Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Anal Chim Acta ; 770: 153-60, 2013 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-23498698

RESUMO

A new method for uric acid (UA) determination based on the quenching of the cathodic ECL of the tris(2,2-bipyridine)ruthenium(II)-uricase system is described. The biosensor is based on a double-layer design containing first tris(2,2-bipyridine)ruthenium(II) (Ru(bpy)3(2+)) electrochemically immobilized on graphite screen-printed cells and uricase in chitosan as a second layer. The uric acid biosensing is based on the ECL quenching produced by uric acid over the cathodic ECL caused by immobilized Ru(bpy)3(2+) in the presence of uricase. The use of a -1.1 V pulse for 1s with a dwelling time of 10s makes it possible to estimate the initial enzymatic rate, which is used as the analytical signal. The Stern-Volmer type calibration function shows a dynamic range from 1.0×10(-5) to 1.0×10(-3)M with a limit of detection of 3.1×10(-6)M and an accuracy of 13.6% (1.0×10(-4)M, n=5) as relative standard deviation. Satisfactory results were obtained for urine samples, creating an affordable alternative for uric acid determination.


Assuntos
2,2'-Dipiridil/análogos & derivados , Técnicas Biossensoriais/instrumentação , Ácido Úrico/análise , 2,2'-Dipiridil/química , Complexos de Coordenação , Técnicas Eletroquímicas , Eletrodos , Humanos , Peróxido de Hidrogênio/química , Medições Luminescentes , Ácido Úrico/urina
2.
Anal Chim Acta ; 754: 91-8, 2012 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-23140959

RESUMO

An electrochemiluminescent cholesterol disposable biosensor has been prepared by the formation of assembled layers on gold screen-printed cells. The detection layer is based on the electro-formation of new luminol copolymers with different synthesized biotinylated pyrroles prepared by click-chemistry, offering a new transduction layer with new electroluminescent properties on biosensors. The electrochemiluminescence (ECL) luminol copolymers are electroformed by cyclic voltammetry (five cycles) at pH 7.0 uses a10(-3)M biotinylated pyrrole-luminol ratio of 1:10 in PBS buffer. With respect to the recognition layer, cholesterol oxidase was biotinylated by incubation with biotin vinyl sulfone, and immobilized on the copolymer by avidin-biotin interaction. The analytical signal of the biosensor is the ECL enzymatic initial rate working in chronoamperometric mode at 0.5V excitation potential with 10s between pulses at pH 9.5. The disposable device offers a cholesterol linear range from 1.5×10(-5)M to 8.0×10(-4)M with a limit of detection of 1.47×10(-5)M and accuracy of 7.9% for 9.0×10(-5)M and 14.1% for 2.0×10(-4)M, (n=5). Satisfactory results were obtained for cholesterol determination in serum samples compared to a reference procedure.


Assuntos
Técnicas Biossensoriais , Colesterol/sangue , Técnicas Eletroquímicas , Medições Luminescentes , Polímeros/química , Avidina/química , Biotina/química , Química Click , Humanos , Concentração de Íons de Hidrogênio , Luminol/química , Modelos Moleculares , Estrutura Molecular , Polímeros/síntese química , Pirróis/síntese química , Pirróis/química , Sensibilidade e Especificidade
3.
Talanta ; 86: 178-85, 2011 Oct 30.
Artigo em Inglês | MEDLINE | ID: mdl-22063528

RESUMO

A poly(luminol-3,3',5,5'-tetramethylbenzidine) copolymer manufactured by electropolymerization on screen-printed gold electrodes greatly improves the electrochemiluminescence of hydrogen peroxide. Cholesterol oxidase was immobilized on the surface of a poly(luminol-3,3',5,5'-tetramethylbenzidine) screen-printed cell modified with chitosan to prepare an ECL biosensor for cholesterol. Working under the optimized conditions, the linear dynamic range of cholesterol was 2.4 × 10(-5)-1.0 × 10(-3)M with a limit of detection of 7.3 × 10(-6)M and a precision of 10.3% (5.0 × 10(-4)M, n=5) expressed as relative standard deviation. This biosensor was applied to the determination of total cholesterol in serum samples obtaining satisfactory results with respect to the reference procedure. This cholesterol biosensor offers an alternative analytical method with low cost and high speed.


Assuntos
Técnicas Biossensoriais/métodos , Colesterol/sangue , Técnicas Eletroquímicas/métodos , Medições Luminescentes/métodos , Luminol/química , Polímeros/química , Benzidinas/química , Humanos
4.
Anal Chim Acta ; 702(2): 254-61, 2011 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-21839206

RESUMO

A new electrochemiluminescent (ECL) disposable biosensor for uric acid was manufactured by immobilization in a double-layer design of luminol as a copolymer with 3,3',5,5'-tetramethylbenzidine (TMB) and the enzyme uricase in chitosan on gold screen-printed cells. The good mechanical and improved electroluminescent characteristics of the new copolymer poly(luminol-TMB) make it possible to determine uric acid by measuring the growing ECL emission with the analyte concentration. The combination of enzymatic selectivity with ECL sensitivity results in a disposable analytical device with a linear range for uric acid from 1.5×10(-6) to 1.0×10(-4) M, a limit of detection of 4.4×10(-7) M and a precision of 13.1% (1.0×10(-5) M, n=10) as relative standard deviation. Satisfactory results were obtained for uric acid determination in 24h-urine samples compared to a reference procedure. This uric acid biosensor can be used as a low-cost alternative to conventional methods.


Assuntos
Benzidinas/química , Técnicas Biossensoriais/métodos , Equipamentos Descartáveis , Medições Luminescentes/métodos , Luminol/química , Ácido Úrico/urina , Técnicas Biossensoriais/economia , Técnicas Biossensoriais/instrumentação , Quitosana/química , Eletrodos , Ouro/química , Humanos , Sensibilidade e Especificidade , Fatores de Tempo , Urato Oxidase/química , Urato Oxidase/metabolismo
5.
Anal Bioanal Chem ; 400(9): 3041-51, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21484245

RESUMO

An efficient electrochemiluminescent (ECL) single-use sensor for H(2)O(2) is presented based on an electropolymerized film prepared on screen-printed gold electrode (gold SPE). A study of the copolymerization of luminol in the presence of different monomers was carried out. The polymeric films were grown potentiodynamically with a potential interval between -0.2 and 1.0 V in 0.2 M H(2)SO(4) and were characterized by their electrochemical, electrochemiluminescent, and superficial features. The polymer with the most efficient growth and ECL emission was poly(luminol-3,3',5,5'-tetramethylbenzidine) at 1:5 ratio. These prepared SPE cells present good mechanical and photoemissive properties. A semi-logarithmic linearization shows a noticeable four decade-width concentration range with a limit of detection (LOD) of 2.6 × 10(-9) M and a precision of 10.2% (n = 5; as relative standard deviation, RSD) in the medium range level. The described SPE ECL sensors will be useful for the determination of oxidase substrates in ECL single-use biosensors.

6.
Luminescence ; 26(1): 44-53, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-20013758

RESUMO

This paper presents a new application for monolithic columns with low-pressure chromatographic separation using an flow injection analysis configuration with chemiluminescent detection for the determination of a mixture of phenolic compounds: phloroglucinol, 2,4-dihydroxybenzoic acid, salicylic acid, methyl paraben and n-propyl gallate. The procedure consists of the separation of these compounds on a reverse-phase ultra-short monolithic column with pH 3.0 acetate buffer and 5% acetonitrile as carrier phase. The detection is based on a chemiluminescence measurement coming from Ce(IV)-Rhodamine 6G chemistry with the incorporation of two different chemiluminescent chemical conditions in the chromatographic setup in order to enhance the sensitivity for the different phenolic compounds. All separation and detection variables were optimized to propose a determination method. The analysis is performed in 280?s, with the sampling frequency being some 13 h(-1) . The calibration function is a double reciprocal function obtaining good results within two orders of magnitude. The limits of detection were 8.8 × 10 (-8) m (phloroglucinol), 2.7 × 10 (-8) m (2,4-dihydroxybenzoic acid); 2.3 × 10 (-8) m (salicylic acid); 5.2 × 10 (-8) m (methyl paraben) and 4.1 × 10 (-6) m (n-propyl gallate), and the relative standard deviations at a medium level of the linear range were 4.4% (phloroglucinol), 2.8% (2,4-dihydroxybenzoic acid), 5.2% (salicylic acid), 3.6% (methyl paraben) and 6.8% (n-propyl gallate). The method was applied and validated satisfactorily for the determination of these compounds in healthcare products, comparing the results against an HPLC reference method.


Assuntos
Medições Luminescentes , Fenóis/análise , Cromatografia Líquida/métodos , Estrutura Molecular , Fenóis/química
7.
Analyst ; 134(7): 1423-32, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19562211

RESUMO

An electrochemiluminescence-based disposable biosensor for lactate is characterized. The lactate recognition system is based on lactate oxidase (LOx) and the transduction system consists of luminol. All the needed reagents, luminol, LOx, BSA, electrolyte and buffer have been immobilized by a Methocel membrane placed on the working electrode of the screen-printed electrochemical cell. The measurement of the electrochemiluminescence (ECL) is made possible via a photocounting head when 50 microl of sample is placed into the screen-printed cell with a circular container containing the disposable sensing membrane. The compositions of the membrane and reaction conditions have been optimized to obtain adequate sensitivity. The disposable biosensor responds to lactate after 20 s when two 1 s pulses at 0.5 V are applied to obtain the analytical parameter, the ECL initial rate. The linearized double logarithmic dependence for lactate shows a dynamic range from 10(-5) to 5 x 10(-4) M with a detection limit of 5 x 10(-6) M and a sensor-to-sensor repeatability, as relative standard deviation, RSD, of 3.30% at the medium level of the range. The ECL disposable biosensor was applied to the analysis of lactate in human saliva as an alternative procedure for obtaining the lactate level in a non-invasive way. Interferences coming from components of saliva were studied and eliminated in a simple way that was easy to handle. The procedure was validated for use in human saliva, comparing the results against an enzymatic reference procedure. The proposed method is quick, inexpensive, selective and sensitive and uses conventional ECL instrumentation.


Assuntos
Técnicas Biossensoriais/métodos , Equipamentos Descartáveis , Lactatos/análise , Saliva/química , Animais , Técnicas Biossensoriais/instrumentação , Soluções Tampão , Bovinos , Eletroquímica , Eletrodos , Eletrólitos/química , Grafite/química , Humanos , Peróxido de Hidrogênio/metabolismo , Concentração de Íons de Hidrogênio , Indicadores e Reagentes/química , Lactatos/metabolismo , Medições Luminescentes , Luminol/química , Membranas Artificiais , Metanol/química , Oxigenases de Função Mista/metabolismo , Oxirredução , Soroalbumina Bovina/química , Temperatura
8.
Talanta ; 79(2): 499-506, 2009 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-19559911

RESUMO

This paper presents an application of chromatographic separation based on an ultra-short monolithic column and chemiluminescent detection in an FIA type instrument manifold for the determination of four paraben mixtures: methylparaben (MP), ethylparaben (EP), propylparaben (PP) and butylparaben (BP). The separation is achieved in 150 s using two consecutive carriers: first 12% ACN:water that changes 75 s after injection to 27% ACN:water. The detection is based on the oxidation of the hydrolysis product of parabens, p-hydroxybenzoic acid, with Ce(IV) in the presence of Rhodamine 6G which evokes chemiluminescence of sufficient intensity to enable a sensitive determination of these species. After optimization of the variables involved, the analytical method is characterized, displaying the following values for concentration ranges, detection limits and precision, as relative standard deviation at low concentration (0.15 mg l(-1))-MP: from 9.9x10(-7) to 3.3x10(-4)M; 1.9x10(-8); 5.6%; EP: from 9.0x10(-7) to 3.3x10(-4)M; 2.8x10(-8); 3.5%; PP: from 8.3x10(-7) to 9.9x10(-5)M; 2.3x10(-8); 4.2%; and BP: from 7.7x10(-7) to 9.9x10(-5)M; 4.2x10(-8)M; 6.2%. The method was applied and validated satisfactorily for the determination of these parabens in cosmetic samples, comparing the results against a liquid chromatography reference method.


Assuntos
Cosméticos/análise , Parabenos/análise , Cromatografia Líquida/instrumentação , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Medições Luminescentes/métodos , Medições Luminescentes/normas , Reprodutibilidade dos Testes
9.
Anal Chim Acta ; 629(1-2): 136-44, 2008 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-18940330

RESUMO

A new chemiluminescence-based one-shot biosensor for lactate is described. The lactate recognition system is based on lactate oxidase (LOx) and the transduction system consists of luminol, peroxidase from Arthromyces ramosus (ARP) and metallic aluminum, all immobilized in a polyion complex membrane. The measurement of the chemiluminescence in a luminometer when 1 mL of sample is injected into a conventional cell containing the disposable sensing membrane makes it possible to determine lactate. The compositions of the membrane and reaction conditions have been optimized to obtain adequate sensitivity. The one-shot biosensor responds to lactate rapidly, with the typical CL acquisition time being 2 min, with a linearized logarithmic dependence whose dynamic range was from 5 x 10(-5) to 4 x 10(-3) with a detection limit of 9.2 x 10(-6)M and a sensor-to-sensor reproducibility (relative standard deviation, R.S.D.) of 5.5% at the medium level of the range. The performance of the chemiluminescent one-shot biosensor was tested for the analysis of lactate in yoghurt, validating the results against an enzymatic reference procedure. The proposed method is quick, inexpensive and sensitive and uses conventional CL instrumentation.


Assuntos
Técnicas Biossensoriais/métodos , Ácido Láctico/metabolismo , Luminescência , Agaricales/enzimologia , Peróxido de Hidrogênio/metabolismo , Indicadores e Reagentes/química , Luminol/metabolismo , Membranas Artificiais , Oxigenases de Função Mista/metabolismo , Iogurte/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...