1.
IEEE Trans Med Imaging ; 42(3): 823-833, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36322502

RESUMO

We present a meta-learning framework for interactive medical image registration. Our proposed framework comprises three components: a learning-based medical image registration algorithm, a form of user interaction that refines registration at inference, and a meta-learning protocol that learns a rapidly adaptable network initialization. This paper describes a specific algorithm that implements the registration, interaction and meta-learning protocol for our exemplar clinical application: registration of magnetic resonance (MR) imaging to interactively acquired, sparsely-sampled transrectal ultrasound (TRUS) images. Our approach obtains comparable registration error (4.26 mm) to the best-performing non-interactive learning-based 3D-to-3D method (3.97 mm) while requiring only a fraction of the data, and occurring in real-time during acquisition. Applying sparsely sampled data to non-interactive methods yields higher registration errors (6.26 mm), demonstrating the effectiveness of interactive MR-TRUS registration, which may be applied intraoperatively given the real-time nature of the adaptation process.


Assuntos
Imageamento Tridimensional , Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Imageamento Tridimensional/métodos , Ultrassonografia/métodos , Algoritmos , Imageamento por Ressonância Magnética
2.
Med Image Anal ; 78: 102427, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35344824

RESUMO

In this paper, we consider image quality assessment (IQA) as a measure of how images are amenable with respect to a given downstream task, or task amenability. When the task is performed using machine learning algorithms, such as a neural-network-based task predictor for image classification or segmentation, the performance of the task predictor provides an objective estimate of task amenability. In this work, we use an IQA controller to predict the task amenability which, itself being parameterised by neural networks, can be trained simultaneously with the task predictor. We further develop a meta-reinforcement learning framework to improve the adaptability for both IQA controllers and task predictors, such that they can be fine-tuned efficiently on new datasets or meta-tasks. We demonstrate the efficacy of the proposed task-specific, adaptable IQA approach, using two clinical applications for ultrasound-guided prostate intervention and pneumonia detection on X-ray images.


Assuntos
Aprendizado de Máquina , Redes Neurais de Computação , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Ultrassonografia
3.
Med Image Anal ; 74: 102231, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34583240

RESUMO

We present Free Point Transformer (FPT) - a deep neural network architecture for non-rigid point-set registration. Consisting of two modules, a global feature extraction module and a point transformation module, FPT does not assume explicit constraints based on point vicinity, thereby overcoming a common requirement of previous learning-based point-set registration methods. FPT is designed to accept unordered and unstructured point-sets with a variable number of points and uses a "model-free" approach without heuristic constraints. Training FPT is flexible and involves minimizing an intuitive unsupervised loss function, but supervised, semi-supervised, and partially- or weakly-supervised training are also supported. This flexibility makes FPT amenable to multimodal image registration problems where the ground-truth deformations are difficult or impossible to measure. In this paper, we demonstrate the application of FPT to non-rigid registration of prostate magnetic resonance (MR) imaging and sparsely-sampled transrectal ultrasound (TRUS) images. The registration errors were 4.71 mm and 4.81 mm for complete TRUS imaging and sparsely-sampled TRUS imaging, respectively. The results indicate superior accuracy to the alternative rigid and non-rigid registration algorithms tested and substantially lower computation time. The rapid inference possible with FPT makes it particularly suitable for applications where real-time registration is beneficial.


Assuntos
Neoplasias da Próstata , Algoritmos , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Próstata/diagnóstico por imagem , Ultrassonografia
4.
IEEE Trans Biomed Eng ; 67(11): 3234-3241, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32167884

RESUMO

OBJECTIVE: Integrate tracked ultrasound and AI methods to provide a safer and more accessible alternative to X-ray for scoliosis measurement. We propose automatic ultrasound segmentation for 3-dimensional spine visualization and scoliosis measurement to address difficulties in using ultrasound for spine imaging. METHODS: We trained a convolutional neural network for spine segmentation on ultrasound scans using data from eight healthy adult volunteers. We tested the trained network on eight pediatric patients. We evaluated image segmentation and 3-dimensional volume reconstruction for scoliosis measurement. RESULTS: As expected, fuzzy segmentation metrics reduced when trained networks were translated from healthy volunteers to patients. Recall decreased from 0.72 to 0.64 (8.2% decrease), and precision from 0.31 to 0.27 (3.7% decrease). However, after finding optimal thresholds for prediction maps, binary segmentation metrics performed better on patient data. Recall decreased from 0.98 to 0.97 (1.6% decrease), and precision from 0.10 to 0.06 (4.5% decrease). Segmentation prediction maps were reconstructed to 3-dimensional volumes and scoliosis was measured in all patients. Measurement in these reconstructions took less than 1 minute and had a maximum error of 2.2° compared to X-ray. CONCLUSION: automatic spine segmentation makes scoliosis measurement both efficient and accurate in tracked ultrasound scans. SIGNIFICANCE: Automatic segmentation may overcome the limitations of tracked ultrasound that so far prevented its use as an alternative of X-ray in scoliosis measurement.


Assuntos
Escoliose , Criança , Humanos , Imageamento Tridimensional , Redes Neurais de Computação , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...