Resultados 1 - 14 de 14
Filtrar
1.
IEEE Trans Med Imaging ; 33(5): 1119-28, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24770916

RESUMO

The purpose of this study was to increase the sensitivity of XFCT imaging by optimizing the data acquisition geometry for reduced scatter X-rays. The placement of detectors and detector energy window were chosen to minimize scatter X-rays. We performed both theoretical calculations and Monte Carlo simulations of this optimized detector configuration on a mouse-sized phantom containing various gold concentrations. The sensitivity limits were determined for three different X-ray spectra: a monoenergetic source, a Gaussian source, and a conventional X-ray tube source. Scatter X-rays were minimized using a backscatter detector orientation (scatter direction > 110(°) to the primary X-ray beam). The optimized configuration simultaneously reduced the number of detectors and improved the image signal-to-noise ratio. The sensitivity of the optimized configuration was 10 µg/mL (10 pM) at 2 mGy dose with the mono-energetic source, which is an order of magnitude improvement over the unoptimized configuration (102 pM without the optimization). Similar improvements were seen with the Gaussian spectrum source and conventional X-ray tube source. The optimization improvements were predicted in the theoretical model and also demonstrated in simulations. The sensitivity of XFCT imaging can be enhanced by an order of magnitude with the data acquisition optimization, greatly enhancing the potential of this modality for future use in clinical molecular imaging.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Espectrometria por Raios X/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Animais , Simulação por Computador , Camundongos , Modelos Biológicos , Imagens de Fantasmas , Razão Sinal-Ruído
2.
Med Phys ; 41(1): 011710, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24387502

RESUMO

PURPOSE: Small animal radiation therapy has advanced significantly in recent years. Whereas in the past dose was delivered using a single beam and a lead shield for sparing of healthy tissue, conformal doses can be now delivered using more complex dedicated small animal radiotherapy systems with image guidance. The goal of this paper is to investigate dose distributions for three small animal radiation treatment modalities. METHODS: This paper presents a comparison of dose distributions generated by the three approaches-a single-field irradiator with a 200 kV beam and no image guidance, a small animal image-guided conformal system based on a modified microCT scanner with a 120 kV beam developed at Stanford University, and a dedicated conformal system, SARRP, using a 220 kV beam developed at Johns Hopkins University. The authors present a comparison of treatment plans for the three modalities using two cases: a mouse with a subcutaneous tumor and a mouse with a spontaneous lung tumor. A 5 Gy target dose was calculated using the EGSnrc Monte Carlo codes. RESULTS: All treatment modalities generated similar dose distributions for the subcutaneous tumor case, with the highest mean dose to the ipsilateral lung and bones in the single-field plan (0.4 and 0.4 Gy) compared to the microCT (0.1 and 0.2 Gy) and SARRP (0.1 and 0.3 Gy) plans. The lung case demonstrated that due to the nine-beam arrangements in the conformal plans, the mean doses to the ipsilateral lung, spinal cord, and bones were significantly lower in the microCT plan (2.0, 0.4, and 1.9 Gy) and the SARRP plan (1.5, 0.5, and 1.8 Gy) than in single-field irradiator plan (4.5, 3.8, and 3.3 Gy). Similarly, the mean doses to the contralateral lung and the heart were lowest in the microCT plan (1.5 and 2.0 Gy), followed by the SARRP plan (1.7 and 2.2 Gy), and they were highest in the single-field plan (2.5 and 2.4 Gy). For both cases, dose uniformity was greatest in the single-field irradiator plan followed by the SARRP plan due to the sensitivity of the lower energy microCT beam to target heterogeneities and image noise. CONCLUSIONS: The two treatment planning examples demonstrate that modern small animal radiotherapy techniques employing image guidance, variable collimation, and multiple beam angles deliver superior dose distributions to small animal tumors as compared to conventional treatments using a single-field irradiator. For deep-seated mouse tumors, however, higher-energy conformal radiotherapy could result in higher doses to critical organs compared to lower-energy conformal radiotherapy. Treatment planning optimization for small animal radiotherapy should therefore be developed to take full advantage of the novel conformal systems.


Assuntos
Método de Monte Carlo , Radioterapia Conformacional/métodos , Animais , Camundongos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Fatores de Tempo
3.
Phys Med Biol ; 59(1): 219-32, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24334507

RESUMO

X-ray fluorescence computed tomography (XFCT) imaging has been focused on the detection of K-shell x-rays. The potential utility of L-shell x-ray XFCT is, however, not well studied. Here we report the first Monte Carlo (MC) simulation of preclinical L-shell XFCT imaging of Cisplatin. We built MC models for both L- and K-shell XFCT with different excitation energies (15 and 30 keV for L-shell and 80 keV for K-shell XFCT). Two small-animal sized imaging phantoms of 2 and 4 cm diameter containing a series of objects of 0.6 to 2.7 mm in diameter at 0.7 to 16 mm depths with 10 to 250 µg mL(-1) concentrations of Pt are used in the study. Transmitted and scattered x-rays were collected with photon-integrating transmission detector and photon-counting detector arc, respectively. Collected data were rearranged into XFCT and transmission CT sinograms for image reconstruction. XFCT images were reconstructed with filtered back-projection and with iterative maximum-likelihood expectation maximization without and with attenuation correction. While K-shell XFCT was capable of providing an accurate measurement of Cisplatin concentration, its sensitivity was 4.4 and 3.0 times lower than that of L-shell XFCT with 15 keV excitation beam for the 2 cm and 4 cm diameter phantom, respectively. With the inclusion of excitation and fluorescence beam attenuation correction, we found that L-shell XFCT was capable of providing fairly accurate information of Cisplatin concentration distribution. With a dose of 29 and 58 mGy, clinically relevant Cisplatin Pt concentrations of 10 µg mg(-1) could be imaged with L-shell XFCT inside a 2 cm and 4 cm diameter object, respectively.


Assuntos
Cisplatino , Tomografia Óptica/métodos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Razão Sinal-Ruído , Raios X
4.
Med Phys ; 40(3): 030701, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23464279

RESUMO

PURPOSE: Developing an imaging method to directly monitor the spatial distribution of platinum-based (Pt) drugs at the tumor region is of critical importance for early assessment of treatment efficacy and personalized treatment. In this study, the authors investigated the feasibility of imaging platinum (Pt)-based drug distribution using x-ray fluorescence (XRF, a.k.a. characteristic x ray) CT (XFCT). METHODS: A 5-mm-diameter pencil beam produced by a polychromatic x-ray source equipped with a tungsten anode was used to stimulate emission of XRF photons from Pt drug embedded within a water phantom. The phantom was translated and rotated relative to the stationary pencil beam in a first-generation CT geometry. The x-ray energy spectrum was collected for 18 s at each position using a cadmium telluride detector. The spectra were then used for the K-shell XRF peak isolation and sinogram generation for Pt. The distribution and concentration of Pt were reconstructed with an iterative maximum likelihood expectation maximization algorithm. The capability of XFCT to multiplexed imaging of Pt, gadolinium (Gd), and iodine (I) within a water phantom was also investigated. RESULTS: Measured XRF spectrum showed a sharp peak characteristic of Pt with a narrow full-width at half-maximum (FWHM) (FWHMKα1 = 1.138 keV, FWHMKα2 = 1.052 keV). The distribution of Pt drug in the water phantom was clearly identifiable on the reconstructed XRF images. Our results showed a linear relationship between the XRF intensity of Pt and its concentrations (R(2) = 0.995), suggesting that XFCT is capable of quantitative imaging. A transmission CT image was also obtained to show the potential of the approach for providing attenuation correction and morphological information. Finally, the distribution of Pt, Gd, and I in the water phantom was clearly identifiable in the reconstructed images from XFCT multiplexed imaging. CONCLUSIONS: XFCT is a promising modality for monitoring the spatial distribution of Pt drugs. The technique may be useful in tailoring tumor treatment regimen in the future.


Assuntos
Antineoplásicos/metabolismo , Imagens de Fantasmas , Platina/metabolismo , Tomografia Computadorizada por Raios X/instrumentação , Transporte Biológico , Estudos de Viabilidade , Processamento de Imagem Assistida por Computador , Espectrometria por Raios X
5.
IEEE Trans Med Imaging ; 32(2): 262-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-23076031

RESUMO

Simultaneous imaging of multiple probes or biomarkers represents a critical step toward high specificity molecular imaging. In this work, we propose to utilize the element-specific nature of the X-ray fluorescence (XRF) signal for imaging multiple elements simultaneously (multiplexing) using XRF computed tomography (XFCT). A 5-mm-diameter pencil beam produced by a polychromatic X-ray source (150 kV, 20 mA) was used to stimulate emission of XRF photons from 2% (weight/volume) gold (Au), gadolinium (Gd), and barium (Ba) embedded within a water phantom. The phantom was translated and rotated relative to the stationary pencil beam in a first-generation CT geometry. The X-ray energy spectrum was collected for 18 s at each position using a cadmium telluride detector. The spectra were then used to isolate the K shell XRF peak and to generate sinograms for the three elements of interest. The distribution and concentration of the three elements were reconstructed with the iterative maximum likelihood expectation maximization algorithm. The linearity between the XFCT intensity and the concentrations of elements of interest was investigated. We found that measured XRF spectra showed sharp peaks characteristic of Au, Gd, and Ba. The narrow full-width at half-maximum (FWHM) of the peaks strongly supports the potential of XFCT for multiplexed imaging of Au, Gd, and Ba ( FWHM(Au,Kα1) = 0.619 keV, FWHM(Au,Kα2)=1.371 keV , FWHM(Gd,Kα)=1.297 keV, FWHM(Gd,Kß)=0.974 keV , FWHM(Ba,Kα)=0.852 keV, and FWHM(Ba,Kß)=0.594 keV ). The distribution of Au, Gd, and Ba in the water phantom was clearly identifiable in the reconstructed XRF images. Our results showed linear relationships between the XRF intensity of each tested element and their concentrations ( R(2)(Au)=0.944 , R(Gd)(2)=0.986, and R(Ba)(2)=0.999), suggesting that XFCT is capable of quantitative imaging. Finally, a transmission CT image was obtained to show the potential of the approach for providing attenuation correction and morphological information. In conclusion, XFCT is a promising modality for multiplexed imaging of high atomic number probes.


Assuntos
Interpretação de Imagem Radiográfica Assistida por Computador/instrumentação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Espectrometria por Raios X/instrumentação , Espectrometria por Raios X/métodos , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Imagens de Fantasmas , Projetos Piloto , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
IEEE Trans Med Imaging ; 31(8): 1620-7, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22692896

RESUMO

This work provides a comprehensive Monte Carlo study of X-ray fluorescence computed tomography (XFCT) and K-edge imaging system, including the system design, the influence of various imaging components, the sensitivity and resolution under various conditions. We modified the widely used EGSnrc/DOSXYZnrc code to simulate XFCT images of two acrylic phantoms loaded with various concentrations of gold nanoparticles and Cisplatin for a number of XFCT geometries. In particular, reconstructed signal as a function of the width of the detector ring, its angular coverage and energy resolution were studied. We found that XFCT imaging sensitivity of the modeled systems consisting of a conventional X-ray tube and a full 2-cm-wide energy-resolving detector ring was 0.061% and 0.042% for gold nanoparticles and Cisplatin, respectively, for a dose of ∼ 10 cGy. Contrast-to-noise ratio (CNR) of XFCT images of the simulated acrylic phantoms was higher than that of transmission K-edge images for contrast concentrations below 0.4%.


Assuntos
Imagem Molecular/instrumentação , Imagem Molecular/métodos , Espectrometria por Raios X/métodos , Tomografia Computadorizada por Raios X/métodos , Cisplatino/química , Simulação por Computador , Ouro/química , Processamento de Imagem Assistida por Computador , Nanopartículas Metálicas/química , Método de Monte Carlo , Imagens de Fantasmas , Razão Sinal-Ruído
7.
Med Phys ; 38(6): 3039-49, 2011 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-21815377

RESUMO

PURPOSE: The aim of this work was to evaluate the effect of tissue segmentation on the accuracy of Monte Carlo (MC) dose calculations for kilovoltage radiation therapy, which are commonly used in preclinical radiotherapy studies and are also being revisited as a clinical treatment modality. The feasibility of tissue segmentation routinely done on the basis of differences in tissue mass densities was studied and a new segmentation scheme based on differences in effective atomic numbers was developed. METHODS: MC dose calculations in a cylindrical mouse phantom with small cylindrical inhomogeneities consisting of 34 ICRU-44 tissues were performed using the EGSnrc/BEAMnrc and DOSXYZnrc codes. The dose to tissue was calculated for five different kilovoltage beams currently used in small animal radiotherapy: a microCT 120 kV beam, two 225 kV beams filtered with either 4 mm of Al or 0.5 mm of Cu, a heavily filtered 320 kV beam, and a 192Ir beam. The mean doses to the 34 ICRU-44 tissues as a function of tissue mass density and effective atomic number and beam energy were studied. A treatment plan for an orthotopic lung tumor model was created, and the dose distribution was calculated for three tissue segmentation schemes using 4, 8, and 39 tissue bins to assess the significance of the simulation results for kilovoltage radiotherapy. RESULTS: In our model, incorrect assignment of adipose tissue to muscle caused dose calculation differences of 27%, 13%, and 7% for the 120 kV beam and the 225 kV beams filtered with 4 mm Al and 0.5 mm Cu, respectively. For the heavily filtered 320 kV beam and a 192Ir source, potential dose calculation differences due to tissue mis-assignment were below 4%. There was no clear relationship between the dose to tissue and its mass density for x-ray beams generated by tube potentials equal or less than 225 kV. A second order polynomial fit approximated well the absorbed dose to tissue as a function of effective atomic number for these beams. In the mouse study, the 120 kV beam dose to bone was overestimated by 100% and underestimated by 10% for the 4 and 8-tissue segmentation schemes compared to the 39-tissue segmentation scheme, respectively. Dose to adipose tissue was overestimated by 30% and underestimated by 10%, respectively. In general, organ at risk (OAR) doses were overestimated in the 4-tissue and the 8-tissue segmentation schemes compared to the 39-tissue segmentation. CONCLUSIONS: Tissue segmentation was shown to be a key parameter for dose calculations with kilovoltage beams used in small animal radiotherapy when an x-ray tube with a potential < or = 225 kV is used as a source. A new tissue segmentation scheme with 39 tissues based on effective number differences derived from mass density differences has been implemented.


Assuntos
Doses de Radiação , Radioterapia/métodos , Animais , Radioisótopos de Irídio/uso terapêutico , Camundongos , Método de Monte Carlo , Dosagem Radioterapêutica
8.
Med Phys ; 37(2): 590-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20229867

RESUMO

PURPOSE: Methods used for small animal radiation treatment have yet to achieve the same dose targeting as in clinical radiation therapy. Toward understanding how to better plan small animal radiation using a system recently developed for this purpose, the authors characterized dose distributions produced from conformal radiotherapy of small animals in a microCT scanner equipped with a variable-aperture collimator. METHODS: Dose distributions delivered to a cylindrical solid water phantom were simulated using a Monte Carlo algorithm. Phase-space files for 120 kVp x-ray beams and collimator widths of 1-10 mm at isocenter were generated using BEAMnrc software, and dose distributions for evenly spaced beams numbered from 5 to 80 were generated in DOSXYZnrc for a variety of targets, including centered spherical targets in a range of sizes, spherical targets offset from centered by various distances, and various ellipsoidal targets. Dose distributions were analyzed using dose volume histograms. The dose delivered to a mouse bearing a spontaneous lung tumor was also simulated, and dose volume histograms were generated for the tumor, heart, left lung, right lung, and spinal cord. RESULTS: Results indicated that for centered, symmetric targets, the number of beams required to achieve a smooth dose volume histogram decreased with increased target size. Dose distributions for noncentered, symmetric targets did not exhibit any significant loss of conformality with increasing offset from the phantom center, indicating sufficient beam penetration through the phantom for targeting superficial targets from all angles. Even with variable collimator widths, targeting of asymmetric targets was found to have less conformality than that of spherical targets. Irradiation of a mouse lung tumor with multiple beam widths was found to effectively deliver dose to the tumor volume while minimizing dose to other critical structures. CONCLUSIONS: Overall, this method of generating and analyzing dose distributions provides a quantitative method for developing practical guidelines for small animal radiotherapy treatment planning. Future work should address methods to improve conformality in asymmetric targets.


Assuntos
Radiometria/métodos , Radiometria/veterinária , Planejamento da Radioterapia Assistida por Computador/métodos , Planejamento da Radioterapia Assistida por Computador/veterinária , Radioterapia Conformacional/métodos , Radioterapia Conformacional/veterinária , Animais , Simulação por Computador , Relação Dose-Resposta à Radiação , Camundongos , Modelos Biológicos , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade
9.
Med Phys ; 36(11): 4991-9, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19994508

RESUMO

PURPOSE: Small animal conformal radiotherapy (RT) is essential for preclinical cancer research studies and therefore various microRT systems have been recently designed. The aim of this paper is to efficiently calculate the dose delivered using our microRT system based on a microCT scanner with the Monte Carlo (MC) method and to compare the MC calculations to film measurements. METHODS: Doses from 2-30 mm diameter 120 kVp photon beams deposited in a solid water phantom with 0.2 x 0.2 x 0.2 mm3 voxels are calculated using the latest versions of the EGSnrc codes BEAMNRC and DOSXYZNRC. Two dose calculation approaches are studied: a two-step approach using phase-space files and direct dose calculation with BEAMNRC simulation sources. Due to the small beam size and submillimeter voxel size resulting in long calculation times, variance reduction techniques are studied. The optimum bremsstrahlung splitting number (NBRSPL in BEAMNRC) and the optimum DOSXYZNRC photon splitting (Nsplit) number are examined for both calculation approaches and various beam sizes. The dose calculation efficiencies and the required number of histories to achieve 1% statistical uncertainty--with no particle recycling--are evaluated for 2-30 mm beams. As a final step, film dose measurements are compared to MC calculated dose distributions. RESULTS: The optimum NBRSPL is approximately 1 x 10(6) for both dose calculation approaches. For the dose calculations with phase-space files, Nsplit varies only slightly for 2-30 mm beams and is established to be 300. Nsplit for the DOSXYZNRC calculation with the BEAMNRC source ranges from 300 for the 30 mm beam to 4000 for the 2 mm beam. The calculation time significantly increases for small beam sizes when the BEAMNRC simulation source is used compared to the simulations with phase-space files. For the 2 and 30 mm beams, the dose calculations with phase-space files are more efficient than the dose calculations with BEAMNRC sources by factors of 54 and 1.6, respectively. The dose calculation efficiencies converge for beams with diameters larger than 30 mm. CONCLUSIONS: A very good agreement of MC calculated dose distributions to film measurements is found. The mean difference of percentage depth dose curves between calculated and measured data for 2, 5, 10, and 20 mm beams is 1.8%.


Assuntos
Método de Monte Carlo , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Animais , Simulação por Computador , Dosimetria Fotográfica , Imagens de Fantasmas , Fótons/uso terapêutico , Radiometria/métodos , Dosagem Radioterapêutica , Software , Fatores de Tempo , Água , Microtomografia por Raio-X/métodos
10.
Phys Med Biol ; 53(9): 2439-56, 2008 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-18421124

RESUMO

Monte Carlo (MC) dose calculations are performed on patient geometries derived from computed tomography (CT) images. For most available MC codes, the Hounsfield units (HU) in each voxel of a CT image have to be converted into mass density (rho) and material type. This is typically done with a (HU; rho) calibration curve which may lead to mis-assignment of media. In this work, an improved material segmentation using dual-energy CT-based material extraction is presented. For this purpose, the differences in extracted effective atomic numbers Z and the relative electron densities rho(e) of each voxel are used. Dual-energy CT material extraction based on parametrization of the linear attenuation coefficient for 17 tissue-equivalent inserts inside a solid water phantom was done. Scans of the phantom were acquired at 100 kVp and 140 kVp from which Z and rho(e) values of each insert were derived. The mean errors on Z and rho(e) extraction were 2.8% and 1.8%, respectively. Phantom dose calculations were performed for 250 kVp and 18 MV photon beams and an 18 MeV electron beam in the EGSnrc/DOSXYZnrc code. Two material assignments were used: the conventional (HU; rho) and the novel (HU; rho, Z) dual-energy CT tissue segmentation. The dose calculation errors using the conventional tissue segmentation were as high as 17% in a mis-assigned soft bone tissue-equivalent material for the 250 kVp photon beam. Similarly, the errors for the 18 MeV electron beam and the 18 MV photon beam were up to 6% and 3% in some mis-assigned media. The assignment of all tissue-equivalent inserts was accurate using the novel dual-energy CT material assignment. As a result, the dose calculation errors were below 1% in all beam arrangements. Comparable improvement in dose calculation accuracy is expected for human tissues. The dual-energy tissue segmentation offers a significantly higher accuracy compared to the conventional single-energy segmentation.


Assuntos
Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Calibragem , Elétrons , Humanos , Processamento de Imagem Assistida por Computador , Modelos Estatísticos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Radiometria/instrumentação , Reprodutibilidade dos Testes , Software , Tomógrafos Computadorizados
11.
Phys Med Biol ; 53(1): 61-75, 2008 Jan 07.
Artigo em Inglês | MEDLINE | ID: mdl-18182687

RESUMO

The Axxent developed by Xoft Inc. is a novel electronic brachytherapy system capable of generating x-rays up to 50 keV. These low energy photon-emitting sources merit attention not only because of their ability to vary the dosimetric properties of the radiation, but also because of the radiobiological effects of low energy x-rays. The objective of this study is to characterize the x-ray source and to model it using the Geant4 Monte Carlo code. Spectral and attenuation curve measurements are performed at various peak voltages and angles and the source is characterized in terms of spectrum and half-value layers (HVLs). Also, the effects of source variation and source aging are quantified. Bremsstrahlung splitting, phase-space scoring and particle-tagging features are implemented in the Geant4 code, which is bench-marked against BEAMnrc simulations. HVLs from spectral measurements, attenuation curve measurements and Geant4 simulations mostly agree within uncertainty. However, there are discrepancies between measurements and simulations for photons emitted on the source transverse plane (90 degrees).


Assuntos
Braquiterapia/instrumentação , Análise Espectral/instrumentação , Fenômenos Biofísicos , Biofísica , Braquiterapia/estatística & dados numéricos , Simulação por Computador , Eletrônica Médica/instrumentação , Eletrônica Médica/estatística & dados numéricos , Humanos , Método de Monte Carlo , Neoplasias/radioterapia , Imagens de Fantasmas , Fótons/uso terapêutico , Planejamento da Radioterapia Assistida por Computador , Sensibilidade e Especificidade , Análise Espectral/estatística & dados numéricos , Raios X
12.
Radiother Oncol ; 86(1): 93-8, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18068841

RESUMO

PURPOSE: Tissue segmentation is an important step in Monte Carlo (MC) dose calculation and is often done uncritically. A new approach to tissue segmentation using dual-energy CT images is studied in this work. MATERIALS AND METHODS: A simple MC model of a CT scanner was built and CT images of phantoms with ten tissue-equivalent cylinders were simulated using soft and hard X-ray spectra. The Z and rho(e) of the cylinders were extracted using a formalism based on a parameterization of the linear attenuation coefficient. RESULTS: It was shown that in order to extract Z and rho(e) with a reasonable accuracy, hard X-ray beams have to be used for scanning. When an additional filtration of 9 mm of aluminium in the CT X-ray beam is used, beam hardening in high density materials is suppressed and the mean errors of the extraction of Z and rho(e) for 10 tissue-equivalent materials in a small tissue-equivalent phantom are 3.7% and 3.1%, respectively. CONCLUSIONS: MC simulations were used to show that the extraction of Z and rho(e) for a number of tissue-equivalent materials using dual-energy CT images is possible which improves tissue segmentation for Monte Carlo dose calculations, as demonstrated with a 250 kVp photon beam dose calculation.


Assuntos
Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X , Algoritmos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica
13.
Phys Med Biol ; 52(19): 5945-55, 2007 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-17881811

RESUMO

The dose delivered to patients during computed tomography (CT) exams has increased in the past decade. With the increasing complexity of CT examinations, measurement of the dose becomes more difficult and more important. In some cases, the standard methods, such as measurement of the computed tomography dose index (CTDI), are currently under question. One approach to determine the dose from CT exams is to use Monte Carlo (MC) methods. Since the patient geometry can be included in the model, Monte Carlo simulations are potentially the most accurate method of determining the dose delivered to patients. In this work, we developed a MC model of a CT x-ray tube. The model was validated with half-value layer (HVL) measurements and spectral measurements with a high resolution Schottky CdTe spectrometer. First and second HVL for beams without additional filtration calculated from the MC modelled spectra and determined from attenuation measurements differ by less than 2.5%. The differences between the first and second HVL for both filtered and non-filtered beams calculated from the MC modelled spectra and spectral measurements with the CdTe detector were less than 1.8%. The MC modelled spectra match the directly measured spectra. This works presents a first step towards an accurate MC model of a CT scanner.


Assuntos
Desenho Assistido por Computador , Análise de Falha de Equipamento/métodos , Modelos Biológicos , Modelos Teóricos , Radiografia/instrumentação , Radiometria/métodos , Medição de Risco/métodos , Carga Corporal (Radioterapia) , Simulação por Computador , Desenho de Equipamento , Humanos , Método de Monte Carlo , Doses de Radiação , Proteção Radiológica/métodos , Fatores de Risco , Espalhamento de Radiação
14.
Med Phys ; 34(6): 2119-32, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17654915

RESUMO

Computed tomography (CT) images of patients having metallic implants or dental fillings exhibit severe streaking artifacts. These artifacts may disallow tumor and organ delineation and compromise dose calculation outcomes in radiotherapy. We used a sinogram interpolation metal streaking artifact correction algorithm on several phantoms of exact-known compositions and on a prostate patient with two hip prostheses. We compared original CT images and artifact-corrected images of both. To evaluate the effect of the artifact correction on dose calculations, we performed Monte Carlo dose calculation in the EGSnrc/DOSXYZnrc code. For the phantoms, we performed calculations in the exact geometry, in the original CT geometry and in the artifact-corrected geometry for photon and electron beams. The maximum errors in 6 MV photon beam dose calculation were found to exceed 25% in original CT images when the standard DOSXYZnrc/CTCREATE calibration is used but less than 2% in artifact-corrected images when an extended calibration is used. The extended calibration includes an extra calibration point for a metal. The patient dose volume histograms of a hypothetical target irradiated by five 18 MV photon beams in a hypothetical treatment differ significantly in the original CT geometry and in the artifact-corrected geometry. This was found to be mostly due to miss-assignment of tissue voxels to air due to metal artifacts. We also developed a simple Monte Carlo model for a CT scanner and we simulated the contribution of scatter and beam hardening to metal streaking artifacts. We found that whereas beam hardening has a minor effect on metal artifacts, scatter is an important cause of these artifacts.


Assuntos
Algoritmos , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Conformacional/métodos , Tomografia Computadorizada por Raios X/métodos , Simulação por Computador , Modelos Biológicos , Método de Monte Carlo , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/instrumentação