Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Doc Ophthalmol ; 149(1): 23-45, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38955958

RESUMO

PURPOSE: Multiple sclerosis (MS) is a neuro-inflammatory disease affecting the central nervous system (CNS), where the immune system targets and damages the protective myelin sheath surrounding nerve fibers, inhibiting axonal signal transmission. Demyelinating optic neuritis (ON), a common MS symptom, involves optic nerve damage. We've developed NeuroVEP, a portable, wireless diagnostic system that delivers visual stimuli through a smartphone in a headset and measures evoked potentials at the visual cortex from the scalp using custom electroencephalography electrodes. METHODS: Subject vision is evaluated using a short 2.5-min full-field visual evoked potentials (ffVEP) test, followed by a 12.5-min multifocal VEP (mfVEP) test. The ffVEP evaluates the integrity of the visual pathway by analyzing the P100 component from each eye, while the mfVEP evaluates 36 individual regions of the visual field for abnormalities. Extensive signal processing, feature extraction methods, and machine learning algorithms were explored for analyzing the mfVEPs. Key metrics from patients' ffVEP results were statistically evaluated against data collected from a group of subjects with normal vision. Custom visual stimuli with simulated defects were used to validate the mfVEP results which yielded 91% accuracy of classification. RESULTS: 20 subjects, 10 controls and 10 with MS and/or ON were tested with the NeuroVEP device and a standard-of-care (SOC) VEP testing device which delivers only ffVEP stimuli. In 91% of the cases, the ffVEP results agreed between NeuroVEP and SOC device. Where available, the NeuroVEP mfVEP results were in good agreement with Humphrey Automated Perimetry visual field analysis. The lesion locations deduced from the mfVEP data were consistent with Magnetic Resonance Imaging and Optical Coherence Tomography findings. CONCLUSION: This pilot study indicates that NeuroVEP has the potential to be a reliable, portable, and objective diagnostic device for electrophysiology and visual field analysis for neuro-visual disorders.


Assuntos
Potenciais Evocados Visuais , Esclerose Múltipla , Neurite Óptica , Humanos , Potenciais Evocados Visuais/fisiologia , Neurite Óptica/diagnóstico , Neurite Óptica/fisiopatologia , Esclerose Múltipla/diagnóstico , Esclerose Múltipla/fisiopatologia , Feminino , Masculino , Adulto , Campos Visuais/fisiologia , Córtex Visual/fisiopatologia , Eletroencefalografia/instrumentação , Pessoa de Meia-Idade , Projetos Piloto , Estimulação Luminosa
2.
medRxiv ; 2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38234795

RESUMO

Purpose: Multiple Sclerosis (MS) is a neuro-inflammatory disease of the Central Nervous System (CNS) in which the body's immune system attacks and destroys myelin sheath that protects nerve fibers and causes disruption in axonal signal transmission. Demyelinating Optic Neuritis (ON) is often a manifestation of MS and involves inflammation of the optic nerve. ON can cause vision loss, pain and discomfort in the eyes, and difficulties in color perception.In this study, we developed NeuroVEP, a portable, wireless diagnostic system that delivers visual stimuli through a smartphone in a headset and measures evoked potentials at the visual cortex from near the O1, Oz, O2, O9 and O10 locations on the scalp (extended 10-20 system) using custom electroencephalography (EEG) electrodes. Methods: Each test session is constituted by a short 2.5-minute full-field visual evoked potentials (ffVEP) test, followed by a 12.5-minute multifocal VEP (mfVEP) test. The ffVEP test evaluates the integrity of the visual pathway by analyzing the P1 (also known as P100) component of responses from each eye, while the mfVEP test evaluates 36 individual regions of the visual field for abnormalities. Extensive signal processing, feature extraction methods, and machine learning algorithms were explored for analyzing the mfVEP responses. The results of the ffVEP test for patients were evaluated against normative data collected from a group of subjects with normal vision. Custom visual stimuli with simulated defects were used to validate the mfVEP results which yielded 91% accuracy of classification. Results: 20 subjects, 10 controls and 10 with MS and/or ON were tested with the NeuroVEP device and a standard-of-care (SOC) VEP testing device which delivers only ffVEP stimuli. In 91% of the cases, the ffVEP results agreed between NeuroVEP and SOC device. Where available, the NeuroVEP mfVEP results were in good agreement with Humphrey Automated Perimetry visual field analysis. The lesion locations deduced from the mfVEP data were consistent with Magnetic Resonance Imaging (MRI) and Optical Coherence Tomography (OCT) findings. Conclusion: This pilot study indicates that NeuroVEP has the potential to be a reliable, portable, and objective diagnostic device for electrophysiology and visual field analysis for neuro-visual disorders.

3.
Eye Brain ; 13: 111-127, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33953628

RESUMO

BACKGROUND: Delayed Dark-Adapted vision Recovery (DAR) is a biomarker for Age-related Macular Degeneration (AMD), however its measurement is burdensome for patients and examiners. METHODS: In this study, we developed a portable, wireless and user-friendly system that employs a headset with a smartphone to deliver controlled photo-bleach and monocular pattern reversal stimuli, while using custom electroencephalography (EEG) electrodes and electronics in order to measure Dark-Adapted Visual Evoked Potentials (DAVEP) objectively and separately at the peripheral and central visual field. This is achieved in one comfortable 20-minute session, without requiring subject reporting. DAVEP responses post photo-bleach for up to 15 minutes were measured concurrently from both eyes in 12 AMD-patients, 1 degenerative myopia patient, and 8 controls who had no diagnosed macular vision loss. RESULTS: Robust positive polarity DAVEP responses were observed at 200-500 ms from stimulus onset to scotopic stimuli that have been seldom reported and analyzed previously. The amplitude recovery of the DAVEP response was significantly delayed in AMD patients as compared to controls. We developed DAVEP1 scores, a simple metric for DAR, which classified 90% of subject eyes correctly, indicating the presence of AMD in at least one eye of all pre-confirmed subjects with this diagnosis. CONCLUSION: We developed a user-friendly, portable VEP system and DAVEP1 metric, which show a high potential to identify DAR-deficits in AMD-patients. This novel technology could aid in early diagnosis of AMD.

4.
J Biomech Eng ; 137(1)2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25392856

RESUMO

In this study, the changes in the bone density of human femur model as a result of different loadings were investigated. The model initially consisted of a solid shell representing cortical bone encompassing a cubical network of interconnected rods representing trabecular bone. A computationally efficient program was developed that iteratively changed the structure of trabecular bone by keeping the local stress in the structure within a defined stress range. The stress was controlled by either enhancing existing beam elements or removing beams from the initial trabecular frame structure. Analyses were performed for two cases of homogenous isotropic and transversely isotropic beams.Trabecular bone structure was obtained for three load cases: walking, stair climbing and stumbling without falling. The results indicate that trabecular bone tissue material properties do not have a significant effect on the converged structure of trabecular bone. In addition, as the magnitude of the loads increase, the internal structure becomes denser in critical zones. Loading associated with the stumbling results in the highest density;whereas walking, considered as a routine daily activity, results in the least internal density in different regions. Furthermore, bone volume fraction at the critical regions of the converged structure is in good agreement with previously measured data obtained from combinations of dual X-ray absorptiometry (DXA) and computed tomography (CT). The results indicate that the converged bone architecture consisting of rods and plates are consistent with the natural bone morphology of the femur. The proposed model shows a promising means to understand the effects of different individual loading patterns on the bone density.


Assuntos
Remodelação Óssea , Fêmur/fisiologia , Análise de Elementos Finitos , Humanos , Estresse Mecânico , Caminhada/fisiologia , Suporte de Carga
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...