1.
J Pediatr Orthop ; 23(4): 478-83, 2003.
Artigo em Inglês | MEDLINE | ID: mdl-12826946

RESUMO

The purpose of this study was to determine whether exposure to pulsed electromagnetic field (PEMF) would shorten the healing time of regenerate bone in a rabbit tibial distraction model. Beginning 1 day after surgery, mid-shaft tibial osteotomies, stabilized with external fixators, were distracted 0.25 mm twice daily for 21 days and received either no exposure (sham control) or 1 hour per day exposure to low-amplitude, low-frequency PEMF. Tibiae were tested for torsional strength after 9, 16, and 23 days post-distraction. PEMF-treated tibiae were significantly stronger than shams at all three time points. By 16 days post-distraction, the PEMF group had achieved biomechanical strength essentially equivalent to intact bone. Shams did not achieve normal biomechanical strength even after 23 days post-distraction. In this tibial distraction model, short daily PEMF exposures accelerated consolidation of regenerate bone. Clinical usefulness awaits testing.


Assuntos
Regeneração Óssea , Campos Eletromagnéticos , Osteogênese por Distração , Tíbia/cirurgia , Animais , Fenômenos Biomecânicos , Masculino , Coelhos , Radiografia , Tíbia/diagnóstico por imagem