Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Nanoscale ; 9(5): 1951-1955, 2017 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-28098304

RESUMO

The excitation of localized surface plasmons in noble metal nanoparticles (NPs) results in different nanoscale effects such as electric field enhancement, the generation of hot electrons and a temperature increase close to the NP surface. These effects are typically exploited in diverse fields such as surface-enhanced Raman scattering (SERS), NP catalysis and photothermal therapy (PTT). Halogenated nucleobases are applied as radiosensitizers in conventional radiation cancer therapy due to their high reactivity towards secondary electrons. Here, we use SERS to study the transformation of 8-bromoadenine (8BrA) into adenine on the surface of Au and AgNPs upon irradiation with a low-power continuous wave laser at 532, 633 and 785 nm, respectively. The dissociation of 8BrA is ascribed to a hot-electron transfer reaction and the underlying kinetics are carefully explored. The reaction proceeds within seconds or even milliseconds. Similar dissociation reactions might also occur with other electrophilic molecules, which must be considered in the interpretation of respective SERS spectra. Furthermore, we suggest that hot-electron transfer induced dissociation of radiosensitizers such as 8BrA can be applied in the future in PTT to enhance the damage of tumor tissue upon irradiation.


Assuntos
Adenina/análogos & derivados , DNA/química , Elétrons , Nanopartículas Metálicas , Adenina/química , Ouro , Lasers , Prata , Temperatura
2.
Nanoscale ; 8(19): 10339-47, 2016 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-27138897

RESUMO

The folding of single-stranded telomeric DNA into guanine (G) quadruplexes is a conformational change that plays a major role in sensing and drug targeting. The telomeric DNA can be placed on DNA origami nanostructures to make the folding process extremely selective for K(+) ions even in the presence of high Na(+) concentrations. Here, we demonstrate that the K(+)-selective G-quadruplex formation is reversible when using a cryptand to remove K(+) from the G-quadruplex. We present a full characterization of the reversible switching between single-stranded telomeric DNA and G-quadruplex structures using Förster resonance energy transfer (FRET) between the dyes fluorescein (FAM) and cyanine3 (Cy3). When attached to the DNA origami platform, the G-quadruplex switch can be incorporated into more complex photonic networks, which is demonstrated for a three-color and a four-color FRET cascade from FAM over Cy3 and Cy5 to IRDye700 with G-quadruplex-Cy3 acting as a switchable transmitter.


Assuntos
DNA/química , Corantes Fluorescentes , Quadruplex G , Telômero/química , Íons
3.
Nanoscale ; 8(10): 5612-20, 2016 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-26892770

RESUMO

DNA origami nanostructures are a versatile tool to arrange metal nanostructures and other chemical entities with nanometer precision. In this way gold nanoparticle dimers with defined distance can be constructed, which can be exploited as novel substrates for surface enhanced Raman scattering (SERS). We have optimized the size, composition and arrangement of Au/Ag nanoparticles to create intense SERS hot spots, with Raman enhancement up to 10(10), which is sufficient to detect single molecules by Raman scattering. This is demonstrated using single dye molecules (TAMRA and Cy3) placed into the center of the nanoparticle dimers. In conjunction with the DNA origami nanostructures novel SERS substrates are created, which can in the future be applied to the SERS analysis of more complex biomolecular targets, whose position and conformation within the SERS hot spot can be precisely controlled.


Assuntos
DNA/química , Ouro/química , Nanopartículas Metálicas/química , Nanotecnologia/métodos , Prata/química , Carbocianinas/química , DNA de Cadeia Simples/química , Dimerização , Microscopia de Força Atômica , Microscopia Eletrônica de Varredura , Hibridização de Ácido Nucleico , Rodaminas/química , Espalhamento de Radiação , Silício/química , Análise Espectral Raman
4.
Med Trop (Mars) ; 70(4): 349-52, 2010 Aug.
Artigo em Francês | MEDLINE | ID: mdl-22368931

RESUMO

Malaria and HIV/AIDS are two of the most widespread infectious diseases encountered in sub-Saharan Africa. Even minor interactions between these two diseases could have substantial effects on public health. The purpose of this study was to investigate associations between malaria and HIV infection. Study was carried out over an 8-month period (April 1, 2003 to November 30, 2003) in the Tropical and Infectious Diseases Department of the Donka National Hospital in Conakry, Guinea. A total of 89 malaria patients including 41 cases with HIV infection and 48 controls without HIV infection were included. All patients were hospitalized during the study and provided informed consent. Results showed that malaria affected all age groups in the same proportion. Mean patient age was 34 years (range, 15 and 76 years). Males were more frequently infected with a sex ratio of 1.05. The average number of malaria episodes was higher in cases (malaria with HIV-infection than in controls (malaria without HIV infection). Hyperthermia was observed in most cases (68.29%) and controls (77.08%). Severe anemia was observed in 26.82% of cases versus 10.41% of controls. Low parasite density was observed in 73.17% of cases as compared to 68.75% of controls. The recovery rate was higher in the control group than in case group: 27.08% versus 14.63%. The death rate was higher in the case group than in the control group: 21.95% versus 6.25%. These findings demonstrate a link between malaria and HIV. The frequency of malaria episodes was higher in patients with HIV infection than patients without HIV infection and the outcome of malarial episodes was better in patients without HIV infection.


Assuntos
Infecções por HIV/epidemiologia , Malária/epidemiologia , Adolescente , Adulto , Idoso , Anemia/epidemiologia , Estudos de Casos e Controles , Feminino , Febre/epidemiologia , Guiné/epidemiologia , Hospitais Públicos , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
5.
Clin Res Cardiol ; 96(9): 613-20, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17593312

RESUMO

UNLABELLED: Arrhythmia induction during implantation of cardioverter defibrillators (ICD) is a standard procedure. However, controversy exists regarding the need for routine arrhythmia induction before discharge from hospital (pre-hospital discharge (PHD) test). In order to reduce the number of tests we identified risk factors that predict relevant ICD malfunction. METHODS AND RESULTS: 965 patients receiving a first device implantation (n=724) or device/system replacement (n=241) between 1998 and 2004 were analysed. During implantation 176 (18%) complications (intraoperative undersensing of induced arrhythmias, unsuccessful arrhythmia-therapy or low DFT safety margin) occurred. Frequent (>4 times) intraoperative lead repositioning due to low sensing values was present in 44 patients (5%). 9% of the patients with first ICD implantation, 21% with device replacement and 27% with system replacement developed complications during PHD testing with arrhythmia induction. Intraoperative complications, although corrected during implantation, were independent risk factors for malfunction during PHD testing (p<0.05). Additional predictors for malfunction were intraoperative lead repositioning (>4 times) and a history of both VF and VT (p<0.05). Patients without intraoperative complications rarely developed malfunction during PHD testing (3.7% first device, 6.25% system replacement). Only in patients undergoing device replacement was a higher risk for failure (13%) evident. No risk factors could be identified for these subgroups. CONCLUSION: Routine arrhythmia induction during PHD is recommended in ICD patients with intraoperative complications, although corrected during implantation, as well as frequent intraoperatives lead repositioning. Patients undergoing device/system replacement uncomplicated implantation are not generally at low risk for device failure.


Assuntos
Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Desfibriladores Implantáveis , Falha de Equipamento , Análise de Falha de Equipamento , Segurança de Equipamentos , Feminino , Humanos , Complicações Intraoperatórias , Masculino , Pessoa de Meia-Idade , Alta do Paciente , Estudos Retrospectivos , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...