RESUMO
The use of CRT-D devices with left ventricular (LV) sensing has created controversy about programming various parameters especially the left ventricular T wave protection (LVTP) designed to prevent the delivery of a pacing stimulus into the LV vulnerable period. Such devices are available from two manufacturers. This review focuses only on those provided by Biotronik. As the LVTP controls LV sensing, some investigators have advocated turning off the LVTP to prevent episodic desynchronization known a CRT pacing interrupt. However, LVTP off reduces but does not eliminate this type of desynchronization if triggering of an LV stimulus upon right ventricular sensing (RVs) is programmed on. Deactivation of the LVTP incurs loss of diagnostic data provided by CRT pacing interrupt itself. By choice, the occurrence of CRT pacing interrupt can be totally eliminated by appropriate programming of the LV upper rate interval, LVTP and triggering of an LV pacing event upon RVs. Various programmability options are available according to clinical circumstances. As a rule, clinical judgement must weigh the potential diagnostic benefit of preserving the LVTP capable of recording of episodic CRT pacing interrupt against the loss of diagnostic benefit when LVTP is programmed off (with or without triggering of an LV stimulus upon RVs).
RESUMO
The year 2024 marks the centenary of Mobitz's description of type II second-degree atrioventricular block. Its definition remains valid to this day with only minor modification for the diagnosis of infranodal conduction block. Mobitz a century ago indicated that his type II atrioventricular block was associated with Stock-Adams attacks and a prolonged duration of the QRS complex before the eventual description of bundle branch block.
Assuntos
Bloqueio Atrioventricular , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Eletrocardiografia , Bloqueio de Ramo/diagnóstico , Fascículo AtrioventricularRESUMO
The fusion of narrow-QRS sinus-generated beats with end-diastolic ventricular extrasystoles occurring in bigeminy can produce an electrocardiographic pattern difficult to differentiate from parasystole. Such an ECG should not be interpreted as 2:1 RBBB because of the variability of the PR intervals.
RESUMO
Whether a pacemaker can sense concealed ventricular extrasystoles still remains debatable since its occurrence was first proposed in 1972. It must remain a diagnosis of exclusion if it really exists. Isoelectric complexes and all the causes of oversensing especially discrete false signals generated by a defective pacemaker lead must be excluded before concealed ventricular extrasystoles can be postulated.
Assuntos
Marca-Passo Artificial , Complexos Ventriculares Prematuros , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Cardíacos Prematuros , EletrocardiografiaRESUMO
This report describes two electrocardiograms (ECGs) showing unusual manifestations of left anterior hemiblock (LAH). One revealed different degrees of incomplete LAH and the other documented the occurrence of 2:1 LAH. Understanding different degrees of LAH helps to interpret the ECG with regard to intraventricular conduction disorders and other ECG abnormalities.
Assuntos
Bloqueio de Ramo , Eletrocardiografia , HumanosRESUMO
Atrial loss of capture in the chronic phase after implantation may be permanent due to various causes, e.g. technical lead problems or increased scar tissue formation around the lead tip. However, it may also be transient after atrial ischemia in the context of occlusion of the right coronary artery. In this case, it may be preferable to wait for recovery, which may take up to 45 days, instead of immediately performing an atrial lead revision.
Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Marca-Passo Artificial/efeitos adversos , Átrios do Coração , Vasos Coronários , Estimulação Cardíaca ArtificialRESUMO
The widespread use of disparate definitions of atrioventricular block has created important diagnostic problems. Adherence to the correct definitions provides a logical and simple framework for clinical evaluation. This review focuses on the clinical importance of the definitions in the diagnosis of the various types of atrioventricular (AV) block and the associated diagnostic pitfalls.
Assuntos
Bloqueio Atrioventricular , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , EletrocardiografiaRESUMO
A number of publications have claimed that Mobitz type II second-degree atrioventricular (AV) block can occur during sleep apnea. None has provided a definition of type II block used in the articles, and representative electrocardiograms have been generally missing. Despite these reports, the existence of type II AV block during sleep must remain questionable.
Assuntos
Bloqueio Atrioventricular , Humanos , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/terapia , Eletrocardiografia , SonoRESUMO
A 25 year-old woman exhibited atypical type I second degree atrioventricular block characterized by constant PR intervals except the PR interval of the beat after the block. This was attributed to vagally induced AV block with failure of the vagal effect to depress the sinus node.
Assuntos
Bloqueio Atrioventricular , Feminino , Humanos , Adulto , Bloqueio Atrioventricular/complicações , Bloqueio Atrioventricular/diagnóstico , Eletrocardiografia , Nó SinoatrialRESUMO
Problems with the definition of type II second degree AV block are best understood by reviewing the historical aspects that include Mobitz's original description, the contributions of the Chicago Arrhythmia School and the growing importance of excluding slowing of the sinus rhythm.
Assuntos
Bloqueio Atrioventricular , Humanos , Bloqueio Atrioventricular/diagnóstico , EletrocardiografiaRESUMO
This report describes a patient who underwent cardiac resynchronization complicated by a Twiddler syndrome. This caused triple atrial sensing and an inappropriate shock.
RESUMO
Some cardiac resynchronization therapy (CRT) devices equipped with left ventricular (LV) sensing can develop a specific desynchronization rhythm. Contemporary BIOTRONIK devices are designed with an algorithm called "CRT pacing interrupt" exclusively designed to record the occurrence of the specific form of desynchronization. We report six patients in whom the CRT pacing interrupt function permitted the diagnosis of slow ventricular tachycardia (VT). Slow VT was defined as slower than the programmed VT intervention rates. Although the CRT pacing interrupt function is not designed to detect slow VT, certain episodes of the CRT pacing interrupt function were falsely interpreted by the device as a desynchronization arrhythmia, and the recordings then provided data consistent with the presence of slow VT. The CRT pacing interrupt algorithm permitted a diagnosis of slow VT irrespective of the relationship of LV upper rate interval and cycle length of slow VT.
Assuntos
Ritmo Idioventricular Acelerado , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Taquicardia Ventricular , Algoritmos , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrocardiografia , Insuficiência Cardíaca/terapia , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Resultado do TratamentoRESUMO
Ventricular tachycardia (VT) with dual exit pathways has been demonstrated in many ways. In this respect we found suggestive evidence of dual exit behavior during VT in a patient with an implanted cardioverter-defibrillator. The evaluation was done with continuous recordings of the right ventricular (RV) and left ventricular (LV) electrograms. The recordings documented the varying duration of the LV to RV delay and no change in the RV rate during increases in the LV-RV delay. The unchanged rate ruled out RV participation in the VT circuit. This ruled out the presence of VT with dual exit pathways and provided proof of an unusual RV bystander that did not participate in the VT circuit.
Assuntos
Eletrocardiografia , Taquicardia Ventricular , Cardioversão Elétrica , Ventrículos do Coração , Humanos , Taquicardia Ventricular/diagnósticoRESUMO
A recently published case documented left ventricular (LV) inhibition of a Boston Scientific device by a premature complex (VPC) that was undetected by the right ventricular channel. We have observed a similar response in two patients with a BIOTRONIK cardiac resynchronization device also designed with LV sensing. A spurious response simulating that of the two true cases was also observed in a third patient with a defective LV lead which created isolated false signals. The responses of the BIOTRONIK devices were identical to that of the previously reported findings with the Boston Scientific device. The observations provide insight into the timing function of cardiac resynchronization devices designed with LV sensing.
Assuntos
Dispositivos de Terapia de Ressincronização Cardíaca , Complexos Ventriculares Prematuros/fisiopatologia , Eletrocardiografia , Falha de Equipamento , HumanosRESUMO
Non-left bundle branch block (non-LBBB) remains an uncertain indication for cardiac resynchronization therapy (CRT). Non-LBBB includes right bundle branch block (RBBB) and non-specific LV conduction delay (NSCD), two different electrocardiogram (ECG) patterns which are not generally considered to be associated with LV conduction delay as judged by the invasive assessment of the Q-LV interval. We evaluated whether a novel ECG interval (QR-max index) correlated with the degree of LV conduction delay regardless of the type of non-LBBB ECG pattern, and could, therefore, predict CRT response. In 173 non-LBBB patients on CRT (92 NSCD, 81 RBBB), the QR-max index was measured as the maximum interval from QRS onset to R-wave offset in the limb leads. The correlation between QR-max index and Q-LV interval and the impact of the QR-max index on time to first heart failure hospitalization during 3-year follow-up were assessed. Q-LV correlated better with the QR-max index than with QRSd, particularly in the RBBB group (r = 0.91; p < 0.001 vs. r = 0.19; p < 0.089), while the correlations were r = 0.79 (p < 0.01) and r = 0.68 (p < 0.01), respectively, in the NSCD group. In both groups, the QR-max index was significantly more able than QRSd to identify CRT responders (AUC 0.825 vs. 0.576; p = 0.0008 in RBBB; AUC 0.738 vs. 0.701; p = 0.459 in NSCD). A QR-max index exceeding a cutoff value of 120 ms was associated with CRT response, with predictive values of 86.8 and 81.4% in RBBB and NSCD, respectively. The QR-max index reflects the degree of LV electrical delay regardless of QRS duration in RBBB and NSCD patients and is a useful indicator of suitability for CRT in non-LBBB patients.
Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Eletrocardiografia , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Resultado do TratamentoRESUMO
Cardiac resynchronization devices that sense left ventricular (LV) activity and can detect interruptions of resynchronization therapy are able to record all forms of desynchronization rhythms, which are triggered by misalignment of LV timing cycles. We report five cases of this desynchronization rhythm that were terminated by isolated left-sided ventricular premature complexes (LVPC) undetected by the right ventricular (RV) channel and unaccompanied by changes in the duration of the RV pacing cycles. In three cases, the devices did not even sense the LVPCs responsible for desynchronization termination. The restoration of resynchronization in our cases is in contrast to the traditional termination mode that is invariably associated with changes in the duration of the RV cycles.