Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 39: 291.e11-291.e14, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27903476

RESUMO

Endovascular repair of dissecting thoracoabdominal aneurysms (TAAA) is challenging and often requires multiple procedures. A 61-year-old man with a dissecting type-II TAAA treated first by placement of a thoracic endograft, and subsequently implantation of a fenestrated endograft. Six months postoperatively, a 10-mm increase of the aorta was observed. A reentry tear in left external iliac artery (EIA) was perfusing the false lumen in a retrograde fashion connecting with the endoleak caused by the inferior mesenteric artery and lumbar arteries. False lumen embolization of the left EIA and outflow vessels was performed. Thrombosis and rapid decrease of false lumen diameter was then observed. This case illustrates the complexity of endovascular management of extensive chronic aortic dissections.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/efeitos adversos , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Angiografia por Tomografia Computadorizada , Embolização Terapêutica , Endoleak/diagnóstico por imagem , Endoleak/terapia , Procedimentos Endovasculares/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Stents , Fatores de Tempo , Resultado do Tratamento
2.
Ann Vasc Surg ; 33: 187-93, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-26965825

RESUMO

BACKGROUND: In the endovascular treatment of abdominal aortic aneurysm (AAA) with short or absent infrarenal neck, the delay in the availability of fenestrated device and its high cost, have led to the manufacture of standardized models. Another option is the endografts with stents in parallel; however, regulated criteria for their use and long-term studies are lacking. The aim of this study was to assessed whether the AAA treated with fenestrated device or stents in parallel in our department, complied with the characteristics for the placement of the new endograft p-branch(®). Furthermore, the differences between the p-branch and the implanted prosthesis were analyzed. METHODS: Single-center and descriptive study of 41 aneurysms treated consecutively from 2008 to 2015. The anatomic characteristics analyzed were: relative distances between the visceral arteries, time position, diameter in the sealing area and number of fenestrations, and its compatibility with the p-branch. RESULTS: The anatomic compatibility rate with the p-branch options was 73.2% (30 cases). Of the 11 incompatible cases, 6 were due to misalignment of the visceral branches, 2 due to the aortic neck diameter being greater, another because the femoral access was inappropriate, and 2 more due to the fenestration configuration. Of the 30 cases in which compatibility existed, in 12 (40%) the configuration used coincided with the p-branch. In 13 cases, the number of fenestrations was higher than those actually used, with 23 fenestrations carried out and 39 hypothetical fenestrations with the new endograft. In the 5 remaining cases, a fenestration for the celiac trunk was necessary to achieve an adequate seal. CONCLUSIONS: The p-branch could meet the needs of three-quarters of the aortic anatomies of our series, with favorable expectations on cost and waiting time. However, in most cases either a higher number of fenestrations are needed for visceral arteries or the proximal seal was shorter than would be ideal.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Desenho de Prótese , Stents , Pontos de Referência Anatômicos , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Humanos , Espanha , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...