Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Foot Ankle Int ; 40(5): 537-544, 2019 May.
Artigo em Inglês | MEDLINE | ID: mdl-30698469

RESUMO

BACKGROUND: Osteochondral allograft (OCA) transplantation is a useful treatment for posttraumatic ankle arthritis in young patients, but failure rates are high and reoperations are not uncommon. The aim of this study was to evaluate the outcomes of failed ankle OCA transplantation converted to ankle arthrodesis (AA) or total ankle arthroplasty (TAA). METHODS: We evaluated 24 patients who underwent salvage procedures (13 AA and 11 TAA) after primary failed ankle OCA transplantation. Reoperations were assessed. Failure of the salvage procedure was defined as an additional surgery that required a revision AA/TAA or amputation. Evaluation among nonfailing ankles included the American Academy of Orthopaedic Surgeons Foot and Ankle Module (AAOS-FAM), pain, and satisfaction. RESULTS: In the salvage AA cohort, 3 patients were classified as failures (2 revision AA and 1 amputation). The 10 nonfailing patients had a mean follow-up of 7.4 years. Eighty-eight percent were satisfied with the procedure, but 63% reported continued problems with their ankle (eg, pain, swelling, stiffness). Mean pain level was 1.9 and AAOS-FAM core score was 83±13. In the salvage TAA cohort, 2 patients were classified as failures (both revision TAA). The 9 nonfailing patients had a mean follow-up of 3.8 years. Fifty percent were satisfied with the procedure, but 40% reported continued problems with their ankle. The mean pain level was 1.3, and the median AAOS-FAM core score was 82±26. CONCLUSION: Revision and reoperation rates for salvage procedures following failed OCA transplantation of the ankle are higher compared to published data for primary AA and TAA procedures. However, we believe OCA transplantation can serve as an interim procedure for younger patients with advanced ankle joint disease who may not be ideal candidates for primary AA or TAA at the time of initial presentation. LEVEL OF EVIDENCE: Level IV, case series.


Assuntos
Articulação do Tornozelo/cirurgia , Artrodese , Artroplastia de Substituição do Tornozelo , Cartilagem Articular/transplante , Osteoartrite/cirurgia , Terapia de Salvação , Adulto , Idoso , Aloenxertos , Articulação do Tornozelo/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição da Dor , Satisfação do Paciente , Reoperação , Inquéritos e Questionários , Falha de Tratamento
2.
Foot Ankle Int ; 38(5): 502-506, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28457169

RESUMO

BACKGROUND: Arthroscopic criteria for identifying syndesmotic disruption have been variable and subjective. We aimed to quantify syndesmotic disruption arthroscopically using a standardized measurement device. METHODS: Ten cadaveric lower extremity specimens were tested in intact state and after serial sectioning of the syndesmotic structures (anterior inferior tibiofibular ligament [AiTFL], interosseous ligament [IOL], posterior inferior tibiofibular ligament [PiTFL], deltoid). Diagnostic ankle arthroscopy was performed after each sectioning. Manual external rotational stress was applied across the tibiofibular joint. Custom-manufactured spherical balls of increasing diameter mounted on the end of an arthroscopic probe were inserted into the tibiofibular space to determine the degree of diastasis of the tibiofibular joint under each condition. RESULTS: A ball 3 mm in diameter reliably indicated a high likelihood of combined disruption of the AiTFL and IOL. Disruption of the AiTFL alone could not be reliably distinguished from the intact state. CONCLUSION: Use of a spherical probe placed into the tibiofibular space during manual external rotation of the ankle provided an objective measure of syndesmotic instability. Passage of a 2.5-mm probe indicated some disruption of the syndesmosis, but the test had poor negative predictive value. Passage of a 3.0-mm spherical probe indicated very high likelihood of disruption of both the AiTFL and the IOL. CLINICAL RELEVANCE: The findings challenge the previously used but unsupported standard of a 2-mm diastasis of the tibiofibular articulation for diagnosis of subtle syndesmotic instability.


Assuntos
Traumatismos do Tornozelo/cirurgia , Artroscopia/instrumentação , Ligamentos Laterais do Tornozelo/cirurgia , Ligamentos Articulares/lesões , Fíbula , Humanos , Rotação
3.
Foot Ankle Int ; 33(11): 984-90, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23131445

RESUMO

BACKGROUND: First metatarsophalangeal (MTP) arthrodesis using dorsal plate fixation is a common procedure for painful conditions of the great toe. Locked plates have become increasingly common for arthrodesis procedures in the foot, including the hallux MTP joint. The biomechanical advantages and disadvantages of these plates are currently unknown. The purpose of this study was to compare locked and nonlocked plates used for first MTP fusion for strength and stiffness. MATERIALS AND METHODS: The first ray of nine matched pairs of fresh-frozen cadaveric feet underwent dissection, preparation with cup-and-cone reamers, and fixation of the MTP joint with a compression screw and either a nonlocked or locked stainless steel dorsal plate. Each specimen was loaded in a cantilever fashion to 90 N at a rate of 3 Hz for a total of 250,000 cycles. The amount of plantar MTP gap was recorded using a calibrated extensometer. Load-to-failure testing was performed for all specimens that endured the entire cyclical loading. Stiffness was calculated from the final load-to-failure test. RESULTS: The locked plate group demonstrated significantly less plantar gapping during fatigue endurance testing from cycle 10,000 through 250,000 (p < .05). Mean stiffness was significantly greater in the locked plate group compared with the nonlocked plate group (p = .02). There was no significant difference in load to failure between the two groups (p = .27). CONCLUSION: Compared with nonlocked plates, locked hallux MTP arthrodesis plates exhibited significantly less plantar gapping after 10,000 cycles of fatigue endurance testing and significantly greater stiffness in load-to-failure testing. CLINICAL RELEVANCE: As the use of locked plate technology is becoming increasingly common for applications in the foot, a thorough understanding of the biomechanical characteristics of these implants may help optimize their indications and clinical use.


Assuntos
Artrodese/instrumentação , Placas Ósseas , Teste de Materiais , Articulação Metatarsofalângica/cirurgia , Estresse Mecânico , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Feminino , Humanos , Masculino , Desenho de Prótese
4.
Orthopedics ; 35(6): e880-8, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22691661

RESUMO

The purpose of this study was to provide a comprehensive analysis of the Orthopaedic In-Training Examination's (OITE's) questions, question sources, and resident performance over the course of residency training.The authors analyzed all OITE questions pertaining to foot and ankle surgery between 2006 and 2010. Recorded data included the topic and area tested, imaging modality used, tested treatment method, taxonomic classification, cited references, and resident performance scores. Foot- and ankle-related questions made up 13.9% (186/1341) of the OITE questions. Thirteen general topic areas were identified, with the most common being foot and ankle trauma, the pediatric foot, and foot and ankle deformity. Imaging modalities were tested in approximately half of the questions. Knowledge of treatment modalities was required in 58.1% (108/186) of the questions. Recall-type questions were the most common. Trends existed in the recommended references, with 2 journals and 1 textbook being commonly and consistently cited: Foot and Ankle International, The Journal of Bone and Joint Surgery American Volume, and Surgery of the Foot and Ankle, respectively. Resident performance scores increased with each successive level of training.An understanding of the topics and resources used for OITE foot and ankle questions is an important aid in creating or improving residency programs' foot and ankle education curricula. With knowledge of question content, source, and resident performance, education can be optimized toward efficient learning and improved scores on this section of the examination.


Assuntos
Traumatismos do Tornozelo/cirurgia , Avaliação Educacional/estatística & dados numéricos , Traumatismos do Pé/cirurgia , Internato e Residência/estatística & dados numéricos , Ortopedia/educação , Currículo , Humanos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...