Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
World J Urol ; 41(8): 2289-2295, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37418016

RESUMO

PURPOSE: Our objective was to analyse the clinical efficiency of TFL in large volume stones during retrograde intrarenal surgery. MATERIALS AND METHODS: Patients with large volume renal stones (> 1000 mm3) operated at two different centres, from May 2020 to April 2021, were enrolled in this study. Retrograde intrarenal surgery was performed using 60W Superpulse thulium fibre laser™ (IPG Photonics, Russia). Demographic data, stone parameters, laser time, and total operating time were recorded, and laser efficacy (J/mm3) and ablation speed (mm3/s) were calculated. NCCT KUB was done at 3 months postoperatively to calculate stone-free rate. RESULTS: A total of 76 patients were included and analysed in the study. Mean stone volume was 1753.12 ± 1245.81 (1169.27-2193.25) mm3, mean stone density was 1104.46 ± 313.09 (875.00-1317.00) HU, mean laser time was 537.79 ± 689.89 (21.00-1080.00) sec, mean operating time was 43.38 ± 12.96 (35.00-51.25) min, mean laser efficacy was 20.30 ± 15.5 (8.88-25.57) J/mm3, and mean ablation speed was 1.32 ± 0.7 (0.82-1.64) mm3/sec. A strong positive correlation was found between the stone volume and ablation speed (r = 0.659, p = 0.000), and a moderate negative correlation was found between the stone volume and laser efficacy (J/mm3) (r = - 0.392, p = 0.000). With increasing volume of the stone, J/mm3 decreased significantly and ablation speed increased significantly (p < 0.001). Complications occurred in 21.05% (16/76) patients, most of which were Clavien grades 1-2. Overall SFR is 96.05%. CONCLUSION: Laser efficiency increases at higher stone volumes (> 1000 mm3), as less energy is required to ablate every mm3 of stone.


Assuntos
Cálculos Renais , Lasers de Estado Sólido , Litotripsia a Laser , Humanos , Túlio , Cálculos Renais/cirurgia , Estudos Prospectivos
2.
Int Urol Nephrol ; 55(6): 1467-1475, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36976419

RESUMO

BACKGROUND: Robotic-assisted laparoscopic prostatectomy (RALP) is the most preferred intervention for the management of prostatic malignancy worldwide. Hem-o-Lok clips (HOLC) are widely used for haemostasis and lateral pedicle ligation. These clips are prone to migrate and lodge at the anastomotic junction as well as inside the bladder causing lower urinary tract symptoms (LUTS) secondary to bladder neck contracture (BNC) or bladder calculi. The objective of this study is to describe the incidence, clinical presentation, management, and outcome of HOLC migration. METHODOLOGY: Retrospective analysis of the database of Post RALP patients who developed LUTS secondary to HOLC migration was done. Cystoscopy findings, number of procedures required, number of HOLC removed intra-operatively, and follow-up of the patients was reviewed. RESULTS: The incidence of HOLC migration requiring intervention was 1.78% (9/505). The mean age of the patient, BMI, Pre-operative Serum PSA were 62.8 years, 27.8 kg/m2, and 9.8 ng/mL, respectively. The mean duration of appearance of symptoms due to HOLC migration was 9 months. Two patients presented with Haematuria and 7 presented with LUTS. Seven patients required a single intervention while 2 required up to 6 procedures for recurrent symptoms secondary to recurrent HOLC migration. CONCLUSION: HOLC use in RALP may present with migration and associated complications. HOLC migration is associated with severe BNC and may require multiple endoscopic interventions. Severe dysuria and LUTS not responding to medical management should be treated using an algorithmic approach and there should be a low threshold for performing cystoscopy and intervention in these cases to improve outcomes.


Assuntos
Migração de Corpo Estranho , Laparoscopia , Sintomas do Trato Urinário Inferior , Procedimentos Cirúrgicos Robóticos , Masculino , Humanos , Pessoa de Meia-Idade , Bexiga Urinária/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Migração de Corpo Estranho/epidemiologia , Migração de Corpo Estranho/etiologia , Prostatectomia/efeitos adversos , Prostatectomia/métodos , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Instrumentos Cirúrgicos/efeitos adversos , Sintomas do Trato Urinário Inferior/cirurgia
3.
Asian J Urol ; 10(1): 64-69, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36721687

RESUMO

Objective: Single-use flexible ureteroscopes (fURSs) have recently been introduced by different companies. Goal of this in-vitro study was to compare four fURSs. Methods: We performed in vitro analysis of Uscope 7.5 Fr and Uscope 9.5 Fr (Pusen Ltd., Zhuhai, China), LithoVue 9.5 Fr (LithoVue™, Boston Scientific, MA, USA), and Indoscope 9.5 Fr (Bioradmedisys™, Pune, India). Optical characteristics (image resolution, color representation, and luminosity) were compared at various distances of 10 mm, 20 mm, and 50 mm. Deflection and irrigation were evaluated with and without accessories. Results: Color perception was comparable for all scopes at 10 mm (p<0.05), while Lithovue 9.5 Fr was comparable with Indoscope 9.5 Fr at the distances of 20 mm and 50 mm. Both scopes were statistically better than both Uscopes at the distances of 20 mm and 50 mm. Image resolution powers were comparable amongst all fURSs at the distances of 10 mm and 20 mm (3.56 line pairs per millimeter [lp/mm]). However, Indoscope (3.56 lp/mm) was superior to LithoVue and Uscope scopes (3.17 lp/mm) at the distance of 50 mm. Luminosity at the distance of 10 mm was comparable for LithoVue and Uscope 9.5 Fr. However, at the distances of 20 mm and 50 mm, LithoVue had the highest luminosity while Uscope 7.5 Fr had the lowest one. Indoscope had lower luminosity than other 9.5 Fr scopes at all distances. With empty working channel and 200 µm laser fiber, Indoscope had the maximum deflection (285°). With basket, Uscope 7.5 Fr had the maximum loss of deflection (30°) while Indoscope had no deflection loss. With empty working channel, all scopes had comparable irrigation flow rates in both deflected and undeflected state. Similarly, with 200 µm laser or basket, irrigation flow rates were comparable in all scopes. Conclusion: Color representation was equivalent for Indoscope and LithoVue, while being better than Uscope 7.5 Fr and Uscope 9.5 Fr. Image resolution was comparable in all scopes at the distances of 10 mm and 20 mm. Beyond the distance of 10 mm, luminosity of LithoVue was the highest and that of Uscope 7.5 Fr was the lowest. Deflection loss was the minimum with Indoscope and the maximum with 7.5 Fr Uscope. Under all scenarios, irrigation flow rates were comparable in all scopes.

4.
Int J Urol ; 29(11): 1362-1367, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36000790

RESUMO

OBJECTIVE: To compare and analyze the results of laparoscopic ureteric reimplantation and robotic-assisted ureteric reimplantation at our tertiary institute. MATERIALS AND METHODS: We retrospectively reviewed data of adult patients who underwent laparoscopic ureteric reimplantation and robotic-assisted ureteric reimplantation between January 2000 and December 2020. Data were analyzed for 19 patients in the laparoscopic group and 47 patients in the robotic group. The data were compared in both the groups. RESULTS: The most common presentation was flank pain (67.89%) followed by recurrent UTI (21.05%) in both the groups. The baseline characteristics and demographic data including age, gender, laterality, Charlson comorbidity index, and BMI were comparable in both the groups. The time range from previous surgeries to presentation varied from 7 days to 5 years. There is statistically significant difference between the operative time in the laparoscopic (224.23 ± 76.61 min) and robotic groups (187.06 ± 52.81 min) (p = 0.027). There is statistically significant difference between the hospital stay also between the two groups (9.07 ± 2.75 vs. 6 ± 1.65 days p-0.001). There were no differences in the complication rate and postoperative outcomes in both the groups. Mean length of follow-up was 28 ± 25.5 (2-108) months and 20.57 ± 19.91 (2-96) months in both the groups, respectively. The success rates in terms of symptomatic improvement, decrease in hydronephrosis, and improved drainage in the laparoscopic and robotic groups were 94.73% and 95.45%, respectively, which were statistically not significant. CONCLUSIONS: Robotic ureteric reimplantation and laparoscopic ureteric reimplantation are comparable in clinical outcomes. Robotic-assisted laparoscopic ureteric reimplantation is feasible, safe, and faster with excellent outcomes, decreased hospital stay, and minimal complications.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Ureter , Adulto , Humanos , Ureter/cirurgia , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Reimplante/efeitos adversos , Reimplante/métodos , Laparoscopia/efeitos adversos , Laparoscopia/métodos
5.
Am J Clin Exp Urol ; 9(3): 202-210, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34327259

RESUMO

OBJECTIVE: The aim of the present study was to develop a nomogram to accurately predict the need for intervention in patients suffering from LUTS due to benign prostatic hyperplasia (BPH) and internally validate it. MATERIAL AND METHODS: The data was collected from the community subjects from the state of Gujarat in western India. All the demographic data, physical examination, PSA, uroflowmetry and prostatic ultrasound was collected in 92 subjects and were followed up after 2 years. The data was analyzed and logistic regression model was used to build a predictive model. A nomogram was build using R software. Nomogram was internally validated using 50 subjects. RESULTS: 92 subjects were analyzed for developing the nomogram. Out of these, 17 patients needed intervention. 8 patients were started on medical therapy and 9 patients were taken up for surgical intervention. Of all the statistically significant predictors, peak flow rate was the most significant and was followed by median lobe enlargement, PSA, prostate volume and IPSS. These variables were used to develop a prediction model for the intervention required using reduced logistic regression model. The predictive accuracy of the model was 95.65% with a sensitivity of 88.28%, a specificity of 97.33%, a positive predictive value (PPV) of 88.24%, and a negative predictive value (NPV) of 97.33%. The AUC of the model was 0.799. Internal validation was done on 50 subjects which had sensitivity, specificity and AUC of the model at 89.66%, 90.48% and 0.968 respectively. CONCLUSION: The study demonstrates the clinical application of nomogram which uses IPSS, PSA, peak flow rate, prostate volume and median lobe enlargement (intravesical prostatic volume). It has a sensitivity of 88.24%, specificity of 97.33%. It predicts the need for intervention in BPH patients with accuracy of 95.65% which was internally validated with an accuracy of 90%.

6.
J Clin Diagn Res ; 9(4): PD09-10, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26023594

RESUMO

Encephalocele is a mesodermal defect in the skull bones and duramater. Parietal encephalocele is a rare congenital anomaly of newborn with variable prognostic value. The authors report a case of a very large inter parietal encephalocele with no associated other system malformations. A midline inter parietal encephalocele is much rare, earlier reported cases were posterior parietal in location. Such cases can be successfully operated upon with a very good outcome. A unique case of a 18 day neonate, with swelling over scalp was evaluated by the neurosurgical team and the patient underwent neurosurgery. In planning the strategy for management of encephalocele, one needs to take into consideration the site, size, contents, patency of CSF pathway, neurological status and other associated anomalies. Inspite of such a big encephalocele in an atypical location, excision and repair gave excellent results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...