Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 19 de 19
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Sensors (Basel) ; 19(2)2019 Jan 21.
Artigo em Inglês | MEDLINE | ID: mdl-30669626

RESUMO

Molecular biomarkers are very important in biology, biotechnology and even in medicine, but it is quite hard to convert biology-related signals into measurable data. For this purpose, amperometric biosensors have proven to be particularly suitable because of their specificity and sensitivity. The operation and shelf stability of the biosensor are quite important features, and storage procedures therefore play an important role in preserving the performance of the biosensors. In the present study two different designs for both glucose and lactate biosensor, differing only in regards to the containment net, represented by polyurethane or glutharaldehyde, were studied under different storage conditions (+4, -20 and -80 °C) and monitored over a period of 120 days, in order to evaluate the variations of kinetic parameters, as VMAX and KM, and LRS as the analytical parameter. Surprisingly, the storage at -80 °C yielded the best results because of an unexpected and, most of all, long-lasting increase of VMAX and LRS, denoting an interesting improvement in enzyme performances and stability over time. The present study aimed to also evaluate the impact of a short-period storage in dry ice on biosensor performances, in order to simulate a hypothetical preparation-conservation-shipment condition.


Assuntos
Técnicas Biossensoriais/métodos , Temperatura Baixa , Glucose/análise , Ácido Láctico/análise , Preservação Biológica , Gelo-Seco , Desenho de Equipamento , Cinética , Fatores de Tempo
2.
Alcohol ; 63: 61-73, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28847383

RESUMO

The oxidative metabolism of ethanol into acetaldehyde involves several enzymes, including alcohol dehydrogenase (ADH) and catalase-hydrogen peroxide (H2O2). In this regard, while it is well known that 4-methylpyrazole (4-MP) acts by inhibiting ADH in the liver, little attention has been placed on its ability to interfere with fatty acid oxidation-mediated generation of H2O2, a mechanism that may indirectly affect catalase whose enzymatic activity requires H2O2. The aim of our investigation was twofold: 1) to evaluate the effect of systemic (i.p. [intraperitoneal]) and local (into the posterior ventral tegmental area, pVTA) administration of 4-MP on oral ethanol self-administration, and 2) to assess ex vivo whether or not systemic 4-MP affects liver and brain H2O2 availability. The results show that systemic 4-MP reduced ethanol but not acetaldehyde or saccharin self-administration, and decreased the ethanol deprivation effect. Moreover, local intra-pVTA administration of 4-MP reduced ethanol but not saccharin self-administration. In addition, although unable to affect basal catalase activity, systemic administration of 4-MP decreased H2O2 availability both in liver and in brain. Overall, these results indicate that 4-MP interferes with ethanol self-administration and suggest that its behavioral effects could be due to a decline in catalase-H2O2 system activity as a result of a reduction of H2O2 availability, thus highlighting the role of central catalase-mediated metabolism of ethanol and further supporting the key role of acetaldehyde in the reinforcing properties of ethanol.


Assuntos
Antídotos/administração & dosagem , Catalase/metabolismo , Etanol/administração & dosagem , Pirazóis/administração & dosagem , Área Tegmentar Ventral/efeitos dos fármacos , Área Tegmentar Ventral/enzimologia , Animais , Catalase/antagonistas & inibidores , Condicionamento Operante/efeitos dos fármacos , Condicionamento Operante/fisiologia , Fomepizol , Peróxido de Hidrogênio/antagonistas & inibidores , Peróxido de Hidrogênio/metabolismo , Injeções Intraventriculares , Masculino , Ratos , Ratos Wistar , Autoadministração
3.
J Agric Food Chem ; 65(8): 1829-1835, 2017 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-28190357

RESUMO

The amount and composition of the phenolic components play a major role in determining the quality of olive oil. The traditional liquid-liquid extraction (LLE) method requires a time-consuming sample preparation to obtain the "phenolic profile" of extra virgin olive oil (EVOO). This study aimed to develop a microdialysis extraction (MDE) as an alternative to the LLE method to evaluate the phenolic components of EVOO. To this purpose, a microdialysis device and dialysis procedure were developed. "Dynamic-oil" microdialysis was performed using an extracting solution (80:20 methanol/water) flow rate of 2 µL min-1 and a constant EVOO stream of 4 µL min-1. The results indicated a strong positive correlation between MDE and the LLE method, providing a very similar phenolic profile obtained with traditional LLE. In conclusion, the MDE approach, easier and quicker in comparison to LLE, provided a reliable procedure to determine the phenolic components used as a marker of the quality and traceability of EVOO.


Assuntos
Microdiálise/métodos , Olea/química , Azeite de Oliva/isolamento & purificação , Fenóis/química , Extratos Vegetais/isolamento & purificação , Microdiálise/instrumentação , Azeite de Oliva/química , Fenóis/isolamento & purificação , Extratos Vegetais/química
4.
Biosens Bioelectron ; 88: 159-166, 2017 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-27520503

RESUMO

An integrated device for real-time monitoring of glucose and phenols absorption, that consists of a sensors/biosensors system (SB) and a Caco-2TC7 human intestinal cell culture, is described in this study. The SB is composed of a glucose oxidase-based biosensor, a sentinel platinum sensor, a laccase/tyrosinase-based biosensor and a sentinel carbon sensor, all located in the basolateral compartment (BC) of a cell culture plate. Caco-2TC7 cells, differentiated on culture inserts, separated the apical compartment that simulates the intestinal lumen, from the BC which represented the bloodstream. The system recorded currents relative to glucose (1mM) absorption, obtaining bioavailability values (5.1%) comparable to HPLC analysis (4.8%). Phloridzin and phloretin, specific phenolic inhibitors of SGLT1 and GLUT2 glucose transporters, reduced the glucose transport of almost 10 times. They were minimally absorbed in the BC with a bioavailability of 0.13% and 0.49% respectively. The hypoglycemic potential of blueberry and pomegranate juices was also studied. In particular, the amount of glucose absorbed through the Caco-2TC7 monolayer was 8‰ for pomegranate and 1.7‰ for blueberry, demonstrating the potential hypoglycemic effect of the juices. Polyphenols absorption was also monitored by the SB and an increase was recorded during the first 50min in presence of both blueberry and pomegranate juices, then a constant decrease occurred. The proposed device has been developed as innovative tool for the dynamic monitoring of natural compounds effects on glucose absorption, in order to manage postprandial hyperglycemia.


Assuntos
Técnicas Biossensoriais/instrumentação , Glucose/metabolismo , Hipoglicemiantes/farmacologia , Absorção Intestinal , Fenóis/metabolismo , Floretina/farmacologia , Florizina/farmacologia , Mirtilos Azuis (Planta)/química , Linhagem Celular , Desenho de Equipamento , Sucos de Frutas e Vegetais/análise , Humanos , Hiperglicemia/tratamento farmacológico , Hiperglicemia/metabolismo , Hipoglicemiantes/química , Absorção Intestinal/efeitos dos fármacos , Lythraceae/química , Floretina/química , Florizina/química , Telemetria/instrumentação
5.
Biosens Bioelectron ; 67: 214-23, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25155059

RESUMO

Four fullerenes- or nanotubes-modified graphite sensor-biosensor systems (SBs), coupled with a dual-channel telemetric device, based on an ascorbate oxidase (AOx) biosensor, were developed for on line simultaneous amperometric detection of ascorbic acid (AA) and antioxidant capacity in blueberry, kiwi and orange juice. Fullerene C60 (FC60), fullerene C70 (FC70), single-walled carbon nanotubes (SWCN) and multi-walled carbon nanotubes (MWCN) increased the sensitivity of graphite toward AA and phenols 1.2, 1.5, 5.1 and 5.1 times respectively. Fullerenes combined with AOx improved the selectivity toward AA more than nanotubes, being able to hold a higher number of AOx molecules on the biosensor surface. The SBs work at an applied potential of +500 mV, in a concentration range between the LOD and 20 µM, with a response time of two minutes. The LOD is 0.10, 0.13, 0.20 and 0.22 µM for SBs modified with FC60, FC70, SWCN and MWCN respectively. Biosensors register lower AA currents than the sensors due to the enzyme capability to oxidize AA before it reaches the transductor surface. Phenols currents registered by sensors and biosensors did not differ. Based on the difference between sensor and biosensor recorded currents a AA selectivity index was developed as an indicator of specificity toward AA and of the capacity to distinguish between AA and phenols contribution to the antioxidant capacity. This value is almost zero for fullerene-modified SBs, 0.13 and 0.22 for SWCN- and MWCN-modified SBs respectively. The results of juices analysis performed with SBs were in accordance with reference methods.


Assuntos
Antioxidantes/análise , Ácido Ascórbico/análise , Bebidas/análise , Técnicas Biossensoriais/instrumentação , Frutas/química , Fulerenos/química , Misturas Complexas/análise , Condutometria/instrumentação , Eletrodos , Desenho de Equipamento , Análise de Falha de Equipamento , Análise de Alimentos/instrumentação , Nanotubos de Carbono/química , Fenóis/análise , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas , Telemetria/instrumentação
6.
Anal Chem ; 86(17): 8727-34, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25088601

RESUMO

A new carbon ascorbate oxidase-based sensor-biosensor system (SB) was coupled to a dual-channel telemetric device for online simultaneous electrochemical detection of ascorbic acid (AA) and antioxidant capacity in Hamlin, Sanguinello, and Moro orange varieties. The electrocatalytic performances of the SB were investigated by cyclic voltammetry and amperometric techniques. The phenol composition of orange juice of each variety, and the cyclic voltammetries of the most represented phenols, were provided. The in vitro calibrations were performed in PBS (pH 5.6), applying a constant potential of +500 mV. A standard mixture of phenols, based on orange juice composition, was used as reference material for studying SB behavior. SB works at an applied potential of +500 mV, in a concentration range comprised between the LOD 0.26 µM and 20 µM. In this concentration range, limiting the data acquisition time to 2 min, the problems of electrode passivation due to phenols polymerization were overcome. AA calibration showed that the biosensor registered statistically lower currents than the sensor since the enzyme oxidized AA before it reached the electrode surface. Standard mixture calibration showed that currents registered by sensor and biosensor did not statistically differ. The difference between sensor and biosensor AA registered currents was used to calculate an AA selectivity index and, consequently, to determine the AA content and the antioxidant capacity in the juices. The novelty of the SB is its ability to distinguish between AA and phenols contribution to antioxidant capacity. The obtained results were in accordance with reference methods.


Assuntos
Antioxidantes/análise , Ascorbato Oxidase/metabolismo , Ácido Ascórbico/análise , Bebidas/análise , Técnicas Biossensoriais/métodos , Tecnologia de Alimentos/instrumentação , Tecnologia de Alimentos/métodos , Ascorbato Oxidase/química , Técnicas Biossensoriais/instrumentação , Técnicas Eletroquímicas , Eletrodos , Enzimas Imobilizadas/química , Enzimas Imobilizadas/metabolismo , Oxirredução , Fenóis/análise , Telemetria/instrumentação
7.
Anal Chem ; 85(21): 10282-8, 2013 Nov 05.
Artigo em Inglês | MEDLINE | ID: mdl-24102201

RESUMO

A new telemetry system for simultaneous detection of extracellular brain glucose and lactate and motion is presented. The device consists of dual-channel, single-supply miniature potentiostat-I/V converter, a microcontroller unit, a signal transmitter, and a miniaturized microvibration sensor. Although based on simple and inexpensive components, the biotelemetry device has been used for accurate transduction of the anodic oxidation currents generated on the surface of implanted glucose and lactate biosensors and animal microvibrations. The device was characterized and validated in vitro before in vivo experiments. The biosensors were implanted in the striatum of freely moving animals and the biotelemetric device was fixed to the animal's head. Physiological and pharmacological stimulations were given in order to induce striatal neural activation and to modify the motor behavior in awake, untethered animals.


Assuntos
Encéfalo/metabolismo , Glucose/metabolismo , Lactatos/metabolismo , Telemetria , Animais , Técnicas Biossensoriais , Masculino , Ratos , Ratos Sprague-Dawley
8.
Brain Res ; 1538: 159-71, 2013 Nov 13.
Artigo em Inglês | MEDLINE | ID: mdl-24080403

RESUMO

The neurotoxin MPTP is known to induce dopamine release and depletion of ATP in the striatum of rats. Therefore, we studied the changes induced by MPTP and pargyline protection both on striatal dopamine release and on extracellular energy metabolites in freely moving rats, using dual asymmetric-flow microdialysis. A dual microdialysis probe was inserted in the right striatum of rats. MPTP (25mg/kg, 15mg/kg, 10mg/kg) was intraperitoneally administered for three consecutive days. MAO-B inhibitor pargyline (15mg/kg) was systemically administered before neurotoxin administration. The first MPTP dose induced an increase in dialysate dopamine and a decrease of DOPAC levels in striatal dialysate. After the first neurotoxin administration, increases in striatal glucose, lactate, pyruvate, lactate/pyruvate (L/P) and lactate/glucose (L/G) ratios were observed. Subsequent MPTP administrations showed a progressive reduction of dopamine, glucose and pyruvate levels with a concomitant further increase in lactate levels and L/P and L/G ratios. At day 1, pargyline pre-treatment attenuated the MPTP-induced changes in all studied analytes. Starting from day 2, pargyline prevented the depletion of dopamine, glucose and pyruvate while reduced the increase of lactate, L/P ratio and L/G ratio. These in vivo results suggest a pargyline neuroprotection role against the MPTP-induced energetic impairment consequent to mitochondrial damage. This neuroprotective effect was confirmed by TH immunostaining of the substantia nigra.


Assuntos
Corpo Estriado/metabolismo , Dopamina/metabolismo , Metabolismo Energético/efeitos dos fármacos , Intoxicação por MPTP/metabolismo , Inibidores da Monoaminoxidase/uso terapêutico , Pargilina/uso terapêutico , Animais , Masculino , Ratos , Ratos Wistar
9.
Sensors (Basel) ; 13(7): 9522-35, 2013 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-23881145

RESUMO

Ethyl alcohol may be considered one of the most widespread central nervous system (CNS) depressants in Western countries. Because of its toxicological and neurobiological implications, the detection of ethanol in brain extracellular fluid (ECF) is of great importance. In a previous study, we described the development and characterization of an implantable biosensor successfully used for the real-time detection of ethanol in the brain of freely-moving rats. The implanted biosensor, integrated in a low-cost telemetry system, was demonstrated to be a reliable device for the short-time monitoring of exogenous ethanol in brain ECF. In this paper we describe a further in-vitro characterization of the above-mentioned biosensor in terms of oxygen, pH and temperature dependence in order to complete its validation. With the aim of enhancing ethanol biosensor performance, different enzyme loadings were investigated in terms of apparent ethanol Michaelis-Menten kinetic parameters, viz. IMAX, KM and linear region slope, as well as ascorbic acid interference shielding. The responses of biosensors were studied over a period of 28 days. The overall findings of the present study confirm the original biosensor configuration to be the best of those investigated for in-vivo applications up to one week after implantation.


Assuntos
Técnicas Biossensoriais/instrumentação , Química Encefálica , Etanol/análise , Modelos Teóricos , Próteses e Implantes , Animais , Técnicas Biossensoriais/métodos , Enzimas/metabolismo , Concentração de Íons de Hidrogênio , Oxigênio , Ratos , Temperatura
10.
Food Chem ; 135(3): 1555-62, 2012 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-22953893

RESUMO

The present paper deals with a novel telemetric device combined with a carbon amperometric sensor system to determine postharvest changes of ascorbic acid (AA) in fresh-cut fruits, without displacing products out of the storage rooms. The investigation was performed on kiwi, pineapple and melon, subjected to minimal processing, packaging, cold storage, and simulated shelf life. Results demonstrated that AA content of fresh-cut fruits of all species declines differently during storage. Cold storage notably reduced the degradation rate of AA in comparison with samples stored at 20°C. The cold-chain interruption resulted in a sharp AA content reduction when the optimal storage condition was not rapidly replaced. Unpredicted results showed a high activity of oxidative enzymes, which prevented AA detection in melon samples. Our sensor system allowed us to demonstrate that both ascorbate peroxidase and ascorbate oxidase affected the oxidative stability and the nutritional quality of fresh cut melon fruits.


Assuntos
Actinidia/química , Ananas/química , Ácido Ascórbico/química , Cucurbitaceae/química , Frutas/química , Telemetria/métodos , Armazenamento de Alimentos , Oxirredução , Telemetria/economia , Telemetria/instrumentação
11.
Anal Chem ; 84(16): 7072-9, 2012 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-22823474

RESUMO

Ethanol is one of the most widespread psychotropic agents in western society. While its psychoactive effects are mainly associated with GABAergic and glutamatergic systems, the positive reinforcing properties of ethanol are related to activation of mesolimbic dopaminergic pathways resulting in a release of dopamine in the nucleus accumbens. Given these neurobiological implications, the detection of ethanol in brain extracellular fluid (ECF) is of great importance. In this study, we describe the development and characterization of an implantable biosensor for the amperometric detection of brain ethanol in real time. Ten different designs were characterized in vitro in terms of Michaelis-Menten kinetics (V(MAX) and K(M)), sensitivity (linear region slope, limit of detection (LOD), and limit of quantification (LOQ)), and electroactive interference blocking. The same parameters were monitored in selected designs up to 28 days after fabrication in order to quantify their stability. Finally, the best performing biosensor design was selected for implantation in the nucleus accumbens and coupled with a previously developed telemetric device for the real-time monitoring of ethanol in freely moving, untethered rats. Ethanol was then administered systemically to animals, either alone or in combination with ranitidine (an alcohol dehydrogenase inhibitor) while the biosensor signal was continuously recorded. The implanted biosensor, integrated in the low-cost telemetry system, was demonstrated to be a reliable device for the short-time monitoring of exogenous ethanol in brain ECF and represents a new generation of analytical tools for studying ethanol toxicokinetics and the effect of drugs on brain ethanol levels.


Assuntos
Técnicas Biossensoriais/instrumentação , Encéfalo/metabolismo , Eletrodos Implantados , Etanol/metabolismo , Movimento , Telemetria/instrumentação , Animais , Encéfalo/efeitos dos fármacos , Eletroquímica , Etanol/administração & dosagem , Etanol/farmacologia , Limite de Detecção , Masculino , Ranitidina/farmacologia , Ratos , Ratos Sprague-Dawley , Fatores de Tempo
12.
Methods Mol Biol ; 846: 355-64, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22367825

RESUMO

Animal models of Parkinson's disease are essential to explore pathophysiological hypotheses and to test new treatment options, including neurotrophic factors. Catecholaminergic neurotoxins used to generate such models are 6-hydroxydopamine and 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine. These neurotoxins predominantly kill dopaminergic neurons through oxidative damage and mitochondrial failure, although 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine fails to induce a significant dopaminergic neurodegeneration in rats. The present chapter describes a protocol for the 6-hydroxydopamine rat model based on stereotaxic injection performed only unilaterally, which mimics an early-to-mid stage of the disease.


Assuntos
Modelos Animais de Doenças , Neurônios Dopaminérgicos/efeitos dos fármacos , Oxidopamina/toxicidade , Doença de Parkinson Secundária/induzido quimicamente , Doença de Parkinson Secundária/cirurgia , Animais , Oxidopamina/administração & dosagem , Ratos
13.
Methods Mol Biol ; 846: 365-81, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22367826

RESUMO

Brain microdialysis is an analytical technique used for the dynamic monitoring of brain neurochemistry in awake, freely moving animals. This technique requires the insertion of a small dialysis catheter, called a microdialysis probe, into a specific brain region, and its perfusion with an artificial extracellular fluid. The microdialysate samples, obtained from the probe outlet, can be analysed using high-performance liquid chromatography with electrochemical detection for the quantification of oxidizable molecules recovered from the extracellular space. In this chapter, we describe a protocol for performing a microdialysis setup and experiment in freely moving rats and mice. Furthermore, the high-performance liquid chromatographic determination of ascorbic acid, uric acid, catecholamines, indolamines and derivatives is described in detail.


Assuntos
Química Encefálica , Técnicas de Química Analítica , Líquido Extracelular/química , Microdiálise/métodos , Animais , Ácido Ascórbico/análise , Catecolaminas/análise , Cromatografia Líquida de Alta Pressão/métodos , Eletroquímica , Indóis/análise , Camundongos , Ratos , Ácido Úrico/análise
14.
Talanta ; 85(4): 1933-40, 2011 Sep 30.
Artigo em Inglês | MEDLINE | ID: mdl-21872041

RESUMO

Microdialysis is an extensively used technique for both in vivo and in vitro experiments, applicable to animal and human studies. In neurosciences, the in vivo microdialysis is usually performed to follow changes in the extracellular levels of substances and to monitor neurotransmitters release in the brain of freely moving animals. Catecholamines, such as dopamine and their related compounds, are involved in the neurochemistry and in the physiology of mental diseases and neurological disorders. It is generally supposed that the brain's energy requirement is supplied by glucose oxidation. More recently, lactate was proposed to be the metabolic substrate used by neurons during synaptic activity. In our study, an innovative microdialysis approach for simultaneous monitoring of catecholamines, indolamines, glutamate and energy substrates in the striatum of freely moving rats, using an asymmetric perfusion flow rate on microdialysis probe, is described. As a result of this asymmetric perfusion, two samples are available from the same brain region, having the same analytes composition but different concentrations. The asymmetric flow perfusion could be a useful tool in neurosciences studies related to brain's energy requirement, such as toxin-induced models of Parkinson's disease.


Assuntos
Encéfalo/metabolismo , Microdiálise/métodos , Neurotransmissores/metabolismo , Animais , Metabolismo Energético , Masculino , Microdiálise/instrumentação , Neostriado/metabolismo , Perfusão , Ratos , Reprodutibilidade dos Testes , Fatores de Tempo
15.
CNS Neurol Disord Drug Targets ; 9(4): 482-90, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20522009

RESUMO

The classical animal models of Parkinson's disease (PD) rely on the use of neurotoxins, including 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP), 6-hydroxydopamine and, more recently, the agricultural chemicals paraquat and rotenone, to deplete dopamine (DA). These neurotoxins elicit motor deficits in different animal species although MPTP fails to induce a significant dopaminergic neurodegeneration in rats. In the attempt to better reproduce the key features of PD, in particular the progressive nature of neurodegeneration, alternative PD models have been developed, based on the genetic and neuropathological links between -synuclein ( -syn) and PD. In vivo microdialysis was used to investigate extracellular striatal DA dynamics in MPTP- and -syn-generated rodent models of PD. Acute and sub-acute MPTP intoxication of mice both induce prolonged release of striatal DA. Such DA release may be considered the first step in MPTP-induced striatal DA depletion and nigral neuron death, mainly through reactive oxygen species generation. Although MPTP induces DA reduction, neurochemical and motor recovery starts immediately after the end of treatment, suggesting that compensatory mechanisms are activated. Thus, the MPTP mouse model of PD may be unsuitable for closely reproducing the features of the human disease and predicting potential long-term therapeutic effects, in terms of both striatal extracellular DA and behavioral outcome. In contrast, the -syn-generated rat model of PD does not suffer from a massive release of striatal DA during induction of the nigral lesion, but rather is characterized by a prolonged reduction in baseline DA and nicotine-induced increases in dialysate DA levels. These results are suggestive of a stable nigrostriatal lesion with a lack of dopaminergic neurochemical recovery. The -syn rat model thus reproduces the initial stage and slow development of PD, with a time-dependent impairment in motor function. This article will describe the above experimental PD models and demonstrate the utility of microdialysis for their characterization.


Assuntos
1-Metil-4-Fenil-1,2,3,6-Tetra-Hidropiridina/farmacologia , Modelos Animais de Doenças , Dopamina/fisiologia , Microdiálise , Neurotoxinas/farmacologia , Doença de Parkinson/metabolismo , Transtornos Parkinsonianos/metabolismo , alfa-Sinucleína/metabolismo , Animais , Encéfalo/efeitos dos fármacos , Encéfalo/metabolismo , Dopamina/metabolismo , Humanos , Camundongos , Camundongos Transgênicos/genética , Camundongos Transgênicos/metabolismo , Transtornos Parkinsonianos/induzido quimicamente , Ratos , Ratos Transgênicos/genética , Ratos Transgênicos/metabolismo , alfa-Sinucleína/fisiologia
16.
Anal Chem ; 82(12): 5134-40, 2010 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-20503971

RESUMO

Ascorbic acid (AA), one of the principal micronutrients in horticultural crops, plays a key role in the human metabolism, and its determination in food products has a great significance. Citrus fruits are rich in AA, but its content is highly susceptible to change during postharvest processing and storage. We present a new ultralow-cost system, constituted of an amperometric microsensor composed of three rod carbon electrodes connected to a telemetric device, for online detection of AA in orange juice, as an alternative to conventional analytical methods. The in vitro calibration, ranged from 0 to 5 mM, and AA juice content was calculated by adding low volumes of sample into an acetate buffer solution at a constant potential of +120 mV vs carbon pseudoreference. This new approach, which is simple, expandable, and inexpensive, seems appropriate for large scale commercial use.


Assuntos
Ácido Ascórbico/análise , Citrus/química , Técnicas Eletroquímicas/instrumentação , Telemetria/instrumentação , Calibragem , Técnicas Eletroquímicas/economia , Desenho de Equipamento , Telemetria/economia
17.
Anal Chem ; 81(6): 2235-41, 2009 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-19222224

RESUMO

A miniaturized biotelemetric device for the amperometric detection of brain tissue oxygen is presented. The new system, derived from a previous design, has been coupled with a carbon microsensor for the real-time detection of dissolved O(2) in the striatum of freely moving rats. The implantable device consists of a single-supply sensor driver, a current-to-voltage converter, a microcontroller, and a miniaturized data transmitter. The oxygen current is converted to a digital value by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC). The digital data is sent to a personal computer using a six-byte packet protocol by means of a miniaturized 434 MHz amplitude modulation (AM) transmitter. The receiver unit is connected to a personal computer (PC) via a universal serial bus. Custom developed software allows the PC to store and plot received data. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption, and good linear response in the nanoampere current range. The in vivo results confirmed previously published observations on oxygen dynamics in the striatum of freely moving rats. The system serves as a rapid and reliable model for studying the effects of different drugs on brain oxygen and brain blood flow and it is suited to work with direct-reduction sensors or O(2)-consuming biosensors.


Assuntos
Técnicas Biossensoriais/métodos , Encéfalo/metabolismo , Oxigênio/análise , Acetazolamida/farmacologia , Animais , Técnicas Biossensoriais/instrumentação , Corpo Estriado/metabolismo , Masculino , Miniaturização , Ratos , Ratos Sprague-Dawley , Telemetria
18.
Sensors (Basel) ; 9(4): 2511-23, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-22574029

RESUMO

In this study we present the real-time monitoring of three key brain neurochemical species in conscious rats using implantable amperometric electrodes interfaced to a biotelemetric device. The new system, derived from a previous design, was coupled with carbon-based microsensors and a platinum-based biosensor for the detection of ascorbic acid (AA), O(2) and glucose in the striatum of untethered, freely-moving rats. The miniaturized device consisted of a single-supply sensor driver, a current-to-voltage converter, a microcontroller and a miniaturized data transmitter. The redox currents were digitized to digital values by means of an analog-to-digital converter integrated in a peripheral interface controller (PIC), and sent to a personal computer by means of a miniaturized AM transmitter. The electronics were calibrated and tested in vitro under different experimental conditions and exhibited high stability, low power consumption and good linear response in the nanoampere current range. The in-vivo results confirmed previously published observations on striatal AA, oxygen and glucose dynamics recorded in tethered rats. This approach, based on simple and inexpensive components, could be used as a rapid and reliable model for studying the effects of different drugs on brain neurochemical systems.

19.
Anal Biochem ; 380(2): 323-30, 2008 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-18577368

RESUMO

A novel dual channel in vitro apparatus, derived from a previously described design, has been coupled with dopamine (DA) microsensors for the flow-through detection of DA secreted from PC12 cells. The device, including two independent microdialysis capillaries, was loaded with a solution containing PC12 cells while a constant phosphate-buffered saline (PBS) medium perfusion was carried out using a dual channel miniaturized peristaltic pump. One capillary was perfused with normal PBS, whereas extracellular calcium was removed from extracellular fluid of the second capillary. After a first period of stabilization and DA baseline recording, KCl (75 mM) was added to the perfusion fluid of both capillaries. In this manner, a simultaneous "treatment-control" experimental design was performed to detect K+-evoked calcium-dependent DA secretion. For this purpose, self-referencing DA microsensors were developed, and procedures for making, testing, and calibrating them are described in detail. The electronic circuitry was derived from previously published schematics and optimized for dual sensor constant potential amperometry applications. The microdialysis system was tested and validated in vitro under different experimental conditions, and DA secretion was confirmed by high-performance liquid chromatography with electrochemical detection (HPLC-EC). PC12 cell viability was quantified before and after each experiment. The proposed apparatus serves as a reliable model for studying the effects of different drugs on DA secretion through the direct comparison of extracellular DA increase in treatment-control experiments performed on the same initial PC12 cell population.


Assuntos
Dopamina/análise , Eletroquímica/métodos , Microdiálise/métodos , Animais , Cálcio/farmacologia , Calibragem , Contagem de Células , Sobrevivência Celular , Dopamina/metabolismo , Eletroquímica/instrumentação , Microdiálise/instrumentação , Células PC12 , Cloreto de Potássio/farmacologia , Ratos , Reprodutibilidade dos Testes , Taxa Secretória/efeitos dos fármacos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...