Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Bioelectrochemistry ; 158: 108691, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38574451

RESUMO

We present a novel application of a nanocrystalline boron-doped diamond electrode (B-NCDE) for the construction of an electrochemical DNA biosensor based on double-stranded DNA (dsDNA) for various bioanalytical applications. Surface characterization of the transducer surface (prior and after the fabrication of negatively charged O-terminated surface - O-B-NCDE) was performed by scanning electron microscopy (SEM), Raman spectroscopy, and linear sweep voltammetry (LSV) that was further used for the voltammetric determination, scan rate dependence investigation, and repeatability examination of dsDNA electrochemical oxidation at the O-B-NCDE. The fabrication of a dsDNA/O-B-NCDE biosensor via electrostatic adsorption of dsDNA involved a thorough optimization process of deposition potential (Edep), deposition time (tdep), and optimal saturation concentration (cg(satur)) with optimal values of 0.3 V, 3 min, and 10 mg/mL. The bioanalytical applicability of the fabricated dsDNA/O-B-NCDE biosensor was verified by examining the nature of the interaction between dsDNA and five selected DNA intercalators - namely thioridazine hydrochloride (TR), trimipramine maleate (TRIM), levomepromazine maleate (LEV), imipramine hydrochloride (IMI), and prochlorperazine maleate (PER) - where intercalation was proven for all of the five tested compounds. Moreover, the proposed novel bioanalytical test offers the possibility to selectively distinguish between the phenothiazine representatives (TR, LEV, and PER) and representatives of tricyclic antidepressants group (TRIM and IMI).


Assuntos
Técnicas Biossensoriais , Boro , DNA , Diamante , Eletrodos , Técnicas Biossensoriais/métodos , DNA/química , DNA/análise , Diamante/química , Boro/química , Técnicas Eletroquímicas/métodos , Nanopartículas/química
2.
Anal Chim Acta ; 1272: 341449, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37355324

RESUMO

Graphene (GR) composites have great potential for the determination of carbamates pesticides (CPs) by electrochemical methods. Since the beginning of the 20th century, GR has shown remarkable promise as electrode material for various sensors. The contamination of food products with harmful CPs is a major problem as they do not always damage human health immediately, but can be harmful after prolonged exposure. A range of advantages can be gained from their electrochemical determination, such as high sensitivity, reasonably selectivity, rapid detection, low limit of detection, and easy electrode fabrication. Furthermore, these electrochemical techniques are robust, reproducible, user-friendly, and conform to both "green" and "white" analytical chemistry. This review is focused on results published in the last ten years in the field of electrochemical determination of CPs in food products using GR and its derivatives.


Assuntos
Grafite , Praguicidas , Humanos , Praguicidas/análise , Carbamatos , Eletrodos , Técnicas Eletroquímicas/métodos
3.
Bioelectrochemistry ; 149: 108326, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36442413

RESUMO

The interaction of genotoxic environmental pollutant 2-nitrofluorene (2-NF) with double-stranded DNA has been studied using a hanging mercury drop electrode (HMDE) as an electrochemical sensor. Two types of DNA damage were investigated and electrochemically detected using cyclic voltammetry and differential pulse voltammetry: (i) DNA damage caused by the direct interaction with 2-NF and (ii) DNA damage caused by short-lived radicals generated by the electrochemical reduction of 2-NF. For the study of the direct interaction, the HMDE was modified by DNA and the interaction of DNA with 2-NF was studied after their mutual interaction right at the HMDE surface, or DNA was preincubated with 2-NF in solution and, subsequently, the interaction was studied voltammetrically. Using both detection techniques, the formation of DNA-2-NF complex was observed and the mutual interaction was interpreted as an intercalation between DNA base pairs. On the basis of obtained results, we suppose that expected formation of 8-oxoguanosine leads to guanosine-cytidine base pair interruption and DNA double-strand break formation. The binding constants (K) of the DNA-2-NF complex formed in solution and on the HMDE surface (DNA/HMDE) were determined from the changes in the voltammetric peaks of the studied analyte.


Assuntos
DNA , Mercúrio , DNA/metabolismo , Fluorenos , Eletrodos , Dano ao DNA
4.
Bioelectrochemistry ; 148: 108223, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35973323

RESUMO

This paper presents a simple and effective flow-through electrochemical biosensor, consisting of Trametes versicolor laccase (Lac)-based mini-reactor and a tubular detector of silver solid amalgam (TD-AgSA), capable of rapid and selective detection of phenolic compounds. Amperometric detection relies on the reduction of the quinone molecule (formed during the enzymatic reaction in a mini-reactor) on TD-AgSA at -50 mV vs SCE. Since different enzyme immobilization techniques may contribute to differing biosensor performances, four covalent strategies for Lac attachment were compared: (i) through glutaraldehyde to supports -NH2, (ii) via disuccinimidyl suberate to supports -NH2, (iii) using EDC/NHS for Lac coupling by its -COOH groups to supports -NH2, and (iv) using EDC/NHS to supports -COOH. Additionally, five supports (mesoporous silica (SBA-15, MCM-41), cellulose, carbon-based (glassy carbon, graphite) powders) were investigated. It was found that different methods of immobilization, as well as different types of supports, significantly affect the amount of immobilized Lac and, in turn, the analytical characteristics of the obtained biosensors. Thus, TD-AgSA with enzymatic mini-reactor based on Lac covalently attached via glutaraldehyde to aminated MCM-41 proved to be the most promising biosensor, providing the best detection limit (18.3 µmol L-1) and the long-term stability (47.9 % of the initial response/4 months/100 measurements).


Assuntos
Técnicas Biossensoriais , Grafite , Técnicas Biossensoriais/métodos , Carbono/química , Celulose , Glutaral , Lacase/química , Pós , Quinonas , Dióxido de Silício , Prata , Trametes
5.
Crit Rev Anal Chem ; : 1-33, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35867547

RESUMO

Reactive oxygen species (ROS) involving superoxide anion, hydrogen peroxide and hydroxyl radical play important role in human health. ROS are known to be the markers of oxidative stress associated with different pathologies including neurodegenerative and cardiovascular diseases, as well as cancer. Accordingly, ROS level detection in biological systems is an essential problem for biomedical and analytical research. Electrochemical methods seem to have promising prospects in ROS determination due to their high sensitivity, rapidity, and simple equipment. This review demonstrates application of modern electrochemical sensors for ROS detection in biological objects (e.g., cell lines and body fluids) over a decade between 2011 and 2021. Particular attention is paid to sensors materials and various types of modifiers for ROS selective detection. Moreover, the sensors comparative characteristics, their main advantages, disadvantages and their possibilities and limitations are discussed.

6.
Sensors (Basel) ; 21(21)2021 Nov 02.
Artigo em Inglês | MEDLINE | ID: mdl-34770608

RESUMO

Highly stable, small-sized and evenly distributed solid mercury nanoparticles capped with ibuprofen (Ibu-HgNPs) were prepared via reduction with hydrazine and capped with ibuprofen as a stabilizing agent. Characterization of Ibu-HgNPs was carried out by UV-Vis spectrophotometry and transmission electron microscopy (TEM). The prepared Ibu-HgNPs were immobilized onto a glassy carbon electrode (GCE) and used for the first time as the sensing element for voltammetric determination of low concentrations of acrylamide (AA) in aqueous solutions. Various parameters such as the type of supporting electrolyte, voltammetric mode, frequency, deposition time, stirring rate and initial potential were optimized to obtain the highest peak current of AA. The sensor delivered the best results in combination with the square wave voltammetry (SWV) mode, with good repeatability (relative standard deviation (RSD) of 25 repetitions was 1.4% for 1000 ppb AA). The study further revealed that Ibu-HgNPs are strongly adhered to GCE and hence do not contaminate the environment even after several runs. The newly developed AA sensor provides linear calibration dependence in the range of 100-1300 ppb with an R2 value of 0.996 and limit of detection (LOD) of 8.5 ppb. Negligible interference was confirmed from several organic compounds, cations and anions. The developed sensor was successfully applied for AA determination in various types of environmental real water samples to prove its practical usefulness and applicability.


Assuntos
Mercúrio , Nanopartículas , Acrilamida , Técnicas Eletroquímicas , Eletrodos , Ibuprofeno
7.
Molecules ; 26(16)2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34443639

RESUMO

Laser-reduced graphene oxide (LRGO) on a polyethylene terephthalate (PET) substrate was prepared in one step to obtain the LRGO grid electrode for sensitive carbaryl determination. The grid form results in a grid distribution of different electrochemically active zones affecting the electroactive substance diffusion towards the electrode surface and increasing the electrochemical sensitivity for carbaryl determination. Carbaryl is electrochemically irreversibly oxidized at the secondary amine moiety of the molecule with the loss of one proton and one electron in the pH range from 5 to 7 by linear scan voltammetry (LSV) on the LRGO grid electrode with a scan rate of 300 mV/s. Some interference of the juice matrix molecules does not significantly affect the LSV oxidation current of carbaryl on the LRGO grid electrode after adsorptive accumulation without applied potential. The LRGO grid electrode can be used for LSV determination of carbaryl in fruit juices in the concentration range from 0.25 to 128 mg/L with LOD of 0.1 mg/L. The fabrication of the LRGO grid electrode opens up possibilities for further inexpensive monitoring of carbaryl in other fruit juices and fruits.


Assuntos
Carbaril/química , Grafite/química , Técnicas Eletroquímicas/métodos , Eletrodos , Concentração de Íons de Hidrogênio , Lasers , Oxirredução
8.
Biosens Bioelectron ; 192: 113494, 2021 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-34303137

RESUMO

Nanozymes (NZs) are nanomaterials that mimic enzyme-like catalytic activity. They have attracted substantial attention due to their inherent physicochemical properties for use as promising alternatives to natural enzymes (NEs) in a variety of research fields. Particularly, in biosensing and bioassays, NZs have opened a new horizon to eliminate the intrinsic limitations of NEs, including their denaturation at extreme pH values and temperatures, poor reusability and recyclability, and high production costs. Moreover, the catalytic activity of NZs can be modulated in the preparation step by following an appropriate synthesis strategy. This review aims to gain insight into the potential substitution of NEs by NZs in biosensing and bioassays while considering both the pros and cons.


Assuntos
Técnicas Biossensoriais , Nanoestruturas , Bioensaio , Catálise , Enzimas
9.
Talanta ; 228: 122174, 2021 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-33773707

RESUMO

A hapten-protein conjugate with copper nanoparticles (Hap-Car-BSA@CuNPs) was first synthesized in the present work for the determination of carbaryl. The copper nanoparticles (CuNPs) of the conjugate were used as electrochemical labels in the direct solid-phase competitive determination of carbaryl residues in flour from different crops. The signal was read by linear sweep anodic stripping voltammetry (LSASV) of copper (through the electrochemical stripping of accumulated elemental copper) on a gold-graphite electrode (GGE). To form a recognition receptor layer of monoclonal antibodies against the carbaryl on the surface of the GGE, 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide hydrochloride (EDC) and 1-hydroxy-2,5-pyrrolidinedione (NHS) were used as the best covalent cross-linkers. The concentrations of the antibodies and the Hap-Car-BSA@CuNPs conjugate were optimized for carbaryl detection by the electrochemical immunosensor. The electrochemical immunosensor can be used for highly sensitive determination of carbaryl residues in flour samples in the concentration range 0.8-32.3 µg·kg-1, with a limit of detection 0.08 µg·kg-1. The present work paves the path for a novel method for monitoring carbaryl in other food products, drinks, and soil samples.


Assuntos
Técnicas Biossensoriais , Nanopartículas Metálicas , Nanopartículas , Carbaril , Cobre , Técnicas Eletroquímicas , Ouro , Imunoensaio , Limite de Detecção
10.
Talanta ; 221: 121594, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33076128

RESUMO

Novel method for the determination of a tumor marker homovanillic acid (HVA) in human urine was developed. Combination of hollow fiber - based liquid-phase microextraction (HF-LPME) and differential pulse voltammetry (DPV) at a cathodically pre-treated boron doped diamond electrode (BDDE) was applied for these purposes. Optimum conditions were: butyl benzoate as supported liquid membrane (SLM) formed on polypropylene HF, 0.1 mol L-1 HCl as donor phase, 0.1 mol L-1 sodium phosphate buffer of pH 6 as acceptor phase, and 30 min extraction time. HF-LPME-DPV concentration dependence was linear in the range from 1.2 to 100 µmol L-1. Limits of quantification (LOQ) and detection (LOD) were 1.2 and 0.4 µmol L-1, respectively. The applicability of the developed method was verified by analysis of human urine. Standard addition method was used, found HVA concentration was 13.5 ± 1.3 µmol L-1, RSD = 9.3% (n=5).


Assuntos
Biomarcadores Tumorais , Microextração em Fase Líquida , Cromatografia Líquida de Alta Pressão , Ácido Homovanílico , Humanos
11.
J Pharm Biomed Anal ; 191: 113538, 2020 Nov 30.
Artigo em Inglês | MEDLINE | ID: mdl-32919143

RESUMO

Cholesterol plays a vital role in a human body. It is known as one of the most important sterols, because it forms cell walls and participates in signal transduction. Moreover, cholesterol was recognized as biomarker of cardiovascular diseases and of some metabolic disorders. As a result, cholesterol blood levels should be controlled in a variety of diseases such as ischemic heart disease, cerebrovascular ischemia, stroke, hypertension, type II diabetes, and many others. Hence, the accurate cholesterol quantification plays an important role in diagnosis and treatment of these diseases. Modern voltammetric and amperometric methods are increasingly used for cholesterol monitoring. Consequently, the problem of electrode fabrication for cholesterol detection has high importance for clinical tests. Novel electrode materials initiated the fast growth of electrochemical biosensors. Biomaterials are still the most frequently used modifiers for cholesterol sensors due to their high selectivity. However, biomaterials have low stability complicating their practical applications. This fact is crucial for analytical parameters such as limit of detection (LOD) and sensitivity. Therefore, nanomaterials are used to eliminate disadvantages of biomaterials and to improve sensors performance by increasing the electrode surface, conductivity and sensitivity. This review is focused on the use of non-enzymatic electrodes for cholesterol quantification and on different approaches to their fabrication. Firstly, the necessity and role of modifier is discussed. Afterwards, the advantages and disadvantages of currently used modifiers are critically compared together with all aspects and approaches to sensors fabrication. Finally, the prospects of non-enzymatic electrodes application for cholesterol sensors engineering are summarised.


Assuntos
Técnicas Biossensoriais , Diabetes Mellitus Tipo 2 , Colesterol , Técnicas Eletroquímicas , Eletrodos , Humanos , Limite de Detecção
12.
Sensors (Basel) ; 20(16)2020 Aug 16.
Artigo em Inglês | MEDLINE | ID: mdl-32824351

RESUMO

A highly effective way to improve prognosis of viral infectious diseases and to determine the outcome of infection is early, fast, simple, and efficient diagnosis of viral pathogens in biological fluids. Among a wide range of viral pathogens, Flaviviruses attract a special attention. Flavivirus genus includes more than 70 viruses, the most familiar being dengue virus (DENV), Zika virus (ZIKV), and Japanese encephalitis virus (JEV). Haemorrhagic and encephalitis diseases are the most common severe consequences of flaviviral infection. Currently, increasing attention is being paid to the development of electrochemical immunological methods for the determination of Flaviviruses. This review critically compares and evaluates recent research progress in electrochemical biosensing of DENV, ZIKV, and JEV without labelling. Specific attention is paid to comparison of detection strategies, electrode materials, and analytical characteristics. The potential of so far developed biosensors is discussed together with an outlook for further development in this field.


Assuntos
Técnicas Biossensoriais , Dengue , Encefalite Japonesa , Flavivirus , Infecção por Zika virus , Dengue/diagnóstico , Encefalite Japonesa/diagnóstico , Humanos , Zika virus , Infecção por Zika virus/diagnóstico
13.
Talanta ; 218: 121136, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-32797893

RESUMO

Voltammetric determination of Tartrazine (Tz) and Brilliant Blue FCF (BB) in their mixture using novel type of carbon black-polyethylene composite electrode (CBPCE) with renewable surface modified by carbon ink (CI) was developed. Electrochemical properties of the tested dyes were investigated in 0.1 mol L-1 Britton-Robinson (BR) buffer by cyclic voltammetry (CV) and linear scan voltammetry (LSV). Simultaneous determination of the dyes is based on the application of supporting electrolytes with different pH: 2.0 for Tz and 10.0 for BB. Under the optimum experimental conditions, linear concentration dependences in the concentration ranges from 0.037 to 1.38 µmol L-1 for Tz and from 0.025 to 2.52 µmol L-1 for BB were obtained by LSV in the first-order derivative mode. Limits of detection (LODs) for Tz and BB were 0.019 and 0.011 µmol L-1, respectively. The modified electrode showed good stability and reproducibility and was successfully applied for the determination of the mixture Tz and BB in a candy and soft drink products.

14.
Bioelectrochemistry ; 135: 107576, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32502929

RESUMO

This work reports for the first time a significantly improved and simplified electrochemical immunoassay to detect antibodies to tick-borne encephalitis virus (TBEV) using a 96-well microtiter plate as a platform for immobilization and silver nanoparticles (AgNPs) as electrochemical labels. The electrochemical assay is performed by detecting the elemental silver oxidation signal where the electroactive signalling silver species are released from the bioconjugates (Ab@AgNP, AbS@AgNP, and ProteinA@AgNP). For this purpose, AgNPs were synthesized and further tagged with biomolecules (antibodies to TBEV, cleaved antibodies to TBEV, and protein A). Signal is read by linear sweep anodic stripping voltammetry (LSASV) of silver ions (through the electrochemical stripping of accumulated elemental silver) on a graphite electrode (GE). AbS@AgNP was chosen as the best option for the new electrochemical immunoassay. The results of electrochemical measurements demonstrated that voltammetric signal increased with the increasing concentration of target antibodies to TBEV within the range from 100 to 1600 IU mL-1, with a detection limit of 90 IU mL-1. To verify the practical application of the novel electrochemical immunosensor, the quantity of immunoglobulins against TBEV in human serum was checked. The results may contribute to the development of alternative methods for monitoring TBEV in biological fluids.


Assuntos
Anticorpos Antivirais/análise , Técnicas Eletroquímicas/métodos , Vírus da Encefalite Transmitidos por Carrapatos/imunologia , Imunoensaio/métodos , Nanopartículas Metálicas/química , Prata/química , Encefalite Transmitida por Carrapatos/diagnóstico , Encefalite Transmitida por Carrapatos/virologia , Humanos
15.
Bioelectrochemistry ; 134: 107539, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32361665

RESUMO

An innovative voltammetric approach to the detection of cholic and chenodeoxycholic acids is presented. These two primary bile acids are important biomarkers of liver function in humans and are involved in many physiological processes in the human body. Herein we describe a way to reproducibly convert the hard-to-detect bile acid molecule into an easily detectable derivative in situ using 0.1 M HClO4 in acetonitrile (water content 0.55%). Under these conditions the bile acids are dehydrated and the resulting alkenes can be subsequently oxidized electrochemically on polished boron-doped diamond electrode under unchanged conditions at approximately +1.2 V vs. Ag/AgNO3 in acetonitrile. After optimization, differential pulse voltammetry provides competitive limits of detection of 0.5 µM and 1.0 µM for cholic and chenodeoxycholic acid, respectively, with a linear course of calibration dependency to the minimum of 80 µM. The method was applied for detection of cholic and chenodeoxycholic acids in artificial and human serum samples using single solid phase extraction on C-18 cartridge for preliminary separation of the analytes. High recoveries of 80-90% were consistently obtained by the proposed voltammetric method and reference HPLC with fluorescence detection for human serum samples, confirming good selectivity for real-life samples.


Assuntos
Análise Química do Sangue/métodos , Ácido Quenodesoxicólico/sangue , Ácido Cólico/sangue , Eletroquímica/métodos , Humanos , Temperatura
16.
Anal Bioanal Chem ; 412(21): 5097-5104, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-31993724

RESUMO

The method for assessing the level of nitric oxide (II) (NO) by voltammetric monitoring of nitrite ions was carried out on models M1 and M2 of polarized macrophages induced from monocytes of human peripheral blood with the addition of lipopolysaccharide (LPS) and interleukin-4 (IL-4), respectively. The model of induction of M1 and M2 macrophages was used in the work to achieve the corresponding shifts in the functional status of studied cells. Ethyl nitrite (EtONO) was used as a standard compound of nitrite ions for electrochemical measurements. Electrochemical determination of nitrite ions was performed by anodic linear sweep voltammetry in the first-order derivative mode (ALSV FOD) in Britton-Robinson (BR) buffer with pH 4.02 on carbon ink modified graphite electrode. EtONO calibrations were linear over a concentration range from 2 to 9 µmol L-1 with corresponding regression equation y = 0.768c - 0.048. Limit of detection (LOD) (S/N = 3) was 0.38 µmol L-1. The results of the study showed the fundamental possibility of using voltammetry to assess indirectly the production of nitric oxide by cells in supernatants of the monocytic macrophage lineage. The level of nitric oxide metabolites (nitrite ions) in supernatants was associated with the functional state of macrophages.


Assuntos
Técnicas Eletroquímicas/métodos , Macrófagos/citologia , Nitritos/sangue , Adulto , Polaridade Celular , Meios de Cultura , Citometria de Fluxo , Humanos , Imunofenotipagem , Limite de Detecção , Macrófagos/imunologia , Macrófagos/metabolismo , Pessoa de Meia-Idade , Adulto Jovem
17.
Anal Chim Acta ; 1087: 44-50, 2019 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-31585565

RESUMO

A new method for the simultaneous determination of two tumour biomarkers, homovanillic (HVA) and vanillylmandelic acid (VMA), using flow injection analysis (FIA) with amperometric detection (AD) at a commercially available boron doped diamond electrode (BDDE) was developed. It was found that this method is suitable for the determination of HVA (in the presence of VMA) and VMA (in the presence of HVA) in optimum medium of Britton-Robinson buffer (0.04 mol L-1, pH 3.0). Calibration dependences consist of two linear parts for both biomarkers, the first one being in the concentration range from 1 to 10 µmol L-1 and the second one from 10 to 100 µmol L-1 (with obtained LODs 0.44 µmol L-1 for HVA and 0.34 µmol L-1 for VMA, respectively). To minimize any negative effects related to the passivation of the working electrode, suitable cleaning pulses (+2.4 V for 30 s) were imposed on the working electrode after each measurement. An attempt to use FIA with multiple pulse amperometric detection to determine both analytes in one run was not successful. Changing potentials in short intervals in multiple pulse detection probably results in mutual interaction of analytes and/or products of their electrochemical oxidation, thus preventing the application of this approach.


Assuntos
Biomarcadores Tumorais/análise , Boro/química , Diamante/química , Ácido Homovanílico/análise , Ácido Vanilmandélico/análise , Biomarcadores Tumorais/química , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Eletrodos , Análise de Injeção de Fluxo/métodos , Ácido Homovanílico/química , Limite de Detecção , Oxirredução , Ácido Vanilmandélico/química
18.
Sensors (Basel) ; 19(9)2019 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-31067666

RESUMO

A new simple electrochemical immunosensor approach for the determination of antibodies to tick-borne encephalitis virus (TBEV) in immunological products was developed and tested. The assay is performed by detecting the silver reduction signal in the bioconjugates with antibodies (Ab@AgNP). Here, signal is read by cathodic linear sweep voltammetry (CLSV) through the detection of silver chloride reduction on a gold-carbon composite electrode (GCCE). Covalent immobilization of the antigen on the electrode surface was performed after thiolation and glutarization of the GCCE. Specific attention has been paid to the selection of conditions for stabilizing both the silver nanoparticles and their Ab@AgNP. A simple flocculation test with NaCl was used to select the concentration of antibodies, and the additional stabilizer bovine serum albumin (BSA) was used for Ab@AgNP preparation. The antibodies to TBEV were quantified in the range from 50 IU·mL-1 to 1600 IU·mL-1, with a detection limit of 50 IU·mL-1. The coefficient of determination (r2) is 0.989. The electrochemical immunosensor was successfully applied to check the quality of immunological products containing IgG antibodies to TBEV. The present work paves the path for a novel method for monitoring TBEV in biological fluids.


Assuntos
Anticorpos Antivirais/imunologia , Técnicas Eletroquímicas/métodos , Encefalite Transmitida por Carrapatos/diagnóstico , Encefalite Transmitida por Carrapatos/imunologia , Imunoensaio/métodos , Nanopartículas Metálicas/química , Prata/química , Animais , Bovinos , Eletrodos , Vírus da Encefalite Transmitidos por Carrapatos/imunologia , Nanopartículas Metálicas/ultraestrutura , Tamanho da Partícula , Soroalbumina Bovina , Espectrofotometria Ultravioleta
19.
Anal Bioanal Chem ; 410(20): 5085-5092, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29909459

RESUMO

The treatment of some inborn metabolism errors requires cholesterol substitution therapy. Cholesterol plays a vital role in the human body. Therefore, the majority of cholesterol determination techniques are targeted to blood and blood serum. Nevertheless, cholesterol determination in food is important as well. In this paper, cholesterol determination using differential pulse voltammetry (DPV) in dairy products (e.g., milk, clotted cream, yogurt, butter, etc.) is reported with a novel nonenzymatic sensor based on diphosphonic acid of 1,4-diacetylglycoluril (DPADGU) as an electrode surface modifier. Stable anodic response was obtained from cholesterol on the modified carbon-based electrode. The sensor has high stability, sensitivity (20 µA mol L-1 cm-2), and a wide linear range from 1 up to 200 µM. The LOD and LOQ values are 1.5 and 5.1 µM, respectively. The developed methods were successfully applied to the above mentioned dairy products. Graphical abstract ᅟ.


Assuntos
Colesterol/análise , Técnicas Eletroquímicas/instrumentação , Análise de Alimentos/instrumentação , Técnicas Biossensoriais , Calibragem , Catálise , Colesterol/normas , Concentração de Íons de Hidrogênio , Padrões de Referência , Espectroscopia de Infravermelho com Transformada de Fourier
20.
Talanta ; 178: 231-236, 2018 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-29136816

RESUMO

We report the first amperometric method for the simultaneous determination of tert-butylhydroquinone (tBHQ), propyl gallate (PG), and butylated hydroxyanisole (BHA) using flow injection analysis coupled to multiple-pulse amperometry. A sequence of potential pulses was selected in order to detect tBHQ, PG, and BHA separately in a single injection step at a glassy carbon electrode without the need of a preliminary separation. A mixture of methanol and 0.040M Britton-Robinson buffer was used both as a carrier solution and for dilution of analyzed solutions before injection. The method is precise (RSD < 5%, n = 10), fast (a frequency of 140 injections h-1), provides sufficiently low quantification limits (2.51, 1.45, and 0.85µmolL-1 for tBHQ, PG, and BHA, respectively) and can be easily applied without high demands on instrumentation. As a practical application, the determination of these antioxidants contained in commercial chewing gum samples was carried out by applying a simple extraction procedure.


Assuntos
Hidroxianisol Butilado/análise , Eletroquímica/métodos , Análise de Injeção de Fluxo , Hidroquinonas/análise , Galato de Propila/análise , Goma de Mascar/análise , Eletroquímica/instrumentação , Eletrodos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...