Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Appl Radiat Isot ; 70(1): 144-8, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21945017

RESUMO

This paper presents the application of a computational methodology for optimizing the conversion of medical tomographic images in voxel anthropomorphic models for simulation of radiation transport using the MCNP code. A computational system was developed for digital image processing that compresses the information from the DICOM medical image before it is converted to the Scan2MCNP software input file for optimization of the image data. In order to validate the computational methodology, a radiosurgery treatment simulation was performed using the Alderson Rando phantom and the acquisition of DICOM images was performed. The simulation results were compared with data obtained with the BrainLab planning system. The comparison showed good agreement for three orthogonal treatment beams of (60)Co gamma radiation. The percentage differences were 3.07%, 0.77% and 6.15% for axial, coronal and sagital projections, respectively.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/radioterapia , Método de Monte Carlo , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Humanos , Imageamento Tridimensional/instrumentação , Imageamento Tridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos
2.
J Appl Clin Med Phys ; 11(1): 2947, 2010 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-20160687

RESUMO

The purpose of this study is to investigate the influence of lung heterogeneity inside a soft tissue phantom on percentage depth dose (PDD). PDD curves were obtained experimentally using LiF:Mg,Ti (TLD-100) thermoluminescent detectors and applying Eclipse treatment planning system algorithms Batho, modified Batho (M-Batho or BMod), equivalent TAR (E-TAR or EQTAR), and anisotropic analytical algorithm (AAA) for a 15 MV photon beam and field sizes of 1 x 1, 2 x 2, 5 x 5, and 10 x 10 cm 2 . Monte Carlo simulations were performed using the DOSRZnrc user code of EGSnrc. The experimental results agree with Monte Carlo simulations for all irradiation field sizes. Comparisons with Monte Carlo calculations show that the AAA algorithm provides the best simulations of PDD curves for all field sizes investigated. However, even this algorithm cannot accurately predict PDD values in the lung for field sizes of 1 x 1 and 2 x 2 cm 2 . An overdosage in the lung of about 40% and 20% is calculated by the AAA algorithm close to the interface soft tissue/lung for 1 x 1 and 2 x 2 cm 2 field sizes, respectively. It was demonstrated that differences of 100% between Monte Carlo results and the algorithms Batho, modified Batho, and equivalent TAR responses may exist inside the lung region for the 1 x 1 cm 2 field.


Assuntos
Neoplasias Pulmonares/radioterapia , Pulmão/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador , Dosimetria Termoluminescente , Algoritmos , Carga Corporal (Radioterapia) , Humanos , Pulmão/patologia , Neoplasias Pulmonares/patologia , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Eficiência Biológica Relativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...