; and Experimental Group (EG), in which each new instrument was clinically used to clean and shape the root canals of one molar. After clinical use, the instruments were analyzed using optical and scanning electron microscopy and subsequently tested in torsion until fracture. Data were analyzed using one-way analysis of variance at a=.05. Results WO instruments showed significantly higher mean values of cross-sectional area A3 (P=0.000) and smaller pitch lengths than RC instruments with no statistically significant differences in the diameter at D3 (P=0.521). No significant differences in torsional resistance between the RC and WO new instruments (P=0.134) were found. The clinical use resulted in a tendency of reduction in the maximum torque of the analyzed instruments but no statistically significant difference was observed between them (P=0.327). During the preparation of the root canals, two fractured RC instruments and longitudinal and transversal cracks in RC and WO instruments were observed through SEM analysis. Conclusion After clinical use, no statistically significant reduction in the torsional resistance was observed.


Assuntos
Preparo de Canal Radicular/instrumentação , Instrumentos Odontológicos , Torção Mecânica , Valores de Referência , Rotação , Estresse Mecânico , Propriedades de Superfície , Titânio , Teste de Materiais , Microscopia Eletrônica de Varredura , Torque , Desenho de Equipamento , Falha de Equipamento , Níquel
7.
ScientificWorldJournal ; 2016: 7617493, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27314059

RESUMO

The effects of the presence of the R-phase in a near-equiatomic NiTi alloy on the mechanical responses of an endodontic instrument were studied by using finite element analysis. The input data for the constitutive model in the simulation were obtained by tensile testing of three NiTi wires: superelastic austenite NiTi, austenite + R-phase NiTi, and fully R-phased NiTi. The wires were also characterized by X-ray diffraction and differential scanning calorimetry. A commercially available endodontic instrument was scanned using microcomputed tomography, and the resulting images were used to build the geometrical model. The numerical analyses were performed in ABAQUS using load and boundary conditions based on the ISO 3630-1 specification for the bending and torsion of endodontic instruments. The modeled instrument containing only R-phase demanded the lowest moment to be bent, followed by the one with mixed austenite + R-phase. The superelastic instrument, containing essentially austenite, required the highest bending moment. During bending, the fully R-phased instrument reached the lowest stress values; however, it also experienced the highest angular deflection when subjected to torsion. In summary, this simulation showed that NiTi endodontic instruments containing only R-phase in their microstructure would show higher flexibility without compromising their performance under torsion.

8.
J Endod ; 41(9): 1540-4, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26211564

RESUMO

INTRODUCTION: The aim of this study was to evaluate the cutting characteristics of 3 nickel-titanium instruments with different cross-sectional designs using a recently developed methodology. METHODS: Insertion tests at a constant rate of 5.4 mm/min were performed on a bench test device by measuring the torque and apical force required for penetrating prefabricated acrylic blocks containing an artificial canal preflared with #10 and #15 K-files. Size 20/.06 Mtwo (VDW, Munich, Germany) and RaCe (FKG, La-Chaux De Fonds, Switzerland) instruments, together with ProTaper Universal (PTU) F1 instruments (Dentsply Maillefer, Ballaigues, Switzerland) (10 instruments of each type), were tested using an endodontic motor set at 300 rpm and 5 N·cm. The instruments were characterized with respect to the pitch length, rake angle, and cross-sectional area. Statistical analysis was performed with analysis of variance (α = 0.05). RESULTS: The torque was significantly lower for Mtwo compared with the other 2 groups (P < .05). It was also lower for RaCe in comparison with PTU F1 (P < .05). Regarding the apical force, the RaCe instruments had lower values when compared with the Mtwo and PTU F1 instruments (P < .05). There was no statistically significant difference between the PTU F1 and Mtwo instruments (P > .05). CONCLUSIONS: The methodology allowed the cutting properties of the instruments to be assessed in terms of their different geometric characteristics. The cross-sectional design, especially in Mtwo instruments with 2 sharp edges and great chip removal capability, was a differential factor for their higher cutting action.


Assuntos
Ligas Dentárias , Níquel , Preparo de Canal Radicular/instrumentação , Titânio , Desenho de Equipamento , Humanos , Torque
9.
Arq. odontol ; 51(1): 7-13, 2015. ilus, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-850191

RESUMO

Objetivo: Avaliar a resistência à fadiga de instrumentos rotatórios ProTaper Universal após múltiplos usos clínicos com e sem movimento de pressão lateral. Material e Métodos: Trinta conjuntos de instrumentos ProTaper Universal (PTU) (Dentsply-Maillefer, Ballaigues, Suíça), calibres S1, S2, F1 e F2, em um total de 120 instrumentos, foram analisados e divididos em três grupos: Grupo com Pressão Lateral (PL), com 10 conjuntos de instrumentos, cada conjunto usado clinicamente em cinco molares inferiores e superiores (15 a 20 canais) utilizando os instrumentos de formatação com movimento de pressão lateral; e Grupo Sem Pressão Lateral (SPL), com 10 conjuntos de instrumentos, cada conjunto usado clinicamente em cinco molares inferiores e superiores (15 a 20 canais), utilizando os instrumentos de formatação sem movimento de pressão lateral. Os instrumentos dos grupos PL e SPL foram posteriormente testados em fadiga até a ruptura, juntamente com 10 conjuntos de instrumentos novos do Grupo Controle (GC). Os dados foram analisados por meio de análise de variância (α = 0,05). Resultados: Múltiplos usos clínicos causaram uma redução na vida em fadiga dos instrumentos analisados. Quando o efeito de se utilizar o movimento de pressão lateral com os instrumentos de formatação foi avaliado, houve uma tendência para o consumo da vida em fadiga ser maior para os instrumentos de S1 e S2 em PL e observou-se o mesmo para os instrumentos F1 e F2 no grupo SPL. Conclusão: O uso do movimento de pressão lateral com os instrumentos PTU S1 e S2 durante a formação de canais radiculares curvos tendeu a diminuir o consumo de vida em fadiga dos instrumentos F1 e F2. Descritores: Endodontia. Tratamento do canal radicular. Instrumentos odontológicos.


Assuntos
Instrumentos Odontológicos , Tratamento do Canal Radicular/instrumentação , Endodontia , Resistência à Tração
10.
J Endod ; 40(9): 1494-7, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25146041

RESUMO

INTRODUCTION: The aim of this study was to assess the influence of M-Wire (Dentsply Tulsa Dental Specialties, Tulsa, OK) and controlled memory technologies on the fatigue resistance of rotary nickel-titanium (NiTi) files by comparing files made using these 2 technologies with conventional NiTi files. METHODS: Files with a similar cross-sectional design and diameter were chosen for the study: new 30/.06 files of the EndoWave (EW; J. Morita Corp, Osaka, Japan), HyFlex (HF; Coltene/Whaledent, Inc, Cuyahoga Falls, OH), ProFile Vortex (PV; Dentsply Tulsa Dental Specialties, Tulsa, OK), and Typhoon (TYP; Clinician's Choice Dental Products, New Milford, CT) systems together with ProTaper Universal F2 instruments (PTU F2; Dentsply Maillefer, Ballaigues, Switzerland). The compositions and transformation temperatures of the instruments were analyzed using x-ray energy-dispersive spectroscopy and differential scanning calorimetry, whereas the mean file diameter values at 3 mm from the tip (D3) were measured using image analysis software. The average number of cycles to failure was determined using a fatigue test device. RESULTS: X-ray energy-dispersive spectroscopy analysis showed that, on average, all the instruments exhibited the same chemical composition, namely, 51% Ni-49% Ti. The PV, TYP, and HF files exhibited increased transformation temperatures. The PTU F2, PV, and TYP files had similar D3 values, which were less than those of the EW and HF files. The average number of cycles to failure values were 150% higher for the TYP files compared with the PV files and 390% higher for the HF files compared with the EW files. CONCLUSIONS: M-Wire and controlled memory technologies increase the fatigue resistance of rotary NiTi files.


Assuntos
Ligas Dentárias/química , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Varredura Diferencial de Calorimetria , Ligas Dentárias/análise , Desenho de Equipamento , Falha de Equipamento , Temperatura Alta , Humanos , Processamento de Imagem Assistida por Computador/métodos , Teste de Materiais , Metalurgia , Microscopia Eletrônica de Varredura , Níquel/análise , Óxidos/análise , Fotografação/métodos , Rotação , Espectrometria por Raios X , Estresse Mecânico , Propriedades de Superfície , Titânio/análise , Temperatura de Transição
11.
Mater Sci Eng C Mater Biol Appl ; 37: 258-63, 2014 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-24582247

RESUMO

AIM: To assess the flexibility and torsional stiffness of three nickel-titanium rotary instruments by finite element analysis and compare the numerical results with the experiment. METHODOLOGY: Mtwo (VDW, Munich, Germany) and RaCe (FKG Dentaire, La-Chaux-de-Fonds, Switzerland) size 25, .06 taper (0.25-mm tip diameter, 0.06% conicity) and PTU F1 (Dentsply Maillefer, Ballaigues, Switzerland) instruments were selected for this study. Experimental tests to assess the flexibility and torsional stiffness of the files were performed according to specification ISO 3630-1. Geometric models for finite element analysis were obtained by micro-CT scanning. Boundary conditions for the numerical analysis were based on the specification ISO 3630-1. RESULTS: A good agreement between the simulation and the experiment moment-displacement curves was found for the three types of instruments studied. RaCe exhibited the highest flexibility and PTU presented the highest torsional stiffness. Maximum values of von Mises stress were found for the PTU F1 file (1185MPa) under bending, whereas the values of von Mises stress for the three instruments were quite similar under torsion. The stress patterns proved to be different in Mtwo under bending, according to the displacement orientation. CONCLUSIONS: The favorable agreement found between simulation and experiment for the three types of instruments studied confirmed the potential of the numerical method to assess the mechanical behavior of endodontic instruments. Thus, a methodology is established to predict the failure of the instruments under bending and torsion.


Assuntos
Níquel/química , Titânio/química , Análise de Elementos Finitos , Teste de Materiais , Estresse Mecânico
12.
J Endod ; 39(11): 1444-7, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24139271

RESUMO

INTRODUCTION: The aim of this study was to evaluate the flexibility and torsional stiffness of a controlled memory (CM) nickel-titanium (NiTi) file and compare its mechanical responses with those of a superelastic NiTi file with the same geometry using finite element simulation. METHODS: A commercially available instrument with a tip size of 30 and a 0.06 taper was selected for this study. The geometric model for finite element analysis was generated by micro-computed tomographic scanning, and the data for the constitutive model of controlled memory NiTi were obtained from the literature. The numeric analysis was performed in ABAQUS (SIMULIA, Providence, RI) with boundary conditions that were based on the ISO 3630-1 specification. RESULTS: The CM NiTi file exhibited the least bending moment and maximum stress value (523 MPa) under 45° bending simulation. However, the least torsional stiffness was calculated for this same instrument. CONCLUSIONS: The higher flexibility and potential fatigue resistance of the CM NiTi files were confirmed, indicating that this new technology represents an improvement in the mechanical behavior of the rotary NiTi files.


Assuntos
Ligas Dentárias/química , Análise de Elementos Finitos , Níquel/química , Preparo de Canal Radicular/instrumentação , Titânio/química , Simulação por Computador , Módulo de Elasticidade , Humanos , Teste de Materiais , Modelos Teóricos , Maleabilidade , Aço Inoxidável/química , Estresse Mecânico , Propriedades de Superfície , Tecnologia Odontológica , Temperatura , Torção Mecânica , Microtomografia por Raio-X/métodos
13.
Braz Dent J ; 23(4): 351-6, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23207848

RESUMO

This study evaluated the protocols of sonic and vacuum irrigation regarding the capacity of debris removal from root canal systems. Canal preparations were carried out on 30 mandibular first molars using the ProTaper Universal System. Teeth were divided into two experimental groups (n=15): Group 1: sonic irrigation and Group 2: vacuum irrigation protocol. Subsequently, the mesial roots were sectioned and observed by stereomicroscopy and scanning electron microscopy. Three independent examiners evaluated images of the apical thirds according to the following scores: 1= small presence of debris, 2= moderate presence of debris, and 3= dense presence of debris. Data were analyzed with ANOVA and Kruskal-Wallis tests (α=0.05). Comparison among the groups revealed that at the apical third, the root halves of Group 1 had significantly less surface debris (p=0.002) than those of Group 2. However, at 2 mm from the working length, Group 2's specimens showed less remaining debris in approximately 75% of the analyzed root canals. At the whole apical third, the sonic irrigation protocol removed significantly more debris than the vacuum protocol. However, in the region at 2 mm from the working length, the second irrigation method demonstrated a better performance.


Assuntos
Cavidade Pulpar/ultraestrutura , Irrigantes do Canal Radicular/uso terapêutico , Preparo de Canal Radicular/métodos , Ápice Dentário/ultraestrutura , Dentina/ultraestrutura , Ácido Edético/administração & dosagem , Ácido Edético/uso terapêutico , Humanos , Processamento de Imagem Assistida por Computador/métodos , Microscopia , Microscopia Eletrônica de Varredura , Irrigantes do Canal Radicular/administração & dosagem , Preparo de Canal Radicular/instrumentação , Camada de Esfregaço , Cloreto de Sódio , Hipoclorito de Sódio/administração & dosagem , Hipoclorito de Sódio/uso terapêutico , Sonicação/instrumentação , Sonicação/métodos , Irrigação Terapêutica/instrumentação , Irrigação Terapêutica/métodos , Vácuo
14.
Braz. dent. j ; Braz. dent. j;23(4): 351-356, 2012. ilus, tab
Artigo em Inglês | LILACS | ID: lil-658009

RESUMO

This study evaluated the protocols of sonic and vacuum irrigation regarding the capacity of debris removal from root canal systems. Canal preparations were carried out on 30 mandibular first molars using the ProTaper Universal System. Teeth were divided into two experimental groups (n=15): Group 1: sonic irrigation and Group 2: vacuum irrigation protocol. Subsequently, the mesial roots were sectioned and observed by stereomicroscopy and scanning electron microscopy. Three independent examiners evaluated images of the apical thirds according to the following scores: 1= small presence of debris, 2= moderate presence of debris, and 3= dense presence of debris. Data were analyzed with ANOVA and Kruskal-Wallis tests (α=0.05). Comparison among the groups revealed that at the apical third, the root halves of Group 1 had significantly less surface debris (p=0.002) than those of Group 2. However, at 2 mm from the working length, Group 2's specimens showed less remaining debris in approximately 75% of the analyzed root canals. At the whole apical third, the sonic irrigation protocol removed significantly more debris than the vacuum protocol. However, in the region at 2 mm from the working length, the second irrigation method demonstrated a better performance.


Este estudo avaliou protocolos de irrigação sônica e a vácuo em relação à capacidade de remoção de debris do sistema de canais radiculares. Trinta primeiros molares mandibulares tiveram seus canais radiculares preparados pela utilização do Sistema ProTaper Universal. Os dentes foram divididos em dois grupos experimentais (n=15): Grupo 1: protocolo de irrigação sônica, e Grupo 2: protocolo de irrigação a vácuo. Posteriormente, as raízes mesiais foram seccionadas e observadas em lupa estereoscópica e microscopia eletrônica de varredura. Três examinadores independentes avaliaram as imagens do terço apical de acordo com as seguintes pontuações: 1. pequena presença de debris; 2: moderada presença de debris; e 3. densa presença de debris. Os dados foram analisados pelos testes estatísticos ANOVA e Kruskal-Wallis (α=0,05). A comparação entre os grupos revelou que, no terço apical, as hemissecções radiculares do Grupo 1 apresentaram debris remanescentes de forma significativamente menor (p=0,002) do que as do Grupo 2. No entanto, a 2 mm do comprimento de trabalho, as amostras do Grupo 2 mostraram menos debris remanescentes em aproximadamente 75% dos canais radiculares analisados. Considerando todo o terço apical, o protocolo de irrigação sônica removeu significativamente mais debris do que o protocolo de irrigação a vácuo. No entanto, na região a 2 mm do comprimento de trabalho, o segundo método de irrigação demonstrou um melhor desempenho.


Assuntos
Humanos , Cavidade Pulpar/ultraestrutura , Irrigantes do Canal Radicular/uso terapêutico , Preparo de Canal Radicular/métodos , Ápice Dentário/ultraestrutura , Dentina/ultraestrutura , Ácido Edético/administração & dosagem , Ácido Edético/uso terapêutico , Processamento de Imagem Assistida por Computador/métodos , Microscopia , Microscopia Eletrônica de Varredura , Irrigantes do Canal Radicular/administração & dosagem , Preparo de Canal Radicular/instrumentação , Camada de Esfregaço , Cloreto de Sódio , Hipoclorito de Sódio/administração & dosagem , Hipoclorito de Sódio/uso terapêutico , Sonicação/instrumentação , Sonicação/métodos , Irrigação Terapêutica/instrumentação , Irrigação Terapêutica/métodos , Vácuo
15.
J Endod ; 37(8): 1124-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21763906

RESUMO

INTRODUCTION: The purpose of this study was to evaluate the torsional behavior of rotary ProTaper Universal instruments after multiple clinical uses with and without lateral pressure motion. METHODS: Thirty sets of ProTaper Universal instruments were divided into 3 groups (n = 10): control group (CG) involving new instruments tested in torsion on the basis of ISO 3630-1, lateral pressure (LP) group involving instruments that were clinically used on 5 molars by using the shaping instruments S1 and S2 with lateral pressure motion, and no lateral pressure (NLP) group involving instruments that were clinically used on 5 molars without lateral pressure motion. The instruments in the LP and NLP groups were subsequently tested in torsion. Data were analyzed by using analysis of variance (α = 0.05). RESULTS: Multiple clinical uses caused a reduction in the maximum torque in the analyzed instruments. When the effect of using lateral pressure motion with the shaping instruments was assessed, a tendency of reduction in the maximum torque for the S1 and S2 instruments and of increase for the F1 and F2 instruments was observed in the group with lateral pressure motion. CONCLUSIONS: The use of lateral pressure motion with the shaping instruments S1 and S2 tended to produce smaller decreases in the torsional resistance of the finishing instruments F1 and F2.


Assuntos
Análise do Estresse Dentário , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Análise de Variância , Ligas Dentárias , Instrumentos Odontológicos , Reutilização de Equipamento , Humanos , Dente Molar , Níquel , Pressão , Estatísticas não Paramétricas , Titânio , Torção Mecânica
16.
J Appl Oral Sci ; 18(1): 44-9, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-20379681

RESUMO

OBJECTIVE: This study identified which regions of ProTaper instruments work during curved root canal instrumentation. MATERIAL AND METHODS: Twelve ProTaper instruments of each type, S1, S2, F1, and F2, were assessed morphometrically by measuring tip angle, tip length, tip diameter, length of each pitch along the cutting blades, and instrument diameter at each millimeter from the tip. Curved canals in resin blocks were explored with manual stainless steel files and prepared with ProTaper instruments until the apical end following four distinct sequences of instrumentation: S1; S1 and S2; S1, S2, and F1; S1, S2, F1, and F2. Image analysis was employed for measuring canal diameters. The diameters of the canals and diameters of the instruments were compared. Data were analyzed by one-way ANOVA and Tukey's test. RESULTS: No statistically significant difference was found between the canals and instrument diameters (p>0.05). The largest diameters in the end-point of the instrumented canals were obtained with F1 and F2 instruments and in the initial and middle thirds with S1 and S2 instruments. CONCLUSIONS: All instruments worked at the tip and along their cutting blades, being susceptible to fail by torsion, fatigue, or the combination of these two mechanisms.


Assuntos
Preparo de Canal Radicular/instrumentação , Ligas Dentárias/química , Cavidade Pulpar , Desenho de Equipamento , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Modelos Anatômicos , Níquel/química , Fotografação , Resinas Sintéticas , Aço Inoxidável/química , Propriedades de Superfície , Titânio/química
17.
J Endod ; 36(4): 741-4, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20307756

RESUMO

INTRODUCTION: The purpose of this study was to compare the flexural fatigue and torsional resistance of ProFile GT and GT Series X instruments, taking into account their structural and dimensional characteristics. METHODS: Instrument diameter at each millimeter from the tip and pitch length were the dimensional parameters measured. Chemical composition was determined by energy-dispersive x-ray spectroscopy and phase constitution by x-ray diffraction. Vickers microhardness measurements were performed to assess instrument strength. One group of 20/.06 GT and GTX instruments (n = 10 each) was tested until failure in a flexural fatigue test device, whereas another group of 20/.04 files (n = 10 each) was tested in torsion based on ISO 3630-1. RESULTS: GT and GTX instruments showed approximately the same chemical composition, namely 51at%Ni-49at%Ti (56wt%Ni-44wt%Ti) and contained mainly the beta-phase. GTX instruments showed higher intensity x-ray diffraction peaks and a statistically higher Vickers microhardness. There was a significant decrease in the diameter of GTX in relation to GT instruments from D6 to D9 for 20/.04 instruments and from D4 to D7 for 20/.06 instruments. Pitch length increased along the active part of both instruments, with a steeper increase in GTX. In general, GT Series X instruments were significantly more resistant to flexural fatigue than were similar GT instruments (p < 0.001) but exhibited lower torsional strength (p < 0.001). CONCLUSIONS: Different structural and dimensional characteristics were found in GTX instruments in comparison with GT instruments; this is probably the cause for their higher flexural fatigue resistance and lower torsional strength.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Ligas Dentárias , Análise do Estresse Dentário , Elasticidade , Desenho de Equipamento , Falha de Equipamento , Dureza , Níquel , Espectrometria por Raios X , Titânio , Torção Mecânica
18.
J. appl. oral sci ; J. appl. oral sci;18(1): 44-49, Jan.-Feb. 2010. ilus
Artigo em Inglês | LILACS | ID: lil-545026

RESUMO

OBJECTIVE: This study identified which regions of ProTaper instruments work during curved root canal instrumentation. MATERIAL AND METHODS: Twelve ProTaper instruments of each type, S1, S2, F1, and F2, were assessed morphometrically by measuring tip angle, tip length, tip diameter, length of each pitch along the cutting blades, and instrument diameter at each millimeter from the tip. Curved canals in resin blocks were explored with manual stainless steel files and prepared with ProTaper instruments until the apical end following four distinct sequences of instrumentation: S1; S1 and S2; S1, S2, and F1; S1, S2, F1, and F2. Image analysis was employed for measuring canal diameters. The diameters of the canals and diameters of the instruments were compared. Data were analyzed by one-way ANOVA and Tukey's test. RESULTS: No statistically significant difference was found between the canals and instrument diameters (p>0.05). The largest diameters in the end-point of the instrumented canals were obtained with F1 and F2 instruments and in the initial and middle thirds with S1 and S2 instruments. CONCLUSIONS: All instruments worked at the tip and along their cutting blades, being susceptible to fail by torsion, fatigue, or the combination of these two mechanisms.


Assuntos
Humanos , Preparo de Canal Radicular/instrumentação , Cavidade Pulpar , Ligas Dentárias/química , Desenho de Equipamento , Teste de Materiais , Microscopia Eletrônica de Varredura , Modelos Anatômicos , Níquel/química , Fotografação , Resinas Sintéticas , Propriedades de Superfície , Aço Inoxidável/química , Titânio/química
19.
J Endod ; 35(1): 113-6, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19084138

RESUMO

The purpose of this study was to assess how the geometric and dimensional changes made on ProTaper Universal (PTU) instruments in comparison with ProTaper (PT) instruments affected their flexibility and torsional strength. Two groups (n = 12) of each type of shaping (S1 and S2) and finishing (F1, F2, and F3) for both PT and PTU instruments were employed. Tip angle, instrument diameter at each millimeter, and cross-sectional area at 3 mm from the tip were the dimensional parameters measured. Flexibility and torsional strength of each instrument (n = 12) were assessed according to specification ISO 3630-1. Data were analyzed using analysis of variance (alpha = 0.05). Flexibility increased for S1 and F1 PTU instruments and decreased for F2 and F3, whereas torsional resistance increased for S2, F2, and F3. Changes in tip angle were accompanied by variation of tip geometry in all instruments.


Assuntos
Instrumentos Odontológicos , Preparo de Canal Radicular/instrumentação , Ligas Dentárias , Análise do Estresse Dentário , Microscopia Eletrônica de Varredura , Níquel , Maleabilidade , Titânio , Torção Mecânica
20.
Artigo em Inglês | MEDLINE | ID: mdl-16997104

RESUMO

OBJECTIVE: Evaluate the effect of 5.25% NaOCl on the surface characteristics and fatigue resistance of ProFile. STUDY DESIGN: Eighty new ProFile instruments were divided into 1 control group (CG) and 3 experimental groups (EG1, EG2, EG3). Instruments of EG1 were immersed in 5.25% NaOCl for 24 hours. Instruments of EG2 and EG3 shaped 10 curved root canals, using, respectively, deionized water and 5.25% NaOCl as irrigants. Surface characteristics were observed by scanning electron microscopy. All instruments were then submitted to fatigue tests. Two-way ANOVA tests were employed to compare the results. RESULTS: Surface characteristics showed no alteration after the immersion tests. The fatigue resistance of instruments in EG2 and EG3 was significantly lower than in CG and EG1. CONCLUSIONS: Immersion of ProFile in 5.25% NaOCl for 24 hours had no influence on surface characteristics and fatigue resistance. Simulated clinical use was a decisive factor in the decrease of fatigue life.


Assuntos
Ligas Dentárias , Instrumentos Odontológicos , Níquel , Irrigantes do Canal Radicular , Preparo de Canal Radicular/instrumentação , Hipoclorito de Sódio , Titânio , Análise de Variância , Corrosão , Análise do Estresse Dentário , Falha de Equipamento , Reutilização de Equipamento , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA