Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Colloid Interface Sci ; 311(2): 323-37, 2007 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-17433350

RESUMO

Nonspherical particles, such as fractal-like aggregates emitted by diesel engines, are commonly met in the ambient air. Some of them are believed to be carcinogenic to humans, thus their efficient removal is of crucial practical importance. A fibrous filter is the device commonly used for aerosol purification but the literature lacks experimental data concerning aggregates filtration. Effect of aggregates' parameters (fractal dimension, primary particle radius) as well as fiber diameter and air velocity on the filtration efficiency is investigated theoretically using the modified Brownian dynamics method. Three different expressions for the friction coefficient evaluation for the aggregates were examined. The results obtained indicate that structure of an aggregate, filter structure and process conditions strongly influence the aggregates deposition efficiency, which significantly differs from the values determined for mass-equivalent spherical particles. The results determined using the Brownian dynamics approach were compared with the values calculated using classical single fiber theory and noticeable discrepancy was observed for the most penetrating particles, while both approaches agree for the limiting cases of small or large particles. Peclet number based on the mobility radius and the interception parameter based on the outer radius are the proper criteria to describe diffusional and deterministic deposition of aggregates.

2.
Am J Infect Control ; 34(2): 51-7, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16490606

RESUMO

BACKGROUND: Respiratory protection devices are used to protect the wearers from inhaling particles suspended in the air. Filtering face piece respirators are usually tested utilizing nonbiologic particles, whereas their use often aims at reducing exposure to biologic aerosols, including infectious agents such as viruses and bacteria. METHODS: The performance of 2 types of N95 half-mask, filtering face piece respirators and 2 types of surgical masks were determined. The collection efficiency of these respiratory protection devices was investigated using MS2 virus (a nonharmful simulant of several pathogens). The virions were detected in the particle size range of 10 to 80 nm. RESULTS: The results indicate that the penetration of virions through the National Institute for Occupational Safety and Health (NIOSH)-certified N95 respirators can exceed an expected level of 5%. As anticipated, the tested surgical masks showed a much higher particle penetration because they are known to be less efficient than the N95 respirators. The 2 surgical masks, which originated from the same manufacturer, showed tremendously different penetration levels of the MS2 virions: 20.5% and 84.5%, respectively, at an inhalation flow rate of 85 L/min. CONCLUSION: The N95 filtering face piece respirators may not provide the expected protection level against small virions. Some surgical masks may let a significant fraction of airborne viruses penetrate through their filters, providing very low protection against aerosolized infectious agents in the size range of 10 to 80 nm. It should be noted that the surgical masks are primarily designed to protect the environment from the wearer, whereas the respirators are supposed to protect the wearer from the environment.


Assuntos
Microbiologia do Ar , Poluentes Ocupacionais do Ar/isolamento & purificação , Exposição por Inalação/prevenção & controle , Máscaras/virologia , Dispositivos de Proteção Respiratória/virologia , Vírus/isolamento & purificação , Humanos , Controle de Infecções/métodos , Levivirus/isolamento & purificação , Máscaras/normas , Exposição Ocupacional/prevenção & controle , Dispositivos de Proteção Respiratória/normas
3.
Ann Occup Hyg ; 50(3): 259-69, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16344291

RESUMO

Protection of the human respiratory system from exposure to nanoparticles is becoming an emerging issue in occupational hygiene. The potential adverse health effects associated with particles of approximately 1-100 nm are probably greater than submicron or micron-sized particles. The performance of two models of N95 half-facepiece-filtering respirators against nano-sized particles was evaluated at two inhalation flow rates, 30 and 85 l min(-1), following a manikin-based protocol. The aerosol concentration was measured outside and inside the facepiece using the Wide-Range Particle Spectrometer. Sodium chloride particles, conventionally used to certify N-series respirators under NIOSH 42 CFR 84 regulations, were utilized as the challenge aerosol. The targeted particle sizes ranged from 10 to 600 nm, although the standard certification tests are performed with particles of approximately 300 nm, which is assumed to be the most penetrating size. The results indicate that the nanoparticle penetration through a face-sealed N95 respirator may be in excess of the 5% threshold, particularly at high respiratory flow rates. Thus, N95 respirators may not always provide the expected respiratory protection for workers. The highest penetration values representing the poorest respirator protection conditions were observed in the particle diameter range of approximately 30-70 nm. Based on the theoretical simulation, we have concluded that for respirators utilizing mechanical filters, the peak penetration indeed occurs at the particle diameter of approximately 300 nm; however, for pre-charged fiber filters, which are commonly used for N95 respirators, the peak shifts toward nano-sizes. This study has confirmed that the neutralization of particles is a crucial element in evaluating the efficiency of a respirator. The variability of the respirator's performance was determined for both models and both flow rates. The analysis revealed that the coefficient of variation of the penetration ranged from 0.10 to 0.54 for particles of 20-100 nm in diameter. The fraction of N95 respirators for which the performance test at 85 l min(-1) demonstrated excessive (>5%) penetration of nanoparticles was as high as 9/10. The test results obtained in a relatively small (0.096 m(3)) test chamber and in a large (24.3 m(3)) walk-in chamber were found essentially the same, thus, suggesting that laboratory-based evaluations have a good potential to adequately represent the respirator field performance.


Assuntos
Nanoestruturas , Exposição Ocupacional/prevenção & controle , Dispositivos de Proteção Respiratória/normas , Aerossóis , Poluentes Ocupacionais do Ar/química , Filtração , Humanos , Exposição por Inalação/prevenção & controle , Manequins , Teste de Materiais/métodos , Modelos Teóricos , Tamanho da Partícula , Cloreto de Sódio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA