1.
Int J Biomater ; 2021: 5584766, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34373696

RESUMO

The main aim is to evaluate the cyclic fatigue resistance of blue heat-treated instruments with different kinematics. Twenty-four endodontic instruments of the same brand were used for each of three experimental groups: VB (Vortex Blue 40/0.04), RB (RECIPROC Blue 40/0.06), and XB (X1 Blue 40/0.06). The instruments were randomly distributed and subjected to temperatures of 20°C and 37°C. The fatigue test was performed using a stainless steel device. Data were analysed using the Shapiro-Wilk test, Student's t-test, the F test, and Tukey's and Tamhane tests at significance level P=0.05. The instruments' cyclic fatigue resistance at both temperatures differed significantly for each instrument type (P < 0.001). The RB instruments displayed greater cyclic fatigue resistance at the tested temperatures compared with the VB and XB instruments (P < 0.001). Reciprocating kinematics positively influenced cyclic fatigue resistance. Blue heat-treated instruments showed decreased cyclic fatigue resistance as the temperature increased (P < 0.001).

2.
Iran Endod J ; 16(1): 1-16, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-36704409

RESUMO

Introduction: Our study aimed to compare the incidence and intensity of postoperative pain after endodontic instrumentation with reciprocating and rotary systems. Methods and Materials: An electronic literature search was performed with MEDLINE via PubMed, Scopus, and Web of Science databases from January 2008 to June 2020. Two high-impact endodontic journals were also hand searched. The selection criteria were: 1) Population; patients requiring endodontic treatment (primary or secondary), 2) Intervention and Comparison; endodontic instrumentation with reciprocating versus rotary systems, and 3) Outcome; postoperative pain. We extrapolated all included research data and reported them as dichotomized ordinal variables to evaluate the incidence of pain and continuous variables to assess pain intensity. Standardized mean difference (SMD) was calculated with Inverse Variance method for pain intensity; the incidence of postoperative pain was calculated using relative risk (RR) with the Mantel-Haenszel method. Random-effects model and 95% confidence interval (CI) were used for all meta-analyses. The I2 statistic was used to evaluate the statistical heterogeneity among studies (P<0.05). Results: Twenty-one articles were selected and 17 of them were included in the meta-analysis for the evaluation of postoperative pain in the first 24 h. The meta-analysis was performed in two steps: a) all studies were included; b) subsequently studies with preoperative pain were excluded. A significant difference was observed in the intensity of postoperative pain; with rotary system having more favorable in both steps [a) SMD: 0.27; 95% CI: 0.13 to 0.41; P=0.0002; b) SMD: 0.37; 95% CI: 0.15 to 0.58; P=0.0010]. There was no significant difference in the incidence of pain, and the incidence of mild, moderate and severe pain (P>0.05). Conclusion: The meta-analysis results revealed that rotary system were the instrument of choice as they had lower intensity of postoperative pain. Further controlled studies are advocated to provide clarification for intensity/incidence of postoperative pain in endodontic treatment with mechanized instruments.

3.
J Contemp Dent Pract ; 20(6): 697-701, 2019 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-31358712

RESUMO

AIM: This study aims to investigate the influence of temperatures of 20 °C and 37 °C on the resistance to cyclic fatigue of NiTi instruments with different heat treatments, as tested in severely curved simulated canals. MATERIALS AND METHODS: Seventy-two instruments were distributed according to the temperature used (20 °C and 37 °C): XP-endo Shaper (30/0.01), ProDesign Logic (30/0.05), and iRaCe (30/0.04). The instruments were rotated freely until the occurrence of fracture inside an artificial severely curved stainless steel canal, which had a 90° angle of curvature and a curvature radius of 5 mm. Kolmogorov-Smirnov, Wilcoxon, ANOVA, and Kruskal-Wallis tests were performed. A p value of <0.05 was considered statistically significant. RESULTS: XP-endo Shaper instruments presented higher NCF values and time to failure compared with ProDesign Logic and iRaCe instruments at 20 °C and 37 °C (p < 0.001). CONCLUSION: Within the limitations of this study, the results show that the body temperature (37 °C) significantly lowers the resistance to cyclic fatigue of all instruments compared with 20 °C. CLINICAL SIGNIFICANCE: Body temperature is an important factor in the results of cyclic fatigue tests.


Assuntos
Níquel , Titânio , Instrumentos Odontológicos , Desenho de Equipamento , Fadiga , Temperatura Alta , Humanos , Preparo de Canal Radicular , Temperatura
4.
Iran Endod J ; 13(2): 263-266, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29707026

RESUMO

Dens invaginatus is characterized by invagination of enamel and dentin in the dental papilla prior to tissue calcification. This malformation commonly occurs in the maxillary lateral incisors. The present study reports two complex endodontic treatments in Oehlers' type II and III dens invaginatus, with periapical lesion and presence of bone resorption. In the reported cases, conventional endodontic therapy was successful and sufficient enough to eliminate the infectious process, allowing periapical bone neoformation and absence of symptomatology. Dens invaginatus is a relatively easy-to-diagnose dental malformation. However, it is necessary to know its radiographic aspects. The treatment results demonstrated that, although the cases of dens invaginatus of high complexity are challenging, an accurate diagnosis accompanied with proper endodontic treatment can avoid unnecessary surgical intervention and allow great chances of favorable prognosis in long term.

5.
Iran Endod J ; 12(4): 468-473, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29225643

RESUMO

INTRODUCTION: Endodontic instruments are developed to provide a better cleaning of the root canal system and reduce its risk of fracture. The aim of this study was to evaluate the instrumentation time and cyclic fatigue resistance of WaveOne Gold, ProDesign R and ProDesign Logic files. METHODS AND MATERIALS: Thirty Nickel-titanium (NiTi) rotary instruments were divided into 3 groups (n=10). ProDesign Logic file 25/0.06 was used in continuous rotation after glide path preparation. WaveOne Gold 25/0.07 and ProDesign R 25/0.06 files were used in reciprocating motion. Every file instrumented 3 standardized artificial canals. The average time, the number of cycles (NCI) and cyclic fatigue resistance of each file were determined through the number of cycles to failure (NCF) in a stainless-steel device. The total amount of cycles to fracture was also calculated (NCI+NCF). Data was analyzed using the Kruskal-Wallis and Mann-Whitney tests. RESULTS: The instrumentation time of the ProDesign Logic file was significantly lower when compared to the other files (P=0.019). The longest times to failure were presented by ProDesign Logic (182.07 sec) and ProDesign R (152.38 sec) files. The same differences were observed for the NCF (910.37 and 761.93). The WaveOne Gold group presented a lower NCF as well as a smaller sum of NCI+NCF (748.33) that was statistically significant when compared to the other groups (P<0.05) respectively. CONCLUSION: The use of continuous rotational motion in canals with a glide path in the ProDesign Logic group led to shorter instrumentation time. The cyclic fatigue resistance of ProDesign R and Logic instruments was superior to WaveOne Gold. The thermal treatment of the instrument's alloy, its cross section and the glide path seems to influence the cyclic fatigue resistance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...