Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Craniomaxillofac Surg ; 46(4): 578-587, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29530645

RESUMO

PURPOSE: Reconstruction of orbital wall fractures is demanding and has improved dramatically with the implementation of new technologies. True-to-original accuracy of reconstruction has been deemed essential for good clinical outcome, and reasons for unfavorable clinical outcome have been researched extensively. However, no detailed analysis on the influence of plate position and surface contour on clinical outcome has yet been published. MATERIALS AND METHODS: Data from a previous study were used for an ad-hoc analysis to identify predictors for unfavorable outcome, defined as diplopia or differences in globe height and/or globe projection of >2 mm. Presumed predictors were implant surface contour, aberrant implant dimension or position, accuracy of reconstructed orbital volume, and anatomical fracture topography according to the current AO classification. RESULTS: Neither in univariable nor in multivariable regression models were unfavorable clinical outcomes associated with any of the presumed radiological predictors, and no association of the type of implant, i.e., standard preformed, CAD-based individualized and non-CAD-based individualized with its surface contour could be shown. CONCLUSION: These data suggest that the influence of accurate mechanical reconstruction on clinical outcomes may be less predictable than previously believed, while the role of soft-tissue-related factors may have been underestimated.


Assuntos
Placas Ósseas , Órbita/cirurgia , Fraturas Orbitárias/cirurgia , Adulto , Desenho Assistido por Computador , Humanos , Imageamento Tridimensional/métodos , Masculino , Órbita/diagnóstico por imagem , Órbita/lesões , Fraturas Orbitárias/diagnóstico por imagem , Estudos Prospectivos , Desenho de Prótese , Procedimentos de Cirurgia Plástica/métodos , Resultado do Tratamento
2.
J Craniomaxillofac Surg ; 44(9): 1485-97, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27519662

RESUMO

PURPOSE: A variety of implants are available for orbital reconstruction. Titanium orbital mesh plates are available either as standard preformed implants or able to be individualized for the patient. The aim of this study was to analyze whether individualized orbital implants allow a more precise reconstruction of the orbit than standard preformed implants. MATERIALS AND METHODS: A total of 195 patients treated between 2010 and 2014 were followed up to 12 weeks after surgery. Of the patients, 100 had received standardized preformed and 95 individualized implants. The precision of orbital reconstruction with the different implants was determined by comparing the variances in the volume difference between the reconstructed and the contralateral orbit on the postoperative computed tomographic scans. Clinical volume-related parameters including globe position, vision, motility, and diplopia and surgical details including approach, timing and technique of implant modification, use of navigation, duration of surgery, as well as adverse events were documented. RESULTS: Orbital reconstruction was significantly more precise when individualized implants were used. The same was seen with intraoperative navigation. An overlap in the use of individualized implants and navigation makes it difficult to attribute the improved precision to a single factor. CONCLUSION: This study demonstrated that individualization and navigation provide clinical benefit.


Assuntos
Fraturas Orbitárias/cirurgia , Implantes Orbitários , Adulto , Desenho Assistido por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Procedimentos de Cirurgia Plástica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...