Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 28
Filtrar
1.
Eur Spine J ; 30(3): 628-633, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33156440

RESUMO

PURPOSE: Adolescent idiopathic scoliosis (AIS) patients are exposed to 9-10 times more radiation and a fivefold increased lifetime cancer risk. Radiation-free imaging alternatives are needed. Ultrasound imaging of spinal curvature was shown to be accurate, however, systematically underestimating the Cobb angle. The purpose of this study is to create and cross-validate an equation that calculates the expected Cobb angle using ultrasound spinal measurements of AIS patients. METHODS: Seventy AIS patients with upright radiography and spinal ultrasound were split randomly in a 4:1 ratio to the equation creation (n = 54) or validation (n = 16) group. Ultrasound angles based on the spinous processes shadows were measured automatically by the ultrasound system (Scolioscan, Telefield, Hong Kong). For thoracic and lumbar curves separately, the equation: expected Cobb angle = regression coefficient × ultrasound angle, was created and subsequently cross-validated in the validation group. RESULTS: Linear regression analysis between ultrasound angles and radiographic Cobb angles (thoracic: R2 = 0.968, lumbar: R2 = 0.923, p < 0.001) in the creation group resulted in the equations: thoracic Cobb angle = 1.43 × ultrasound angle and lumbar Cobb angle = 1.23 × ultrasound angle. With these equations, expected Cobb angles in the validation group were calculated and showed an excellent correlation with the radiographic Cobb angles (thoracic: R2 = 0.959, lumbar: R2 = 0.936, p < 0.001). The mean absolute differences were 6.5°-7.3°. Bland-Altman plots showed good accuracy and no proportional bias. CONCLUSION: The equations from ultrasound measurements to Cobb angles were valid and accurate. This supports the implementation of ultrasound imaging, possibly leading to less frequent radiography and reducing ionizing radiation in AIS patients.


Assuntos
Cifose , Escoliose , Adolescente , Hong Kong , Humanos , Escoliose/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Vértebras Torácicas/diagnóstico por imagem , Ultrassonografia
2.
Blood Adv ; 4(1): 113-121, 2020 01 14.
Artigo em Inglês | MEDLINE | ID: mdl-31917842

RESUMO

Magnetic resonance imaging (MRI) is considered as the reference standard to assess early joint changes in hemophilia. However, the clinical relevance of MRI findings is still unknown. The aim of this prospective study was to assess the predictive value of MRI for 5-year joint bleeding and progression of arthropathy in patients with hemophilia. Both knees and ankles of patients with hemophilia and absent or limited arthropathy on radiographs were assessed by using MRI and radiographs. MRI scans were scored according to the International Prophylaxis Study Group MRI score for hemophilic arthropathy. Patients were followed up for 5 years, including assessment of joint bleeding and repeated radiographic assessment. Associations between baseline MRI findings with 5-year bleeding and progression of arthropathy were expressed as odds ratios (OR), adjusted for severity of disease and joint bleeding history. Baseline assessment included 104 joints of 26 patients with hemophilia (median age, 21 years). Four ankles with severe joint changes were excluded. Follow-up was available for 96 (92%) of 104 joints. During 5 years of follow-up, bleeding was reported for 36% of joints. Five-year bleeding was significantly increased in joints with synovial hypertrophy at 80% vs 27% in joints without synovial hypertrophy (OR, 10.1; 95% confidence interval, 3.4-31.3). In joints with normal baseline radiographs, any osteochondral or synovial changes on MRI were associated with radiographic changes 5 years later (positive predictive value, 75%; negative predictive value, 98%). Joints with synovial hypertrophy on MRI had a significantly higher chance of 5-year bleeding. All MRI changes, except effusion, were strong predictors for development of arthropathy on radiographs.


Assuntos
Hemofilia A , Adulto , Hemartrose/diagnóstico por imagem , Hemartrose/etiologia , Hemofilia A/complicações , Hemofilia A/diagnóstico por imagem , Hemorragia/diagnóstico por imagem , Hemorragia/etiologia , Humanos , Imageamento por Ressonância Magnética , Estudos Prospectivos , Adulto Jovem
3.
Spine J ; 18(6): 979-985, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29056566

RESUMO

BACKGROUND CONTEXT: Radiation exposure remains a big concern in adolescent idiopathic scoliosis (AIS). Ultrasound imaging of the spine could significantly reduce or possibly even eliminate this radiation hazard. The spinous processes (SPs) and transverse processes (TPs) were used to measure the coronal deformity. Both landmarks provided reliable information on the severity of the curve as related to the traditional Cobb angle. However, it remained unclear which coronal ultrasound angle is the most appropriate method to measure the curve severity. PURPOSE: The objective of this study was to test the reliability and the validity of several ultrasound angle measurements in the coronal plane as compared with the radiographic coronal Cobb angle in patients with AIS. STUDY DESIGN/SETTING: This is a cross-sectional study. PATIENT SAMPLE: The study included 33 patients with AIS, both male and female (Cobb angle range: 3°-90°, primary and secondary curves), who underwent posterior-anterior radiography of the spine. OUTCOME MEASURES: The outcome measures were the reliability (intraclass correlation coefficients [ICCs] for the intra- and interobserver variabilities) and the validity (linear regression analysis and Bland-Altman method, including the mean absolute difference [MAD]) of different ultrasound measurements. MATERIALS AND METHODS: The patients were scanned using a dedicated ultrasound machine (Scolioscan, Telefield Medical Imaging Ltd, Hong Kong). The reliability and the validity were tested for three coronal ultrasound angles: an automatic and manual SP angle and a manual TP angle as compared with the radiographic coronal main thoracic or (thoraco)lumbar Cobb angles. RESULTS: The ICC showed very reliable measurements of all ultrasound methods (ICC ≥0.84). The ultrasound angles were 15%-37% smaller as compared with the Cobb angles; however, excellent linear correlations were seen between all ultrasound angles and the Cobb angle (thoracic: R2≥0.987 and (thoraco)lumbar R2≥0.970), and the Bland-Altman plot showed a good agreement between all ultrasound angles and the Cobb angle. The MADs of the ultrasound angles, corrected using the linear regression equation, and the Cobb angles showed no significant difference between the different ultrasound angles (MAD: automatic SP angle 4.9°±3.2°, manual SP angle 4.5°±3.1°, and manual TP angle 4.7°±3.6°; p≥.388). CONCLUSIONS: Coronal ultrasound angles are based on different landmarks than the traditional Cobb angle measurement and cannot represent the same angle values. In this study, we found excellent correlations between the ultrasound and Cobb measurements, without differences in the reliability and validity between the ultrasound angles based on the SPs and TPs. Therefore, the severity of the deformity in patients with AIS can be assessed by ultrasound imaging, avoiding hazardous ionizing radiation and enabling more individualized patient care. It also opens possibilities for screening.


Assuntos
Escoliose/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Ultrassonografia/normas
4.
Eur Radiol ; 26(6): 1963-70, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26403578

RESUMO

OBJECTIVES: The radiological Pettersson score (PS) is widely applied for classification of arthropathy to evaluate costly haemophilia treatment. This study aims to assess and improve inter- and intra-observer reliability and agreement of the PS. METHODS: Two series of X-rays (bilateral elbows, knees, and ankles) of 10 haemophilia patients (120 joints) with haemophilic arthropathy were scored by three observers according to the PS (maximum score 13/joint). Subsequently, (dis-)agreement in scoring was discussed until consensus. Example images were collected in an atlas. Thereafter, second series of 120 joints were scored using the atlas. One observer rescored the second series after three months. Reliability was assessed by intraclass correlation coefficients (ICC), agreement by limits of agreement (LoA). RESULTS: Median Pettersson score at joint level (PSjoint) of affected joints was 6 (interquartile range 3-9). Using the consensus atlas, inter-observer reliability of the PSjoint improved significantly from 0.94 (95 % confidence interval (CI) 0.91-0.96) to 0.97 (CI 0.96-0.98). LoA improved from ±1.7 to ±1.1 for the PSjoint. Therefore, true differences in arthropathy were differences in the PSjoint of >2 points. Intra-observer reliability of the PSjoint was 0.98 (CI 0.97-0.98), intra-observer LoA were ±0.9 points. CONCLUSIONS: Reliability and agreement of the PS improved by using a consensus atlas. KEY POINTS: • Reliability of the Pettersson score significantly improved using the consensus atlas. • The presented consensus atlas improved the agreement among observers. • The consensus atlas could be recommended to obtain a reproducible Pettersson score.


Assuntos
Articulação do Tornozelo/diagnóstico por imagem , Consenso , Hemofilia A/complicações , Artropatias/diagnóstico , Articulações/diagnóstico por imagem , Radiografia/métodos , Adulto , Feminino , Humanos , Artropatias/etiologia , Masculino , Pessoa de Meia-Idade , Curva ROC , Reprodutibilidade dos Testes , Índice de Gravidade de Doença
5.
J Comput Assist Tomogr ; 40(2): 261-5, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26599962

RESUMO

OBJECTIVE: To determine pretreatment computed tomography observer agreement in patients with newly diagnosed lymphoma. METHODS: Forty-nine computed tomography scans were reviewed by 3 experienced radiologists, with each scan assessed twice by 1 observer. Predefined nodal and extranodal regions were assessed, and Ann Arbor stages were assigned. K-statistics were defined as poor (κ < 0.2), fair (κ > 0.2 to κ ≤ 0.4), moderate (κ > 0.4 to κ ≤ 0.6), substantial (κ > 0.6 to κ ≤ 0.8), and almost perfect (κ > 0.8 to κ ≤ 1). RESULTS: Nodal interobserver agreement varied from 0.09 for infraclavicular involvement to 0.95 for para-iliac involvement; intraobserver agreement was substantial to almost perfect, except for infraclavicular nodes. Extranodal interobserver agreement varied from 0.56 to 0.88; intraobserver agreement was substantial to almost perfect. Ann Arbor stage interobserver agreement varied from 0.57 to 0.69; intraobserver agreement was substantial. CONCLUSION: Computed tomography observer agreement in staging malignant lymphoma appears to be suboptimal.


Assuntos
Linfoma/diagnóstico por imagem , Linfoma/patologia , Tomografia Computadorizada por Raios X , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Estudos de Coortes , Feminino , Humanos , Linfonodos/diagnóstico por imagem , Linfonodos/patologia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
6.
J Magn Reson Imaging ; 42(6): 1646-55, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25952024

RESUMO

BACKGROUND: To assess the performance of whole-body MRI including diffusion-weighted imaging (whole-body MRI-DWI) for the detection of residual disease after completion of treatment in lymphoma patients. METHODS: Twenty-six patients with lymphoma prospectively underwent whole-body MRI-DWI (1.5 Tesla MR) and 18F-fluoro-2-deoxy-D-glucose positron emission tomography (FDG-PET)/computed tomography (CT) for posttreatment evaluation which were visually assessed. Apparent diffusion coefficient (ADC) and FDG-PET/CT standardized uptake value measurements were performed in all residual lesions. An unblinded expert panel reviewed all cases and determined the presence or absence of posttreatment residual disease using all available imaging (except for whole-body MRI-DWI), clinical, and histopathological information with a follow-up of at least 6 months. The performance of whole-body MRI-DWI was compared with this panel reference standard. RESULTS: Five of 26 patients were diagnosed with residual disease. Sensitivity and specificity for detection of residual disease with whole-body MRI-DWI were 100% and 62%, respectively. By ROC analysis, the optimal threshold of ADC was 1.21 × 10(-3) mm(2) /s with sensitivity and specificity of 100% and 91.7%, respectively. CONCLUSION: Our initial results suggest that visual whole-body MRI-DWI analysis has a very good sensitivity for detecting viable residual lesions after completion of therapy but lacks specificity. ADC measurements could potentially increase the specificity of whole-body MRI.


Assuntos
Antineoplásicos/uso terapêutico , Imagem de Difusão por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Linfoma/tratamento farmacológico , Linfoma/patologia , Imagem Corporal Total/métodos , Algoritmos , Feminino , Seguimentos , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Estudos Longitudinais , Masculino , Imagem Multimodal/métodos , Neoplasia Residual , Países Baixos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Singapura , Espanha , Resultado do Tratamento
7.
Neurourol Urodyn ; 34(6): 513-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24706504

RESUMO

AIMS: To study additional benefits of performing Tc-99m dimercaptosuccinic acid (Tc-99m-DMSA) scintigraphy as part of the follow-up of adults with spinal dysraphism (SD), compared with ultrasonography, with regard to finding renal scarring and difference in split renal function. METHODS: Between January 2011 and April 2013 every patient visiting our specialized outpatient clinic for adults with SD was invited to undergo both renal ultrasonography and Tc-99m-DMSA scintigraphy. Outcomes of both modalities were compared, with focus on renal scarring. The relation between renal scarring and hypertension was also assessed. RESULTS: In total, 122 patients (with 242 renal units) underwent both renal scintigraphy and ultrasonography. More scars were seen on DMSA scintigraphy than on ultrasonography: 45.9% vs. 10.3% of renal units; P < 0.001. Renal scarring seen on DMSA was associated with the presence of hypertension (P = 0.049) whereas scarring seen on ultrasonography was not (P = 0.10). If ultrasonography was difficult to interpret, many more scars were missed on ultrasonography (78.9%) compared with easily interpretable ultrasonographic images (30.6%; P < 0.001). CONCLUSIONS: In adults with SD, ultrasonography is of value to diagnose dilatation and stones of the upper urinary tract; however, compared with DMSA renography, renal scars are often missed, especially when the ultrasound is difficult to interpret.


Assuntos
Rim/diagnóstico por imagem , Imagem Multimodal/métodos , Compostos Radiofarmacêuticos , Disrafismo Espinal/diagnóstico por imagem , Ácido Dimercaptossuccínico Tecnécio Tc 99m , Adulto , Pressão Sanguínea , Cicatriz/diagnóstico por imagem , Feminino , Taxa de Filtração Glomerular , Humanos , Hipertensão Renal/diagnóstico por imagem , Cálculos Renais/diagnóstico por imagem , Masculino , Cintilografia , Ultrassonografia , Adulto Jovem
8.
AJR Am J Roentgenol ; 203(3): 656-61, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25148172

RESUMO

OBJECTIVE: The purpose of this study was to develop a simple semiquantitative high-resolution CT (HRCT) scoring system to differentiate alloimmune-mediated lung syndromes (allo-LS) from other lung diseases early after hematopoietic cell transplantation. Allo-LS should be differentiated from other abnormalities, such as infections and toxicity, because they are life threatening and require prompt and specific treatment. MATERIALS AND METHODS: In 52 pediatric hematopoietic cell transplant recipients with early symptoms of pulmonary disease, a clinical diagnosis was made by an expert physician. HRCT studies were scored by two independent radiologists for various airway and parenchyma abnormalities. HRCT scores were compared with the final clinical diagnoses. RESULTS: Patients with allo-LS had significantly higher HRCT severity scores for ground-glass pattern and airtrapping compared with patients with nonalloimmune disease. A combined score was constructed (the "allo-score") that appeared to have good predictive capacity for clinical allo-LS (AUC = 0.82). HRCT scoring was reproducible for all items except airway wall thickening and septal thickening. CONCLUSION: A simple HRCT severity score can be helpful to differentiate allo-LS from other pulmonary complications early after hematopoietic cell transplantation.


Assuntos
Algoritmos , Doenças Autoimunes/diagnóstico por imagem , Doenças Autoimunes/etiologia , Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Pneumopatias/diagnóstico por imagem , Pneumopatias/etiologia , Tomografia Computadorizada por Raios X/métodos , Adolescente , Criança , Pré-Escolar , Diagnóstico Diferencial , Feminino , Humanos , Lactente , Masculino , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Transplante Homólogo/efeitos adversos
9.
J Comput Assist Tomogr ; 38(4): 620-5, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24681861

RESUMO

OBJECTIVE: To determine whether full-dose contrast-enhanced computed tomography (CT) (CECT) can be omitted from an F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) (FDG-PET)/CT staging examination in newly diagnosed FDG-avid lymphoma. METHODS: Twenty-nine patients with newly diagnosed FDG-avid lymphoma prospectively underwent unenhanced low-dose FDG-PET/CT and CECT. Different observers evaluated unenhanced low-dose FDG-PET/CT and CECT in a blinded manner. Ann Arbor stages according to unenhanced low-dose FDG-PET/CT and CECT were compared, and discrepancies between the 2 imaging modalities were resolved using bone marrow biopsy and posttreatment FDG-PET/CT as reference standard. Finally, it was assessed as to how many cases therapy would have been changed based on additional CECT findings. RESULTS: In 27 of 29 patients (93%; 95% confidence interval, 78%-98%), CECT either did not change or did not correctly change the Ann Arbor stage that was assigned according to unenhanced low-dose FDG-PET findings. In 2 of 29 patients (7%; 95% confidence interval, 2%-22%), CECT correctly provided another Ann Arbor stage than unenhanced low-dose FDG-PET/CT. In the latter 2 cases, therapy would not have been changed based on additional CECT findings. CONCLUSIONS: Unenhanced low-dose FDG-PET/CT alone is suggested as the primary imaging modality of choice for staging patients with newly diagnosed FDG-avid lymphoma. This diagnostic approach is particularly indicated in younger patients in whom diagnostic radiation exposure should be minimized and in patients who are at increased risk of CT contrast-induced allergic reactions or nephropathy.


Assuntos
Fluordesoxiglucose F18 , Linfoma/diagnóstico , Linfoma/patologia , Imagem Multimodal/métodos , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Ácido Iotalâmico/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Adulto Jovem
10.
Eur Radiol ; 24(5): 1153-65, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24563179

RESUMO

OBJECTIVE: To compare whole-body MRI, including diffusion-weighted imaging (whole-body MRI-DWI), with FDG-PET/CT for staging newly diagnosed paediatric lymphoma. METHODS: A total of 36 children with newly diagnosed lymphoma prospectively underwent both whole-body MRI-DWI and FDG-PET/CT. Whole-body MRI-DWI was successfully performed in 33 patients (mean age 13.9 years). Whole-body MRI-DWI was independently evaluated by two blinded observers. After consensus reading, an unblinded expert panel evaluated the discrepant findings between whole-body MRI-DWI and FDG-PET/CT and used bone marrow biopsy, other imaging data and clinical information to derive an FDG-PET/CT-based reference standard. RESULTS: Interobserver agreement of whole-body MRI-DWI was good [all nodal sites together (κ = 0.79); all extranodal sites together (κ = 0.69)]. There was very good agreement between the consensus whole-body MRI-DWI- and FDG-PET/CT-based reference standard for nodal (κ = 0.91) and extranodal (κ = 0.94) staging. The sensitivity and specificity of consensus whole-body MRI-DWI were 93 % and 98 % for nodal staging and 89 % and 100 % for extranodal staging, respectively. Following removal of MRI reader errors, the disease stage according to whole-body MRI-DWI agreed with the reference standard in 28 of 33 patients. CONCLUSIONS: Our results indicate that whole-body MRI-DWI is feasible for staging paediatric lymphoma and could potentially serve as a good radiation-free alternative to FDG-PET/CT. KEYPOINTS: • Accurate staging is important for treatment planning and assessing prognosis • Whole-body MRI-DWI could be a good radiation-free alternative to FDG-PET/CT • Interobserver agreement of whole-body MRI-DWI is good • Agreement between whole-body MRI and the FDG-PET/CT reference standard is good • Most discrepancies were caused by suboptimal accuracy of size measurements on MRI.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Fluordesoxiglucose F18 , Linfoma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos , Adolescente , Criança , Feminino , Humanos , Masculino , Estadiamento de Neoplasias , Variações Dependentes do Observador , Prognóstico , Estudos Prospectivos , Padrões de Referência , Sensibilidade e Especificidade , Imagem Corporal Total
11.
J Magn Reson Imaging ; 40(1): 26-36, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24307538

RESUMO

PURPOSE: To compare whole-body magnetic resonance imaging (MRI), including diffusion-weighted imaging (DWI), to computed tomography (CT) for staging newly diagnosed lymphoma. MATERIALS AND METHODS: In all, 108 patients with newly diagnosed lymphoma prospectively underwent whole-body MRI (T1-weighted and T2-weighted short inversion time inversion recovery [n = 108], and DWI [n = 104]) and CT. Ann Arbor stages were assigned according to whole-body MRI and CT findings. Staging disagreements were resolved using bone marrow biopsy, FDG-PET, and follow-up studies. The results were descriptively analyzed. RESULTS: Staging results of whole-body MRI without DWI were equal to those of CT in 66.6%, higher in 24.1%, and lower in 9.3%, with correct/incorrect/unresolved higher staging and incorrect/unresolved lower staging relative to CT in 15/7/4 and 9/1 patient(s), respectively. Staging results of whole-body MRI with DWI were equal to those of CT in 65.4%, higher in 27.9%, and lower in 6.7%, with correct/incorrect/unresolved higher staging and incorrect/unresolved lower staging relative to CT in 18/6/5 and 6/1 patient(s), respectively. CONCLUSION: The results of this study suggest that whole-body MRI staging equals CT staging in the majority of patients with newly diagnosed lymphoma. No advantage of additional DWI was demonstrated. Whole-body MRI can be a good alternative to CT if radiation exposure should be avoided.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Aumento da Imagem/métodos , Linfoma/patologia , Estadiamento de Neoplasias/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
12.
World J Surg ; 37(8): 1934-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23543225

RESUMO

BACKGROUND: Anorectal malformation is a complex anomaly with a broad variety of expressions. There are different techniques available for correction of the anomaly, all with their specific morbidity. Recently, much attention has been paid to acquired posterior urethral diverticulum after correction of anorectal malformation. The aim of this retrospective study was to reappraise the laparoscopic approach to correction of the anorectal malformation with respect to what can be prevented and what can be improved. METHODS: Between July 2000 and July 2011, a total of 19 boys born with a high or intermediate anorectal malformation were admitted to our center. All patients underwent a diagnostic workup and were included in the follow-up protocol. Follow-up continence was scored according to the Krickenbeck criteria. Patients were also invited for an ultrasound and micturition cystourethrogram (MCUG) at follow-up to determine or exclude the presence of a posterior urethral diverticulum. RESULTS: All patients underwent a successful laparoscopy-assisted anorectal pull-through. Mean age at the time of surgery was 2.5 months. Mean length of hospital stay was 5 days. Mean follow-up was 73 months. Complications were encountered in six patients. At follow-up 53 % of all our patients had spontaneous bowel movements and 41 % needed the help of laxatives or rectal washouts. In three patients a residual blind ending fistula was determined on MCUG but there was no true diverticulum. CONCLUSION: Correction of anorectal malformation is a complex procedure with significant morbidity. Refinements of the technique may prevent complications and improve outcome in both the laparoscopic and posterior sagittal anorectoplasty. Acquired posterior urethral diverticulum does not necessarily need to occur more often with the laparoscopic approach.


Assuntos
Anus Imperfurado/cirurgia , Laparoscopia , Malformações Anorretais , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Retrospectivos
13.
Eur J Radiol ; 80(3): e536-43, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21292416

RESUMO

BACKGROUND: Hematopoietic stem cell transplantation (SCT) can be complicated by a variety of live-threatening infectious and non-infectious pulmonary complications. The management of these complications is critically dependent on the most probable diagnosis, which is in part based on imaging work-up. METHODS: Systematic review of the literature related to the diagnostic value of high-resolution computed tomography (HRCT) in patients who underwent SCT and developed respiratory symptoms. RESULTS: Literature review did not reveal systematic cohort studies that included patients with respiratory symptoms post-SCT who underwent HRCT and had a well-defined outcome. Most studies selected participants based on their final diagnosis instead of the indication for diagnostic testing in practice. Nevertheless, several papers clearly indicated a potential role for HRCT when complications after SCT occur. A variety of articles described the role of certain HRCT findings in the diagnosis of specific infectious complications, but less data were available for non-infectious complications. CONCLUSION: We believe more diagnostic studies are needed to determine the value of HRCT for a specific diagnosis in SCT-recipients who present with respiratory symptoms at the transplant clinic. Currently, radiologists should be cautious since HRCT interpretation in these patients is not unambiguous.


Assuntos
Transplante de Células-Tronco Hematopoéticas/efeitos adversos , Intensificação de Imagem Radiográfica/métodos , Transtornos Respiratórios/diagnóstico por imagem , Transtornos Respiratórios/etiologia , Tomografia Computadorizada por Raios X/métodos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
AJR Am J Roentgenol ; 196(3): 662-9, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21343511

RESUMO

OBJECTIVE: The purpose of this study was to compare whole-body MRI including diffusion-weighted imaging (DWI) with (18)F-FDG PET/CT in the staging of newly diagnosed lymphoma. SUBJECTS AND METHODS: Twenty-two consecutively registered patients with newly diagnosed lymphoma prospectively underwent whole-body MRI (22 with T1-weighted, STIR, and DWI sequences and 21 with T1-weighted and STIR sequences but not DWI) and FDG PET/CT. Whole-body MRI-DWI was independently evaluated by two blinded observers. Interobserver agreement was assessed, and whole-body MRI-DWI was compared with FDG PET/CT. RESULTS: The kappa values for interobserver agreement on whole-body MRI-DWI for all nodal regions together and for all extranodal regions together were 0.676 and 0.452. The kappa values for agreement between whole-body MRI-DWI and FDG PET/CT for all nodal regions together and for all extranodal regions together were 0.597 and 0.507. Ann Arbor stage according to whole-body MRI-DWI findings was concordant with that of FDG PET/CT findings in 77% (17/22) of patients. Understaging and overstaging relative to the findings with FDG PET/CT occurred in 0% (0/22) and 23% (5/22) of cases. In the care of 9% (2/22) of patients, overstaging with whole-body MRI-DWI relative to staging with FDG PET/CT would have had therapeutic consequences. CONCLUSION: Our early results indicate that overall interobserver agreement on whole-body MRI-DWI findings is moderate to good. Overall agreement between whole-body MRI-DWI and FDG PET/CT is moderate. In the care of patients with newly diagnosed lymphoma, staging with whole-body MRI-DWI does not result in underestimation of stage relative to the results with FDG PET/CT. In a minority of patients, reliance on whole-body MRI-DWI leads to clinically important overstaging relative to the results with FDG PET/CT. FDG PET/CT remains the reference standard for lymphoma staging until larger-scale studies show that use of whole-body MRI-DWI results in correct staging in this minority of cases.


Assuntos
Linfoma/patologia , Imageamento por Ressonância Magnética/métodos , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos
15.
Pediatr Radiol ; 40(11): 1794-9, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-20552186

RESUMO

BACKGROUND: Transinguinal sonography can be used to demonstrate the position of the femoral head after reduction of a dislocated hip. OBJECTIVE: To determine whether transinguinal sonography can replace radiography and CT in the follow-up after reduction of a hip dislocation? MATERIALS AND METHODS: Thirty-three children with 39 dislocated hips were followed up with sonography after reduction and immobilization in a spica cast. In cases of an abnormal position a CT scan was advised. A pelvic radiograph at the end of treatment served as an indicator that no dislocations were missed during the previous sonographic examinations. RESULTS: The repositioned hips were examined on 138 occasions. Twenty-four examinations were abnormal and CT scanning was performed on 11 occasions. In four children additional CT was done because a recurrent dislocation was suspected or because sonography was difficult to perform. No dislocations were demonstrated. In five children a recurrent dislocation was suspected, on one or more occasions. In all but one child a CT scan was performed that confirmed the dislocation. CONCLUSION: Transinguinal sonography is well-suited to demonstrate a normal position of the femoral head in a spica cast. Transinguinal sonography decreases the number of radiographs and CT scans and reduces the exposure to ionizing radiation.


Assuntos
Moldes Cirúrgicos , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/cirurgia , Luxação do Quadril/diagnóstico por imagem , Luxação do Quadril/cirurgia , Canal Inguinal/diagnóstico por imagem , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Prognóstico , Resultado do Tratamento , Ultrassonografia
16.
Pediatr Radiol ; 40(10): 1634-9, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-20544189

RESUMO

BACKGROUND: A research study in the Netherlands showed that general ultrasound (US) screening was cost-effective in the detection of developmental dysplasia of the hip (DDH). This study was followed by a pilot implementation study. Part of this pilot implementation study is to investigate whether professionals of the infant health care (IHC) system, with no previous US experience, would be able to perform US of the hip. OBJECTIVE: This study looks at health care worker ability to classify US images into a modified Graf system. MATERIALS AND METHODS: After theoretical and practical training, seven nurses and physicians of the participating IHC centers reported their findings on sonographic images of 80 children. This was repeated five months later. From the two evaluation moments the intraobserver agreement and the interobserver agreement was determined. RESULTS: The average estimated interobserver Cohen's kappa for both sessions was for nurses 0.6 and for physicians 0.5. The second evaluation showed a decrease from an average of 4.3% missed cases per screener to 2.3% and an increase of an average of 5% false positives per screener to 9.1%. CONCLUSION: The inter- and intra-observer agreement is comparable to similar studies in which the participants had a professional background in US examination. The level of agreement of the trainees in the perspective of the screening process was considered sufficient for the pilot implementation project.


Assuntos
Educação/normas , Luxação Congênita de Quadril/diagnóstico por imagem , Serviços Preventivos de Saúde/métodos , Criança , Educação Médica , Educação em Enfermagem , Humanos , Recém-Nascido , Triagem Neonatal , Países Baixos , Saúde da População Rural , Ultrassonografia , Saúde da População Urbana
17.
Chest ; 138(2): 371-9, 2010 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-20299624

RESUMO

BACKGROUND: The prevalence and severity of structural lung disease in children with common variable immunodeficiency (CVID) disorders is not well known, and a dedicated CT scanning protocol and CT scan scoring system have not been described in this category. METHODS: This was a cohort study of 54 children (34 CVID, 20 CVID-like disorder) in a stable condition who underwent volumetric inspiratory and end-expiratory CT scans. Scans were scored for airway abnormalities, interstitial and parenchymal lung disease, and lymphadenopathy using a newly developed CT scan scoring system. Scores were normalized to a 0% to 100% scale. Observer agreement was assessed using an intraclass correlation coefficient (Ri). Prevalence and severity of CT scan abnormalities were calculated. RESULTS: Structural lung disease was common (85%-93%), but usually mild as reflected in the relatively low scores (bronchiectasis score 2.8% +/- 6.4%). Moderate-to-severe bronchiectasis was found in three (5%) patients. Expiratory air trapping was the most common finding, found in 71% to 80%, but often in a mild form; application of a cut off level of > 10% reduced its prevalence to 33% to 38%. In 9% to 15% of all patients, air trapping was the only abnormality. Multiple lung nodules were seen in 24% to 25% and could disappear after corticosteroid treatment. Observer agreement was moderate (Ri 0.6-0.79) to good (Ri > 0.8) for all items and the composite scores, except airway wall thickening. CONCLUSION: In children with CVID disorders, mild structural lung disease is common. Expiratory CT scans show the most frequent abnormality, air trapping. The occurrence of (silent) lung disease progression and the clinical impact of CT scans require further investigations.


Assuntos
Imunodeficiência de Variável Comum/complicações , Pneumopatias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adolescente , Criança , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pneumopatias/complicações , Pneumopatias/epidemiologia , Masculino
18.
Invest Radiol ; 44(10): 683-90, 2009 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-19724232

RESUMO

PURPOSE: To assess the value of whole-body magnetic resonance imaging (MRI), including diffusion-weighted imaging (DWI), for the initial staging of malignant lymphoma, compared with computed tomography (CT). MATERIALS AND METHODS: Thirty-one consecutive patients with newly diagnosed malignant lymphoma prospectively underwent whole-body MRI (T1-weighted and short inversion time inversion recovery [n = 31], and DWI [n = 28]) and CT. Ann Arbor stages were assigned by 1 radiologist according to whole-body MRI findings, and by another radiologist according to CT findings. Differences in staging between whole-body MRI (without and with DWI) and CT were resolved using other (imaging) studies (including 18F-fluoro-2-deoxyglucose positron emission tomography and bone marrow biopsy) and follow-up studies as reference standard. RESULTS: Staging results of whole-body MRI without DWI were equal to those of CT in 74% (23/31), higher in 26% (8/31), and lower in 0% (0/31) of patients, with correct/incorrect/unresolved overstaging relative to CT in 3, 2, and 2 patients, respectively, and incorrect staging of both modalities in 1 patient. Staging results of whole-body MRI with DWI were equal to those of CT in 75% (21/28), higher in 25% (7/28), and lower in 0% (0/28) of patients, with correct/incorrect overstaging relative to CT in 6 and 1 patient(s), respectively. CONCLUSION: Our results suggest that initial staging of malignant lymphoma using whole-body MRI (without DWI and with DWI) equals staging using CT in the majority of patients, whereas whole-body MRI never understaged relative to CT. Furthermore, whole-body MRI mostly correctly overstaged relative to CT, with a possible advantage of using DWI.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Linfoma/diagnóstico , Tomografia Computadorizada por Raios X/métodos , Imagem Corporal Total/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
19.
Ann Intern Med ; 150(12): 840-8, W150-1, 2009 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-19414832

RESUMO

BACKGROUND: Little is known about the efficacy and safety of renal artery stenting in patients with atherosclerotic renal artery stenosis (ARAS) and impaired renal function. OBJECTIVE: To determine the efficacy and safety of stent placement in patients with ARAS and impaired renal function. DESIGN: Randomized clinical trial. Randomization was centralized and computer generated, and allocation was assigned by e-mail. Patients, providers, and persons who assessed outcomes were not blinded to treatment assignment. SETTING: 10 European medical centers. PARTICIPANTS: 140 patients with creatinine clearance less than 80 mL/min per 1.73 m(2) and ARAS of 50% or greater. INTERVENTION: Stent placement and medical treatment (64 patients) or medical treatment only (76 patients). Medical treatment consisted of antihypertensive treatment, a statin, and aspirin. MEASUREMENTS: The primary end point was a 20% or greater decrease in creatinine clearance. Secondary end points included safety and cardiovascular morbidity and mortality. RESULTS: Forty-six of 64 patients assigned to stent placement had the procedure. Ten of the 64 patients (16%) in the stent placement group and 16 patients (22%) in the medication group reached the primary end point (hazard ratio, 0.73 [95% CI, 0.33 to 1.61]). Serious complications occurred in the stent group, including 2 procedure-related deaths (3%), 1 late death secondary to an infected hematoma, and 1 patient who required dialysis secondary to cholesterol embolism. The groups did not differ for other secondary end points. LIMITATION: Many patients were falsely identified as having renal artery stenosis greater than 50% by noninvasive imaging and did not ultimately require stenting. CONCLUSION: Stent placement with medical treatment had no clear effect on progression of impaired renal function but led to a small number of significant procedure-related complications. The study findings favor a conservative approach to patients with ARAS, focused on cardiovascular risk factor management and avoiding stenting.


Assuntos
Aterosclerose/complicações , Rim/fisiopatologia , Obstrução da Artéria Renal/fisiopatologia , Obstrução da Artéria Renal/terapia , Stents , Idoso , Anti-Hipertensivos/uso terapêutico , Aspirina/uso terapêutico , Atorvastatina , Terapia Combinada , Feminino , Ácidos Heptanoicos/uso terapêutico , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/uso terapêutico , Masculino , Pessoa de Meia-Idade , Pirróis/uso terapêutico , Artéria Renal , Obstrução da Artéria Renal/etiologia , Stents/efeitos adversos
20.
J Pediatr ; 150(4): 351-7, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17382109

RESUMO

OBJECTIVE: To investigate neurodevelopment at school age in preterm infants treated with hydrocortisone for bronchopulmonary dysplasia (BPD) in the neonatal period. STUDY DESIGN: Preterm infants (n = 226; gestational age < or = 32 weeks and/or body weight < or = 1500 grams) performed subtests of the Wechsler Intelligence Scale for Children-Revised, the Visual Motor Integration test, a 15-Word Memory Test and the Movement Assessment Battery for Children at school age. Conventional MRI of the brain was obtained. Sixty-two children who received hydrocortisone for BPD (starting dose, 5 mg/kg/day; median duration, 27.5 days) were compared with 164 nontreated neonates. RESULTS: Hydrocortisone-treated infants were younger, lighter, and sicker than their non-steroid-treated counterparts. Adjustments for gestational age, body weight, sex, mechanical ventilation, and small for gestational age were made. Adjusted mean Intelligence Quotient, Visual Motor Integration test, and memory test results were the same in the hydrocortisone-treated group and the non-steroid-treated group (99 versus 101, P = .62; 97 versus 99, P = .49, 7.9 versus 7.5, P = .42, respectively). Motor function and incidence of cerebral palsy in both groups was not different (11% versus 7%, P = .97). Occurrence of brain lesions on MRI was similar for the two groups. CONCLUSIONS: Neonatal hydrocortisone treatment for BPD had no long-term effects on neurodevelopment.


Assuntos
Anti-Inflamatórios/uso terapêutico , Displasia Broncopulmonar/tratamento farmacológico , Desenvolvimento Infantil/efeitos dos fármacos , Hidrocortisona/uso terapêutico , Sistema Nervoso/efeitos dos fármacos , Encefalopatias/diagnóstico , Criança , Cognição/efeitos dos fármacos , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Imageamento por Ressonância Magnética , Masculino , Destreza Motora/efeitos dos fármacos , Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...