Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 16(3): e0247166, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33657154

RESUMO

Nontuberculous mycobacteria (NTM) are waterborne pathogens commonly found in building water systems where they are a primary concern to vulnerable patient populations and can cause severe disease. The recovery of NTM from environmental samples can be a laborious undertaking and current pre-treatment methods and selective media lack sensitivity. We explored the use of the highly selective Rapidly Growing Mycobacteria (RGM) medium for culturing NTM from environmental water samples compared to existing methods. In total, 223 environmental water samples, including potable and non-potable water, were cultured for NTM using three culture media. In addition to direct culture on RGM medium, each sample was cultured on Middlebrook 7H10 medium and Mitchison 7H11 medium after pre-treatment with 0.2M KCl-HCl. Additionally, 33 distinct species of NTM were inoculated onto RGM medium and 7H10 medium in parallel to directly compare their growth. The use of RGM medium alone without pre-treatment provided a sensitivity (91%) comparable to that offered by culture on both 7H10 and 7H11 with acid pretreatment (combined sensitivity; 86%) with significantly less overgrowth and interference from other organisms on RGM medium. The average concentration of NTM observed on RGM medium alone was comparable to or greater than the NTM concentration on either medium alone or combined. Thirty-three species were examined in parallel and all tested strains of 27 of these species successfully grew on RGM medium, including 19 of 21 from the CDC's healthcare-associated infections species list. RGM medium was successful at recovering environmental NTM without a pre-treatment, greatly reducing labor and materials required to process samples. Simplification of culture processing for environmental NTM will allow for a better assessment of their presence in building water systems and the potential for reduced exposure of susceptible populations.


Assuntos
Micobactérias não Tuberculosas , Microbiologia da Água , Humanos , Micobactérias não Tuberculosas/classificação , Micobactérias não Tuberculosas/crescimento & desenvolvimento , Micobactérias não Tuberculosas/isolamento & purificação
2.
Microorganisms ; 8(11)2020 Nov 11.
Artigo em Inglês | MEDLINE | ID: mdl-33187132

RESUMO

Water safety and management programs (WSMP) utilize field measurements to evaluate control limits and monitor water quality parameters including Legionella presence. This monitoring is important to verify that the plan is being implemented properly. However, once it has been determined when and how to sample for Legionella, it is important to choose appropriate collection and processing methods. We sought to compare processing immediate and flushed samples, filtration of different volumes collected, and sample hold times. Hot water samples were collected immediately and after a 2-min flush. These samples were plated directly and after filtration of either 100 mL, 200 mL, or 1 L. Additionally, unflushed samples were collected and processed immediately and after 1, 24, and 48 h of hold time. We found that flushed samples had significant reductions in Legionella counts compared to immediate samples. Processing 100 mL of that immediate sample both directly and after filter concentration yielded the highest concentration and percent sample positivity, respectively. We also show that there was no difference in culture values from time 0 compared to hold times of 1 h and 24 h. At 48 h, there were slightly fewer Legionella recovered than at time 0. However, Legionella counts were so variable based on sampling location and date that this hold time effect was minimal. The interpretation of Legionella culture results depends on the sample collection and processing methods used, as these can have a huge impact on the success of sampling and the validation of control measures.

3.
Am J Infect Control ; 48(2): 132-138, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31668765

RESUMO

BACKGROUND: The Centers for Medicare & Medicaid Services requires that health care facilities assess their building water systems and minimize the risk of growth and spread of Legionella and other waterborne pathogens. Increasingly, point-of-use (POU) filters are being used to prevent exposure to these pathogens. This study provides efficacy and performance specifications (membrane size, pore size, and use restrictions), which will aid in selecting POU filters. METHODS: New faucet and shower filters rated for 62 days of use were evaluated at an acute care facility in Southwestern Ontario, Canada. Five faucets and 5 showers served as controls or were equipped with filters. Hot water samples were collected weekly for 12 weeks and cultured for Legionella, heterotrophic plate count, and Pseudomonas. Literature searches for articles on POU filters used in health care settings were performed using PubMed and Google Scholar. Filter specifications from 5 manufacturers were also compared. RESULTS: The 62-day POU filters installed on both faucets and showers eliminated Legionella and reduced heterotrophic plate count concentrations for 12 weeks. No Pseudomonas was recovered during this study. Twenty peer-reviewed studies are summarized, and 21 features of 53 POU filters have been compiled. CONCLUSIONS: The information provides infection preventionists and facility engineers with information to verify claims from manufacturers and compare differences among POU products, including validated efficacy, filter design, and operational specifications.


Assuntos
Infecção Hospitalar/prevenção & controle , Filtração/instrumentação , Hospitais , Doença dos Legionários/etiologia , Microbiologia da Água , Humanos , Doença dos Legionários/microbiologia , Sistemas Automatizados de Assistência Junto ao Leito
4.
Pathogens ; 8(4)2019 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-31847120

RESUMO

Testing drinking water systems for the presence of Legionella colonization is a proactive approach to assess and reduce the risk of Legionnaires' disease. Previous studies suggest that there may be a link between Legionella positivity in the hot water return line or certain water quality parameters (temperature, free chlorine residual, etc.) with distal site Legionella positivity. It has been suggested that these measurements could be used as a surrogate for testing for Legionella in building water systems. We evaluated the relationship between hot water return line Legionella positivity and other water quality parameters and Legionella colonization in premise plumbing systems by testing 269 samples from domestic cold and hot water samples in 28 buildings. The hot water return line Legionella positivity and distal site positivity only demonstrated a 77.8% concordance rate. Hot water return line Legionella positivity compared to distal site positivity had a sensitivity of 55% and a specificity of 96%. There was poor correlation and a low positive predictive value between the hot water return line and distal outlet positivity. There was no correlation between Legionella distal site positivity and total bacteria (heterotrophic plate count), pH, free chlorine, calcium, magnesium, zinc, manganese, copper, temperature, total organic carbon, or incoming cold-water chlorine concentration. These findings suggest that hot water return line Legionella positivity and other water quality parameters are not predictive of distal site positivity and should not be used alone to determine the building's Legionella colonization rate and effectiveness of water management programs.

5.
Environ Monit Assess ; 187(7): 393, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26038316

RESUMO

This investigation compared biological quantification of potable and non-potable (cooling) water samples using pour plate heterotrophic plate count (HPC) methods and adenosine triphosphate (ATP) concentration measurement using bioluminescence. The relationship between these measurements and the presence of Legionella spp. was also examined. HPC for potable and non-potable water were cultured on R2A and PCA, respectively. Results indicated a strong correlation between HPC and ATP measurements in potable water (R = 0.90, p < 0.001). In the make-up water and two cooling towers, the correlations between ATP and HPC were much weaker but statistically significant (make-up water: R = 0.37, p = 0.005; cooling tower 1: R = 0.52, p < 0.001; cooling tower 2: R = 0.54, p < 0.001). For potable and non-potable samples, HPC exhibited higher measurement variability than ATP. However, ATP measurements showed higher microbial concentrations than HPC measurements. Following chlorination of the cooling towers, ATP measurements indicated very low bacterial concentrations (<10 colony-forming units (CFU)/mL) despite high HPC concentrations (>1000 CFU/mL) which consisted primarily of non-tuberculous mycobacteria. HPC concentrations have been suggested to be predictive of Legionella presence, although this has not been proven. Our evaluation showed that HPC or ATP demonstrated a fair predictive capacity for Legionella positivity in potable water (HPC: receiver operating characteristic (ROC) = 0.70; ATP: ROC = 0.78; p = 0.003). However, HPC or ATP correctly classified sites as positive only 64 and 62% of the time, respectively. No correlation between HPC or ATP and Legionella colonization in non-potable water samples was found (HPC: ROC = 0.28; ATP: ROC = 0.44; p = 0.193).


Assuntos
Água Potável/microbiologia , Legionella/isolamento & purificação , Microbiologia da Água , Poluentes da Água/isolamento & purificação , Trifosfato de Adenosina/metabolismo , Contagem de Colônia Microbiana , Monitoramento Ambiental , Processos Heterotróficos , Medições Luminescentes
6.
Syst Appl Microbiol ; 38(3): 198-205, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25840824

RESUMO

Opportunistic pathogens, including Legionella spp. and non-tuberculous mycobacteria, can thrive in building hot water systems despite municipal and traditional on-site chlorine disinfection. Monochloramine is a relatively new approach to on-site disinfection, but the microbiological impact of on-site chloramine use has not been well studied. We hypothesized that comparison of the microbial ecology associated with monochloramine treatment versus no on-site treatment would yield highly dissimilar bacterial communities. Hot water samples were collected monthly from 7 locations for three months from two buildings in a Pennsylvania hospital complex supplied with common municipal water: (1) a hospital administrative building (no on-site treatment) and (2) an adjacent acute-care hospital treated on-site with monochloramine to control Legionella spp. Water samples were subjected to DNA extraction, rRNA PCR, and 454 pyrosequencing. Stark differences in the microbiome of the chloraminated water and the control were observed. Bacteria in the treated samples were primarily Sphingomonadales and Limnohabitans, whereas Flexibacter and Planctomycetaceae predominated in untreated control samples. Serendipitously, one sampling month coincided with dysfunction of the on-site disinfection system that resulted in a Legionella bloom detected by sequencing and culture. This study also demonstrates the potential utility of high-throughput DNA sequencing to monitor microbial ecology in water systems.


Assuntos
Anti-Infecciosos/farmacologia , Biota/efeitos dos fármacos , Cloraminas/farmacologia , Legionella/efeitos dos fármacos , Microbiologia da Água , DNA Bacteriano/química , DNA Bacteriano/genética , DNA Bacteriano/isolamento & purificação , DNA Ribossômico/química , DNA Ribossômico/genética , DNA Ribossômico/isolamento & purificação , Hospitais , Temperatura Alta , Dados de Sequência Molecular , Pennsylvania , Reação em Cadeia da Polimerase , Análise de Sequência de DNA
7.
Water Res ; 71: 197-206, 2015 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-25618520

RESUMO

Currently, our knowledge of fungal ecology in engineered drinking water systems is limited, despite the potential for these systems to serve as a reservoir for opportunistic pathogens. In this study, hot water samples were collected both prior to and following the addition of monochloramine as an on-site disinfectant in a hospital hot water system. Fungal ecology was then analyzed by high throughput sequencing of the fungal ITS1 region. The results demonstrate that the genera Penicillium, Aspergillus, Peniophora, Cladosporium and Rhodosporidium comprised the core fungal biome of the hospital hot water system. Penicillium dominated the fungal community with an average relative abundance of 88.89% (±6.37%). ITS1 sequences of fungal genera containing potential pathogens such as Aspergillus, Candida, and Fusarium were also detected in this study. No significant change in fungal community structure was observed before and after the initiation of on-site monochloramine water treatment. This work represents the first report of the effects of on-site secondary water disinfection on fungal ecology in premise plumbing system, and demonstrates the necessity of considering opportunistic fungal pathogens during the evaluation of secondary premise plumbing disinfection systems.


Assuntos
Cloraminas/química , Desinfecção/métodos , Água Potável/microbiologia , Fungos/isolamento & purificação , Basidiomycota/isolamento & purificação , Fungos Mitospóricos/isolamento & purificação , Purificação da Água/métodos
8.
Infect Control Hosp Epidemiol ; 35(11): 1356-63, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25333430

RESUMO

OBJECTIVE: To evaluate the efficacy of a new monochloramine generation system for control of Legionella in a hospital hot water distribution system. SETTING: A 495-bed tertiary care hospital in Pittsburgh, Pennsylvania. The hospital has 12 floors covering approximately 78,000 m(2). METHODS: The hospital hot water system was monitored for a total of 29 months, including a 5-month baseline sampling period prior to installation of the monochloramine system and 24 months of surveillance after system installation (postdisinfection period). Water samples were collected for microbiological analysis (Legionella species, Pseudomonas aeruginosa, Stenotrophomonas maltophilia, Acinetobacter species, nitrifying bacteria, heterotrophic plate count [HPC] bacteria, and nontuberculous mycobacteria). Chemical parameters monitored during the investigation included monochloramine, chlorine (free and total), nitrate, nitrite, total ammonia, copper, silver, lead, and pH. RESULTS: A significant reduction in Legionella distal site positivity was observed between the pre- and postdisinfection periods, with positivity decreasing from an average of 53% (baseline) to an average of 9% after monochloramine application (P<0.5]). Although geometric mean HPC concentrations decreased by approximately 2 log colony-forming units per milliliter during monochloramine treatment, we did not observe significant changes in other microbial populations. CONCLUSIONS: This is the first evaluation in the United States of a commercially available monochloramine system installed on a hospital hot water system for Legionella disinfection, and it demonstrated a significant reduction in Legionella colonization. Significant increases in microbial populations or other negative effects previously associated with monochloramine use in large municipal cold water systems were not observed.


Assuntos
Cloraminas/farmacologia , Desinfetantes/farmacologia , Desinfecção/métodos , Legionella/efeitos dos fármacos , Microbiologia da Água , Purificação da Água/métodos , Acinetobacter/efeitos dos fármacos , Acinetobacter/crescimento & desenvolvimento , Contagem de Colônia Microbiana , Temperatura Alta , Humanos , Legionella/crescimento & desenvolvimento , Doença dos Legionários/prevenção & controle , Pseudomonas aeruginosa/efeitos dos fármacos , Pseudomonas aeruginosa/crescimento & desenvolvimento , Stenotrophomonas maltophilia/efeitos dos fármacos , Stenotrophomonas maltophilia/crescimento & desenvolvimento , Centros de Atenção Terciária , Água/química
9.
Am J Infect Control ; 42(11): 1193-6, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-25234046

RESUMO

BACKGROUND: Opportunistic waterborne pathogens (eg, Legionella, Pseudomonas) may persist in water distribution systems despite municipal chlorination and secondary disinfection and can cause health care-acquired infections. Point-of-use (POU) filtration can limit exposure to pathogens; however, their short maximum lifetime and membrane clogging have limited their use. METHODS: A new faucet filter rated at 62 days was evaluated at a cancer center in Northwestern Pennsylvania. Five sinks were equipped with filters, and 5 sinks served as controls. Hot water was collected weekly for 17 weeks and cultured for Legionella, Pseudomonas, and total bacteria. RESULTS: Legionella was removed from all filtered samples for 12 weeks. One colony was recovered from 1 site at 13 weeks; however, subsequent tests were negative through 17 weeks of testing. Total bacteria were excluded for the first 2 weeks, followed by an average of 1.86 log reduction in total bacteria compared with controls. No Pseudomonas was recovered from filtered or control faucets. CONCLUSION: This next generation faucet filter eliminated Legionella beyond the 62 day manufacturers' recommended maximum duration of use. These new POU filters will require fewer change-outs than standard filters and could be a cost-effective method for preventing exposure to Legionella and other opportunistic waterborne pathogens in hospitals with high-risk patients.


Assuntos
Filtração/métodos , Legionella/isolamento & purificação , Sistemas Automatizados de Assistência Junto ao Leito , Pseudomonas/isolamento & purificação , Microbiologia da Água , Purificação da Água/métodos , Abastecimento de Água , Infecções Bacterianas/prevenção & controle , Carga Bacteriana , Instalações de Saúde , Pennsylvania , Fatores de Tempo
10.
PLoS One ; 9(7): e102679, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25033448

RESUMO

Drinking water distribution systems, including premise plumbing, contain a diverse microbiological community that may include opportunistic pathogens. On-site supplemental disinfection systems have been proposed as a control method for opportunistic pathogens in premise plumbing. The majority of on-site disinfection systems to date have been installed in hospitals due to the high concentration of opportunistic pathogen susceptible occupants. The installation of on-site supplemental disinfection systems in hospitals allows for evaluation of the impact of on-site disinfection systems on drinking water system microbial ecology prior to widespread application. This study evaluated the impact of supplemental monochloramine on the microbial ecology of a hospital's hot water system. Samples were taken three months and immediately prior to monochloramine treatment and monthly for the first six months of treatment, and all samples were subjected to high throughput Illumina 16S rRNA region sequencing. The microbial community composition of monochloramine treated samples was dramatically different than the baseline months. There was an immediate shift towards decreased relative abundance of Betaproteobacteria, and increased relative abundance of Firmicutes, Alphaproteobacteria, Gammaproteobacteria, Cyanobacteria and Actinobacteria. Following treatment, microbial populations grouped by sampling location rather than sampling time. Over the course of treatment the relative abundance of certain genera containing opportunistic pathogens and genera containing denitrifying bacteria increased. The results demonstrate the driving influence of supplemental disinfection on premise plumbing microbial ecology and suggest the value of further investigation into the overall effects of premise plumbing disinfection strategies on microbial ecology and not solely specific target microorganisms.


Assuntos
Cloraminas/farmacologia , Desinfecção/métodos , Água Potável/microbiologia , Sistemas de Distribuição no Hospital , Purificação da Água/métodos , Actinobacteria/genética , Actinobacteria/crescimento & desenvolvimento , Sequência de Bases , Biofilmes/efeitos dos fármacos , Biofilmes/crescimento & desenvolvimento , Cianobactérias/genética , Cianobactérias/crescimento & desenvolvimento , DNA Bacteriano/genética , Desinfetantes/farmacologia , Proteobactérias/genética , Proteobactérias/crescimento & desenvolvimento , RNA Ribossômico 16S/genética , Engenharia Sanitária , Análise de Sequência de DNA , Centros de Atenção Terciária , Microbiologia da Água , Qualidade da Água
11.
Cancer Res ; 73(16): 5120-9, 2013 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-23786773

RESUMO

Gastrointestinal stromal tumors (GIST) can be successfully treated with imatinib mesylate (Gleevec); however, complete remissions are rare and patients frequently achieve disease stabilization in the presence of residual tumor masses. The clinical observation that discontinuation of treatment can lead to tumor progression suggests that residual tumor cells are, in fact, quiescent and, therefore, able to re-enter the cell-division cycle. In line with this notion, we have previously shown that imatinib induces GIST cell quiescence in vitro through the APC(CDH1)-SKP2-p27(Kip1) signaling axis. Here, we provide evidence that imatinib induces GIST cell quiescence in vivo and that this process also involves the DREAM complex, a multisubunit complex that has recently been identified as an additional key regulator of quiescence. Importantly, inhibition of DREAM complex formation by depletion of the DREAM regulatory kinase DYRK1A or its target LIN52 was found to enhance imatinib-induced cell death. Our results show that imatinib induces apoptosis in a fraction of GIST cells while, at the same time, a subset of cells undergoes quiescence involving the DREAM complex. Inhibition of this process enhances imatinib-induced apoptosis, which opens the opportunity for future therapeutic interventions to target the DREAM complex for more efficient imatinib responses.


Assuntos
Apoptose/efeitos dos fármacos , Benzamidas/farmacologia , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Tumores do Estroma Gastrointestinal/metabolismo , Proteínas Interatuantes com Canais de Kv/genética , Proteínas Interatuantes com Canais de Kv/metabolismo , Piperazinas/farmacologia , Pirimidinas/farmacologia , Proteínas Repressoras/genética , Proteínas Repressoras/metabolismo , Morte Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Tumores do Estroma Gastrointestinal/genética , Humanos , Mesilato de Imatinib , Terapia de Alvo Molecular , Proteínas Serina-Treonina Quinases/genética , Proteínas Serina-Treonina Quinases/metabolismo , Proteínas Tirosina Quinases/genética , Proteínas Tirosina Quinases/metabolismo , Quinases Dyrk
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...