Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Tipo de estudo
Intervalo de ano de publicação
1.
Ground Water ; 52(1): 105-17, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23473020

RESUMO

Reverse water-level fluctuations (RWFs), a phenomenon in which water levels rise briefly in response to pumping, were detected in monitoring wells in a fractured siliciclastic aquifer system near a deep public supply well. The magnitude and timing of RWFs provide important information that can help interpret aquifer hydraulics near pumping wells. A RWF in a well is normally attributed to poroelastic coupling between the solid and fluid components in an aquifer system. In addition to revealing classical pumping-induced poroelastic RWFs, data from pressure transducers located at varying depths and distances from the public supply well suggest that the RWFs propagate rapidly through fractures to influence wells hundreds of meters from the pumping well. The rate and cycling frequency of pumping is an important factor in the magnitude of RWFs. The pattern of RWF propagation can be used to better define fracture connectivity in an aquifer system. Rapid, cyclic head changes due to RWFs may also serve as a mechanism for contaminant transport.


Assuntos
Monitoramento Ambiental/métodos , Água Subterrânea/análise , Poços de Água , Wisconsin
2.
Ground Water ; 50(5): 726-35, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22320852

RESUMO

Subsurface heterogeneity in hydraulic properties and processes is a fundamental challenge in hydrogeology. We have developed an improved method of borehole dilution testing for hydrostratigraphic characterization, in which distributed temperature sensing (DTS) is used to monitor advective heat movement. DTS offers many advantages over conventional technologies including response times in the order of seconds rather than minutes, the ability to profile temperature synoptically in a well without disturbing the fluid column, sensitivity to a wider range of flow rates than conventional spinner and heat pulse flow meters, and the ease of interpretation. Open-well thermal dilution tests in two multiaquifer wells near Madison, Wisconsin, provided detailed information on the borehole flow regimes, including flow rates and the locations of inflows from both fractures and porous media. The results led to an enhanced understanding of flow in a hydrostratigraphic unit previously conceptualized as homogenous and isotropic.


Assuntos
Monitoramento Ambiental/métodos , Movimentos da Água , Temperatura
3.
Ground Water ; 48(6): 903-12, 2010.
Artigo em Inglês | MEDLINE | ID: mdl-19840125

RESUMO

Arsenic concentrations exceeding the U.S. EPA's 10 µg/L standard are common in glacial aquifers in the midwestern United States. Previous studies have indicated that arsenic occurs naturally in these aquifers in association with metal-(hydr)oxides and is released to groundwater under reducing conditions generated by microbial oxidation of organic matter. Despite this delineation of the arsenic source and mechanism of arsenic mobilization, identification of arsenic-impacted aquifers is hindered by the heterogeneous and discontinuous nature of glacial sediments. In much of the Midwest, the hydrostratigraphy of glacial deposits is not sufficiently characterized to predict where elevated arsenic concentrations are likely to occur. This case study from southeast Wisconsin presents a detailed characterization of local stratigraphy, hydrostratigraphy, and geochemistry of the Pleistocene glacial deposits and underlying Silurian dolomite. Analyses of a single core, water chemistry data, and well construction reports enabled identification of two aquifers separated by an organic-rich aquitard. The upper, unconfined aquifer provides potable water, whereas arsenic generally exceeds 10 µg/L in the deeper aquifer. Although coring and detailed hydrostratigraphic characterization are often considered impractical, our results demonstrate that a single core improved interpretation of the complex lithology and hydrostratigraphy. This detailed characterization of hydrostratigraphy facilitated development of well construction guidelines and lays the ground work for further studies of the complex interactions among aquifer sediments, hydrogeology, water chemistry, and microbiology that lead to elevated arsenic in groundwater.


Assuntos
Arsênio/análise , Sedimentos Geológicos/química , Abastecimento de Água/análise , Monitoramento Ambiental , Sedimentos Geológicos/análise , Oxirredução , Microbiologia da Água , Poluentes Químicos da Água/análise , Wisconsin
4.
J Environ Qual ; 38(1): 149-56, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19141804

RESUMO

The detection of pharmaceuticals and other organic wastewater contaminants (OWCs) in ground water and surface-water bodies has raised concerns about the possible ecological impacts of these compounds on nontarget organisms. On-site wastewater treatment systems represent a potentially significant route of entry for organic contaminants to the environment. In this study, effluent samples were collected and analyzed from conventional septic systems and from systems using advanced treatment technologies. Six of 13 target compounds were detected in effluent from at least one septic system. Caffeine, paraxanthine, and acetaminophen were the most frequently detected compounds, and estrogenic activity was detected in 14 of 15 systems. The OWC concentrations were significantly lower in effluent after sand filtration (p < 0.01) or aerobic treatment (p < 0.05) as compared with effluent that had not undergone advanced treatment. In general, concentrations in conventional systems were comparable to those measured in previous studies of municipal wastewater treatment plant (WWTP) influent, and concentrations in systems after advanced treatment were comparable to previously measured concentrations in WWTP effluent. These data indicate that septic systems using advanced treatment can reduce OWCs in treated effluent to similar concentrations as municipal WWTPs.


Assuntos
Compostos Orgânicos/análise , Gerenciamento de Resíduos/métodos , Poluentes Químicos da Água/análise , Acetaminofen/análise , Cafeína/análise , Cromatografia Líquida , Disruptores Endócrinos/análise , Espectrometria de Massas em Tandem , Teofilina/análise , Fatores de Tempo
5.
Ground Water ; 43(6): 787-95, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-16324000

RESUMO

Previous site-specific studies designed to assess the impacts of unsewered subdivisions on ground water quality have relied on upgradient monitoring wells or very limited background data to characterize conditions prior to development. In this study, an extensive monitoring program was designed to document ground water conditions prior to construction of a rural subdivision in south-central Wisconsin. Previous agricultural land use has impacted ground water quality; concentrations of chloride, nitrate-nitrogen, and atrazine ranged from below the level of detection to 296 mg/L, 36 mg/L, and 0.8 microg/L, respectively, and were highly variable from well to well and through time. Seasonal variations in recharge, surface topography, aquifer heterogeneities, surficial loading patterns, and well casing depth explain observed variations in ground water chemistry. This variability would not have been detected if background conditions were determined from only a few monitoring wells or inferred from wells located upgradient of the subdivision site. This project demonstrates the importance of characterizing both ground water quality and chemical variability prior to land-use change to detect any changes once homes are constructed.


Assuntos
Poluentes Químicos da Água/análise , Abastecimento de Água/análise , Agricultura , Atrazina/análise , Cloretos/análise , Monitoramento Ambiental , Herbicidas/análise , Habitação , Nitratos/análise , Resíduos de Praguicidas/análise , Estações do Ano , Esgotos , Sódio/análise , Fatores de Tempo , Wisconsin
6.
Ground Water ; 42(5): 747-59, 2004.
Artigo em Inglês | MEDLINE | ID: mdl-15457797

RESUMO

Flow from some springs in former glacial lakebeds of the Upper Midwest is extremely steady throughout the year and does not increase significantly after precipitation events or seasonal recharge. Analytical and simplified numerical models of spring systems were used to determine whether preferential ground water flow through high-permeability features in shallow sandstone aquifers could produce typical values of spring discharge and the unusually steady rates of spring flow. The analytical model is based on a one-dimensional solution for periodic ground water flow. Solutions to this model suggest that it is unlikely that a periodic forcing due to seasonal variations in areal recharge would propagate to springs in a setting where high-permeability features exist. The analytical model shows that the effective length of the aquifer, or the length of flowpaths to a spring, and the total transmissivity of the aquifer have the greatest potential to impact the nature of spring flow in this setting. The numerical models show that high-permeability features can influence the magnitude of spring flow and the results demonstrate that the lengths of ground water flowpaths increase when high-permeability features are explicitly modeled, thus decreasing the likelihood for temporal variations in spring flow.


Assuntos
Modelos Teóricos , Movimentos da Água , Abastecimento de Água , Fenômenos Geológicos , Geologia , Permeabilidade , Estações do Ano
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...