Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Eur J Prosthodont Restor Dent ; 31(2): 109-115, 2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-35917152

RESUMO

This in-situ study aimed to evaluate the chromatic stability, microhardness, and surfacefree energy of chemically activated acrylic resin (CAAR) samples. Eighty CAAR samples were made and each volunteer (n = 20) received two palatal plates with two sides of groups (without and with glaze application). The samples were exposed to two conditions: the control condition (sucrose 30%) and the test condition (sucrose 30% and 0.12% chlorhexidine). The volunteers used the first palatal device (control condition) for seven days and the second palatal device (test condition) for another seven days, with a seven-day break between them. Then, the ΔΕ00, microhardness, and surface-free energy tests were performed. Analysis of Variance and the Tukey test were used (α = 0.05). The control group with glaze showed higher ΔΕ00 compared to the group without the glaze. The test group with glaze had less ΔΕ00 than their respective controls. In both periods, when the glaze was applied, higher microhardness values were found for all groups. Groups with glaze showed lower roughness and higher surface-free energy than groups without the glaze. The values obtained in this study were satisfactory, showing the clinical efficacy of glaze and the use of 0.12% CH for maintaining the physical and mechanical properties of CAAR.


Assuntos
Resinas Acrílicas , Clorexidina , Humanos , Resinas Acrílicas/química , Cura Luminosa de Adesivos Dentários , Lâmpadas de Polimerização Dentária , Propriedades de Superfície , Teste de Materiais , Dureza
2.
J Biomech ; 46(7): 1312-20, 2013 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-23518207

RESUMO

A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (σvM), maximum (σmax) and minimum (σmin) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (σvM=398.8, σmax=580.5 and σmin=-455.2) while FD group showed the lowest one (σvM=128.9, σmax=185.9 and σmin=-172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for σvM, 66.2% for σmax and 57.7% for σmin versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for σmax, and 15.7% and 85.7% for σmin on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components.


Assuntos
Implantes Dentários , Planejamento de Prótese Dentária , Revestimento de Dentadura , Mandíbula/diagnóstico por imagem , Mandíbula/fisiopatologia , Estresse Mecânico , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia
3.
J Oral Rehabil ; 35(10): 766-74, 2008 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-18482352

RESUMO

The aim of this study was to compare the stress distribution induced by posterior functional loads on conventional complete dentures and implant-retained overdentures with different attachment systems using a two-dimentional Finite Element Analysis (FEA-2D). Three models representative of edentulous mandible were constructed on AutoCAD software; Group A (control), a model of edentulous mandible supporting a complete denture; Group B, a model of edentulous mandible supporting an overdenture over two splinted implants connected with the bar-clip system; Group C, a model of edentulous mandible supporting an overdenture over two unsplinted implants with the O-ring system. Evaluation was conducted on Ansys software, with a vertical force of 100 N applied on the mandibular left first molar. When the stress was evaluated in supporting tissues, groups B (51.0 MPa) and C (52.6 MPa) demonstrated higher stress values than group A (10.1 MPa). Within the limits of this study, it may be concluded that the use of an attachment system increased stress values; furthermore, the use of splinted implants associated with the bar-clip attachment system favoured a lower stress distribution over the supporting tissue than the unsplinted implants with an O-ring abutment to retain the mandibular overdenture.


Assuntos
Prótese Dentária Fixada por Implante , Prótese Total , Revestimento de Dentadura , Análise do Estresse Dentário/métodos , Planejamento de Dentadura , Retenção de Dentadura/métodos , Humanos , Teste de Materiais/métodos , Modelos Anatômicos , Estresse Mecânico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...