Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Geriatr Cardiol ; 11(1): 44-9, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24748881

RESUMO

BACKGROUND: Severely calcified coronary lesions respond poorly to balloon angioplasty, resulting in incomplete and asymmetrical stent expansion. Therefore, adequate plaque modification prior to drug-eluting stent (DES) implantation is the key for calcified lesion treatment. This study was to evaluate the safety and efficacy of cutting balloon angioplasty for severely calcified coronary lesions. METHODS: Ninety-two consecutive patients with severely calcified lesions (defined as calcium arc ≥ 180° calcium length ratio ≥ 0.5) treated with balloon dilatation before DES implantation were randomly divided into two groups based on the balloon type: 45 patients in the conventional balloon angioplasty (BA) group and 47 patients in the cutting balloon angioplasty (CB) group. Seven cases in BA group did not satisfactorily achieve dilatation and were transferred into the CB group. Intravascular ultrasound (IVUS) was performed before balloon dilatation and after stent implantation to obtain qualitative and quantitative lesion characteristics and evaluate the stent, including minimum lumen cross-sectional area (CSA), calcified arc and length, minimum stent CSA, stent apposition, stent symmetry, stent expansion, vessel dissection, and branch vessel jail. In-hospital, 1-month, and 6-month major adverse cardiac events (MACE) were reported. RESULTS: There were no statistical differences in clinical characteristics between the two groups, including calcium arc (222.2° ± 22.2° vs. 235.0° ± 22.1°, P = 0.570), calcium length ratio (0.67 ± 0.06 vs. 0.77 ± 0.05, P = 0.130), and minimum lumen CSA before PCI (2.59 ± 0.08 mm(2) vs. 2.52 ± 0.08 mm(2), P = 0.550). After stent implantation, the final minimum stent CSA (6.26 ± 0.40 mm(2) vs. 5.03 ± 0.33 mm(2); P = 0.031) and acute lumen gain (3.74 ± 0.38 mm(2) vs. 2.44 ± 0.29 mm(2), P = 0.015) were significantly larger in the CB group than that of the BA group. There were not statistically differences in stent expansion, stent symmetry, incomplete stent apposition, vessel dissection and branch vessel jail between two groups. The 30-day and 6-month MACE rates were also not different. CONCLUSIONS: Cutting balloon angioplasty before DES implantation in severely calcified lesions appears to be more efficacies including significantly larger final stent CSA and larger acute lumen gain, without increasing complications during operations and the MACE rate in 6-month.

2.
Nan Fang Yi Ke Da Xue Xue Bao ; 30(5): 1063-5, 2010 May.
Artigo em Chinês | MEDLINE | ID: mdl-20501394

RESUMO

OBJECTIVE: To evaluate neointimal proliferation following placement of a new drug-eluting stent (BUMA) by optical coherence tomography (OCT). METHODS: Twenty-two patients with coronary artery disease were randomized into BUMA group (n=15) and Endeavor group (n=7) and underwent OCT imaging after 9 months of stent implantation. RESULTS: The neointima hyperplasia (NIH) thickness in BUMA group were significantly smaller than that in endeavor group (0.220-/+0.140 mm vs 0.269-/+0.207 mm, P<0.001), and the uncovered Struts were significantly lower in BUMA group than in Endeavor group (5.65% vs 6.56%, P<0.0001). The luminal late loss in BUMA group was also significantly lower (34.87-/+11.50 vs 40.82-/+18.53, P=0.025). CONCLUSION: BUMA stent is safe and effective for treatment of coronary artery disease.


Assuntos
Doença da Artéria Coronariana/terapia , Vasos Coronários/patologia , Stents Farmacológicos , Tomografia de Coerência Óptica , Túnica Íntima/patologia , Angioplastia Coronária com Balão/efeitos adversos , Proliferação de Células , Doença da Artéria Coronariana/patologia , Stents Farmacológicos/efeitos adversos , Humanos , Estudos Prospectivos
3.
Zhonghua Xin Xue Guan Bing Za Zhi ; 37(7): 585-9, 2009 Jul.
Artigo em Chinês | MEDLINE | ID: mdl-19961724

RESUMO

OBJECTIVE: To evaluate the characteristic of late stent malposition after drug-eluting stent implantation by optical coherence tomography (OCT). METHODS: The study comprised of 32 patients (target vessels: 51, total stents: 71) underwent drug eluting stent implantation one year ago [average (14.8 +/- 5.2) months]. OCT images of the stent were analyzed at interval of 0.5 mm. The stent malposition was detected, the thickness of intima and gap between the stent strut and vessel wall were measured. RESULTS: Stent malposition was detected in 7 patients without clinical cardiac events, including positive remodeling (n = 4), overlapping stents (n = 1) and stent struts covered with thrombus (n = 2). Stent strut apposition with complete intima coverage was about 97.6%, stent struts malposition was 2.4% including half of struts located at the ostium of side branch. The intima coverage of stent struts is similar between the struts at the side branch and others [(0.06 +/- 0.05) mm vs. (0.05 +/- 0.03) mm, P > 0.05]. CONCLUSION: The causes of late stent malposition include the primary malposition after stent implantation, positive remodeling, overlapping stents and stent struts located at the ostium of side branch. Thinner intima coverage was also observed on the stent struts with malposition.


Assuntos
Stents Farmacológicos , Tomografia de Coerência Óptica , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...