Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
J Cardiothorac Vasc Anesth ; 36(1): 242-245, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-33744111

RESUMO

Congenital factor V deficiency is an extremely rare abnormality and may be associated with significant bleeding as a result of trauma or surgery. Perioperative management primarily includes the administration of fresh frozen plasma to replace the deficient clotting factor. Acute administration of multiple blood products is a risk factor for transfusion-associated circulatory overload. Herein, the case of a 71-year-old man with an ejection fraction of 13% and a history of congenital factor V deficiency who was at risk for significant bleeding and transfusion-associated circulatory overload who underwent successful complex extraction of a right atrial pacing lead is reported.


Assuntos
Deficiência do Fator V , Reação Transfusional , Idoso , Fatores de Coagulação Sanguínea , Hemorragia , Humanos , Lasers , Masculino
2.
Am J Nephrol ; 52(5): 412-419, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33951623

RESUMO

INTRODUCTION: Atrial fibrillation (AF) is common in patients with chronic kidney disease (CKD) and is associated with higher rates of hospitalization compared to those without AF. Whether routine electrocardiographic parameters are predictive of future hospitalizations with AF is not clear. METHODS: The present study is an analysis of a prospective cohort of 2,759 patients without baseline AF from the Chronic Renal Insufficiency Cohort, a large prospective multicenter study of patients with nondialysis-dependent CKD. Unadjusted and adjusted Cox regression models were fit to examine the association of baseline categories of QTc, QRS, and PR intervals with time to first hospitalization with AF. Restricted cubic splines were used to display nonlinear associ-ations. RESULTS: The mean age of subjects at baseline was 58 ± 11 years, 55% were male, and 44% were Black. The mean follow-up was 6.6 years during which 224 participants experienced a hospitalization with AF. The association of baseline QTc interval with risk of AF hospitalization was nonlinear, such that the lowest and highest quartiles of QTc (<407 and >431 ms, respectively) had higher adjusted risk of AF hospitalization, compared with the second quartile (407-416 ms) (aHR Q1:Q2 1.58, 95% CI 1.03-2.41; p = 0.03; aHR Q4:Q2 1.84, 95% CI 1.22-2.78; p < 0.01). Longer QRS was associated with a higher risk of hospitalization with AF among the subgroup of patients with a history of heart failure (HF). PR interval was not associated with AF hospitalization. DISCUSSION/CONCLUSION: The association of QTc with risk for hospitalization with AF among patients with CKD is nonlinear, while the association of longer QRS with AF hospitalization is restricted to patients with baseline HF. Electrocardiography may represent a simple and widely accessible method for risk stratification of future AF in patients with CKD.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia/estatística & dados numéricos , Hospitalização/estatística & dados numéricos , Insuficiência Renal Crônica/complicações , Adulto , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/terapia , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Medição de Risco/métodos , Medição de Risco/estatística & dados numéricos , Fatores de Risco , Adulto Jovem
3.
Pacing Clin Electrophysiol ; 44(5): 895-902, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33675073

RESUMO

BACKGROUND: There are limited data on the comparative analyses of TightRail rotating dilator sheath (Philips) and laser sheath for lead extraction. OBJECTIVE: To evaluate the effectiveness and safety of the TightRail sheath as a primary or secondary tool for transvenous lead extraction (TLE). METHODS: Retrospective cohort analysis of 202 consecutive patients who underwent TLE using either TightRail sheath and/or GlideLight laser sheath (Philips) in our hospital. The study population was divided into three groups: Group A underwent TLE with laser sheath only (N = 157), Group B with TightRail sheath only (N = 22), and Group C with both sheaths (N = 23). RESULTS: During this period, 375 leads in 202 patients were extracted, including 297 leads extracted by laser sheath alone, 45 leads by TightRail sheath alone, and 33 by both TightRail sheath and laser sheaths. The most common indications included device infection (44.6%) and lead-related complications (44.1%). The median age of leads was 8.9 years. TightRail sheath (Group B) achieved similar efficacy as a primary extraction tool compared with laser sheath (Group A), with complete procedure success rate of 93.3% (vs. 96.6%, P = .263) and clinical success rate of 100.0% (vs. 98.1%, P = .513). Among 32 leads in which Tightrail was used after laser had failed (Group C), the complete procedure success rate was 75.8%. No significant difference in procedural adverse events was observed. CONCLUSION: Our single-center experience confirms that the TightRail system is an effective first-line and second-line method for TLE. Further investigation is required to guide the selection of mechanical and laser sheaths in lead extraction cases.


Assuntos
Remoção de Dispositivo/instrumentação , Eletrodos Implantados , Desfibriladores Implantáveis , Desenho de Equipamento , Feminino , Humanos , Lasers , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Estudos Retrospectivos
4.
J Cardiovasc Electrophysiol ; 32(5): 1281-1289, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33625757

RESUMO

INTRODUCTION: We previously introduced the inverse solution guidance algorithm (ISGA) methodology using a Single Equivalent Moving Dipole model of cardiac electrical activity to localize both the exit site of a re-entrant circuit and the tip of a radiofrequency (RF) ablation catheter. The purpose of this study was to investigate the use of ISGA for ablation catheter guidance in an animal model. METHODS: Ventricular tachycardia (VT) was simulated by rapid ventricular pacing at a target site in eleven Yorkshire swine. The ablation target was established using three different techniques: a pacing lead placed into the ventricular wall at the mid-myocardial level (Type-1), an intracardiac mapping catheter (Type-2), and an RF ablation catheter placed at a random position on the endocardial surface (Type-3). In each experiment, one operator placed the catheter/pacing lead at the target location, while another used the ISGA system to manipulate the RF ablation catheter starting from a random ventricular location to locate the target. RESULTS: The average localization error of the RF ablation catheter tip was 0.31 ± 0.08 cm. After analyzing approximately 35 cardiac cycles of simulated VT, the ISGA system's accuracy in locating the target was 0.4 cm after four catheter movements in the Type-1 experiment, 0.48 cm after six movements in the Type-2 experiment, and 0.67 cm after seven movements in the Type-3 experiment. CONCLUSION: We demonstrated the feasibility of using the ISGA method to guide an ablation catheter to the origin of a VT focus by analyzing a few beats of body surface potentials without electro-anatomic mapping.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Algoritmos , Animais , Catéteres , Coração , Suínos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia
5.
ESC Heart Fail ; 8(2): 999-1006, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33506638

RESUMO

There have been nearly 70 million cases of COVID-19 worldwide, with over 1.5 million deaths at the time of this publication. This global pandemic has mandated dramatic changes in healthcare delivery with a particular focus on social distancing in order to reduce viral transmission. Heart failure patients are among the highest utilizers of health care and are at increased risk for COVID-related vulnerabilities. Effectively managing this complex and resource-intensive patient population from a distance presents new and unique challenges. Here, we review relevant data on telemedicine and remote monitoring strategies for heart failure patients and provide a framework to help providers treat this population during the COVID-19 pandemic. This includes (i) dedicated pre-visit contact and planning (i.e. confirm clinical appropriateness, presence of compatible technology, and patient comfort); (ii) utilization of virtual clinic visits (use of telehealth platforms, a video-assisted exam, self-reported vital signs, and weights); and (iii) use of existing remote heart failure monitoring sensors when applicable (CardioMEMS, Optivol, and HeartLogic). While telemedicine and remote monitoring strategies are not new, these technologies are emerging as an important tool for the effective management of heart failure patients during the COVID-19 pandemic. In general, these strategies appear to be safe; however, additional data will be needed to determine their effectiveness with respect to both process and outcomes measures.


Assuntos
COVID-19/epidemiologia , Controle de Doenças Transmissíveis , Insuficiência Cardíaca/terapia , Telemedicina/organização & administração , COVID-19/prevenção & controle , COVID-19/transmissão , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Humanos
6.
J Interv Card Electrophysiol ; 58(3): 323-331, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31456103

RESUMO

We have developed a system that could potentially be used to identify the site of origin of ventricular tachycardia (VT) and to guide a catheter to that site to deliver radio-frequency ablation therapy. This system employs the Inverse Solution Guidance Algorithm based upon Single Equivalent Moving Dipole (SEMD) localization method. The system was evaluated in in vivo swine experiments. Arrays consisting of 9 or 16 bipolar epicardial electrodes and an additional mid-myocardial pacing lead were sutured to each ventricle. Focal tachycardia was simulated by applying pacing pulses to each epicardial electrode at multiple pacing rates during breath hold at the end-expiration phase. Surface potentials were recorded from 64 surface electrodes and then analyzed using the SEMD method to localize the position of the pacing electrodes. We found a close correlation between the locations of the pacing electrodes as measured in computational and real spaces. The reproducibility error of the SEMD estimation of electrode location was 0.21 ± 0.07 cm. The vectors between every pair of bipolar electrodes were computed in computational and real spaces. At 120 bpm, the lengths of the vectors in the computational and real space had a 95% correlation. Computational space vectors were used in catheter guidance simulations which showed that this method could reduce the distance between the real space locations of the emulated catheter tip and the emulated arrhythmia origin site by approximately 72% with each movement. We have demonstrated the feasibility of using our system to guide a catheter to the site of the emulated VT origin.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Algoritmos , Animais , Mapeamento Potencial de Superfície Corporal , Catéteres , Humanos , Reprodutibilidade dos Testes , Suínos , Taquicardia Ventricular/cirurgia
8.
Europace ; 19(10): 1657-1663, 2017 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-27702847

RESUMO

AIMS: Controversy on the optimal ablation strategy for persistent atrial fibrillation (AF) exists with limited work evaluating a strategy of pulmonary vein isolation (PVI) alone when AF terminates during PVI. Thirty-five patients had AF termination during PVI in the Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF; ClinicalTrials.gov number: NCT01014741) study. The objective of the current study is to report the 1-year outcome after PVI alone in this unique patient group. METHODS AND RESULTS: The 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs was reported for the 35 patients in the MAGIC-AF study with persistent AF termination during or upon completion of PVI. Freedom from recurrent atrial arrhythmia was achieved in 60% of patients where AF terminated during PVI. Cavotricuspid isthmus flutter was common when AF terminated to a macro re-entrant flutter during PVI, and responsible for 92% of all flutter circuits with AF termination. CONCLUSIONS: Persistent AF termination during PVI may identify a subgroup of patients who experience a similar long-term clinical outcome with PVI ablation alone when compared with other more extensive persistent AF ablation strategies. Pulmonary vein isolation alone may be an appropriate tactic in this subgroup of persistent AF patients.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Flutter Atrial/etiologia , Canadá , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Método Duplo-Cego , Eletrocardiografia Ambulatorial , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Sistema de Registros , República da Coreia , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
9.
J Cardiovasc Electrophysiol ; 27(11): 1259-1263, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27461576

RESUMO

INTRODUCTION: Atrial fibrillation (AF) ablation is less frequently performed in women when compared to men. There are conflicting data on the safety and efficacy of AF ablation in women. The objective of this study was to compare the clinical characteristics and outcomes in a contemporary cohort of men and women undergoing persistent AF ablation procedures. METHODS AND RESULTS: A total of 182 men and 53 women undergoing a first-ever persistent AF catheter ablation procedure in The Modified Ablation Guided by Ibutilide Use in Chronic Atrial Fibrillation (MAGIC-AF) trial were evaluated. Clinical and procedural characteristics were compared between each gender. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Women undergoing catheter ablation procedures were older than men (P < 0.001). The duration of AF and associated co-morbidities were similar between both genders. Single procedure drug-free atrial arrhythmia recurrence occurred in 53% of the cohort with no difference based on gender (men = 54%, women = 53%; P = 1.0). Procedural (P = 0.04), fluoroscopic (P = 0.02), and ablation times (P = 0.003) were shorter in women compared to men. Periprocedural complications and postablation improvement in quality of life were similar between men and women. CONCLUSION: Women undergoing a first-ever persistent AF ablation procedure were older but had similar clinical outcomes and complications when compared with men.

10.
Cardiol Clin ; 34(2): 307-16, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27150179

RESUMO

Catheter ablation has become a widely available and accepted treatment to restore sinus rhythm in atrial fibrillation patients who fail antiarrhythmic drug therapy. Although generally safe, the procedure carries a non-negligible risk of complications, including periprocedural cerebral insults. Uninterrupted anticoagulation, maintenance of an adequate ACT during the procedure, and measures to avoid and detect thrombus build-up on sheaths and atheters during the procedure, appears useful to reduce the risk of embolic events. This is a review of the incidence, mechanisms, impact, and methods to reduce catheter ablation related cerebral insults.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Acidente Vascular Cerebral/epidemiologia , Fibrilação Atrial/complicações , Saúde Global , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Incidência , Fatores de Risco , Acidente Vascular Cerebral/etiologia
11.
Eur Heart J ; 37(20): 1614-21, 2016 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-26850076

RESUMO

AIMS: Complex fractionated atrial electrograms (CFAE) are targeted during persistent atrial fibrillation (AF) ablation. However, many CFAE sites are non-specific resulting in extensive ablation. Ibutilide has been shown to reduce left atrial surface area exhibiting CFAE. We hypothesized that ibutilide administration prior to CFAE ablation would identify sites critical for persistent AF maintenance allowing for improved procedural efficacy and long-term freedom from atrial arrhythmias. METHODS AND RESULTS: Two hundred patients undergoing a first-ever persistent AF catheter ablation procedure were randomly assigned to receive either 0.25 mg of intravenous ibutilide or saline placebo upon completion of pulmonary vein isolation. Complex fractionated atrial electrogram sites were then targeted with ablation. The primary efficacy endpoint was the 1-year single procedure freedom from atrial arrhythmia off anti-arrhythmic drugs. Similar procedural characteristics (procedure, fluoroscopy, and ablation times) were observed with both strategies despite a greater reduction in left atrial surface area with CFAE sites (8 vs. 1%, P < 0.0001) and AF termination during CFAE ablation with ibutilide compared with placebo (75 vs. 57%, P = 0.007). The primary efficacy endpoint was achieved in 56% of patients receiving ibutilide and 49% receiving placebo (P = 0.35). No significant differences in peri-procedural complications were observed in both groups. CONCLUSION: Despite a reduction in CFAE area and greater AF termination during CFAE ablation, procedural characteristics and clinical outcomes were unchanged when CFAE ablation was guided by ibutilide administration. CLINICAL TRIAL REGISTRATION INFORMATION: ClinicalTrials.gov number: NCT01014741.


Assuntos
Fibrilação Atrial/tratamento farmacológico , Sulfonamidas/uso terapêutico , Ablação por Cateter , Doença Crônica , Técnicas Eletrofisiológicas Cardíacas , Humanos , Veias Pulmonares , Resultado do Tratamento
12.
Cardiol Rev ; 24(5): 218-23, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26274538

RESUMO

Non-vitamin K antagonist oral anticoagulants (NOACs) are frequently used to prevent stroke in patients with atrial fibrillation. These patients are often also on aspirin or other antiplatelet agents. It is possible that treatment with both NOACs and aspirin or other antiplatelet drug may be effective in decreasing stroke, but data are sparse regarding the efficacy and safety of using both agents for stroke prevention. To address these issues, data were pooled from the 4 recent randomized, controlled trials of NOACs: apixaban, rivaroxaban, dabigatran, and edoxaban, which included 42,411 patients; 14,148 (33.4%) were also on aspirin or other antiplatelet drug. The number of thromboembolic events among participants on NOAC and aspirin/antiplatelet was compared with the number of events in patients on NOAC alone. Bleeding rates were also compared between those on NOAC + aspirin/antiplatelet and on NOAC alone. These results were compared with thromboembolic and bleeding events in the warfarin + aspirin/antiplatelet versus warfarin alone. No greater risk for thromboembolism was seen in patients on NOACs compared with patients on both NOACs and aspirin/antiplatelet drug. In this nonrandomized comparison, there was initially a signal toward higher thromboembolic rates among NOAC users also on aspirin/antiplatelet drugs (relative risk, 1.16; 95% confidence intervals, 1.05, 1.29) when compared with NOAC alone. This likely reflected the higher CHADS2 scores of those on aspirin/antiplatelet drugs. When the analysis was limited to studies that included aspirin rather than other antiplatelet drugs, no difference was seen for thromboembolic rates comparing dual therapy to NOAC alone (relative risk, 1.02; 95% confidence intervals, 0.90, 1.15). Higher rates of bleeding were seen with aspirin/antiplatelet drug in conjunction with NOAC. In this meta-analysis and nonrandomized comparison of aspirin/antiplatelet users and nonusers also on anticoagulation, there was no additional benefit seen of anticoagulation and antiplatelet therapy for stroke prevention when compared with anticoagulation alone. There was, however, an increased risk of bleeding. Careful assessment of the indications for antiplatelet drugs in patients with atrial fibrillation who are also receiving oral anticoagulants is warranted, and future randomized comparisons are needed.


Assuntos
Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Hemorragia/induzido quimicamente , Inibidores da Agregação Plaquetária/uso terapêutico , Acidente Vascular Cerebral/prevenção & controle , Tromboembolia/prevenção & controle , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/etiologia , Tromboembolia/etiologia
13.
J Cardiovasc Comput Tomogr ; 9(4): 313-20, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25977115

RESUMO

BACKGROUND: Myocardial scar is a substrate for ventricular tachycardia and sudden cardiac death. Late enhancement CT imaging can detect scar, but it remains unclear whether newer late enhancement dual-energy (LE-DECT) acquisition has benefit over standard single-energy late enhancement (LE-CT). OBJECTIVE: We aim to compare late enhancement CT using newer LE-DECT acquisition and single-energy LE-CT acquisitions with pathology and electroanatomic map (EAM) in an experimental chronic myocardial infarction (MI) porcine study. METHODS: In 8 pigs with chronic myocardial infarction (59 ± 5 kg), we performed dual-source CT, EAM, and pathology. For CT imaging, we performed 3 acquisitions at 10 minutes after contrast administration: LE-CT 80 kV, LE-CT 100 kV, and LE-DECT with 2 postprocessing software settings. RESULTS: Of the sequences, LE-CT 100 kV provided the best contrast-to-noise ratio (all P ≤ .03) and correlation to pathology for scar (ρ = 0.88). LE-DECT overestimated scar (both P = .02), whereas LE-CT images did not (both P = .08). On a segment basis (n = 136), all CT sequences had high specificity (87%-93%) and modest sensitivity (50%-67%), with LE-CT 100 kV having the highest specificity of 93% for scar detection compared to pathology and agreement with EAM (κ = 0.69). CONCLUSIONS: Standard single-energy LE-CT, particularly 100 kV, matched better to pathology and EAM than dual-energy LE-DECT for scar detection. Larger human trials as well as more technical studies that optimize varying different energies with newer hardware and software are warranted.


Assuntos
Mapeamento Potencial de Superfície Corporal , Cicatriz/diagnóstico , Infarto do Miocárdio/diagnóstico , Miocárdio Atordoado/diagnóstico , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Animais , Cicatriz/etiologia , Meios de Contraste/administração & dosagem , Masculino , Infarto do Miocárdio/complicações , Miocárdio Atordoado/etiologia , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Suínos
14.
J Am Heart Assoc ; 3(5): e001055, 2014 Sep 03.
Artigo em Inglês | MEDLINE | ID: mdl-25187521

RESUMO

BACKGROUND: This study investigates the hypothesis that morphologic analysis of intracardiac electrograms provides a sensitive approach to detect acute myocardial infarction or myocardial infarction-induced arrhythmia susceptibility. Large proportions of irreversible myocardial injury and fatal ventricular tachyarrhythmias occur in the first hour after coronary occlusion; therefore, early detection of acute myocardial infarction may improve clinical outcomes. METHODS AND RESULTS: We developed a method that uses the wavelet transform to delineate electrocardiographic signals, and we have devised an index to quantify the ischemia-induced changes in these signals. We recorded body-surface and intracardiac electrograms at baseline and following myocardial infarction in 24 swine. Statistically significant ischemia-induced changes after the initiation of occlusion compared with baseline were detectable within 30 seconds in intracardiac left ventricle (P<0.0016) and right ventricle-coronary sinus (P<0.0011) leads, 60 seconds in coronary sinus leads (P<0.0002), 90 seconds in right ventricle leads (P<0.0020), and 360 seconds in body-surface electrocardiographic signals (P<0.0022). Intracardiac leads exhibited a higher probability of detecting ischemia-induced changes than body-surface leads (P<0.0381), and the right ventricle-coronary sinus configuration provided the highest sensitivity (96%). The 24-hour ECG recordings showed that the ischemic index is statistically significantly increased compared with baseline in lead I, aVR, and all precordial leads (P<0.0388). Finally, we showed that the ischemic index in intracardiac electrograms is significantly increased preceding ventricular tachyarrhythmic events (P<0.0360). CONCLUSIONS: We present a novel method that is capable of detecting ischemia-induced changes in intracardiac electrograms as early as 30 seconds following myocardial infarction or as early as 12 minutes preceding tachyarrhythmic events.


Assuntos
Mapeamento Potencial de Superfície Corporal/métodos , Eletrocardiografia Ambulatorial/métodos , Isquemia Miocárdica/diagnóstico , Processamento de Sinais Assistido por Computador , Taquicardia Ventricular/diagnóstico , Animais , Modelos Animais de Doenças , Progressão da Doença , Diagnóstico Precoce , Eletrocardiografia/métodos , Masculino , Distribuição Aleatória , Sensibilidade e Especificidade , Suínos , Fatores de Tempo
15.
Pacing Clin Electrophysiol ; 37(8): 1038-50, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24645803

RESUMO

BACKGROUND: We have introduced a method to guide radiofrequency catheter ablation (RCA) procedures that estimates the location of a catheter tip used to pace the ventricles and the target site for ablation using the single equivalent moving dipole (SEMD). OBJECTIVE: To investigate the accuracy of this method in resolving epicardial and endocardial electrical sources. METHODS: Two electrode arrays, each of nine pacing electrodes at known distances from each other, sutured on the left- and right-ventricular (LV and RV) epicardial surfaces of swine, were used to pace the heart at multiple rates, while body surface potentials from 64 sites were recorded and used to estimate the SEMD location. A similar approach was followed for pacing from catheters in the LV and RV. RESULTS: The overall (RV & LV) error in estimating the interelectrode distance of adjacent epicardial electrodes was 0.38 ± 0.45 cm. The overall endocardial (RV & LV) interelectrode distance error, was 0.44 ± 0.26 cm. Heart rate did not significantly affect the error of the estimated SEMD location (P > 0.05). The guiding process error became progressively smaller as the SEMD approached an epicardial target site and close to the target, the overall absolute error was ∼ 0.28 cm. The estimated epicardial SEMD locations preserved their topology in image space with respect to their corresponding physical location of the epicardial electrodes. CONCLUSION: The proposed algorithm suggests one can efficiently and accurately resolve epicardial electrical sources without the need of an imaging modality. In addition, the error in resolving these sources is sufficient to guide RCA procedures.


Assuntos
Algoritmos , Fontes de Energia Bioelétrica , Ablação por Cateter/métodos , Animais , Fenômenos Eletrofisiológicos , Suínos
16.
Ann Cardiothorac Surg ; 3(1): 91-7, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24516805

RESUMO

Over the past two decades, invasive techniques to treat atrial fibrillation (AF) including catheter-based and surgical procedures have evolved along with our understanding of the pathophysiology of this arrhythmia. Surgical treatment of AF may be performed on patients undergoing cardiac surgery for other reasons (concomitant surgical ablation) or as a stand-alone procedure. Advances in technology and technique have made surgical intervention for AF more widespread. Despite improvements in outcome of both catheter-based and surgical treatment for AF, recurrence of atrial arrhythmias following initial invasive therapy may occur.Atrial arrhythmias may occur early or late in the post-operative course after surgical ablation. Early arrhythmias are generally treated with prompt electrical cardioversion with or without antiarrhythmic therapy and do not necessarily represent treatment failure. The mechanism of persistent or late occurring atrial arrhythmias is complex, and these arrhythmias may be resistant to antiarrhythmic drug therapy. The characterization and management of recurrent atrial arrhythmias following surgical ablation of AF are discussed below.

17.
J Am Coll Cardiol ; 63(10): 982-8, 2014 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-24412445

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the feasibility and safety of uninterrupted rivaroxaban therapy during atrial fibrillation (AF) ablation. BACKGROUND: Optimal periprocedural anticoagulation strategy is essential for minimizing bleeding and thromboembolic complications during and after AF ablation. The safety and efficacy of uninterrupted rivaroxaban therapy as a periprocedural anticoagulant for AF ablation are unknown. METHODS: We performed a multicenter, observational, prospective study of a registry of patients undergoing AF ablation in 8 centers in North America. Patients taking uninterrupted periprocedural rivaroxaban were matched by age, sex, and type of AF with an equal number of patients taking uninterrupted warfarin therapy who were undergoing AF ablation during the same period. RESULTS: A total of 642 patients were included in the study, with 321 in each group. Mean age was 63 ± 10 years, with 442 (69%) males and 328 (51%) patients with paroxysmal AF equally distributed between the 2 groups. Patients in the warfarin group had a slightly higher mean HAS- BLED (hypertension, abnormal renal/liver function, stroke, bleeding history or predisposition, labile international normalized ratio, elderly, drugs/alcohol concomitantly) score (1.70 ± 1.0 vs. 1.47 ± 0.9, respectively; p = 0.032). Bleeding and embolic complications occurred in 47 (7.3%) and 2 (0.3%) patients (both had transient ischemic attacks) respectively. There were no differences in the number of major bleeding complications (5 [1.6%] vs. 7 [1.9%], respectively; p = 0.772), minor bleeding complications (16 [5.0%] vs. 19 [5.9%], respectively; p = 0.602), or embolic complications (1 [0.3%] vs. 1 [0.3%], respectively; p = 1.0) between the rivaroxaban and warfarin groups in the first 30 days. CONCLUSIONS: Uninterrupted rivaroxaban therapy appears to be as safe and efficacious in preventing bleeding and thromboembolic events in patients undergoing AF ablation as uninterrupted warfarin therapy.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Morfolinas/administração & dosagem , Tiofenos/administração & dosagem , Tromboembolia/prevenção & controle , Administração Oral , Idoso , Anticoagulantes/administração & dosagem , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Relação Dose-Resposta a Droga , Inibidores do Fator Xa , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Período Perioperatório , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Sistema de Registros , Rivaroxabana , Resultado do Tratamento
18.
Card Electrophysiol Clin ; 6(1): 111-23, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27063826

RESUMO

Transcatheter treatment of atrial fibrillation (AF) is a complex intervention performed in patients who are at inherently increased risk of a thromboembolic complication, including stroke. It is therefore not surprising that cerebrovascular accidents have been among the most feared complications since the inception of AF ablation. While improvements have been made to limit the incidence of thromboembolic events during catheter ablation of AF, the optimal strategy to minimize such complications has yet to be determined. It is hoped that larger trials using periprocedural anticoagulation strategies can be undertaken to definitively address these important concerns.

19.
Interv Cardiol Clin ; 3(2): 219-227, 2014 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28582167

RESUMO

This article reviews novel techniques in stroke prevention based on epicardial closure of the left atrial appendage, illustrating the features of the first endo-epicardial device currently available and those of devices still in development. It also provides further information about early clinical experience with the endo-epicardial device.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...