Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
J Arthroplasty ; 33(8): 2677-2683, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29681493

RESUMO

BACKGROUND: All polyethylene acetabular liners wear over time, and numerous methods for calculating linear wear rates exist. The objective of this study was to compare 2-dimensional wear rates between direct, micrometer measurements and the computerized, edge-detection method using Hip Analysis Suite (HAS) 8.0.4.3. METHODS: Two groups of retrieved acetabular liners from Harris-Galante Prosthesis I and Harris-Galante Prosthesis II implants in situ for more than 10 years were evaluated. Group 1 (n = 18) contained liners with both early postoperative (<6 months) and prerevision radiographs taken within 1 month of explantation. Group 2 (n = 55) included liners with only prerevision X-rays (ie, 1 radiograph for wear assessment). Average and maximum direct linear wear was calculated from thicknesses measured at 6 consistent, well-separated locations (3 in the worn and 3 in the unworn regions) using a calibrated, digital micrometer. HAS 8.0.4.3 was used to calculate 2-dimensional wear from anteroposterior pelvic radiographs. RESULTS: Aggregate wear rates calculated by HAS were higher than those calculated by the average of direct measurements for group 1 (P = .020) and group 2 (P < .001). However, comparing the maximum direct micrometer measurements to HAS showed no difference for either group 1 (P = .351) or group 2 (P = .451). Linear regression analysis showed a strong correlation between HAS and both average and maximum direct wear measures for both groups, though the coefficient for the direct maximum measurement comparisons were closer to one, indicating a better one-to-one correspondence between HAS and direct maximum wear. CONCLUSION: To our knowledge, this is the first study to compare and validate 2-dimensional wear rates in polyethylene acetabular liners between direct measurements from retrieved components and a radiographic computer-assisted technique (as opposed to comparison against a phantom component). Wear rates determined by direct measurements from retrievals were consistent with computer-assisted 2-dimensional methods when comparing maximum wear measurements. In addition, a single prerevision radiograph appears to be sufficient to assess 2-dimensional in vivo wear.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril , Polietileno/efeitos adversos , Falha de Prótese , Adulto , Idoso , Remoção de Dispositivo , Feminino , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Radiografia , Análise de Regressão
2.
J Bone Joint Surg Am ; 98(4): 285-94, 2016 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-26888676

RESUMO

BACKGROUND: Proinflammatory signaling by toll-like receptors (TLRs) likely contributes to biologic responses to wear particles causing aseptic loosening. We recently reported associations with aseptic loosening in patients with polymorphisms in the locus encoding an adapter protein specific for TLR-2 and TLR-4 known as toll/interleukin-1 receptor domain-containing adapter protein/MyD88 adapter-like (TIRAP/Mal). To directly examine the contribution of TIRAP/Mal, we tested the hypothesis that TIRAP/Mal deficiency reduces the activity of wear particles. Signaling by TLR-2 and TLR-4 through TIRAP/Mal can be activated by bacterial pathogen-associated molecular patterns (PAMPs) such as lipopolysaccharide or endogenous alarmins. To distinguish between those possibilities, we tested the hypothesis that the effects of TIRAP/Mal depend on the adherence of bacterial PAMPs to the particles. METHODS: In vitro mRNA levels and secretion of tumor necrosis factor-α, interleukin (IL)-1ß, and IL-6 were measured after incubating wild-type and TIRAP/Mal(-/-) macrophages in the presence or absence of titanium particles with adherent bacterial debris, so-called endotoxin-free particles, or particles with adherent lipopolysaccharide. In vivo osteolysis was measured after implanting titanium particles on the calvaria of wild-type and TIRAP/Mal(-/-) mice. RESULTS: TIRAP/Mal deficiency significantly inhibited the activity of titanium particles with adherent bacterial debris to stimulate in vivo osteolysis and in vitro cytokine mRNAs and secretion. Those effects are dependent on adherent PAMPs because removal of >99% of the adherent bacterial debris from the particles significantly reduced their activity and the remaining activity was not dependent on TIRAP/Mal. Moreover, adherence of highly purified lipopolysaccharide to the endotoxin-free particles reconstituted the activity and the dependence on TIRAP/Mal. CONCLUSIONS: TIRAP/Mal deficiency reduces inflammatory responses and osteolysis induced by particles with adherent PAMPs. CLINICAL RELEVANCE: Our results, coupled with the genetic associations between aseptic loosening and polymorphisms within the TIRAP/Mal locus, support TLR signaling through TIRAP/Mal as one of the factors that enhances the activity of wear particles and further support the hypothesis that bacterial PAMPs likely contribute to aseptic loosening in a subset of patients.


Assuntos
Prótese Articular/efeitos adversos , Glicoproteínas de Membrana/metabolismo , Osteólise/etiologia , Moléculas com Motivos Associados a Patógenos/metabolismo , Receptores de Interleucina-1/metabolismo , Titânio/efeitos adversos , Animais , Biomarcadores/metabolismo , Citocinas/metabolismo , Feminino , Lipopolissacarídeos/metabolismo , Macrófagos/metabolismo , Glicoproteínas de Membrana/deficiência , Camundongos , Camundongos Endogâmicos C57BL , Camundongos Knockout , Osteólise/metabolismo , Osteólise/microbiologia , Falha de Prótese , Distribuição Aleatória , Receptores de Interleucina-1/deficiência
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...