Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian J Cancer ; 51(2): 145-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25104197

RESUMO

AIM: The purpose of the survey was to understand the role of positron emission tomography (PET) in clinical radiotherapy practice among the radiation oncologists' in India. SETTINGS AND DESIGN: An online questionnaire was developed to survey the oncologists on their use of PET, viewing protocols, contouring techniques practiced, the barriers on the use of PET and the need for training in use of PET in radiotherapy. The questionnaire was sent to about 500 oncologists and 76 completed responses were received. RESULTS: The survey shows that radiation oncologists use PET largely to assess treatment response and staging but limitedly use it for radiotherapy treatment planning. Only manual contouring and fixed threshold based delineation techniques (e.g. 40% maximum standard uptake value [SUV max ] or SUV 2.5) are used. Cost is the major barrier in the wider use of PET, followed by limited availability of FDG radionuclide tracer. Limited or no training was available for the use of PET. CONCLUSIONS: Our survey revealed the vast difference between literature suggestions and actual clinical practice on the use of PET in radiotherapy. Additional training and standardization of protocols for use of PET in radiotherapy is essential for fully utilizing the capability of PET.


Assuntos
Tomografia por Emissão de Pósitrons/estatística & dados numéricos , Padrões de Prática Médica/estatística & dados numéricos , Radioterapia (Especialidade)/métodos , Humanos , Índia , Imagem Multimodal , Radioterapia (Especialidade)/educação , Planejamento da Radioterapia Assistida por Computador , Inquéritos e Questionários , Tomografia Computadorizada por Raios X
2.
Australas Phys Eng Sci Med ; 34(4): 441-7, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21830106

RESUMO

In areas like adaptive therapy, multi-phase radiotherapy, and single fraction palliative treatment or in the treatment of patients with metal implants where megavoltage(MV) CT could be considered as a treatment planning modality, the reduced contrast in the MV CT images could lead to limited accuracy in localization of the structures. This would affect the precision of the treatment. In this study, as an extension our previous work on bespoke MV cone beam CT (MV CBCT), we propose to register the MV CBCT with kilovoltage (kV) CT for treatment planning. The MV CBCT images registered with kV CT would be effective for treatment planning as it would account for the inadequate soft tissue information in the MV CBCT and would allow comparison of changes in patient dimensions and assist in localization of the structures. The intensity based registration algorithm of the BrainSCAN therapy planning software was used for image registration of the MV CBCT and kV CT images. The accuracy of the registration was validated using qualitative and quantitative measures. The effect of image quality on the level of agreement between the contouring done on both the MV CBCT and kV CT was assessed by comparing the volumes of six structures delineated. To assess the level of agreement between the plans after the registration, two independent plans were generated on the MV CBCT and the planning CT using the posterior fossa of the skull as the target. The dose volume histograms and conformity indices of the plans were compared. The results of this study show that treatment planning with MV CBCT images would be effective, using additional anatomical structure information derived from registering the MV CBCT image with a standard kVCT.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Processamento de Imagem Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/normas , Humanos , Planejamento da Radioterapia Assistida por Computador/normas , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...