Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem Lab Med ; 61(10): 1708-1718, 2023 09 26.
Artigo em Inglês | MEDLINE | ID: mdl-37021544

RESUMO

OBJECTIVES: Knowledge of the stability of analytes in clinical specimens is a prerequisite for proper transport and preservation of samples to avoid laboratory errors. The new version of ISO 15189:2022 and the European directive 2017/746 increase the requirements on this topic for manufacturers and laboratories. Within the project to generate a stability database of European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) Working Group Preanalytical Phase (WG-PRE), the need to standardise and improve the quality of published stability studies has been detected, being a manifest deficit the absence of international guidelines for the performance of stability studies on clinical specimens. METHODS: These recommendations have been developed and summarised by consensus of the WG-PRE and are intended primarily to improve the quality of sample stability claims included in information for users provided by assay supplier companies, according to the requirements of the new European regulations and standards for accreditation. RESULTS: This document provides general recommendations for the performance of stability studies, oriented to the estimation of instability equations in the usual working conditions, allowing flexible adaptation of the maximum permissible error specifications to obtain stability limits adapted to the intended use. CONCLUSIONS: We present this recommendation based on the opinions of the EFLM WG-PRE group for the standardisation and improvement of stability studies, with the intention to improve the quality of the studies and the transferability of their results to laboratories.


Assuntos
Química Clínica , Fase Pré-Analítica , Humanos , Laboratórios , Padrões de Referência , Acreditação
2.
Clin Chem ; 67(7): 1008-1018, 2021 07 06.
Artigo em Inglês | MEDLINE | ID: mdl-34136904

RESUMO

BACKGROUND: Conventional HER2-targeting therapies improve outcomes for patients with HER2-positive breast cancer (BC), defined as tumors showing HER2 protein overexpression by immunohistochemistry and/or ERBB2 gene amplification determined by in situ hybridization (ISH). Emerging HER2-targeting compounds show benefit in some patients with neither HER2 protein overexpression nor ERBB2 gene amplification, creating a need for new assays to select HER2-low tumors for treatment with these compounds. We evaluated the analytical performance of a targeted mass spectrometry-based assay for quantifying HER2 protein in formalin-fixed paraffin-embedded (FFPE) and frozen BC biopsies. METHODS: We used immunoaffinity-enrichment coupled to multiple reaction monitoring-mass spectrometry (immuno-MRM-MS) to quantify HER2 protein (as peptide GLQSLPTHDPSPLQR) in 96 frozen and 119 FFPE BC biopsies. We characterized linearity, lower limit of quantification (LLOQ), and intra- and inter-day variation of the assay in frozen and FFPE tissue matrices. We determined concordance between HER2 immuno-MRM-MS and predicate immunohistochemistry and ISH assays and examined the benefit of multiplexing the assay to include proteins expressed in tumor subcompartments (e.g., stroma, adipose, lymphocytes, epithelium) to account for tissue heterogeneity. RESULTS: HER2 immuno-MRM-MS assay linearity was ≥103, assay coefficient of variation was 7.8% (FFPE) and 5.9% (frozen) for spiked-in analyte, and 7.7% (FFPE) and 7.9% (frozen) for endogenous measurements. Immuno-MRM-MS-based HER2 measurements strongly correlated with predicate assay HER2 determinations, and concordance was improved by normalizing to glyceraldehyde-3-phosphate dehydrogenase. HER2 was quantified above the LLOQ in all tumors. CONCLUSIONS: Immuno-MRM-MS can be used to quantify HER2 in FFPE and frozen BC biopsies, even at low HER2 expression levels.


Assuntos
Neoplasias da Mama , Biomarcadores Tumorais/genética , Neoplasias da Mama/patologia , Feminino , Formaldeído/química , Humanos , Espectrometria de Massas/métodos , Inclusão em Parafina , Receptor ErbB-2/análise , Fixação de Tecidos/métodos
3.
J Proteome Res ; 15(8): 2717-28, 2016 08 05.
Artigo em Inglês | MEDLINE | ID: mdl-27462933

RESUMO

Despite a clinical, economic, and regulatory imperative to develop companion diagnostics, precious few new biomarkers have been successfully translated into clinical use, due in part to inadequate protein assay technologies to support large-scale testing of hundreds of candidate biomarkers in formalin-fixed paraffin-embedded (FFPE) tissues. Although the feasibility of using targeted, multiple reaction monitoring mass spectrometry (MRM-MS) for quantitative analyses of FFPE tissues has been demonstrated, protocols have not been systematically optimized for robust quantification across a large number of analytes, nor has the performance of peptide immuno-MRM been evaluated. To address this gap, we used a test battery approach coupled to MRM-MS with the addition of stable isotope-labeled standard peptides (targeting 512 analytes) to quantitatively evaluate the performance of three extraction protocols in combination with three trypsin digestion protocols (i.e., nine processes). A process based on RapiGest buffer extraction and urea-based digestion was identified to enable similar quantitation results from FFPE and frozen tissues. Using the optimized protocols for MRM-based analysis of FFPE tissues, median precision was 11.4% (across 249 analytes). There was excellent correlation between measurements made on matched FFPE and frozen tissues, both for direct MRM analysis (R(2) = 0.94) and immuno-MRM (R(2) = 0.89). The optimized process enables highly reproducible, multiplex, standardizable, quantitative MRM in archival tissue specimens.


Assuntos
Células/química , Proteômica/métodos , Biomarcadores/análise , Formaldeído , Humanos , Marcação por Isótopo , Espectrometria de Massas/métodos , Inclusão em Parafina , Fixação de Tecidos , Preservação de Tecido/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...