Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Indian Pacing Electrophysiol J ; 24(3): 133-139, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38548225

RESUMO

BACKGROUND: Conduction disturbances remain one of the most common complications occurring post TAVI. We aim to determine the predictors of cardiac conduction disturbances after Transcatheter Aortic Valve Implantation (TAVI) and propose a relevant predictive model. We included 70 consecutive patients with severe symptomatic AS who underwent TAVI using the self-expanding valve Evolut R or the balloon expandable Sapien XT valve. All patients were subjected to electrocardiographic evaluation pre- and post-TAVI and at 30 days. Clinical, echocardiographic, CT-derived, and procedural parameters were collected and analyzed. RESULTS: Conduction disturbances affected 28 patients (40%): 16 patients (22.9 %) developed Left Bundle Branch Block (LBBB), 7 patients (10%) experienced transient Complete Heart Block (CHB), and 5 patients (7.1%) experienced permanent CHB requiring Permanent Pacemaker Implantation (PPI). We classified predictors into preprocedural and procedural predictors. Multivariate logistic regression analysis of pre-procedural predictors showed that the presence of basal septal calcification is the most powerful independent predictor (OR: 28.63, 95% CI: 4.59-178.68, p < 0.001). Multivariate logistic regression analysis for pre and post procedural predictors showed that the relationship between depth of implantation at the septum and membranous septum expressed in percentage (sDIMS) with cut-off >70.42% is the most powerful independent procedural predictor (OR: 1.11, 95% CI: 1.03-1.2, p 0.006). CONCLUSION: Conduction disturbances remain a common complication of TAVI. Presence of basal septal calcification is a non-modifiable risk factor that increase patient propensity of development such complication after TAVI. A depth of implantation exceeding 70% of the membranous septal length has been found to strongly predict conduction disturbances post TAVI. sDIMS can be used in planning the depth of implantation to reduce incidence of conduction disturbances post TAVI.

2.
Egypt Heart J ; 76(1): 20, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345661

RESUMO

BACKGROUND: Transcatheter Aortic Valve Implantation (TAVI) has a growing target population after being indicated even in low-surgical-risk patients with severe symptomatic aortic stenosis. However, postoperative outcomes can be compromised due to para-valvular leakage (PVL). A lot of procedural steps have been investigated to decrease this partially avoidable operational hazard. Oversizing is a main technique to decrease the PVL, despite being itself a risky step. Many studies have been conducted to identify the optimum degree of oversizing. However, studies about oversizing by more than 20% are scarce. We aimed to evaluate the safety and efficacy of oversizing equal to or more than 20%. RESULTS: 209 patients who underwent TAVI using the self-expandable valve Evolut R were initially included. 66 patients were excluded because of the baseline conduction disturbance and lack of sufficient data, so 143 patients, 60 females and 83 males, were enrolled in our study as two groups based on the degree of oversizing: Group A included 97 patients with an oversizing index (OI) of less than 20%, and Group B included 46 patients with an OI of 20% or more. We conducted a new technique for more accurate measuring of the OI in the context of the implantation depth, and our patients were categorized using this technique. Our findings have met our primary end point in terms of the safety and efficacy of oversizing by 20% or more. There was no significant difference between both groups in terms of new-onset conduction disturbance (NOCD), with zero cases of annular rupture or coronary encroachment. In terms of efficacy, The incidence of significant PVL (grade 2 or more) in group B was less than in group A (P value 0.007). The ROC curve found that the minimum depth of implantation-derived oversizing (DIDO) to predict no significant PVL was less than 17%. CONCLUSION: Prosthesis oversizing by 20% using the self-expandable Evolut R valve is safe and effective, with no significant effect on the conduction system, coronary encroachment, or annular injury, and warrants a greater reduction in the incidence of significant PVL.

3.
Egypt Heart J ; 73(1): 67, 2021 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-34283346

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is a well-established and standard therapy for patients with symptomatic severe aortic stenosis at moderate or high risk for surgical aortic valve replacement. Recently, it has proven non-inferior in patients with low surgical risk. However, due to its high cost, the availability of TAVI is variable worldwide. Our aim was to assess the demographic and clinical characteristics and short-term and long-term outcome of those patients. A medical registry is believed to be an excellent tool to perform a field analysis of patients' course, documenting short, intermediate, and long-term outcomes. This is the first registry for patients who underwent TAVI in Egypt. RESULTS: Ninety-six patients were included in the study; some were retrospective, and the majority were prospective from 5 different cardiac centers from August 2012 till December 2017. The mean age of patients was 77 years SD ± 7.29; females were 52% of the patients and most of the patients were overweight (BMI 30.74, SD ± 6.83). Sixty-three percent of the patients were frail with Katz index ≤ 5. 3.5% had atrial fibrillation (AF) at presentation. General anesthesia was conducted in only 59.37% of the patients. Transfemoral access was the prevailing route of implantation (90%). The median hospital stay was 4 days. In-hospital and 30 days mortality was only 4.16%. CONCLUSION: TAVI outcome in Egypt appeared to be very promising with in-hospital complication, and mortality rates being comparable to international registries (4.16% vs. 4.0% in TVT registry) denoting the procedure as safe and beneficial. Establishing a national registry is critical to highlighting strength and weaknesses as well as identifying key areas for improvements.

4.
Egypt Heart J ; 70(2): 71-75, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-30166885

RESUMO

OBJECTIVES: To determine the value of Myocardial Performance Index (MPI) as an echocardiographic predictor of early in-hospital heart failure (HF) during first acute anterior ST-Elevation Myocardial Infarction (STEMI). BACKGROUND: Myocardial infarction induces variable degrees of impairment in left ventricular (LV) systolic and diastolic functions. The ejection fraction (EF) and transmitral flow, the most frequently used methods for evaluation of systolic and diastolic functions respectively, both have considerable limitations. The MPI is a single parameter, capable of estimating combined systolic and diastolic performance and lacks such limitations. METHODS: We enrolled 60 patients presented with a first acute anterior STEMI who have undergone primary PCI. Echocardiography was done within 24 h of chest pain with measurement of MPI. The LV MPI was calculated as (isovolumic contraction time "ICT" + relaxation time "IRT")/Ejection time "ET". Besides, clinical and echocardiographic variables were analyzed and CHF was defined as Killip class ≥ II. RESULTS: Early in-hospital HF occurred in 23 of patients (38%). Ejection fraction was found to have a highly significant negative correlation with the development of in-hospital HF (p = .0001), while MPI was found to have a highly significant positive correlation (p = .0001). A cut-off point of MPI > 0.73 showed a very high specificity (94.6%) and sensitivity (78.3%) for identifying patients with HF. On the other hand, a cut-off point of EF ≤ 33% has shown 94.6% specificity and 56.5% sensitivity for HF prediction. CONCLUSIONS: The MPI might be a strong predictor of in-hospital HF after first acute anterior STEMI.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...