1.
BMC Oral Health ; 24(1): 322, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38468251

RESUMO

BACKGROUND: This animal study sought to evaluate two novel nanomaterials for pulpotomy of primary teeth and assess the short-term pulpal response and hard tissue formation in dogs. The results were compared with mineral trioxide aggregate (MTA). METHODS: This in vivo animal study on dogs evaluated 48 primary premolar teeth of 4 mongrel female dogs the age of 6-8 weeks, randomly divided into four groups (n = 12). The teeth underwent complete pulpotomy under general anesthesia. The pulp tissue was capped with MCM-48, MCM-48/Hydroxyapatite (HA), MTA (positive control), and gutta-percha (negative control), and the teeth were restored with intermediate restorative material (IRM) paste and amalgam. After 4-6 weeks, the teeth were extracted and histologically analyzed to assess the pulpal response to the pulpotomy agent. RESULTS: The data were analyzed using the Kruskal‒Wallis, Fisher's exact, Spearman's, and Mann‒Whitney tests. The four groups were not significantly different regarding the severity of inflammation (P = 0.53), extent of inflammation (P = 0.72), necrosis (P = 0.361), severity of edema (P = 0.52), extent of edema (P = 0.06), or connective tissue formation (P = 0.064). A significant correlation was noted between the severity and extent of inflammation (r = 0.954, P < 0.001). The four groups were significantly different regarding the frequency of bone formation (P = 0.012), extent of connective tissue formation (P = 0.047), severity of congestion (P = 0.02), and extent of congestion (P = 0.01). No bone formation was noted in the gutta-percha group. The type of newly formed bone was not significantly different among the three experimental groups (P = 0.320). CONCLUSION: MCM-48 and MCM-48/HA are bioactive nanomaterials that may serve as alternatives for pulpotomy of primary teeth due to their ability to induce hard tissue formation. The MCM-48 and MCM-48/HA mesoporous silica nanomaterials have the potential to induce osteogenesis and tertiary (reparative) dentin formation.


Assuntos
Capeamento da Polpa Dentária , Dentina Secundária , Animais , Cães , Feminino , Dente Pré-Molar , Polpa Dentária/patologia , Capeamento da Polpa Dentária/métodos , Dentina Secundária/patologia , Combinação de Medicamentos , Edema , Guta-Percha , Hidroxiapatitas , Inflamação/patologia , Óxidos/farmacologia , Óxidos/uso terapêutico , Dente Decíduo
2.
Radiology ; 224(3): 838-44, 2002 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-12202723

RESUMO

PURPOSE: To test the hypothesis that computed tomographic (CT) scanning during optimal electrocardiographic (EKG) triggering can minimize image motion artifact and reduce interexamination variation of coronary arterial calcification (CAC) score at electron-beam CT. MATERIALS AND METHODS: Two hundred patients underwent electron-beam CT once and again 5 minutes later to evaluate interexamination variability of CAC score. Group 1 (104 patients) underwent scanning with use of an optimal EKG-triggering protocol (EKG triggering performed individually at the time of least coronary arterial motion during the cardiac cycle); group 2 (96 patients) underwent scanning with use of conventional 80% R-R interval triggering (the most common protocol with the electron-beam CT scanner). Interexamination, intraobserver, and interobserver variations of CAC measurements were compared between groups by using unpaired t tests for both Agatston and volumetric scores (in square millimeters). RESULTS: Coronary arterial motion artifacts were found in 26% (27 of 104) versus 80% (77 of 96) of patients in groups 1 and 2, respectively (P <.0001). Intraobserver, interobserver, and interexamination variabilities in volumetric score were derived, with values of 1.2%, 9.2%, and 15.9% in group 1 and 2.1%, 11.3%, and 25.9% in group 2, respectively. Interexamination variabilities in both Agatston and volumetric score were significantly reduced with individualized EKG triggering, as compared with conventional triggering (P <.05), but intra- and interobserver variabilities were not (P >.05). CONCLUSION: Optimal EKG triggering improves the reproducibility of CAC measurement by reducing coronary arterial motion artifacts.


Assuntos
Cálcio/análise , Vasos Coronários/química , Eletrocardiografia , Tomografia Computadorizada por Raios X/métodos , Artérias/química , Artefatos , Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Humanos , Variações Dependentes do Observador
3.
Acad Radiol ; 9(6): 654-61, 2002 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-12061739

RESUMO

RATIONALE AND OBJECTIVES: The authors performed this study to investigate the causes of interscan variability of coronary artery calcium measurements at electron-beam computed tomography (CT). MATERIALS AND METHODS: Two sets of electron-beam CT scans were obtained in 298 consecutive patients who underwent electron-beam CT to screen for coronary artery calcium. Interscan variations of coronary artery calcium characteristics and the effects of heart rate, electrocardiographic (ECG) triggering method, image noise, and coronary motion on interscan variability were analyzed. RESULTS: The interscan mean variabilities were 21.6% (median, 11.7%) and 17.8% (median, 10.8%) with the Agatston and volumetric score, respectively (P < .01). Variability decreased with increasing calcification score (34.6% for a score of 11-50 and 9.4% for a score of 400-1,000, P < .0001). The absolute difference in Agatston score between scans was 44.1 +/- 95.6. The correlation coefficient between the first and second sets of scans was 0.99 (P < .0001). Lower interscan variability was found in younger patients (<60 years), patients with stable heart rates (heart rate changing less than 10 beats per minute during scanning), patients with no visible coronary motion, and those with an optimal ECG triggering method (P < .05 for all). Results of multivariate logistic analysis showed that changes in calcium volume, mean attenuation, and peak attenuation were significant predictors of interscan variability and caused the interscan variations of the coronary artery calcium measurements (r2 = 0.83, P < .0001). CONCLUSION: Coronary calcification at electron-beam CT varies from scan to scan. Volumetric scoring and optimal ECG triggering should be used to reduce interscan variability. Baseline calcium score and interscan variability must be considered in the evaluation of calcium progression.


Assuntos
Calcinose/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Eletrocardiografia , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Reprodutibilidade dos Testes
4.
J Comput Assist Tomogr ; 26(2): 202-9, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11884775

RESUMO

PURPOSE: This study identifies reasons for poor image quality and nonassessability of coronary artery segments and compares results between early and late diastolic triggering on coronary electron beam angiography (EBA). METHOD: One hundred patients referred for EBA were studied. Contrast-enhanced transaxial coronary images were acquired using electrocardiographic (ECG) triggering and reconstructed three dimensionally using volume-rendering techniques. The image quality of coronary segments and image artifacts were analyzed statistically. RESULTS: Volume rendering failed in seven patients (7%) owing to cardiac and breathing motions. Image quality was the best with the left main (LM) and worst with the left circumflex (LCX) coronary arteries (p < 0.001). The image quality decreased systematically from proximal to distal within each coronary artery (p < 0.001). Forty percent R-R interval triggering on ECG was better than 80% for image quality. The nonassessable segments occurred in 3% of LM, 2, 8, and 5% of proximal, 24, 22, and 12% of mid, and 64, 45, and 20% of distal segments of the left anterior descending, LCX, and right coronary arteries, respectively (p < 0.05). CONCLUSION: The major limitations of coronary EBA were suboptimal spatial resolution and image artifacts. The image quality could be improved by using optimal ECG triggering.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Imageamento Tridimensional/métodos , Idoso , Eletrocardiografia , Elétrons , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Controle de Qualidade , Software
SELEÇÃO DE REFERÊNCIAS