Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros











Intervalo de ano de publicação
1.
J. Oral Investig ; 8(2): 19-29, jul.-dez. 2019. graf, ilus
Artigo em Português | BBO - Odontologia | ID: biblio-1007244

RESUMO

Objetivo: Avaliar a eficácia da remoção de Ca (OH)2 do canal radicular, comparando o uso de limas manuais, Easy Clean e irrigação ultrassônica passiva (IUP). Método: Trinta dentes incisivos bovinos foram utilizados neste estudo. Os canais radiculares foram preparados e as amostras foram divididas aleatoriamente em 3 grupos de acordo com a técnica utilizada para a remoção do Ca(OH)2 (n = 10): G1: limas manuais; G2: lima Easy Clean; G3: IUP. Após quinze dias, os espécimes foram seccionados e processados para observação dos terços médio e apical utilizando microscopia eletrônica de varredura (MEV). Um avaliador cego e calibrado atribuiu escores a cada espécime. Os dados obtidos foram submetidos ao teste de Kruskal-Wallys, seguido do teste de Dunn. Resultados: Não houve diferença significativa na remoção do Ca(OH)2 entre a lima manual e a Easy Clean e entre Easy Clean e IUP. A técnica de IUP removeu significativamente mais Ca(OH)2 quando comparado com o grupo lima manual. Nenhuma das técnicas testadas removeu completamente o Ca(OH)2 das paredes do canal radicular. Conclusão: Independentemente da técnica utilizada, nenhum dos protocolos testados removeu completamente o Ca(OH)2 do canal radicular. Entretanto, a irrigação ultrassônica passiva foi mais eficaz do que o grupo das limas manuais(AU)


Objective: To evaluate the effectiveness of calcium hydroxide removal by comparing manual files, Easy Clean and passive ultrasonic irrigation (PUI) on Ca(OH)2 removal. Method: Thirty bovine incisors teeth wereused in this study. The root canals were prepared and the samples were randomly divided into 3 groups according to the technique used for Ca(OH)2 removal (n = 10): G1: manual files; G2: Easy Clean file; G3: Passive ultrasonic irrigation. After fifteen days, specimens were sectioned and processed for observation of the middle and apical thirds by using scanning electron microscopy (SEM). One blinded and calibrated evaluator attributed scores to each specimen. The data obtained from the SEM analysis were submitted to the Kruskal-Wallys test, followed by the Dunn test. Results: There was no significant difference in Ca(OH)2 removal between manual file and Easy Clean and between Easy Clean and PUI. PUI technique significantly removed more calcium hydroxide when compared with manual file group. None of the tested techniques completely removed the Ca(OH)2 from the root canal walls. Conclusion: Regardless of the technique used, none of the protocols tested completely removed the Ca(OH)2 from the root canal. However, passive ultrasonic irrigation was more effective than manual file group(AU)


Assuntos
Tratamento do Canal Radicular , Hidróxido de Cálcio , Microscopia Eletrônica de Varredura , Endodontia
2.
Microsc Res Tech ; 82(2): 128-133, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30582246

RESUMO

This study evaluated the influence of canal irrigation protocols with 5.25% calcium hypochlorite [Ca(OCl)2 ], 5.25% sodium hypochlorite (NaOCl) and 17% EDTA solution on the inorganic component of root canal dentin. Sixty roots were randomly divided into six groups (n = 10): Saline solution (SS) (control); Saline solution (SSE) +17% EDTA; CH - 5.25% Ca(OCl)2 ; CHE - 5.25% Ca(OCl)2 + 17% EDTA; SH - 5.25% NaOCl; SHE - 5.25% NaOCl +17% EDTA. After canal irrigation, the specimens were longitudinally split and analyzed by scanning electron microscopy (SEM). Dentinal tubules were observed in transverse (middle and apical thirds) direction. The images were classified in scores, according to smear layer removal and peritubular dentin alteration, and data were analyzed by Kruskal-Wallis's test, followed by Dunn's test (α = 0.05). In the middle third, all groups with EDTA presented better removal of the smear layer with higher peritubular dentin alteration (p < .05). In the apical third, this happened only in SHE (p < .05). Ca(OCl)2 and NaOCl exhibit similar performance to remove smear layer and alteration of the inorganic component in the middle third. In the apical third, NaOCl associated with EDTA showed better performance in smear layer removal.


Assuntos
Compostos de Cálcio/metabolismo , Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Ácido Edético/metabolismo , Irrigantes do Canal Radicular/metabolismo , Camada de Esfregaço/ultraestrutura , Hipoclorito de Sódio/metabolismo , Dente Pré-Molar/efeitos dos fármacos , Dente Pré-Molar/ultraestrutura , Cavidade Pulpar/ultraestrutura , Dentina/ultraestrutura , Humanos , Microscopia Eletrônica de Varredura
3.
Braz Dent J ; 28(5): 592-596, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29215684

RESUMO

The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).


Assuntos
Guta-Percha , Teste de Materiais
4.
Microsc Res Tech ; 80(12): 1337-1343, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28925588

RESUMO

The present study aimed to evaluate the effects of four endodontic chelating agents, followed by 2.5% sodium hypochlorite (NaOCl), as final irrigation regimens on organic and inorganic components of human root dentin. Sixty mandibular incisors were prepared and randomly divided into six groups (n = 10): QMiX, 1% peracetic acid (PA), 17% EDTA, 10% citric acid (CA), 2.5% NaOCl (solution control) and distilled water (DW-negative control). After irrigation with the chelating agents, a final flush was performed with 2.5% NaOCl. The specimens were split longitudinally in halves; one was designated for organic component analysis by polarized light microscopy (PLM) and the other for inorganic structure analysis by scanning electron microscopy (SEM). Scores data obtained in the PLM analysis were submitted to Kruskal-Wallis' test, followed by Dunn's test (p < .05). SEM findings were presented descriptively. NaOCl and DW groups showed uniformity in the fibrillar network and smear layer obliterating the dentinal tubules, while CA group presented alteration in organic and inorganic components of dentin. EDTA group did not show differences from others in the organic component, but altered the inorganic structure. QMiX and PA groups did not cause a significant morphological alteration in collagen and removed the smear layer without inorganic structure modification. As final irrigation, QMiX and PA solutions, followed by 2.5% NaOCl, showed better behavior than the other chelating agents tested, preserving organic and inorganic components of human root dentin.


Assuntos
Dentina/química , Dentina/ultraestrutura , Teste de Materiais/estatística & dados numéricos , Irrigantes do Canal Radicular/farmacologia , Quelantes , Colágeno/efeitos dos fármacos , Colágeno/ultraestrutura , Cavidade Pulpar/efeitos dos fármacos , Cavidade Pulpar/ultraestrutura , Dentina/efeitos dos fármacos , Humanos , Teste de Materiais/métodos , Microscopia Eletrônica de Varredura/métodos , Microscopia de Polarização/métodos , Preparo de Canal Radicular/métodos , Camada de Esfregaço/ultraestrutura , Hipoclorito de Sódio/farmacologia
5.
Braz. dent. j ; Braz. dent. j;28(5): 592-596, Sept.-Oct. 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-888696

RESUMO

Abstract The aim of this study was to evaluate the radiopacity of different gutta-percha points (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® and Odous®) in samples of 1 mm thick as established by ANSI/ADA Specification #57 and ISO 6876/2001, in comparison with thinner samples. Twelve test specimens for each material, four for each thickness (0.3, 0.6, and 1 mm and diameter of 8 mm), were laminated and compressed between two polished glass plates until the desirable thickness. Digital radiographs were obtained along with a graduated aluminum stepwedge varying from 1 to 10 mm in thickness. The X-ray unit was set at 70 kVp, 10 mA and 0.4 s exposure time, at a focal distance of 36 cm. One calibrated observer quantified the average values of pixels with Adobe Photoshop® software. Data were analyzed using ANOVA and Tukey tests, at 5% significance level. At 0.6 and 1 mm thickness, all the tested materials showed radiopacity higher than 3 mm of aluminum (reference value). At 0.3 mm thickness, Odous and Tanari presented significantly less radiopacity than the reference, and the other materials showed similar radiopacity to the reference. The study concluded that the materials demonstrated different radiopacities and all had values above the minimum recommended by ANSI/ADA specification #57, being Odous and Tanari less radiopaque than the reference value in thinner samples (0.3mm).


Resumo O objetivo deste estudo foi avaliar a radipacidade de diferentes pontas de guta-percha (Endo Points®, Dentsply®, Tanari®, Meta®, Roeko® e Odous®) em amostras de 1 mm de espessura, conforme estabelecido pela especificação #57 da ANSI/ADA e pela ISO 6876/2001, em comparação com amostras de menor espessura. Doze amostras de cada material, quatro para cada espessura (0,3, 0,6 e 1 mm; 8 mm de diâmetro), foram confeccionadas por meio de laminação e compressão entre duas lâminas de vidro polidas, até a espessura desejada. Radiografias digitais foram obtidas juntamente com uma escala de alumínio graduada, com espessuras variando de 1 a 10 mm. O aparelho de raios X foi ajustado para 70 kVp, 10 mA, 0,4s de tempo de exposição, com distância focal de 36 cm. Um observador calibrado quantificou a média dos valores de pixel no programa Adobe Photoshop®. Os dados foram analisados utilizando os testes ANOVA e Tukey, com nível de significância de 5%. Nas espessuras de 0,6 e 1 mm, todos os materiais testados apresentaram radiopacidade maior do que 3 mm de alumínio (valor de referência). Na espessura de 0,3 mm, Odous e Tanari apresentaram radiopacidade significativamente menor que a referência, e as outras marcas mostraram radiopacidade semelhante à referência. Conclui-se que os materiais apresentaram diferentes radiopacidades e todos mostraram valores acima do mínimo recomendado pela especificação #57 da ANSI/ADA, sendo Odous e Tanari menos radiopacos do que o valor de referência nas amostras mais finas (0.3 mm).


Assuntos
Guta-Percha , Teste de Materiais
6.
Braz Oral Res ; 31: e40, 2017 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-28513789

RESUMO

This study aimed to evaluate the effect of final irrigation protocols on microhardness reduction and erosion of root canal dentin. Sixty root canals from mandibular incisors were instrumented and randomly divided into six groups (n = 10) according to the irrigant used: QMiX, 17% EDTA, 10% citric acid (CA), 1% peracetic acid (PA), 2.5% NaOCl (solution control), and distilled water (negative control). The chelating solutions were used to irrigate the canal followed by 2.5% NaOCl as a final flush. After the irrigation protocols, all specimens were rinsed with 10 mL of distilled water to remove any residue of the chemical solutions. Before and after the final irrigation protocols, dentin microhardness was measured with a Knoop indenter. Three indentations were made at 100 µm and 500 µm from the root canal lumen. Afterwards, the specimens were prepared for scanning electron microscopic analysis and the amount of dentin erosion was examined. Wilcoxon and Kruskal-Wallis tests were used to analyze the results with a significance level set at 5%. At 100 µm, all protocols significantly reduced dentin microhardness (p < .05), while at 500 µm, this effect was detected only in the EDTA and QMiX groups (p < .05). CA was the irrigant that caused more extensive erosion in dentinal tubules, followed by PA and EDTA. QMiX opened dentinal tubules, but did not cause dentin erosion. Results suggest that QMiX and 17% EDTA reduced dentin microhardness at a greater depth. Additionally, QMiX did not cause dentin erosion.


Assuntos
Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Irrigantes do Canal Radicular , Erosão Dentária/induzido quimicamente , Biguanidas , Ácido Cítrico/farmacologia , Dentina/ultraestrutura , Ácido Edético/farmacologia , Testes de Dureza , Humanos , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácido Peracético/farmacologia , Polímeros , Distribuição Aleatória , Reprodutibilidade dos Testes , Tratamento do Canal Radicular/métodos , Camada de Esfregaço , Hipoclorito de Sódio/farmacologia , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos dos fármacos
7.
Braz. oral res. (Online) ; 31: e40, 2017. tab, graf
Artigo em Inglês | LILACS | ID: biblio-839529

RESUMO

Abstract This study aimed to evaluate the effect of final irrigation protocols on microhardness reduction and erosion of root canal dentin. Sixty root canals from mandibular incisors were instrumented and randomly divided into six groups (n = 10) according to the irrigant used: QMiX, 17% EDTA, 10% citric acid (CA), 1% peracetic acid (PA), 2.5% NaOCl (solution control), and distilled water (negative control). The chelating solutions were used to irrigate the canal followed by 2.5% NaOCl as a final flush. After the irrigation protocols, all specimens were rinsed with 10 mL of distilled water to remove any residue of the chemical solutions. Before and after the final irrigation protocols, dentin microhardness was measured with a Knoop indenter. Three indentations were made at 100 µm and 500 µm from the root canal lumen. Afterwards, the specimens were prepared for scanning electron microscopic analysis and the amount of dentin erosion was examined. Wilcoxon and Kruskal-Wallis tests were used to analyze the results with a significance level set at 5%. At 100 µm, all protocols significantly reduced dentin microhardness (p < .05), while at 500 µm, this effect was detected only in the EDTA and QMiX groups (p < .05). CA was the irrigant that caused more extensive erosion in dentinal tubules, followed by PA and EDTA. QMiX opened dentinal tubules, but did not cause dentin erosion. Results suggest that QMiX and 17% EDTA reduced dentin microhardness at a greater depth. Additionally, QMiX did not cause dentin erosion.


Assuntos
Humanos , Cavidade Pulpar/efeitos dos fármacos , Dentina/efeitos dos fármacos , Irrigantes do Canal Radicular , Erosão Dentária/induzido quimicamente , Biguanidas , Ácido Cítrico/farmacologia , Dentina/ultraestrutura , Ácido Edético/farmacologia , Testes de Dureza , Teste de Materiais , Microscopia Eletrônica de Varredura , Ácido Peracético/farmacologia , Polímeros , Distribuição Aleatória , Reprodutibilidade dos Testes , Tratamento do Canal Radicular/métodos , Camada de Esfregaço , Hipoclorito de Sódio/farmacologia , Estatísticas não Paramétricas , Propriedades de Superfície/efeitos dos fármacos
8.
Braz Dent J ; 27(6): 657-663, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27982175

RESUMO

Satisfactory biological behavior is a necessary requirement for clinical application of endodontic materials. In this study, the connective tissue responses to silicone (GuttaFlow 2), epoxy resin (AH Plus) and zinc oxide and eugenol (Endofill) based sealers were compared. Twelve Wistar rats had polyethylene tubes (four per animal) containing one of the tested sealers and empty tubes (negative control) implanted in their subcutaneous tissue. The tubes were randomly placed 2 cm from the spine and at least 2 cm apart from one another. Tissue samples with implants were processed for histological analysis after 7 or 60 days (n=6 animals per period). Inflammatory cells, fibrous condensation and abscess were scored according to their intensity. Friedman, followed by Dunn's post hoc, was used to compare sealers. Differences between the two experimental periods were verified using Mann-Witney U test (p<0.05). At 7 days, most of the histological parameters showed no significant differences amongst groups. Endofill group scored higher than the others for giant cells (o<0.05) and promoted a greater number of samples presenting abscess formation. GuttaFlow 2 tended to show a less intense inflammatory infiltrate compared to the other materials. At 60 days, there were no significant differences between groups in most of the histological parameters evaluated. However, it was observed that Endofill scored higher for macrophages (p<0.05) compared to the control group, and GuttaFlow 2 tended to present lower scores than the others for neutrophils and abscess. GuttaFlow 2 showed proper biological behavior and should be considered adequate for clinical practice.


Assuntos
Materiais Restauradores do Canal Radicular , Silicones , Animais , Masculino , Ratos , Ratos Wistar
9.
Braz. dent. j ; Braz. dent. j;27(6): 657-663, Nov.-Dec. 2016. tab, graf
Artigo em Inglês | LILACS | ID: biblio-828069

RESUMO

Abstract Satisfactory biological behavior is a necessary requirement for clinical application of endodontic materials. In this study, the connective tissue responses to silicone (GuttaFlow 2), epoxy resin (AH Plus) and zinc oxide and eugenol (Endofill) based sealers were compared. Twelve Wistar rats had polyethylene tubes (four per animal) containing one of the tested sealers and empty tubes (negative control) implanted in their subcutaneous tissue. The tubes were randomly placed 2 cm from the spine and at least 2 cm apart from one another. Tissue samples with implants were processed for histological analysis after 7 or 60 days (n=6 animals per period). Inflammatory cells, fibrous condensation and abscess were scored according to their intensity. Friedman, followed by Dunn's post hoc, was used to compare sealers. Differences between the two experimental periods were verified using Mann-Witney U test (p<0.05). At 7 days, most of the histological parameters showed no significant differences amongst groups. Endofill group scored higher than the others for giant cells (o<0.05) and promoted a greater number of samples presenting abscess formation. GuttaFlow 2 tended to show a less intense inflammatory infiltrate compared to the other materials. At 60 days, there were no significant differences between groups in most of the histological parameters evaluated. However, it was observed that Endofill scored higher for macrophages (p<0.05) compared to the control group, and GuttaFlow 2 tended to present lower scores than the others for neutrophils and abscess. GuttaFlow 2 showed proper biological behavior and should be considered adequate for clinical practice.


Resumo Um dos requisistos para a aplicação clínica de materiais endodônticos é apresentar comportamento biológico satisfatório. Neste estudo, as respostas do tecido conjuntivo a cimentos endodônticos à base de silicone (GuttaFlow 2), resina epóxica (AH Plus) e óxido de zinco e eugenol (Endofill) foram comparadas. Doze ratos Wistar tiveram tubos de polietileno (4 em cada animal) contendo um dos materiais e tubos vazios (controle negativo) implantados no tecido conjuntivo subcutâneo. Os tubos foram randomicamente posicionados pelo menos 2 cm distantes entre si e da espinha dorsal do animal. Amostras de tecido contendo os implantes foram processadas para análise histológica após 7 e 60 dias (n=6 animais por período). Células inflamatórias, condensação fibrosa e formação de abscesso foram classificadas em escores de acordo com sua intensidade. O teste Friedman, seguido por post hoc de Dunn, foi empregado para comparar os cimentos. O teste de Mann-Witney U foi empregado para verificar diferenças entre os períodos experimentais em cada grupo (p<0,05). Após 7 dias, a maior parte dos parâmetros histológicos não mostrou diferenças estatísticas entre os grupos. O cimento Endofill promoveu escores mais altos que os outros materiais para a variável células gigantes (p<0,05), além de apresentar um maior número de amostras com formação de abscesso. O GuttaFlow 2 tendeu a apresentar infiltrado inflamatório menos intenso comparado aos outros materiais. Após 60 dias, não houve diferenças estatisticamente significantes entre os grupos na maioria dos parâmetros avaliados. Entretanto, observou-se que o EndoFill apresentou escores mais altos para os macrófagos em comparação ao controle (p<0,05) e que o GuttaFlow 2 apresentou tendência a escores mais baixos que os demais materiais para as variáveis neutrófilos e abscesso. O GuttaFlow 2 apresentou propriedades biológicas apropriadas e pode ser considerado adequado para a prática clínica.


Assuntos
Animais , Masculino , Ratos , Materiais Restauradores do Canal Radicular , Silicones , Ratos Wistar
10.
Microsc Res Tech ; 75(11): 1557-63, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22865332

RESUMO

The aim of the present study was to characterize, by means of SEM, primary endodontic infections and to correlate with clinical and radiographic findings. Twelve (12) human extracted teeth (19 roots) presenting primary endodontic infection were examined. SEM qualitative observations of bacterial and defense cells, their features and distribution within the root canal lumen and root dentine were recorded for association with clinical and radiographic tabled data. Although a direct correlation between biofilm composition and clinical/radiographic findings was not established, structural organization and distribution of the biofilm, as well as the characteristics of host response, could be easily related to those features. Bacterial biofilm was predominant at the apical third. Symptomatic apical periodontitis was related to presence of bacterial biofilm all thirds. Defense cells could be seen in the apical third of some samples. These cells were present in all thirds in some of the cases with open cavities. The correlations performed in this study allowed a better understanding of the picture of primary endodontic infection, host response and relevant clinical features. The combined use of scanning electron microscopy with clinical and radiographic evaluation has the potential to overcome some limits of the current knowledge related to pulpal and periapical diseases, providing important insights for improving treatment strategies.


Assuntos
Pulpite/patologia , Fenômenos Fisiológicos Bacterianos , Biofilmes/crescimento & desenvolvimento , Humanos , Microscopia Eletrônica de Varredura , Pulpite/diagnóstico por imagem , Pulpite/imunologia , Pulpite/microbiologia , Radiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA