1.
J Med Eng Technol ; 31(2): 101-8, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17365434

RESUMO

PRIMARY OBJECTIVE: The prime rationale of this research is to investigate the possible occurrence of previously unrecognized episodes of desaturation apparent in preterm infants with chronic lung disease as they freely move around a non-artificial environment. RESEARCH DESIGN: The study comprises 58 hours of telemetric recordings of SpO2, heart rate, body movement and temperature, along with full ECG and photoplethysmographic waveforms for eight preterm subjects in their home environment. MAIN OUTCOME/RESULTS: The data is analysed for remarkable events, more particularly periods of spontaneous desaturation. Statistical results for all case studies are collated into a table along with examples of graphical analysis. CONCLUSIONS: This study has shown that some patients are prone to episodes of hypoxemia during the course of normal daily activity or daytime sleep that would usually go unrecognized and that more effective management of supplemental oxygen treatment may be possible with continual unobtrusive monitoring.


Assuntos
Monitorização Ambulatorial/métodos , Oximetria/métodos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Telemedicina/métodos , Feminino , Humanos , Recém-Nascido , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
J Med Eng Technol ; 25(1): 17-24, 2001.
Artigo em Inglês | MEDLINE | ID: mdl-11345096

RESUMO

PRIMARY OBJECTIVE: This communication describes the initial stage of a research project concerning the monitoring of SpO2 in infants prone to periods of spontaneous oxygen desaturation whilst freely moving around their home environment. The primary aim was to determine an appropriate probe type and site together with an assessment of the suitability of two commercially available oximeter units. RESEARCH DESIGN: The study comprised 19 comparative tests, totalling 162 hours of recordings at resolution one sample every four seconds. Comparisons are drawn between probes, probe sites and pulse oximeters. MAIN OUTCOMES/RESULTS: The bias and precision is presented with respect to the probe and measurement site. Also, correlation between the trial and reference recordings is considered. CONCLUSIONS: It is concluded that ambulatory recording of SpO2 in infants utilizing equipment suitable for home monitoring can produce diagnostic data equivalent to that of the Ohmeda 3700 biox, but that an indication of movement artefact may be required for confirmation of accuracy. It became apparent that 'wrap around' probes, used on the index finger or big toe are the most suitable.


Assuntos
Monitorização Ambulatorial/métodos , Oximetria/métodos , Criança , Humanos , Lactente , Monitorização Ambulatorial/instrumentação , Oximetria/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...