Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
2.
Comput Aided Surg ; 3(6): 289-96, 1998.
Artigo em Inglês | MEDLINE | ID: mdl-10379978

RESUMO

Procedures were performed to evaluate the efficacy of using a computer-assisted image-guided system to improve the accuracy of inserting iliosacral screws for posterior pelvic ring injuries. The fluoroscopic method currently in use has shortcomings that do not eliminate the risk to the L5 and sacral nerve roots and iliac vessels. The procedure was performed on embalmed cadaver pelvis specimens with intact soft tissues. Iliosacral screws were inserted across each sacroiliac joint after registering the opposite ilium to simulate a clinical situation. Two trials were performed. The first was necessary to become familiar with the system and test the basic methods of registration. In the second trial, deficiencies were corrected by using spherical-headed fiducial screws for fiducials and a better reference frame clamp, and by better spacing of more fiducials. Results were evaluated by inlet and outlet X-ray views and dissection. All eight S-1 iliosacral 7.0-mm cannulated screws were entirely inside bone. Of the eight S-2 screws, five were inside bone, two infringed upon an S-1 foramen, and one had threads out of the sacral body anteriorly and intruding into an S-1 foramen. This system was felt to be effective and sufficiently safe to warrant clinical trials.


Assuntos
Parafusos Ósseos , Articulação Sacroilíaca/cirurgia , Terapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Ílio , Sacro
3.
J Orthop Trauma ; 7(3): 248-51, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-8326430

RESUMO

A modified freehand method using a cannulated drill bit for the insertion of distal locking screws for interlocking intramedullary nails is described. It should be useful to introduce surgeons to interlocking and to aid those who are not comfortable with the freehand method.


Assuntos
Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Fraturas da Tíbia/cirurgia , Humanos
4.
5.
J Orthop Trauma ; 4(2): 144-50, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2358928

RESUMO

In this series of 41 cases of acute fractures of the femur treated with the Brooker-Wills nail, 20 technical problems with insertion or removal of the nail occurred in 19 of the total. Final outcomes were determined in 33 cases followed for 1 year or more. Technical difficulties had a deleterious effect on the outcome in three of these 33 cases. Mechanical failure seems to be a significant problem with the Brooker-Wills system in this and other series. We found that bending of the proximal nail during the insertion, breaking of the tip of the distal fixator inserter, and detachment of the blades from the fixator shaft had occurred. Although satisfactory results were obtained in this series, comparable to other "start-up" series, it is our opinion that the advantages of the Brooker-Wills nail over other interlocking nails are outweighed by the disadvantages of difficult insertion and removal.


Assuntos
Pinos Ortopédicos/efeitos adversos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Parafusos Ósseos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
9.
J Bone Joint Surg Am ; 60(2): 269-71, 1978 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-641098

RESUMO

Thirty-eight displaced intracapsular fractures of the femoral neck treated by the Deyerle method of internal fixation have been added to the previously reported series of sixty-three cases from the Walter Reed Army Medical Center Orthopaedic Service. A significant change in the incidence of non-union was found. In the over-all series of 101 patients, the incidence of non-union was 13.8 per cent and the incidence of segmental collapse due to avascular necrosis was 13.8 per cent. The roentgenographic and functional over-all end results were rated excellent in 67.7 per cent and poor in 32.3 per cent of the fractures. Some difficulties arising from the multiple-pin and plate technique and the associated morbidity are discussed. We now think that Deyerle method produces no better results than other methods of internal fixation of displaced intracapsular fractures.


Assuntos
Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Pinos Ortopédicos , Placas Ósseas , Estudos de Avaliação como Assunto , Necrose da Cabeça do Fêmur/etiologia , Seguimentos , Fraturas não Consolidadas , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...