Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1673: 463119, 2022 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-35550980

RESUMO

Solving and/or evaluating given problems or decision making in place and in real time is a goal of the analytical chemistry science. In this context, the performance of a commercial portable miniaturized liquid chromatograph (minLC) with LED UV (255 nm) detector was compared with those provided by two lab minLCs (capillary and nano) coupled on-line to in-valve in-tube solid phase microextraction (IT-SPME) with diode array detector (DAD). In addition, responses of the portable LC for in-field analysis in several conditions were tested. Besides, two evaluation tools, BETTER criteria for portability and HEXAGON pictogram for sustainability and greenness were applied for comparison purposes. The benchtop LCs provided lower limits of detection (LODs) as expected, in the order of low µg L-1, than those achieved by the portable LC, with LODs around mg L-1 for compounds covering several polarities (logKow between -1.72 and 3.82). The used portable LC gave excellent resolution, reducing the analysis time and being the consumption of solvents negligible. As a practical application, fruit washing residual waters, which contained a suitable level of concentrations of several biocides for employing the portable minLC, were analyzed and quantified from the three minLCs as a proof of concept with comparable results.


Assuntos
Desinfetantes , Águas Residuárias , Cromatografia Líquida de Alta Pressão , Cromatografia Líquida/métodos , Limite de Detecção , Microextração em Fase Sólida/métodos
2.
Talanta ; 223(Pt 2): 121778, 2021 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-33298283

RESUMO

A composite membrane containing 1,2-naphthoquinone-4-sulfonic acid sodium salt (NQS) embedded in an ionic liquid (IL)- polydimethylsiloxane (PDMS)- tetraethyl orthosilicate (TEOS)- SiO2 nanoparticles (NPs) polymeric matrix is proposed. The selected IL was 1-methyl-3-octylimidazolium hexafluorophosphate (OMIM PF6). It is demonstrated that ILs chemical additives of PDMS influenced the sol-gel porosity. The sensor analytical performance for ammonia atmospheres has been tested as a function of sampling time (between 0.5 and 312 h), temperature (25 °C and 4 °C) and sampling volume (between 2L and 22 mL) by means of diffuse reflectance measurements and sensor photos, which can be registered and saved as images by a smartphone, which permit RGB measurements too. Flexible calibration was possible, adapting it to the sampling time, temperature and sampling volume needed for its application. Calibration linear slopes (mA vs ppmv) between 1.7 and 467 ppmv-1 were obtained for ammonia in function of the several studied conditions. Those slopes were between 48 and 91% higher than those achieved with sensors without ILs. The practical application of this sensing device was demonstrated for the analysis of meat packaging environments, being a potential cost-effective candidate for in situ meat freshness analysis. NQS provided selectivity in reference to other family compounds emitted from meat products, such as sulphides. After 10 days at 4 °C ammonia liberated by the assayed meat was 20 ± 4 µg/kg and 18 ± 3 µg/kg, quantified by using diffuse reflectance and %R measurements, respectively. Homogeneity of the ammonia atmosphere was tested by using two sensors placed in two different positions inside the packages.


Assuntos
Colorimetria , Líquidos Iônicos , Carne/análise , Polímeros , Dióxido de Silício
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...