Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
2.
Ann Surg Oncol ; 31(7): 4477-4486, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38523225

RESUMO

BACKGROUND: The targeted axillary dissection (TAD) procedure is used in clinically positive lymph node (cN+) breast cancer to assess whether pathological complete response (pCR) is achieved after neoadjuvant systemic therapy (NST) to decide on de-escalation of axillary lymph node dissection (ALND). In this study, we review the implementation of the TAD procedure in a large regional breast cancer center. METHODS: All TAD procedures between 2016 and 2022 were reviewed. The TAD procedure consists of marking pre-NST the largest suspected metastatic lymph node(s) using a radioactive I-125 seed. During surgery, the marked node was excised together with a sentinel node procedure. Axillary therapy (ALND, axillary radiotherapy, or nothing) recommendations were based on the amount of suspected positive axillary lymph nodes (ALNs < 4 or ≥ 4) pre-NST and if pCR was achieved after NST. RESULTS: A total of 312 TAD procedures were successfully performed in 309 patients. In 134 (43%) cases, pCR of the TAD lymph nodes were achieved. Per treatment protocol, 43 cases (14%) did not receive any axillary treatment, 218 cases (70%) received adjuvant axillary radiotherapy, and 51 cases (16%) underwent an ALND. During a median follow-up of 2.8 years, 46 patients (14%) developed recurrence, of which 11 patients (3.5%) had axillary recurrence. CONCLUSIONS: Introduction of the TAD procedure has resulted in a reduction of 84% of previously indicated ALNDs. Moreover, 18% of cases did not receive adjuvant axillary radiotherapy. These data show that implementation of de-escalation axillary treatment with the TAD procedure appeared to be successful.


Assuntos
Axila , Neoplasias da Mama , Excisão de Linfonodo , Humanos , Neoplasias da Mama/patologia , Neoplasias da Mama/cirurgia , Feminino , Excisão de Linfonodo/métodos , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Idoso , Seguimentos , Metástase Linfática , Terapia Neoadjuvante , Biópsia de Linfonodo Sentinela/métodos , Linfonodos/patologia , Linfonodos/cirurgia , Prognóstico , Idoso de 80 Anos ou mais , Radioterapia Adjuvante , Carcinoma Ductal de Mama/cirurgia , Carcinoma Ductal de Mama/patologia
3.
Breast Cancer Res Treat ; 185(2): 441-451, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33073303

RESUMO

PURPOSE: The extended role of breast-conserving surgery (BCS) in the neoadjuvant setting may raise concerns on the oncologic safety of BCS compared to mastectomy. This study compared long-term outcomes after neoadjuvant chemotherapy (NAC) between patients treated with BCS and mastectomy. METHODS: All breast cancer patients treated with NAC from 2008 until 2017 at the Amphia Hospital (the Netherlands) were included. Disease-free and overall survival were compared between BCS and mastectomy with survival functions. Multivariable Cox proportional hazard regression was performed to determine prognostic variables for disease-free survival. RESULTS: 561 of 612 patients treated with NAC were eligible: 362 (64.5%) with BCS and 199 (35.5%) with mastectomy. Median follow-up was 6.8 years (0.9-11.9). Mastectomy patients had larger tumours and more frequently node-positive or lobular cancer. Unadjusted five-year disease-free survival was 90.9% for BCS versus 82.9% for mastectomy (p = .004). Unadjusted five-year overall survival was 95.3% and 85.9% (p < .001), respectively. In multivariable analysis, clinical T4 (cT4) (HR 3.336, 95% CI 1.214-9.165, p = .019) and triple negative disease (HR 5.946, 95% CI 2.703-13.081, p < .001) were negative predictors and pathologic complete response of the breast (HR 0.467, 95% CI 0.238-0.918, p = .027) and axilla (HR 0.332, 95% CI 0.193-0.572, p = .001) were positive predictors for disease-free survival. Mastectomy versus BCS was not a significant predictor for disease-free survival when adjusted for the former variables (unadjusted HR 2.13 (95%CI: 1.4-3.24), adjusted HR 1.31 (95%CI: 0.81-2.13)). In the BCS group, disease-free and overall survival did not differ significantly between cT1, cT2 or cT3 tumours. CONCLUSION: BCS does not impair disease-free and overall survival in patients treated with NAC. Tumour biology and treatment response are significant prognostic indicators.


Assuntos
Neoplasias da Mama , Mastectomia Segmentar , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/cirurgia , Estudos de Coortes , Intervalo Livre de Doença , Feminino , Humanos , Mastectomia , Terapia Neoadjuvante , Estadiamento de Neoplasias , Países Baixos/epidemiologia , Estudos Retrospectivos
4.
Neuromodulation ; 23(5): 605-612, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30974021

RESUMO

BACKGROUND: Clinical research suggests that a novel spinal cord stimulation (SCS) waveform, known as Burst-SCS, specifically targets cognitive-motivational aspects of pain. The objective of the present study was to assess the cognitive-motivational aspects of Tonic- and Burst SCS-induced pain relief, by means of exit latency in the mechanical conflict-avoidance system (MCAS), in a rat model of chronic neuropathic pain. METHODS: Exit latency on the MCAS operant testing setup was evaluated at various probe heights for rats (n = 26) with chronic neuropathic pain induced by a partial sciatic nerve ligation (PSNL). Von Frey paw withdrawal analysis was performed to assess mechanical hypersensitivity. In a second experiment (n = 12), the behavioral effect of Tonic SCS or biphasic Burst SCS on both Von Frey analysis and MCAS exit latency was assessed. RESULTS: Burst SCS exit latencies differed significantly from Tonic SCS exit latencies at 4 mm probe height (3.8 vs. 5.8 sec, respectively; p < 0.01) and 5 mm probe height (3.2 vs. 5.4 sec respectively; p < 0.05). This difference was not detected with reflex-based Von Frey testing (Tonic-SCS vs. Burst-SCS at 30 min stimulation: p = 0.73, and at 60 min stimulation; p = 0.42). CONCLUSIONS: Testing of MCAS exit latency allows for detection of cognitive-motivational pain relieving aspects induced by either Tonic- or Burst-SCS in treatment of chronic neuropathic rats. Our behavioral findings strongly suggest that Burst-SCS specifically affects, much more than Tonic-SCS, the processing of cognitive-motivational aspects of pain.


Assuntos
Cognição , Motivação , Neuralgia , Estimulação da Medula Espinal , Animais , Aprendizagem da Esquiva , Masculino , Neuralgia/terapia , Ratos , Ratos Sprague-Dawley , Nervo Isquiático , Medula Espinal
5.
Ned Tijdschr Geneeskd ; 1632019 04 11.
Artigo em Holandês | MEDLINE | ID: mdl-31050268

RESUMO

The general prevalence of perforated peptic ulcers is decreasing and they are, therefore, more likely to be missed. In our hospital, Eastern European migrants are overrepresented in the population of patients with perforated gastric peptic ulcers; due to a higher prevalence of Helicobacter pylori in Eastern Europe, they have a higher chance of developing gastric peptic ulcers than patients of Dutch origin. Treatment is hampered by the language barrier and low compliance rates, with patients often leaving hospital against medical advice and not showing up for follow-up appointments. These patients should, therefore, be informed by an interpreter, so that they are well educated about the disease and its treatment. Furthermore, we advise determination of the presence of H. pylori in these patients either during or directly after surgery, and, if necessary, empirical eradication of the bacteria.


Assuntos
Úlcera Péptica Perfurada/etnologia , Úlcera Gástrica/etnologia , Migrantes , Europa (Continente)/epidemiologia , Feminino , Infecções por Helicobacter/complicações , Infecções por Helicobacter/etnologia , Humanos , Masculino , Pessoa de Meia-Idade , Úlcera Péptica Perfurada/etiologia , Prevalência , Úlcera Gástrica/etiologia
6.
Neuromodulation ; 21(5): 472-479, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29522270

RESUMO

OBJECTIVES: This study utilizes a model of long-term spinal cord stimulation (SCS) in experimental painful diabetic polyneuropathy (PDPN) to investigate the behavioral response during and after four weeks of SCS (12 hours/day). Second, we investigated the effect of long-term SCS on peripheral cutaneous blood perfusion in experimental PDPN. METHODS: Mechanical sensitivity was assessed in streptozotocin induced diabetic rats (n = 50) with von Frey analysis. Hypersensitive rats (n = 24) were implanted with an internal SCS battery, coupled to an SCS electrode covering spinal levels L2-L5. The effects of four weeks of daily conventional SCS for 12 hours (n = 12) or Sham SCS (n = 12) were evaluated with von Frey assessment, and laser Doppler imaging (LDI). RESULTS: Average paw withdrawal thresholds (PWT) increased during long-term SCS in the SCS group, in contrast to a decrease in the Sham group (Sham vs. SCS; p = 0.029). Twenty-four hours after long-term SCS average PWT remained higher in the SCS group. Furthermore, the SCS group showed a higher cutaneous blood perfusion during long-term SCS compared to the Sham group (Sham vs. SCS; p = 0.048). Forty-eight hours after long-term SCS, no differences in skin perfusion were observed. DISCUSSION: We demonstrated that long-term SCS results in decreased baseline mechanical hypersensitivity and results in increased peripheral blood perfusion during stimulation in a rat model of PDPN. Together, these findings indicate that long-term SCS results in modulation of the physiological circuitry related to the nociceptive system in addition to symptomatic treatment of painful symptoms.


Assuntos
Diabetes Mellitus Experimental/complicações , Hiperalgesia/etiologia , Hiperalgesia/terapia , Limiar da Dor/fisiologia , Pele/irrigação sanguínea , Estimulação da Medula Espinal/métodos , Análise de Variância , Animais , Velocidade do Fluxo Sanguíneo/fisiologia , Glicemia/efeitos dos fármacos , Glicemia/fisiologia , Diabetes Mellitus Experimental/terapia , Modelos Animais de Doenças , Fluxometria por Laser-Doppler , Masculino , Medição da Dor , Ratos , Ratos Sprague-Dawley , Fatores de Tempo
7.
Diabetes Care ; 41(1): 32-38, 2018 01.
Artigo em Inglês | MEDLINE | ID: mdl-29109298

RESUMO

OBJECTIVE: Evidence from prospective studies for long-term treatment efficacy of spinal cord stimulation (SCS) in painful diabetic peripheral neuropathy (PDPN) is not available. We report prospective data on the effect of SCS on pain ratings, treatment success and failure, and complications during a 5-year follow-up in patients with PDPN. RESEARCH DESIGN AND METHODS: Patients with PDPN (n = 48) were included in this prospective multicenter study. The Michigan Diabetic Neuropathy Score (MDNS) was used to assess the severity of neuropathy. Numerical rating scale (NRS) score for pain, Patient's Global Impression of Change (PGIC), and treatment success (50% reduction of NRS score or significant PGIC) during 5 years of follow-up were evaluated. Complications of SCS were reported, and associations between baseline characteristics and SCS trial success or failure during a 5-year follow-up were investigated by using survival analyses. RESULTS: Treatment success was observed in 55% of patients after 5 years. Median duration of SCS treatment was 60 months (minimum 1 month, maximum 60 months), and 80% of patients with a permanent implant still used their SCS device after 5 years. Higher MDNS was associated with treatment failure during the 5-year follow-up (hazard ratio 3.9 [95% CI 1.3-11.6]; P = 0.014). CONCLUSIONS: SCS is successful in reducing chronic pain symptoms in the lower extremities of patients with PDPN up to 5 years after initiation of treatment. Furthermore, 80% of patients with PDPN still use their SCS device after 5 years. Moreover, the severity of neuropathy is associated with a higher chance of long-term treatment failure during a 5-year follow-up.


Assuntos
Neuropatias Diabéticas/diagnóstico , Neuropatias Diabéticas/terapia , Estimulação da Medula Espinal/efeitos adversos , Idoso , Dor Crônica , Estudos Transversais , Neuropatias Diabéticas/etiologia , Feminino , Seguimentos , Hemoglobinas Glicadas/metabolismo , Humanos , Masculino , Michigan , Pessoa de Meia-Idade , Manejo da Dor , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento
8.
J Biomech ; 64: 120-130, 2017 11 07.
Artigo em Inglês | MEDLINE | ID: mdl-29031524

RESUMO

The pelvis functions to transmit upper body loads to the lower limbs and is critical in human locomotion. Semi-automated, landmark-based finite element (FE) morphing and mapping techniques eliminate the need for segmentation and have shown to accelerate the generation of multiple specimen-specific pelvic FE models to enable the study of pelvic mechanical behaviour. The purpose of this research was to produce an experimentally validated cohort of specimen-specific FE models of the human pelvis and to use this cohort to analyze pelvic strain patterns during gait. Using an initially segmented specimen-specific pelvic FE model asa source model, four more specimen-specific pelvic FE models were generated from target clinical CT scans using landmark-based morphing and mapping techniques. FE strains from the five models were compared to the experimental strains obtained from cadaveric testing via linear regression analysis, (R2 values ranging from 0.70 to 0.93). Inter-specimen variability in FE strain distributions was seen among the five specimen-specific pelvic FE models. The validated cohort of specimen-specific pelvic FE models was utilized to examine pelvic strains at different phases of the gait cycle. Each validated specimen-specific FE model was reconfigured into gait cycle phases representing heel-strike/heel-off and midstance/midswing. No significant difference was found in the double-leg stance and heel-strike/heel-off models (p=0.40). A trend was observed between double-leg stance and midstance/midswing models (p=0.07), and a significant difference was found between heel-strike/heel-off models and midstance/midswing models (p=0.02). Significant differences were also found in comparing right vs. left models (heel-strike/heel-off p=0.14, midstance/midswing p=0.04).


Assuntos
Análise de Elementos Finitos , Marcha , Pelve/fisiologia , Estresse Mecânico , Tomografia Computadorizada por Raios X , Fenômenos Biomecânicos , Estudos de Coortes , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Biológicos , Pelve/diagnóstico por imagem
10.
J Biomech ; 48(6): 1125-32, 2015 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-25680299

RESUMO

Current methods for the development of pelvic finite element (FE) models generally are based upon specimen specific computed tomography (CT) data. This approach has traditionally required segmentation of CT data sets, which is time consuming and necessitates high levels of user intervention due to the complex pelvic anatomy. The purpose of this research was to develop and assess CT landmark-based semi-automated mesh morphing and mapping techniques to aid the generation and mechanical analysis of specimen-specific FE models of the pelvis without the need for segmentation. A specimen-specific pelvic FE model (source) was created using traditional segmentation methods and morphed onto a CT scan of a different (target) pelvis using a landmark-based method. The morphed model was then refined through mesh mapping by moving the nodes to the bone boundary. A second target model was created using traditional segmentation techniques. CT intensity based material properties were assigned to the morphed/mapped model and to the traditionally segmented target models. Models were analyzed to evaluate their geometric concurrency and strain patterns. Strains generated in a double-leg stance configuration were compared to experimental strain gauge data generated from the same target cadaver pelvis. CT landmark-based morphing and mapping techniques were efficiently applied to create a geometrically multifaceted specimen-specific pelvic FE model, which was similar to the traditionally segmented target model and better replicated the experimental strain results (R(2)=0.873). This study has shown that mesh morphing and mapping represents an efficient validated approach for pelvic FE model generation without the need for segmentation.


Assuntos
Pelve/diagnóstico por imagem , Fenômenos Biomecânicos , Módulo de Elasticidade , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Modelos Anatômicos , Tomografia Computadorizada por Raios X/métodos
11.
J Neurosci ; 34(42): 13963-75, 2014 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-25319693

RESUMO

It is well established that the cholesterol-transporter apolipoprotein ε (APOE) genotype is associated with the risk of developing neurodegenerative diseases. Recently, brain functional connectivity (FC) in apoE-ε4 carriers has been investigated by means of resting-state fMRI, showing a marked differentiation in several functional networks at different ages compared with carriers of other apoE isoforms. The causes of such hampered FC are not understood. We hypothesize that vascular function and synaptic repair processes, which are both impaired in carriers of ε4, are the major contributors to the loss of FC during aging. To test this hypothesis, we integrated several different MRI techniques with immunohistochemistry and investigated FC changes in relation with perfusion, diffusion, and synaptic density in apoE4 and apoE-knock-out (KO) mice at 12 (adult) and 18 months of age. Compared with wild-type mice, we detected FC deficits in both adult and old apoE4 and apoE-KO mice. In apoE4 mice, these changes occurred concomitant with increased mean diffusivity in the hippocampus, whereas perfusion deficits appear only later in life, together with reduced postsynaptic density levels. Instead, in apoE-KO mice FC deficits were mirrored by strongly reduced brain perfusion since adulthood. In conclusion, we provide new evidence for a relation between apoE and brain connectivity, possibly mediated by vascular risk factors and by the efficiency of APOE as synaptic modulator in the brain. Our results show that multimodal MR neuroimaging is an excellent tool to assess brain function and to investigate early neuropathology and aging effects in translational research.


Assuntos
Envelhecimento/metabolismo , Apolipoproteína E4/deficiência , Encéfalo/metabolismo , Rede Nervosa/metabolismo , Descanso/fisiologia , Envelhecimento/patologia , Animais , Apolipoproteínas E/deficiência , Encéfalo/patologia , Células Cultivadas , Feminino , Humanos , Masculino , Camundongos , Camundongos da Linhagem 129 , Camundongos Endogâmicos C57BL , Camundongos Knockout , Camundongos Transgênicos , Rede Nervosa/patologia
12.
Comput Aided Surg ; 19(1-3): 48-56, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24720491

RESUMO

OBJECTIVE: This study presents and evaluates a semi-automated algorithm for quantifying malalignment in complex femoral shaft fractures from a single intraoperative cone-beam CT (CBCT) image of the fractured limb. METHODS: CBCT images were acquired of complex comminuted diaphyseal fractures created in 9 cadaveric femora (27 cases). Scans were segmented using intensity-based thresholding, yielding image stacks of the proximal, distal and comminuted bone. Semi-deformable and rigid affine registrations to an intact femur atlas (synthetic or cadaveric-based) were performed to transform the distal fragment to its neutral alignment. Leg length was calculated from the volume of bone within the comminution fragment. The transformations were compared to the physical input malalignments. RESULTS: Using the synthetic atlas, translations were within 1.71 ± 1.08 mm (medial/lateral) and 2.24 ± 2.11 mm (anterior/posterior). The varus/valgus, flexion/extension and periaxial rotation errors were 3.45 ± 2.6°, 1.86 ± 1.5° and 3.4 ± 2.0°, respectively. The cadaveric-based atlas yielded similar results in medial/lateral and anterior/posterior translation (1.73 ± 1.28 mm and 2.15 ± 2.13 mm, respectively). Varus/valgus, flexion/extension and periaxial rotation errors were 2.3 ± 1.3°, 2.0 ± 1.6° and 3.4 ± 2.0°, respectively. Leg length errors were 1.41 ± 1.01 mm (synthetic) and 1.26 ± 0.94 mm (cadaveric). The cadaveric model demonstrated a small improvement in flexion/extension and the synthetic atlas performed slightly faster (6 min 24 s ± 50 s versus 8 min 42 s ± 2 min 25 s). CONCLUSIONS: This atlas-based algorithm quantified malalignment in complex femoral shaft fractures within clinical tolerances from a single CBCT image of the fractured limb.


Assuntos
Algoritmos , Fraturas do Fêmur/diagnóstico por imagem , Fraturas Mal-Unidas/diagnóstico por imagem , Imageamento Tridimensional , Cadáver , Tomografia Computadorizada de Feixe Cônico , Diáfises/diagnóstico por imagem , Diáfises/lesões , Fraturas Cominutivas/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade
13.
Artigo em Inglês | MEDLINE | ID: mdl-22452517

RESUMO

The reliability of patient-specific finite element (FE) modelling is dependent on the ability to provide repeatable analyses. Differences of inter-operator generated grids can produce variability in strain and stress readings at a desired location, which are magnified at the surface of the model as a result of the partial volume edge effects (PVEEs). In this study, a new approach is introduced based on an in-house developed algorithm which adjusts the location of the model's surface nodes to a consistent predefined threshold Hounsfield unit value. Three cadaveric human femora specimens were CT scanned, and surface models were created after a semi-automatic segmentation by three different experienced operators. A FE analysis was conducted for each model, with and without applying the surface-adjustment algorithm (a total of 18 models), implementing identical boundary conditions. Maximum principal strain and stress and spatial coordinates were probed at six equivalent surface nodes from the six generated models for each of the three specimens at locations commonly utilised for experimental strain guage measurement validation. A Wilcoxon signed-ranks test was conducted to determine inter-operator variability and the impact of the PVEE-adjustment algorithm. The average inter-operator difference in stress values was significantly reduced after applying the adjustment algorithm (before: 3.32 ± 4.35 MPa, after: 1.47 ± 1.77 MPa, p = 0.025). Strain values were found to be less sensitive to inter-operative variability (p = 0.286). In summary, the new approach as presented in this study may provide a means to improve the repeatability of subject-specific FE models of bone obtained from CT data.


Assuntos
Algoritmos , Fêmur/diagnóstico por imagem , Análise de Elementos Finitos , Tomografia Computadorizada por Raios X , Humanos , Modelos Biológicos , Reprodutibilidade dos Testes , Estresse Mecânico
14.
J Orthop Res ; 31(10): 1653-60, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23737260

RESUMO

Micro-finite element (µFE) modeling has shown promise in evaluating the structural integrity of trabecular bone. Histologic microcrack analyses have been compared to µFE models of trabecular bone cores to demonstrate the potential of this technique. To date this has not been achieved in whole bone structures, and comparisons of histologic microcrack and µFE results have been limited due to challenges in alignment of 2D sections with 3D data sets. The goal of this study was to ascertain if image registration can facilitate determination of a relationship between stresses and strains generated from µFE models of whole vertebrae and histologically identified microdamage. µFE models of three whole vertebrae, stained sequentially with calcein and fuchsin, were generated with accurate integration of element sets representing the histologic sections based on volumetric image registration. Displacement boundary conditions were applied to the µFE models based on registration of loaded and unloaded µCT images. Histologically labeled damaged regions were found to have significantly higher von Mises stresses and principle strains in the µFE models, as compared to undamaged regions. This work provides a new robust method for generating and histologically validating µFE models of whole bones that can represent trabecular damage resulting from complex physiologic loading.


Assuntos
Análise de Elementos Finitos , Modelos Biológicos , Doenças da Coluna Vertebral/fisiopatologia , Coluna Vertebral/fisiopatologia , Animais , Fenômenos Biomecânicos/fisiologia , Processamento de Imagem Assistida por Computador , Ratos , Ratos Wistar , Doenças da Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/diagnóstico por imagem , Estresse Mecânico , Suporte de Carga/fisiologia , Microtomografia por Raio-X
15.
Int J Numer Method Biomed Eng ; 29(1): 104-13, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23293071

RESUMO

Robust generation of pelvic finite element models is necessary to understand the variation in mechanical behaviour resulting from differences in gender, aging, disease and injury. The objective of this study was to apply and evaluate mesh morphing and mapping techniques to facilitate the creation and structural analysis of specimen-specific finite element (FE) models of the pelvis. A specimen-specific pelvic FE model (source mesh) was generated following a traditional user-intensive meshing scheme. The source mesh was morphed onto a computed tomography scan generated target surface of a second pelvis using a landmarked-based approach, in which exterior source nodes were shifted to target surface vertices, while constrained along a normal. A second copy of the morphed model was further refined through mesh mapping, in which surface nodes of the initial morphed model were selected in patches and remapped onto the surfaces of the target model. Computed tomography intensity based material properties were assigned to each model. The source, target, morphed and mapped models were analyzed under axial compression using linear static FE analysis and their strain distributions evaluated. Morphing and mapping techniques were effectively applied to generate good quality geometrically complex specimen-specific pelvic FE models. Mapping significantly improved strain concurrence with the target pelvis FE model.


Assuntos
Força Compressiva/fisiologia , Modelos Biológicos , Pelve/fisiologia , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Pessoa de Meia-Idade , Pelve/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos
16.
Med Eng Phys ; 35(7): 1028-36, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23141212

RESUMO

Accurate alignment of femoral shaft fractures treated with intramedullary nailing remains a challenge for orthopaedic surgeons. The aim of this study is to develop and validate a cone-beam CT-based, semi-automated algorithm to quantify the malalignment in six degrees of freedom (6DOF) using a surface matching and principal axes-based approach. Complex comminuted diaphyseal fractures were created in nine cadaveric femora and cone-beam CT images were acquired (27 cases total). Scans were cropped and segmented using intensity-based thresholding, producing superior, inferior and comminution volumes. Cylinders were fit to estimate the long axes of the superior and inferior fragments. The angle and distance between the two cylindrical axes were calculated to determine flexion/extension and varus/valgus angulation and medial/lateral and anterior/posterior translations, respectively. Both surfaces were unwrapped about the cylindrical axes. Three methods of matching the unwrapped surface for determination of periaxial rotation were compared based on minimizing the distance between features. The calculated corrections were compared to the input malalignment conditions. All 6DOF were calculated to within current clinical tolerances for all but two cases. This algorithm yielded accurate quantification of malalignment of femoral shaft fractures for fracture gaps up to 60 mm, based on a single CBCT image of the fractured limb.


Assuntos
Algoritmos , Fraturas do Fêmur/cirurgia , Fixação Interna de Fraturas/métodos , Automação , Tomografia Computadorizada de Feixe Cônico , Fraturas do Fêmur/diagnóstico por imagem , Fêmur/diagnóstico por imagem , Fêmur/lesões , Fêmur/cirurgia , Humanos , Propriedades de Superfície
17.
J Biomech ; 45(14): 2342-8, 2012 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-22858318

RESUMO

This study compares the ability of µCT image-based registration, 2D structural rigidity analyses and multimodal continuum-level finite element (FE) modeling in evaluating the mechanical stability of healthy, osteolytic, and mixed osteolytic/osteoblastic metastatically involved rat vertebrae. µMR and µCT images (loaded and unloaded) were acquired of lumbar spinal motion segments from 15rnu/rnu rats (five per group). Strains were calculated based on image registration of the loaded and unloaded µCT images and via analysis of FE models created from the µCT and µMR data. Predicted yield load was also calculated through 2D structural rigidity analysis of the axial unloaded µCT slices. Measures from the three techniques were compared to experimental yield loads. The ability of these methods to predict experimental yield loads were evaluated and image registration and FE calculated strains were directly compared. Quantitatively for all samples, only limited weak correlations were found between the image-based measures and experimental yield load. In comparison to the experimental yield load, we observed a trend toward a weak negative correlation with median strain calculated using the image-based strain measurement algorithm (r=-0.405, p=0.067), weak significant correlations (p<0.05) with FE based median and 10th percentile strain values (r=-0.454, -0.637, respectively), and a trend toward a weak significant correlation with FE based mean strain (r=-0.366, p=0.09). Individual group analyses, however, yielded more and stronger correlations with experimental results. Considering the image-based strain measurement algorithm we observed moderate significant correlations with experimental yield load (p<0.05) in the osteolytic group for mean and median strain values (r=-0.840, -0.832, respectively), and in the healthy group for median strain values (r=-0.809). Considering the rigidity-based predicted yield load, we observed a strong significant correlation with the experimental yield load in the mixed osteolytic/osteoblastic group (r=0.946) and trend toward a moderate correlation with the experimental yield load in the osteolytic group (r=0.788). Qualitatively, strain patterns in the vertebral bodies generated using image registration and FEA were well matched, yet quantitatively a significant correlation was found only between mean strains in the healthy group (r=0.934). Large structural differences in metastatic vertebrae and the complexity of motion segment loading may have led to varied modes of failure. Improvements in load characterization, material properties assignments and resolution are necessary to yield a more generalized ability for image-based registration, structural rigidity and FE methods to accurately represent stability in healthy and pathologic scenarios.


Assuntos
Neoplasias Ósseas , Movimento , Osteólise , Coluna Vertebral , Estresse Fisiológico , Microtomografia por Raio-X , Animais , Neoplasias Ósseas/diagnóstico por imagem , Neoplasias Ósseas/fisiopatologia , Neoplasias Ósseas/secundário , Metástase Neoplásica , Osteólise/diagnóstico por imagem , Osteólise/fisiopatologia , Ratos , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/fisiopatologia , Suporte de Carga
18.
Int J Numer Method Biomed Eng ; 28(8): 904-13, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25099570

RESUMO

Robust generation of pelvic finite element models is necessary to understand variation in mechanical behaviour resulting from differences in gender, aging, disease and injury. The objective of this study was to apply and evaluate mesh morphing and mapping techniques to facilitate the creation and structural analysis of specimen-specific finite element (FE) models of the pelvis. A specimen-specific pelvic FE model (source mesh) was generated following a traditional user-intensive meshing scheme. The source mesh was morphed onto a computed tomography scan generated target surface of a second pelvis using a landmarked-based approach, in which exterior source nodes were shifted to target surface vertices, while constrained along a normal. A second copy of the morphed model was further refined through mesh mapping, in which surface nodes of the initial morphed model were selected in patches and remapped onto the surfaces of the target model. Computed tomography intensity-based material properties were assigned to each model. The source, target, morphed and mapped models were analyzed under axial compression using linear static FE analysis, and their strain distributions were evaluated. Morphing and mapping techniques were effectively applied to generate good quality and geometrically complex specimen-specific pelvic FE models. Mapping significantly improved strain concurrence with the target pelvis FE model.


Assuntos
Força Compressiva/fisiologia , Pelve/fisiologia , Simulação por Computador , Feminino , Análise de Elementos Finitos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Modelagem Computacional Específica para o Paciente , Pelve/diagnóstico por imagem , Estresse Mecânico , Tomografia Computadorizada por Raios X/métodos
19.
J Biomech ; 43(14): 2684-8, 2010 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-20684957

RESUMO

Computational patient-specific modeling has the potential to yield powerful information for selection and planning of fracture treatments if it can be developed to yield results that are rapid, focused and coherent from a clinical perspective. In this study we introduce the utilization of a principal strain fixation ratio measure (SR) defined as the ratio of principal strains that develop in a fixated bone relative to the principal strains that develop in the same bone in an intact state. The SR field output variable is theoretically independent of load amplitude and also has a direct clinical interpretation with SR<1-a representing stress shielding and SR>1+b representing overstressed bone. A combined experimental and numerical study was performed with cadaveric proximal femora (n=6) intact and following fracture fixation to quantify the performance of the SR variable in terms of accuracy and sensitivity to uncertainties in density-elasticity relationships and load amplitude as model input variables. For a given axial compressive force the SR field output variable was found to be less sensitive to changes in density-elasticity relationships and the response function to be more accurate than strain values themselves; errors were reduced by 44% on comparing SR with strain in the fixated model. In addition, the experimental data confirmed the assumption that the SR values behave independent of load amplitude. The load independent behavior of SR and its direct clinical interpretation may ultimately provide an appropriate and easily understood comparative computational measure to choose between patient specific fracture fixation alternatives.


Assuntos
Fraturas do Fêmur/fisiopatologia , Fraturas do Fêmur/cirurgia , Fixação de Fratura , Modelos Biológicos , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Simulação por Computador , Elasticidade , Feminino , Análise de Elementos Finitos , Fixação de Fratura/estatística & dados numéricos , Humanos , Técnicas In Vitro , Pessoa de Meia-Idade , Estresse Mecânico
20.
J Appl Biomech ; 26(4): 526-30, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21245515

RESUMO

Computer assisted surgical interventions and research in joint kinematics rely heavily on the accurate registration of three-dimensional bone surface models reconstructed from various imaging technologies. Anomalous results were seen in a kinematic study of carpal bones using a principal axes alignment approach for the registration. The study was repeated using an iterative closest point algorithm, which is more accurate, but also more demanding to apply. The principal axes method showed errors between 0.35 mm and 0.49 mm for the scaphoid, and between 0.40 mm and 1.22 mm for the pisiform. The iterative closest point method produced errors of less than 0.4 mm. These results show that while the principal axes method approached the accuracy of the iterative closest point algorithm in asymmetrical bones, there were more pronounced errors in bones with some symmetry. Principal axes registration for carpal bones should be avoided.


Assuntos
Ossos do Carpo/fisiologia , Imageamento Tridimensional/métodos , Movimento/fisiologia , Algoritmos , Fenômenos Biomecânicos , Cadáver , Ossos do Carpo/diagnóstico por imagem , Humanos , Modelos Biológicos , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...