Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Br J Clin Pharmacol ; 84(10): 2311-2316, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29908071

RESUMO

AIMS: Flucloxacillin dosing may be guided by measurement of its total plasma concentrations. Flucloxacillin is highly protein bound with fraction unbound in plasma (fu ) of around 0.04 in healthy individuals. The utility of measuring unbound flucloxacillin concentrations for patients outside the intensive care unit (ICU) is not established. We aimed to compare flucloxacillin fu in non-ICU hospitalised patients against healthy volunteers, and to examine the performance of a published model for predicting unbound concentrations, using total flucloxacillin and plasma albumin concentrations. METHODS: Data from 12 healthy volunteers (248 samples) and 47 hospitalized patients (61 samples) were examined. Plasma flucloxacillin concentrations were measured using a validated liquid chromatography-tandem mass spectrometry method. Flucloxacillin fu for the two groups was compared using a generalized estimating equation model to account for clustered observations. The performance of the single protein binding site prediction model in hospitalized patients was compared with measured unbound concentrations using Bland-Altman plots. RESULTS: The median (range) flucloxacillin fu for healthy (median albumin 45 g l-1 ) and hospitalized individuals (median albumin 30 g l-1 ) were 0.04 (0.02-0.07) and 0.10 (0.05-0.37), respectively (P < 0.0001). The prediction model underpredicted unbound flucloxacillin concentrations with a mean bias (95% limits of agreement) of -54% (-137%, +30%). CONCLUSIONS: The flucloxacillin fu values observed in our cohort of hospitalized patients had a wide range and were greater than those of healthy individuals. Unbound flucloxacillin plasma concentrations were predicted poorly by the model. Instead, unbound concentrations should be measured to guide dosing.


Assuntos
Antibacterianos/farmacocinética , Bacteriemia/tratamento farmacológico , Floxacilina/farmacocinética , Modelos Biológicos , Infecções Estafilocócicas/tratamento farmacológico , Adulto , Idoso , Idoso de 80 Anos ou mais , Antibacterianos/administração & dosagem , Antibacterianos/sangue , Bacteriemia/microbiologia , Cromatografia Líquida de Alta Pressão/métodos , Relação Dose-Resposta a Droga , Feminino , Floxacilina/administração & dosagem , Floxacilina/sangue , Voluntários Saudáveis , Hospitalização , Humanos , Masculino , Pessoa de Meia-Idade , Plasma/química , Albumina Sérica Humana/análise , Infecções Estafilocócicas/sangue , Infecções Estafilocócicas/microbiologia , Staphylococcus aureus/isolamento & purificação , Espectrometria de Massas em Tandem/métodos , Adulto Jovem
2.
J Hum Lact ; 29(2): 150-3, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23439864

RESUMO

To the best of our knowledge, there have been no published studies of doxazosin transfer into human milk. In rats, milk concentrations twentyfold higher than in plasma have been reported. Based on these animal data, some references advise to avoid breastfeeding during doxazosin therapy. However, the physicochemical properties of doxazosin suggest low transfer into human milk. A 37-year-old breastfeeding woman who was administered doxazosin 4 mg daily for 2 doses was studied. Doxazosin concentrations in milk and plasma were measured by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The milk/plasma area under the concentration-time curve (AUC0-18 hours) ratio was 0.1. This finding is consistent with what could be predicted based on the physicochemical properties of doxazosin. The average and maximum milk concentrations were 2.9 and 4.2 µg/L. These values correspond to estimated relative infant doses of 0.06% and 0.09%, respectively, assuming standard infant milk intake. These values are well below the generally accepted cutoff of 10% for predicting safety during breastfeeding. A low relative infant dose of < 0.1% suggests that maternal doxazosin therapy may be compatible with breastfeeding after careful individual risk-benefit analysis.


Assuntos
Anti-Hipertensivos/farmacocinética , Doxazossina/farmacocinética , Leite Humano/química , Adulto , Anti-Hipertensivos/análise , Área Sob a Curva , Cromatografia Líquida , Doxazossina/análise , Feminino , Humanos , Espectrometria de Massas em Tandem , Fatores de Tempo
3.
Br J Clin Pharmacol ; 74(5): 797-805, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22380743

RESUMO

WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT: Hepatic drug clearance is thought to be reduced with age. However for highly protein bound drugs, which are cleared by capacity-limited metabolism, studies on total clearance have been conflicting. The hypothesis that protein binding decreases with age has been used to explain this. Warfarin is a highly protein bound drug, which is cleared by capacity-limited metabolism. There are conflicting or little data on the relationship between adult age and total and free clearance and protein binding of (R)- and (S)-warfarin. WHAT THIS STUDY ADDS: In a clinical study of 72 patients (18-89 years) on warfarin therapy, both total and free clearance of (R)-warfarin decreased with age. For (S)-warfarin there was a stronger signal of a decrease in free than total clearance. Protein binding was found not to correlate with age for (R)- and (S)-warfarin. In an ex vivo study, in which warfarin was spiked to plasma samples from 60 healthy subjects (19-87 years), no correlation between protein binding and age was found. These data support the hypothesis that hepatic drug clearance decreases with age. This should be taken into consideration when individualizing dosing, particularly in the elderly. AIMS: To test the hypothesis that the clearance (CL) of warfarin, a very highly protein bound drug with capacity-limited metabolism, decreases with age. METHODS: In a clinical study, a steady-state blood sample was taken from 72 patients (18-89 years) on routine treatment with warfarin. Concentrations of (R)- and (S)-warfarin were determined in plasma (total) and ultrafiltrate (free) by LC-MS/MS. Total and free CL and protein binding were determined and regressed against age and other covariates. In an ex vivo study, warfarin was spiked to plasma samples from 60 healthy subjects (19-87 years) and protein binding was regressed against age and other covariates. RESULTS: For (R)-warfarin a significant decrease with age was found for both total and free CL (P < 0.001). For (S)-warfarin there was a stronger signal of a decrease with age in free CL (P= 0.005) vs. total CL (P= 0.045). The decrease in CL of (R)- and (S)-warfarin was 0.3-0.5% per year. Other covariates influencing CL were lean body weight for both (R)- and (S)-warfarin and CYP2C9 genotype and blood sampling time for (S)-warfarin. Protein binding of (R)- and (S)-warfarin was not found to change significantly with age in either the clinical or the spiked samples, despite a slight decrease in albumin concentration with age. CONCLUSIONS: These data support the hypothesis that the CL of (R)- and (S)-warfarin decreases with age. More accurate information was gained when measuring free CL for (S)-warfarin. Warfarin protein binding did not change significantly with age.


Assuntos
Anticoagulantes/farmacocinética , Hidrocarboneto de Aril Hidroxilases/genética , Proteínas Sanguíneas/metabolismo , Varfarina/farmacocinética , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Coleta de Amostras Sanguíneas/métodos , Cromatografia Líquida , Citocromo P-450 CYP2C9 , Feminino , Genótipo , Humanos , Masculino , Pessoa de Meia-Idade , Ligação Proteica , Estereoisomerismo , Espectrometria de Massas em Tandem , Fatores de Tempo , Adulto Jovem
4.
Br J Clin Pharmacol ; 73(4): 619-28, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-21999196

RESUMO

WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT: A single nucleotide polymorphism in ABCB1, which encodes P-glycoprotein, has retrospectively been associated with symptoms of nortriptyline-induced postural hypotension in depressed patients. This finding needs to be replicated in independent studies before recommendations regarding pharmacogenetic testing can be made. WHAT THIS STUDY ADDS: In a prospective study of healthy volunteers homozygous for ABCB1 (1236-2677-3435, TTT/TTT or CGC/CGC), a single dose of nortriptyline was administered, plasma exposure was determined and blood pressure and heart rate were monitored during posture change. No differences between ABCB1 haplotype groups were found in plasma exposure of nortriptyline and its active metabolites, E- and Z-10-hydroxynortriptyline. The heart rate response to posture change was increased with nortriptyline, whereas there was no difference in blood pressure response. However, no differences between haplotype groups were observed except that the pre dose heart rate response to standing was greater in the TTT than CGC homozygotes. The association between ABCB1 polymorphisms and nortriptyline-induced postural hypotension found in a previous study could not be confirmed. The results raise the possibility of a predisposition in heart rate response in the TTT homozygotes rather than an effect of nortriptyline. AIMS To investigate the influence of ABCB1 (1236-2677-3435) polymorphisms on nortriptyline pharmacokinetics and nortriptyline-induced postural hypotension in healthy volunteers. METHODS: Genetic screening of 67 healthy volunteers identified eight CGC homozygotes and nine TTT homozygotes of ABCB1 (1236-2677-3435), who were administered a single dose of nortriptyline 25 mg. Plasma exposure of nortriptyline and its active metabolites, E- and Z-10-hydroxynortriptyline, was determined over 72 h. Heart rate and blood pressure responses to posture change (active standing and passive head-up tilt) were measured continuously using finger plethysmography. RESULTS: There were no differences in plasma exposure between ABCB1 haplotype groups, as the geometric mean (95% CI) AUC(0,72 h) ratios were 0.98 (0.94, 1.03), 1.02 (0.96, 1.09) and 0.95 (0.80, 1.10) for nortriptyline, E- and Z-10-hydroxynortriptyline, respectively. The pre dose heart rate response to standing was greater in the TTT than CGC homozygotes (mean (95% CI) difference 7.4 (1.5, 13.4) beats min(-1) , P = 0.02). At t(max) at 8 h post dose, nortriptyline increased the heart rate response to posture change in all subjects with mean (95% CI) Δ heart rate values of 7.4 (3.6, 11.3) beats min(-1) on active standing (P = 0.0009) and 4.8 (2.0, 7.6) beats min(-1) on head-up tilt (P = 0.002), but no difference was observed between haplotype groups. There was no difference in blood pressure response to posture change in either group. CONCLUSION: The association between ABCB1 polymorphisms and nortriptyline-induced postural hypotension found in the previous study could not be confirmed. The results raise the possibility of a predisposition in heart rate response in the TTT homozygotes rather than an effect of nortriptyline.


Assuntos
Membro 1 da Subfamília B de Cassetes de Ligação de ATP/genética , Antidepressivos Tricíclicos/farmacocinética , Pressão Sanguínea/efeitos dos fármacos , Frequência Cardíaca/genética , Hipotensão Ortostática/metabolismo , Nortriptilina/farmacocinética , Subfamília B de Transportador de Cassetes de Ligação de ATP , Membro 1 da Subfamília B de Cassetes de Ligação de ATP/efeitos dos fármacos , Adolescente , Adulto , Área Sob a Curva , Pressão Sanguínea/genética , Feminino , Haplótipos/efeitos dos fármacos , Haplótipos/genética , Humanos , Hipotensão Ortostática/induzido quimicamente , Hipotensão Ortostática/genética , Masculino , Pessoa de Meia-Idade , Linhagem , Polimorfismo de Nucleotídeo Único , Estudos Prospectivos , População Branca , Adulto Jovem
5.
Anal Bioanal Chem ; 401(7): 2187-93, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21830136

RESUMO

A sensitive LC-MS/MS assay for quantification of total and free concentrations of R- and S-warfarin in plasma was required to support clinical studies on warfarin enantiomers. Several ultrafiltration devices were evaluated for separation of free warfarin from plasma proteins. The highest precision and lowest non-specific binding was obtained for Centrifree ultrafiltration devices. R- and S-warfarin were extracted from plasma (total) and ultrafiltrate (free) by liquid-liquid extraction with methyl tert-butyl ether using d(6)-warfarin as internal standard. Mean extraction recovery was 68 ± 4%. The enantiomers were separated on a Chirobiotic V column with isocratic elution using 40% methanol and 0.03% acetic acid in water. Negative mode electrospray ionisation was used for MS/MS detection, monitoring the ion transition m/z 307/161. Calibration curves (quadratic, weighted 1/x) were fitted over the range of 20-2,000 ng/ml (r(2)≥0.995) in plasma and 0.5-20 ng/ml (r(2)≥0.998) in ultrafiltrate. The lower limit of quantification for R- and S-warfarin was 0.5 ng/ml in ultrafiltrate. Intra- and interday precision (% RSD) and bias were within 10% in all cases, and matrix effects were negligible. The assay was applied successfully to analysis of samples from clinical studies.


Assuntos
Cromatografia Líquida , Espectrometria de Massas em Tandem , Ultrafiltração , Varfarina/sangue , Calibragem , Humanos , Extração Líquido-Líquido , Padrões de Referência , Estereoisomerismo
6.
J Chromatogr B Analyt Technol Biomed Life Sci ; 879(9-10): 605-9, 2011 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-21333615

RESUMO

A rapid and simple liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed and validated for quantification of cyclizine and its main metabolite norcyclizine in human plasma. Samples were prepared by protein precipitation with acetonitrile and cinnarizine was used as internal standard (recovery >87%). The analytes were eluted from a C8 50 mm×2.0 mm analytical column using a linear gradient of methanol and 0.05% formic acid with a total analysis time of 4 min. Analytes were detected by MS/MS using electrospray ionisation in the positive mode with multiple reactions monitoring (MRM) of the precursor ion/product ion transitions 267.2/167.2 for cyclizine and 253.2/167.2 for norcyclizine. Matrix effects were negligible. Standard curves for cyclizine and norcyclizine were linear (r(2)≥0.996) over the range 2-200 ng/mL, with 2 ng/mL representing the lower limit of quantification. Relative standard deviations were <14% for intra- and inter-day precision and the accuracy was within ±8%. The assay was successfully applied to a clinical study.


Assuntos
Cromatografia Líquida/métodos , Ciclizina/análogos & derivados , Ciclizina/sangue , Espectrometria de Massas em Tandem/métodos , Cinarizina/sangue , Cinarizina/química , Ensaios Clínicos como Assunto , Ciclizina/farmacocinética , Humanos , Modelos Lineares , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...