Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Biomed Mater Res A ; 104(7): 1728-35, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26946064

RESUMO

Extracellular matrix (ECM) materials from animal and human sources have become important materials for soft tissue repair. Microparticles of ECM materials have increased surface area and exposed binding sites compared to sheet materials. Decellularized porcine peritoneum was mechanically dissociated into 200 µm microparticles, seeded with fibroblasts and cultured in a low gravity rotating bioreactor. The cells avidly attached and maintained excellent viability on the microparticles. When the seeded microparticles were placed in a collagen gel, the cells quickly migrated off the microparticles and through the gel. Cells from seeded microparticles migrated to and across an in vitro anastomosis model, increasing the tensile strength of the model. Cell seeded microparticles of ECM material have potential for paracrine and cellular delivery therapies when delivered in a gel carrier. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1728-1735, 2016.


Assuntos
Sistemas de Liberação de Medicamentos/métodos , Matriz Extracelular/metabolismo , Microesferas , Modelos Biológicos , Cicatrização , Anastomose Cirúrgica , Animais , Movimento Celular , Colágeno , Fibroblastos/citologia , Humanos , Sus scrofa , Resistência à Tração
2.
Tissue Eng Part A ; 21(15-16): 2147-55, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26020102

RESUMO

Chronic lower respiratory disease is highly prevalent in the United States, and there remains a need for alternatives to lung transplant for patients who progress to end-stage lung disease. Portable or implantable gas oxygenators based on microfluidic technologies can address this need, provided they operate both efficiently and biocompatibly. Incorporating biomimetic materials into such devices can help replicate native gas exchange function and additionally support cellular components. In this work, we have developed microfluidic devices that enable blood gas exchange across ultra-thin collagen membranes (as thin as 2 µm). Endothelial, stromal, and parenchymal cells readily adhere to these membranes, and long-term culture with cellular components results in remodeling, reflected by reduced membrane thickness. Functionally, acellular collagen-membrane lung devices can mediate effective gas exchange up to ∼288 mL/min/m(2) of oxygen and ∼685 mL/min/m(2) of carbon dioxide, approaching the gas exchange efficiency noted in the native lung. Testing several configurations of lung devices to explore various physical parameters of the device design, we concluded that thinner membranes and longer gas exchange distances result in improved hemoglobin saturation and increases in pO2. However, in the design space tested, these effects are relatively small compared to the improvement in overall oxygen and carbon dioxide transfer by increasing the blood flow rate. Finally, devices cultured with endothelial and parenchymal cells achieved similar gas exchange rates compared with acellular devices. Biomimetic blood oxygenator design opens the possibility of creating portable or implantable microfluidic devices that achieve efficient gas transfer while also maintaining physiologic conditions.


Assuntos
Colágeno/química , Células Endoteliais da Veia Umbilical Humana/metabolismo , Dispositivos Lab-On-A-Chip , Membranas Artificiais , Oxigênio/metabolismo , Adesão Celular , Células Endoteliais da Veia Umbilical Humana/citologia , Humanos
3.
Front Biosci (Landmark Ed) ; 19(8): 1227-39, 2014 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-24896347

RESUMO

Lung tissue engineering is an emerging field focused on the development of lung replacement devices and tissue to treat patients with end stage lung disease. Microfluidic based lung assist devices have been developed that have biomimetically designed vascular networks that achieve physiologic blood flow. Gas exchange in these devices occurs across a thin respiratory membrane. Designed for intrathoracic implantation as a bridge to transplant or destination therapy, these lung assist devices will allow ambulation and hospital discharge for patients with end stage lung disease. Decellularized lungs subsequently recellularized with epithelial and endothelial cells have been implanted in small animal models with demonstration of initial gas exchange. Further development of these tissues and scaling to large animal models will validate this approach and may be an organ source for lung transplantation. Initial clinical success has been achieved with decellularized tracheal implants using autologous stem cells. Development of microfluidic lung models using similar architecture to the lung assist device technology allows study of lung biology and diseases with manipulation of lung cells and respiratory membrane strain.


Assuntos
Órgãos Bioartificiais , Pulmão/citologia , Engenharia Tecidual/métodos , Animais , Vasos Sanguíneos/citologia , Vasos Sanguíneos/fisiologia , Humanos , Pulmão/irrigação sanguínea , Pulmão/fisiologia , Técnicas Analíticas Microfluídicas/métodos , Modelos Biológicos , Troca Gasosa Pulmonar , Alicerces Teciduais
4.
J R Soc Interface ; 10(87): 20130413, 2013 Oct 06.
Artigo em Inglês | MEDLINE | ID: mdl-23904585

RESUMO

Engineered cartilage is a promising option for auricular reconstruction. We have previously demonstrated that a titanium wire framework within a composite collagen ear-shaped scaffold helped to maintain the gross dimensions of the engineered ear after implantation, resisting the deformation forces encountered during neocartilage maturation and wound healing. The ear geometry was redesigned to achieve a more accurate aesthetic result when implanted subcutaneously in a nude rat model. A non-invasive method was developed to assess size and shape changes of the engineered ear in three dimensions. Computer models of the titanium framework were obtained from CT scans before and after implantation. Several parameters were measured including the overall length, width and depth, the minimum intrahelical distance and overall curvature values for each beam section within the framework. Local curvature values were measured to gain understanding of the bending forces experienced by the framework structure in situ. Length and width changed by less than 2%, whereas the depth decreased by approximately 8% and the minimum intrahelical distance changed by approximately 12%. Overall curvature changes identified regions most susceptible to deformation. Eighty-nine per cent of local curvature measurements experienced a bending moment less than 50 µN-m owing to deformation forces during implantation. These quantitative shape analysis results have identified opportunities to improve shape fidelity of engineered ear constructs.


Assuntos
Orelha/anatomia & histologia , Engenharia Tecidual/métodos , Alicerces Teciduais , Animais , Cartilagem , Próteses e Implantes , Ratos , Propriedades de Superfície , Titânio
5.
ASAIO J ; 57(6): 533-8, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22036722

RESUMO

Blood oxygenators are vital for the critically ill, but their use is limited to the hospital setting. A portable blood oxygenator or a lung assist device for ambulatory or long-term use would greatly benefit patients with chronic lung disease. In this work, a biomimetic blood oxygenator system was developed which consisted of a microfluidic vascular network covered by a gas permeable silicone membrane. This system was used to determine the influence of key microfluidic parameters-channel size, oxygen exposure length, and blood shear rate-on blood oxygenation and carbon dioxide removal. Total gas transfer increased linearly with flow rate, independent of channel size and oxygen exposure length. On average, CO(2) transfer was 4.3 times higher than oxygen transfer. Blood oxygen saturation was also found to depend on the flow rate per channel but in an inverse manner; oxygenation decreased and approached an asymptote as the flow rate per channel increased. These relationships can be used to optimize future biomimetic vascular networks for specific lung applications: gas transfer for carbon dioxide removal in patients with chronic obstructive pulmonary disease or oxygenation for premature infants requiring complete lung replacement therapy.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Hemodinâmica/fisiologia , Troca Gasosa Pulmonar/fisiologia , Desenho de Equipamento
6.
Biomaterials ; 32(16): 3883-9, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21396705

RESUMO

Membranes for a lung assist device must permit the exchange of gaseous O2 and CO2 while simultaneously acting as a liquid barrier, so as to prevent leakage of blood and its components from passing from one side to the other. Additionally, these membranes must be capable of being integrated into microfluidic devices possessing a vascular network. In this work, uniform, large-area, ultra-thin, polymeric free-standing membranes (FSMs) and composite membranes (CMs) are reproducibly fabricated by initiated Chemical Vapor Deposition (iCVD). The 5 µm thick FSMs remained intact during handling and exhibited a CO2 permeance that was 1.3 times that of the control membrane (8 µm thick spun-cast membrane of silicone). The CMs consisted of a dense iCVD skin layer (0.5-3 µm thick) deposited on top of a polytetrafluoroethylene (PTFE) support membrane (20 µm thick, 100 nm pores). The CMs exhibited CO2 and O2 permeance values 50-300 times that of the control membrane. The FSMs were subjected to mechanical testing to assess the impact of the absence of an underlying support structure. The CMs were subjected to liquid barrier tests to ensure that while they were permeable to gases, they acted as barriers to liquids. Both FSMs and CMs were integrated into silicone microfluidic devices and tested for bond integrity.


Assuntos
Membranas Artificiais , Técnicas Analíticas Microfluídicas/métodos , Oxigenadores de Membrana , Materiais Biocompatíveis , Permeabilidade
7.
Tissue Eng Part A ; 17(11-12): 1573-81, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21284558

RESUMO

Engineered cartilage composed of a patient's own cells can become a feasible option for auricular reconstruction. However, distortion and shrinkage of ear-shaped constructs during scaffold degradation and neocartilage maturation in vivo have hindered the field. Scaffolds made of synthetic polymers often generate degradation products that cause an inflammatory reaction and negatively affect neocartilage formation in vivo. Porous collagen, a natural material, is a promising candidate; however, it cannot withstand the contractile forces exerted by skin and surrounding tissue during normal wound healing. We hypothesised that a permanent support in the form of a coiled wire embedded into a porous collagen scaffold will maintain the construct's size and ear-specific shape. Half-sized human adult ear-shaped fibrous collagen scaffolds with and without embedded coiled titanium wire were seeded with sheep auricular chondrocytes, cultured in vitro for up to 2 weeks, and implanted subcutaneously on the backs of nude mice. After 6 weeks, the dimensional changes in all implants with wire support were minimal (2.0% in length and 4.1% in width), whereas significant reduction in size occurred in the constructs without embedded wire (14.4% in length and 16.5% in width). No gross distortion occurred over the in vivo study period. There were no adverse effects on neocartilage formation from the embedded wire. Histologically, mature neocartilage extracellular matrix was observed throughout all implants. The amount of DNA, glycosaminoglycan, and hydroxyproline in the engineered cartilage were similar to that of native sheep ear cartilage. The embedded wire support was essential for avoiding shrinkage of the ear-shaped porous collagen constructs.


Assuntos
Orelha/fisiologia , Engenharia Tecidual/métodos , Alicerces Teciduais/química , Adulto , Animais , Cartilagem/patologia , Colágeno/metabolismo , DNA/metabolismo , Matriz Extracelular/metabolismo , Glicosaminoglicanos/metabolismo , Humanos , Hidroxiprolina/metabolismo , Imuno-Histoquímica , Camundongos , Camundongos Nus , Maleabilidade , Ovinos
8.
Lab Chip ; 11(4): 700-7, 2011 Feb 21.
Artigo em Inglês | MEDLINE | ID: mdl-21152606

RESUMO

There is no technology available to support failing lung function for patients outside the hospital. An implantable lung assist device would augment lung function as a bridge to transplant or possible destination therapy. Utilizing biomimetic design principles, a microfluidic vascular network was developed for blood inflow from the pulmonary artery and blood return to the left atrium. Computational fluid dynamics analysis was used to optimize blood flow within the vascular network. A micro milled variable depth mold with 3D features was created to achieve both physiologic blood flow and shear stress. Gas exchange occurs across a thin silicone membrane between the vascular network and adjacent alveolar chamber with flowing oxygen. The device had a surface area of 23.1 cm(2) and respiratory membrane thickness of 8.7 ± 1.2 µm. Carbon dioxide transfer within the device was 156 ml min(-1) m(-2) and the oxygen transfer was 34 ml min(-1) m(-2). A lung assist device based on tissue engineering architecture achieves gas exchange comparable to hollow fiber oxygenators yet does so while maintaining physiologic blood flow. This device may be scaled up to create an implantable ambulatory lung assist device.


Assuntos
Materiais Biomiméticos , Pulmão/irrigação sanguínea , Técnicas Analíticas Microfluídicas/instrumentação , Alicerces Teciduais , Animais , Circulação Sanguínea , Dióxido de Carbono , Bovinos , Simulação por Computador , Humanos , Modelos Cardiovasculares , Oxigênio , Desenho de Prótese , Troca Gasosa Pulmonar/fisiologia
9.
Proc Natl Acad Sci U S A ; 106(14): 5540-5, 2009 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-19307560

RESUMO

Insertion of trocars, needles, and catheters into unintended tissues or tissue compartments results in hundreds of thousands of complications annually. Current methods for blood vessel cannulation or epidural, chest tube, and initial trocar placement often involve the blind pass of a needle through several layers of tissue and generally rely on distinguishable anatomic landmarks and a high degree of clinical skill. To address this simply and without the use of electronics, a purely mechanical clutch system was developed for use in medical devices that access tissue and tissue compartments. This clutch utilizes the surface contact of a buckled filament inside an S-shaped tube to transmit force from the filament (catheter/guide wire) to the tube (needle). Upon encountering sufficient resistance at the tip, such as dense tissue, the catheter buckles and locks within the tube, causing the filament and needle to advance as one. When the needle reaches the target tissue or fluid-filled cavity, the filament unlocks and slides freely into the target region while the needle remains stationary. A similar locking phenomenon has long been observed in drill strings inside drill shafts used by the oil-drilling industry, and oil industry models were adapted to describe the motion of this clutch system. A predictive analytical model was generated and validated with empirical data and used to develop prototypes of a complete device then tested in vitro on muscle tissue and in vivo on a porcine laparoscopic model with promising results.


Assuntos
Cateteres de Demora , Agulhas , Animais , Biópsia por Agulha Fina/instrumentação , Cateterismo/instrumentação , Desenho de Equipamento , Laparoscopia , Músculos , Suínos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...