Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Chem ; 35(9): 2003-8, 1989 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-2776341

RESUMO

This patient, on admission, presented with a tentative diagnosis of myocardial infarction: the electrocardiogram showed a nonspecific ST-segment and T-wave abnormalities, and total creatine kinase (CK; EC 2.7.3.2) activity was slightly increased (238 U/L). However, a high electrophoretic value for CK-MB (50% of total CK activity) and the electrophoretic pattern of lactate dehydrogenase (EC 1.1.1.27) isoenzymes ruled out myocardial infarction. The isoenzyme migrating as CK-MB was found later to contain no immunologically normal CK-M subunits, and it was bound to IgA. A mixture of the patient's serum and a human serum control containing all CK isoenzymes showed altered electrophoretic mobility only for CK-BB, indicating that the patient's serum contained antibodies to the B unit of CK. Elution from a Sephadex G-200 column showed that the peak at which most of the anodic CK was eluted corresponded to a molecular mass of approximately 200 kDa. Evidently this atypical isoenzyme was an IgA-CK-BB complex. Because this macro CK type 1 can mimic CK-MB, it may therefore be a source of confusion.


Assuntos
Creatina Quinase/sangue , Imunoglobulina A/análise , Infarto do Miocárdio/enzimologia , Creatina Quinase/imunologia , Erros de Diagnóstico , Eletroforese/métodos , Humanos , Isoenzimas , L-Lactato Desidrogenase/sangue , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico , Espectrometria de Fluorescência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...