Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Am J Public Health ; 105(1): 13-18, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25393187

RESUMO

Tracking of infectious diseases is a public health core function essential to disease prevention and control. Each state mandates reporting of certain infectious diseases to public health authorities. These laws vary by state, and the variation could affect the ability to collect critical information. The 2009 H1N1 influenza pandemic served as a case study to examine the legal authority in the 50 states; Washington, DC; and New York City for mandatory infectious disease reporting, particularly for influenza and new or emerging infectious diseases. Our study showed reporting laws to be generally present and functioning well; nevertheless, jurisdictions should be mindful of their mandated parameters and review the robustness of their laws before they face a new or emerging disease outbreak.

2.
Resuscitation ; 73(1): 54-61, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17258853

RESUMO

BACKGROUND: Cardiopulmonary resuscitation (CPR) quality during actual cardiac arrest has been found to be deficient in several recent investigations. We hypothesized that real-time feedback during CPR would improve the performance of chest compressions and ventilations during in-hospital cardiac arrest. METHODS: An investigational monitor/defibrillator with CPR-sensing and feedback capabilities was used during in-hospital cardiac arrests from December 2004 to December 2005. Chest compression and ventilation characteristics were recorded and quantified for the first 5 min of resuscitation and compared to a baseline cohort of arrest episodes without feedback, from December 2002 to April 2004. RESULTS: Data from 55 resuscitation episodes in the baseline pre-intervention group were compared to 101 resuscitations in the feedback intervention group. There was a trend toward improvement in the mean values of CPR variables in the feedback group with a statistically significant narrowing of CPR variable distributions including chest compression rate (104+/-18 to 100+/-13 min(-1); test of means, p=0.16; test of variance, p=0.003) and ventilation rate (20+/-10 to 18+/-8 min(-1); test of means, p=0.12; test of variance, p=0.04). There were no statistically significant differences between the groups in either return of spontaneous circulation or survival to hospital discharge. CONCLUSIONS: Real-time CPR-sensing and feedback technology modestly improved the quality of CPR during in-hospital cardiac arrest, and may serve as a useful adjunct for rescuers during resuscitation efforts. However, feedback specifics should be optimized for maximal benefit and additional studies will be required to assess whether gains in CPR quality translate to improvements in survival.


Assuntos
Reanimação Cardiopulmonar/normas , Desfibriladores , Retroalimentação , Parada Cardíaca/terapia , Cardioversão Elétrica , Desenho de Equipamento , Feminino , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Garantia da Qualidade dos Cuidados de Saúde
3.
Resuscitation ; 71(2): 137-45, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16982127

RESUMO

BACKGROUND: Cardiopulmonary resuscitation (CPR) and electrical defibrillation are the primary treatment options for ventricular fibrillation (VF). While recent studies have shown that providing CPR prior to defibrillation may improve outcomes, the effects of CPR quality remain unclear. Specifically, the clinical effects of compression depth and pauses in chest compression prior to defibrillation (pre-shock pauses) are unknown. METHODS: A prospective, multi-center, observational study of adult in-hospital and out-of-hospital cardiac resuscitations was conducted between March 2002 and December 2005. An investigational monitor/defibrillator equipped to measure compression characteristics during CPR was used. RESULTS: Data were analyzed from 60 consecutive resuscitations in which a first shock was administered for VF. The primary outcome was first shock success defined as removal of VF for at least 5s following defibrillation. A logistic regression analysis demonstrated that successful defibrillation was associated with shorter pre-shock pauses (adjusted odds ratio 1.86 for every 5s decrease; 95% confidence interval 1.10-3.15) and higher mean compression depth during the 30s of CPR preceding the pre-shock pause (adjusted odds ratio 1.99 for every 5mm increase; 95% confidence interval 1.08-3.66). CONCLUSIONS: The quality of CPR prior to defibrillation directly affects clinical outcomes. Specifically, longer pre-shock pauses and shallow chest compressions are associated with defibrillation failure. Strategies to correct these deficiencies should be developed and consideration should be made to replacing current-generation automated external defibrillators that require long pre-shock pauses for rhythm analysis.


Assuntos
Reanimação Cardiopulmonar/métodos , Cardioversão Elétrica/métodos , Parada Cardíaca/terapia , Avaliação de Resultados em Cuidados de Saúde , Fibrilação Ventricular/terapia , Idoso , Feminino , Parada Cardíaca/mortalidade , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Garantia da Qualidade dos Cuidados de Saúde , Fibrilação Ventricular/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA