Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Pharm Bioallied Sci ; 16(Suppl 1): S651-S654, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38595414

RESUMO

Aim: This study aimed to evaluate the clinical efficacy of posterior resin implant-supported fixed partial dentures (FPDs) made from two different computer-aided design and computer-aided manufacturing (CAD-CAM) materials: polymethylmethacrylate (PMMA) and polyoxymethylene (POM). Materials and Methods: Twenty-one patients received a total of 49 interim implant-supported FPDs. The same participant received PMMA and POM as part of the control and experimental groups, respectively. The restorations were evaluated 1 week, 3 months, and 6 months after placement. In addition, their functional wear and color stability were assessed. Nonparametric statistics (α = 0.05) were used to analyze the data. Results: The study found that PMMA outperformed POM in surface and color parameters, with more fractures occurring with internal conical connection implants. The color stability analysis showed ΔE*ab values of 7.18 for PMMA and 8.8 for POM, with no significant differences. After 6 months of operation, both materials showed a significant increase in wear, but no significant differences were found within the materials. Conclusion: The study found that PMMA interim implant-supported FPDs outperformed POM in surface and color parameters, while polymer posterior implant-supported FPDs with internal conical connection implants were more fracture-prone.

2.
Bioinformation ; 17(1): 289-294, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34393448

RESUMO

To assess the role of prefabricated SFI-Bar in peri-implant bone loss around immediately axially loaded and straight implants. This study comprised of 40 complete denture wearer patients who received two axially parallel implants connected by SFI-Bars in group I and two 15° mesially tilted implants connected by SFI-Bars in group II. Peri- implant bone loss (PiBL) was measured at 1 year, 2 years and 3 years. The mean PiBL at 1 year in group I was 0.21 mm and I group II was 0.22, at 2 years in group I was 0.26 mm and in group II was 0.23 mm and at 3 years, in group I was 0.29 mm and in group II was 0.34 mm. The difference was significant at 3 years (P< 0.05). The mean mesial PIBL at 1 year in group I was 0.18 mm, in group II was 0.20 mm, at 2 years in group I was 0.19 mm and in group II was 0.07 mm and at 3 years, in group I was 0.25 mm and in group II was 0.29 mm. The difference found to be significant in each time duration in both groups (P< 0.05).The mean distal PIBL at 1 year in group I was 0.23 mm, in group II was 0.22 mm, at 2 years in group I was 0.33 mm and in group II was 0.39 mm and at 3 years, in group I was 0.34 mm and in group II was 0.39 mm. The difference found to be significant at 2 and 3 years in both groups (P< 0.05). Authors found that mandibular overdentures retained with Prefabricated SFI-Bar with axial and straight inserted implants may be useful in patients with reduced bone height.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...