Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Eur J Orthop Surg Traumatol ; 34(1): 599-604, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37660313

RESUMO

OBJECTIVES: To determine the association between hip capsular distension, the computed tomography (CT) capsular sign, and lipohemarthrosis as they relate to occult femoral neck fracture (FNF) in the setting of ipsilateral femoral shaft fracture (FSF). DESIGN: Retrospective comparative study. SETTING: Level 1 trauma center. PATIENTS/PARTICIPANTS: Two hundred and forty-two patients with high-energy FSF and no evidence of FNF on preoperative radiographs and pelvis CT. All patients were stabilized with non-reconstruction style nails. INTERVENTION: Pelvis CT scans were examined for hip capsular distension irrespective of the other side, differing side-to-side measurements of capsular distension (i.e., the CT capsular sign), and lipohemarthrosis. MAIN OUTCOME MEASUREMENTS: FNF was observed for on postoperative radiographs. Relative risk (RR), number needed to treat (NNT), sensitivity (SN), and specificity (SP) were determined. RESULTS: Fifty-eight patients (24.0%) had capsular distension. Forty-two patients (17.4%) had differing capsular measurements (i.e., the CT capsular sign), and 16 (6.6%) had symmetrical distension from bilateral hip effusions. Eight patients (3.3%) had lipohemarthrosis. Four FNFs (1.7%) were identified. Three patients had capsular distension, 2 had CT capsular signs, and 1 had lipohemarthrosis. The last patient had no CT abnormalities. Only capsular distension (RR = 10, CI = 1.001-90, P = 0.049; SN = 75%, SP = 77%; NNT = 22) and lipohemarthrosis (RR = 23, CI = 1.6-335, P = 0.022; SN = 50%, SP = 96%; NNT = 8) were associated with occult FNF. CONCLUSIONS: Capsular distension is associated with FNF irrespective of the contralateral hip. Preemptive stabilization using a reconstruction nail could be considered in the setting of capsular distension or lipohemarthrosis to prevent displacement of an occult FNF. LEVEL OF EVIDENCE: Diagnostic Level III.


Assuntos
Fraturas do Fêmur , Fraturas do Colo Femoral , Humanos , Estudos Retrospectivos , Fraturas do Colo Femoral/complicações , Fraturas do Colo Femoral/diagnóstico por imagem , Fraturas do Colo Femoral/cirurgia , Fraturas do Fêmur/complicações , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/cirurgia , Tomografia Computadorizada por Raios X/métodos , Radiografia
2.
J Orthop Trauma ; 31(12): 611-616, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28742789

RESUMO

OBJECTIVE: To evaluate venous thromboembolism (VTE) prophylaxis adherence and effectiveness in orthopaedic trauma patients who had vascular or radiographic studies showing deep vein thromboses or pulmonary emboli. DESIGN: Retrospective review. SETTING: A level I trauma center that independently services a 5-state region. PATIENTS: Four hundred seventy-six patients with orthopaedic trauma who underwent operative treatments for orthopaedic injuries and had symptom-driven diagnostic VTE studies. INTERVENTION: The medical records of patients treated surgically between July 2010 and March 2013 were interrogated using a technical tool that electronically captures thrombotic event data from vascular and radiologic imaging studies by natural language processing. MAIN OUTCOME MEASUREMENTS: Patients were evaluated for hospital guideline-directed VTE prophylaxis adherence with mechanical or chemical prophylaxis. Patient demographics, associated injuries, mechanism of injury, and symptoms that led to imaging for a VTE were also assessed. RESULTS: Of the 476 orthopaedic patients who met inclusion criteria, 100 (mean age 52.3 median 52, SD 18.3, 70% men) had positive VTE studies. Three hundred seventy-six (age 47.3, SD 17.3, 69% men) had negative VTE studies. Of the 100 patients with VTE, 63 deep vein thromboses, and 49 pulmonary emboli were found. Eight-five percent of all patients met hospital guideline-VTE prophylaxis standards. CONCLUSION: The study population had better than previously reported VTE prophylaxis adherence, however, patients still developed VTEs. LEVEL OF EVIDENCE: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.


Assuntos
Vasos Sanguíneos/diagnóstico por imagem , Procedimentos Ortopédicos/efeitos adversos , Complicações Pós-Operatórias , Tomografia Computadorizada por Raios X/métodos , Ultrassonografia Doppler/métodos , Tromboembolia Venosa/prevenção & controle , Ferimentos e Lesões/complicações , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Fidelidade a Diretrizes , Humanos , Escala de Gravidade do Ferimento , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Centros de Traumatologia , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/etiologia , Ferimentos e Lesões/cirurgia , Adulto Jovem
3.
J Hosp Med ; 11 Suppl 2: S38-S43, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27925422

RESUMO

BACKGROUND: Hospital-acquired venous thromboembolism (HA-VTE) is a potentially preventable cause of morbidity and mortality. Despite high rates of venous thromboembolism (VTE) prophylaxis in accordance with an institutional guideline, VTE remains the most common hospital-acquired condition in our institution. OBJECTIVE: To improve the safety of all hospitalized patients, examine current VTE prevention practices, identify opportunities for improvement, and decrease rates of HA-VTE. DESIGN: Pre/post assessment. SETTING/PATIENTS: Urban academic tertiary referral center, level 1 trauma center, safety net hospital; all patients. INTERVENTION: We formed a multidisciplinary VTE task force to review all HA-VTE events, assess prevention practices relative to evidence-based institutional guidelines, and identify improvement opportunities. The task force developed an electronic tool to facilitate efficient VTE event review and designed decision-support and reporting tools, now integrated into the electronic health record, to bring optimal VTE prevention practices to the point of care. Performance is shared transparently across the institution. MEASUREMENTS: Harborview benchmarks process and outcome performance, including patient safety indicators and core measures, against hospitals nationally using Hospital Compare and Vizient data. RESULTS: Our program has resulted in >90% guideline-adherent VTE prevention and zero preventable HA-VTEs. Initiatives have resulted in a 15% decrease in HA-VTE and a 21% reduction in postoperative VTE. CONCLUSIONS: Keys to success include the multidisciplinary approach, clinical roles of task force members, senior leadership support, and use of quality improvement analytics for retrospective review, prospective reporting, and performance transparency. Ongoing task force collaboration with frontline providers is critical to sustained improvements. Journal of Hospital Medicine 2016;11:S38-S43. © 2016 Society of Hospital Medicine.


Assuntos
Benchmarking , Equipe de Assistência ao Paciente , Segurança do Paciente/estatística & dados numéricos , Melhoria de Qualidade , Tromboembolia Venosa/prevenção & controle , Sistemas de Apoio a Decisões Clínicas/estatística & dados numéricos , Fidelidade a Diretrizes , Humanos
5.
Injury ; 44(12): 1910-5, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24021583

RESUMO

Subtrochanteric femur fractures commonly present with predictable displacement because of the deforming muscle forces acting upon the proximal femur. For this reason, successful closed reduction and femoral nailing can be a technically demanding procedure. Open reduction prior to nail placement has been advocated to improve and maintain anatomic fracture alignment. The purpose of this study was to evaluate the results of patients with closed subtrochanteric femur fractures treated with open reduction and a reamed antegrade statically locked intramedullary nail. An initial query of our database identified 154 patients who had sustained a subtrochanteric femur fracture over the defined study period. Ninety-six patients had adequate radiographic and clinical follow-up. Fifty-six (58%) patients were treated with open reduction and nail placement. There were no wound complications or infections and all patients went on to successful osseous union. There was no loss of reduction and a final coronal and sagittal plane deformity of <5 degrees in 55 of 56 (98%) patients. Open reduction of closed subtrochanteric femur fractures followed by intramedullary nailing leads to high union rates with rare complications.


Assuntos
Pinos Ortopédicos , Fraturas do Fêmur/cirurgia , Fixação Intramedular de Fraturas , Consolidação da Fratura , Complicações Pós-Operatórias/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fraturas do Fêmur/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Fatores de Tempo , Suporte de Carga
6.
Orthop Clin North Am ; 44(1): 35-45, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23174324

RESUMO

Distal humeral fractures are relatively rare and complex injuries. With appropriate preoperative planning and execution of surgical technique, good outcomes may be obtained in most patients. Patients should be counseled regarding loss of motion in these injuries, and elderly, osteoporotic patients with extensive comminution should be considered for total elbow arthroplasty as an alternative to open reduction and internal fixation.


Assuntos
Articulação do Cotovelo/cirurgia , Fraturas do Úmero/terapia , Fraturas Intra-Articulares/cirurgia , Artroplastia de Substituição , Transplante Ósseo , Articulação do Cotovelo/anatomia & histologia , Fixação de Fratura/instrumentação , Humanos , Fraturas do Úmero/classificação , Fraturas do Úmero/diagnóstico , Fraturas Intra-Articulares/diagnóstico , Lesões no Cotovelo
7.
J Orthop Trauma ; 27(2): 100-6, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22549032

RESUMO

OBJECTIVES: The purpose of this study was to assess the impact of variations in angulation of clamp placement to hold syndesmotic reduction and how subsequent syndesmotic screw placement affects malreduction of the syndesmosis. We hypothesized that an anatomic syndesmosis reduction cannot be reliably achieved with a clamp alone; and, inaccurate placement of intraoperative clamps and trans-syndesmotic screws after reduction can malreduce the ankle syndesmosis. METHODS: After computed tomography scanning of the intact limbs, 14 cadaver legs were dissected; the syndesmosis was completely disrupted in all. Using planned drill holes, clamps were first placed at 0°, 15°, and 30° angles from the fibula, then separate posterolateral, followed by lateral, screws were placed. After each intervention, the limb had a computed tomography scan so the fibular reduction could be evaluated precisely. RESULTS: Clamps placed at 15° and 30° significantly displaced the fibula in external rotation and caused significant overcompression of the syndesmosis. Thirty-degree lateral screws caused significant anteromedial displacement, external rotation, and overcompression of the syndesmosis. The 15° posterolateral screws also caused significant external rotation and overcompression of the syndesmosis. CONCLUSIONS: Our study demonstrates that intraoperative clamping and fixation can cause statistically significant malreduction of the syndesmosis. This article should alert clinicians that clamp and screw placement can cause iatrogenic malreduction of the syndesmosis and make them aware that these dangers occur with specific clamp and screw angles in particular.


Assuntos
Traumatismos do Tornozelo/cirurgia , Ligamentos Articulares/cirurgia , Procedimentos Ortopédicos/efeitos adversos , Traumatismos do Tornozelo/diagnóstico por imagem , Parafusos Ósseos , Cadáver , Humanos , Ligamentos Articulares/lesões , Dispositivos de Fixação Ortopédica , Instrumentos Cirúrgicos , Tomografia Computadorizada por Raios X
8.
Orthopedics ; 35(6): e843-6, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22691655

RESUMO

Nonunion and secondary reduction loss complicate open distal femur fractures with bone loss. The authors hypothesized that locking plates decrease subsequent bone grafting yet maintain alignment and immediate postfixation radiographic features predict primary union. A retrospective chart/radiographic review was performed at a Level 1 university trauma center. Thirty-four adults with 36 open AO/Orthopaedic Trauma Association (AO/OTA) C-type distal femur fractures were studied. All fractures were treated with open reduction, internal fixation with a lateral locked implant with or without antibiotic beads, and subsequent bone grafting. Union required radiographic bridging callus on at least 2 of 4 cortices. Alignment was assessed on initial and united radiographs. Antibiotic beads within a metaphyseal defect defined clinically important bone loss. Eleven (55%) of 20 fractures with bone loss underwent staged bone grafting to achieve union vs 2 (13%) of 16 fractures without bone loss. Antibiotic bead presence was associated with staged bone grafting (P<.01). Of those with bone loss and grafting, 3 had posterior cortical bone loss only, 3 had medial and posterior cortical bone loss, and 5 had segmental defects. Of 9 fractures with bone loss not requiring grafting, all had radiographic posterior cortical contact and 7 had radiographic medial cortical contact. Posterior cortical continuity was associated with injuries not requiring bone graft (P<.001). Thirty-four had accurate frontal plane reductions and 35 had accurate sagittal plane reductions. Despite metaphyseal bone loss, locking plates obviate the need for routine bone grafting of some open distal femur fractures. Those with radiographic posterior cortical contact are strongly correlated with primary union.


Assuntos
Placas Ósseas , Transplante Ósseo , Fraturas do Fêmur/cirurgia , Fraturas Mal-Unidas/cirurgia , Fraturas Expostas/cirurgia , Traumatismos do Joelho/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Terapia Combinada , Feminino , Fraturas do Fêmur/diagnóstico por imagem , Fixação Interna de Fraturas/instrumentação , Fraturas Mal-Unidas/diagnóstico por imagem , Fraturas Expostas/diagnóstico por imagem , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Radiografia , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
9.
Am J Orthop (Belle Mead NJ) ; 41(5): 209-12, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22715436

RESUMO

The tibia is the most commonly fractured long bone. Although the goals of fracture management are straightforward, methods for achieving anatomical alignment and stable fixation are limited. Type of management depends on fracture pattern, local soft-tissue involvement, and systemic patient factors. Tibial shaft fractures with concomitant fibula fractures, particularly those at the same level, may be difficult to manage because of their inherent instability. Typically, management of lower extremity fractures is focused on the tibia fixation, and the associated fibula fracture is managed without fixation. In this article, we describe a novel technique for intramedullary fixation of the fibula, using a humeral guide wire as an adjunct to tibia fixation in the setting of tibial shaft fracture. This technique aids in determining length, alignment, and rotation of the tibia fracture and may help support the lower extremity as whole by stabilizing the lateral column. In addition, this technique can be used to help maintain reduction of the fibula when there is concern about the soft tissues of the lower extremity secondary to swelling or injury. Our clinical case series demonstrates the safety, effectiveness, and cost-sensitivity of this technique in managing select concurrent fractures of the tibia and fibula.


Assuntos
Fíbula/lesões , Fixação Intramedular de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fraturas da Tíbia/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fios Ortopédicos , Feminino , Fíbula/cirurgia , Fixação Intramedular de Fraturas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento
10.
Am J Orthop (Belle Mead NJ) ; 41(11): 506-9, 2012 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23431514

RESUMO

We present a novel technique of intramedullary fixation of the fibula using a humeral guide wire as an adjunct to tibial fixation, in the setting of tibial shaft fracture. Not only does this technique aid in determining length, alignment, and rotation of the tibial fracture, but it may also help the support of the lower extremity as whole by stabilizing the lateral column. In addition, this technique can be used to help maintain reduction of the fibula when there is concern for the soft tissues of the lower extremity secondary to swelling or injury. Our clinical case series demonstrates this safe, effective, and cost-sensitive technique to be used in the treatment of select concurrent fractures of the tibia and fibula.


Assuntos
Fíbula/lesões , Fixação Intramedular de Fraturas/instrumentação , Fraturas da Tíbia/cirurgia , Fios Ortopédicos , Fíbula/diagnóstico por imagem , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Fraturas Ósseas/cirurgia , Humanos , Traumatismos da Perna/diagnóstico por imagem , Traumatismos da Perna/cirurgia , Radiografia , Fraturas da Tíbia/diagnóstico por imagem
11.
Foot Ankle Int ; 32(5): S485-92, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21733456

RESUMO

BACKGROUND: The purpose of this study was to assess the ability of miniplate fixation in navicular fractures to restore medial column stability, maintain reduction, and determine the impact this approach may have on the development of avascular collapse of the navicular. We hypothesized that comminuted fractures of the navicular can be safely reduced and maintained to union with minifragment plate fixation with a low incidence of avascular collapse. MATERIALS AND METHODS: A retrospective chart review was performed on 24 patients with navicular fractures treated with open reduction and internal fixation with minifragment plate fixation at a level one trauma center over a period of 6 years. RESULTS: All fractures united. No patient developed a deep infection. There was no loss of reduction. Isolated broken screws were evident in three patients (12.5%), with no plate breakage, and no implant failure by pullout. Four patients (17%) underwent plate removal for painful prominent hardware following fracture healing. Four patients (17%) developed radiographic arthrosis of the talonavicular joint. One patient (4%) had radiographic avascular collapse evident at 6 months and was treated with plate removal and an orthotic device. CONCLUSION: Minifragment fixation was a good alternative to independent lag screws for rigid stabilization of navicular body fractures.


Assuntos
Placas Ósseas , Traumatismos do Pé/cirurgia , Fixação Interna de Fraturas/métodos , Fraturas Cominutivas/cirurgia , Ossos do Tarso/lesões , Adolescente , Adulto , Idoso , Fixação Interna de Fraturas/efeitos adversos , Humanos , Complicações Pós-Operatórias/epidemiologia , Prognóstico , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
12.
J Orthop Trauma ; 25(7): 414-9, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21637122

RESUMO

OBJECTIVES: To describe the pattern of injury, surgical technique, and outcomes of Monteggia Type IID fracture dislocations. DESIGN: Retrospective review of prospectively collected clinical and radiographic patient data in an orthopaedic trauma database. SETTING: Level I university-based trauma center. PATIENTS/PARTICIPANTS: All patients with Monteggia Type IID fracture-dislocations admitted from January 2000 to July 2005. INTERVENTION: Review of patient demographics, fracture pattern, method of fixation, complications, additional surgical procedures, and clinical and radiographic outcome measures. MAIN OUTCOME MEASUREMENTS: Clinical outcomes: elbow range of motion, complications. Radiographic outcomes: characteristic fracture fragments, quality of fracture reduction, healing time, degenerative changes, and heterotopic ossification. RESULTS: Sixteen patients were included in the study. All fractures united. There were six complications in six patients, including three contractures with associated heterotopic ossification, one pronator syndrome and late radial nerve palsy, one radial head collapse, and one with prominent hardware. CONCLUSIONS: Monteggia IID fracture-dislocations are complex injuries with typical specific fracture fragments. Anatomic fixation of all injury components and avoidance of complications where possible can lead to a good outcome in these challenging injuries.


Assuntos
Lesões no Cotovelo , Fixação Interna de Fraturas/métodos , Luxações Articulares/cirurgia , Fratura de Monteggia/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Articulação do Cotovelo/fisiologia , Seguimentos , Fixação Interna de Fraturas/instrumentação , Humanos , Luxações Articulares/diagnóstico por imagem , Fratura de Monteggia/diagnóstico por imagem , Avaliação de Resultados em Cuidados de Saúde , Radiografia , Amplitude de Movimento Articular , Estudos Retrospectivos , Resultado do Tratamento
13.
J Trauma ; 69(1): 148-55, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-20622588

RESUMO

BACKGROUND: The objective of this study is to compare locking and nonlocking single and dual plating constructs in maintaining posteromedial fragment reduction in a bicondylar tibial plateau fracture model. We hypothesized that posteromedial fragment fixation with medial and lateral nonlocked constructs would tolerate higher loads than with lateral locked constructs alone. METHODS: Thirty composite tibiae were fractured (AO 41-C1.3). Six constructs were tested: (1) lateral 3.5-mm conventional nonlocking proximal tibial plate (CP); (2) CP + posteromedial 3.5-mm limited contact dynamic compression plate; (3) CP + posteromedial 1/3 tubular plate (CP + 1/3 tubular); (4) 3.5-mm Zimmer Proximal Tibial Locking plate; (5) 3.5-mm Synthes Locking Compression plate; and (6) Less Invasive Stabilization System tibial plate. Specimens were cyclically loaded to failure or a maximum of 4000 N. RESULTS: Failure occurred at the posteromedial fragment first. The CP + 1/3 tubular had the highest average load to failure (3040 N). The CP + 1/3 tubular demonstrated higher load at failure compared with the 3.5-mm Synthes Locking Compression plate (p = 0.0060) and the Less Invasive Stabilization System (p = 0.0360). The CP + 1/3 tubular did not demonstrate a difference in load at failure when compared with the CP (p = 0.4225), the CP + posteromedial 3.5-mm limited contact dynamic compression plate (p = 0.4799), or the 3.5-mm Zimmer Proximal Tibial Locking plate (p = 0.1595). CONCLUSIONS: The posteromedial fragment tolerated higher loads with the CP + 1/3 tubular plate construct. The superiority of this construct may be caused by unreliable penetration of this fragment by the lateral locking screws.


Assuntos
Placas Ósseas , Fixação Interna de Fraturas/métodos , Fraturas da Tíbia/cirurgia , Adulto , Placas Ósseas/normas , Parafusos Ósseos , Humanos , Estresse Mecânico , Suporte de Carga
14.
J Trauma ; 68(4): 949-53, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19996807

RESUMO

BACKGROUND: The management of unstable pelvic ring injuries is complex. Displacement is a clear indication for surgical intervention. However, reduction of acute pain after stabilization may have substantial clinical benefits and affect management decisions. The purpose of this study was to determine the impact of operative fixation of unstable pelvic ring injuries in diminishing acute pain. METHODS: During a 33-month period, 70 patients with isolated pelvic ring injuries were managed at a Level-1 trauma center and retrospectively reviewed. On the basis of clinical and radiographic instability, 38 patients were managed surgically and formed the study group. Pain was assessed using visual analog scales and narcotic consumption during the index hospitalization. RESULTS: In the operative group, visual analog scale scores decreased 48% after fixation from 4.71 +/- 1.8 preoperatively to 2.85 +/- 0.8 postoperatively (p < 0.001). Concomitantly, narcotic requirements decreased 25% from 2.26 mg morphine per hour preoperatively to 1.71 mg morphine per hour postoperatively (p = 0.024). The mean total length of hospital stay was 5.6 days (SD, 1.2 days), and the postoperative length of hospital stay was 4.7 days (SD, 1.2 days). CONCLUSIONS: Operative reduction and fixation of unstable pelvic ring injuries significantly decreases acute pain. This has substantial physiologic benefits, particularly by improving mobilization, and should be an additional factor when determining surgical indication and timing.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Manejo da Dor , Ossos Pélvicos/lesões , Ossos Pélvicos/cirurgia , Adulto , Feminino , Fraturas Ósseas/complicações , Humanos , Tempo de Internação/estatística & dados numéricos , Masculino , Entorpecentes/uso terapêutico , Dor/etiologia , Medição da Dor , Estudos Retrospectivos , Resultado do Tratamento
16.
J Shoulder Elbow Surg ; 16(2): 213-7, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17399625

RESUMO

The objective of this study was to determine the effect of suture repair of type 1 coronoid fractures on elbow kinematics in ligamentously intact and medial collateral ligament (MCL)-deficient elbows. Cadaveric testing was performed in stable and MCL-deficient elbows with radial head arthroplasty and with the coronoid intact, with the coronoid fractured, and after suture repair. Ulna versus humerus angulation was measured during active motion. Varus and valgus motion pathways were measured during passive gravity-loaded flexion. With intact ligaments, there was a small increase in valgus angulation after a type 1 fracture that was not corrected with suture fixation. With MCL deficiency, there was no change in kinematics regardless of coronoid status. Type 1 coronoid fractures cause only small changes in elbow kinematics that are not corrected with suture repair. MCL repair, rather than type 1 coronoid fixation, should be considered if the elbow remains unstable after radial head repair or replacement and lateral ligament repair.


Assuntos
Ligamentos Colaterais/cirurgia , Articulação do Cotovelo/fisiopatologia , Articulação do Cotovelo/cirurgia , Fraturas do Rádio/cirurgia , Suturas , Idoso , Idoso de 80 Anos ou mais , Fenômenos Biomecânicos , Cadáver , Humanos , Pessoa de Meia-Idade , Fraturas do Rádio/classificação , Amplitude de Movimento Articular
17.
Clin Biomech (Bristol, Avon) ; 22(2): 183-90, 2007 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17101201

RESUMO

BACKGROUND: Coronoid fractures often occur in the setting of more complex elbow trauma. Little is known about the influence of coronoid fracture size on elbow kinematics, particularly in the setting of concomitant ligament injuries. The purpose of this study was to determine the effect of coronoid fractures on elbow kinematics and stability in ligamentously intact and medial collateral ligament deficient elbows and to determine the effect of forearm position on elbow stability in the setting of coronoid fracture. METHODS: Eight cadaveric arms were tested during simulated active dependent elbow motion and gravity-loaded passive elbow motion. Kinematic data were collected from an electromagnetic tracking system. The protocol was performed in ligament origin repaired and medial collateral ligament deficient elbows with radial head arthroplasty. Testing was carried out with the coronoid intact, and with 10% (Type I), 50% (Type II), and 90% (Type III) removed. Varus-valgus angulation of the ulna relative to the humerus and maximum varus-valgus laxity were measured. FINDINGS: With repaired ligament origins and medial collateral ligament deficiency, there was increased varus angulation and increased maximum varus-valgus laxity following simulation of a Type II and Type III coronoid fracture. There was less kinematic change with the forearm in supination than in pronation. INTERPRETATION: Elbow kinematics are altered with increasing coronoid fracture size. Repair of Type II and Type III coronoid fractures as well as lateral ligament repair is recommended where possible. Forearm supination may be considered during rehabilitation following coronoid repair. Valgus elbow positioning should be avoided if the medial collateral ligament is not repaired.


Assuntos
Fenômenos Biomecânicos/métodos , Articulação do Cotovelo/fisiopatologia , Cotovelo/anatomia & histologia , Fraturas Ósseas/fisiopatologia , Instabilidade Articular/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Cadáver , Cotovelo/patologia , Humanos , Pessoa de Meia-Idade , Movimento , Osteotomia , Rotação
18.
J Shoulder Elbow Surg ; 14(1 Suppl S): 195S-201S, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15726082

RESUMO

Controversy exists as to the optimal management of radial head fractures. Biomechanical studies have been conducted to quantify elbow stability for simulated wedge fractures, head excision, and head replacement, with and without the integrity of the collateral ligaments. Our in vitro studies have demonstrated that in the ligamentously intact elbow, kinematics and stability are slightly altered with simulated depressed wedge fractures up to 120 degrees of the radial head, markedly altered with head resection, and improved after radial head replacement. Radial head excision decreases elbow stability in the ligament-deficient elbow, and radial head replacement improves stability similar to that of the native radial head. The ligaments have the most marked influence on stability, particularly when the upper limb is positioned such that valgus and varus gravity loads are applied to the elbow. Whereas the radial head acts as a secondary stabilizer to the collateral ligaments with the arm in these positions, its relative role is greater when the arm is in the dependent position and elbow flexion is simulated, particularly in extension. Further studies are needed to elucidate the complex interaction of the radial head with the capitellum, the ulnohumeral joint, and the ligamentous structures for different activities of daily living.


Assuntos
Lesões no Cotovelo , Articulação do Cotovelo/cirurgia , Fraturas do Rádio/cirurgia , Fenômenos Biomecânicos , Humanos
19.
J Orthop Res ; 23(1): 210-7, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15607895

RESUMO

This study determined the effect of radial head fracture size and ligament injury on elbow kinematics. Eight cadaveric upper extremities were studied in an in vitro elbow simulator. Testing was performed with ligaments intact, with the medial collateral (MCL) or lateral collateral (LCL) ligament detached, and with both the MCL and LCL detached. Thirty degree wedges were sequentially removed from the anterolateral radial head up to 120 degrees . Valgus angulation and external rotation of the ulna relative to the humerus were determined for passive motion, active motion, and pivot shift testing with the arm in a vertical (dependent) orientation. Maximum varus-valgus laxity was calculated from measurements of varus and valgus angulation with the arm in horizontal gravity-loaded positions. No effect of increasing radial head fracture size was observed on valgus angulation during passive and active motion in the dependent position. In supination, external rotation increased with increasing fracture size during passive motion with LCL deficiency and both MCL and LCL deficiency. With intact ligaments, maximum varus-valgus laxity increased with increasing radial head fracture size. With ligament disruption, elbows were grossly unstable, and no effect of increasing radial head fracture size occurred. During pivot shift testing, performed with the ligaments intact, subtle instability was noted after resection of one-third of the radial head. In this in vitro biomechanical study, small subtle effects of radial head fracture size on elbow kinematics and stability were seen in both the ligament intact and ligament deficient elbows. These data suggest that fixation of displaced radial head fractures less than or equal to one-third of the articular diameter may have some biomechanical advantages; however, clinical correlation is required.


Assuntos
Cotovelo/fisiologia , Fraturas do Rádio/fisiopatologia , Idoso , Fenômenos Biomecânicos , Humanos , Rotação
20.
J Bone Joint Surg Am ; 86(8): 1730-9, 2004 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-15292422

RESUMO

BACKGROUND: Radial head fractures are common injuries. Comminuted radial head fractures often are treated with radial head excision with or without radial head arthroplasty. The purpose of the present study was to determine the effect of radial head excision and arthroplasty on the kinematics and stability of elbows with intact and disrupted ligaments. We hypothesized that elbow kinematics and stability would be (1) altered after radial head excision in elbows with intact and disrupted ligaments, (2) restored after radial head arthroplasty in elbows with intact ligaments, and (3) partially restored after radial head arthroplasty in elbows with disrupted ligaments. METHODS: Eight cadaveric upper extremities were studied in an in vitro elbow simulator that employed computer-controlled actuators to govern tendon-loading. Testing was performed in stable, medial collateral ligament-deficient, and lateral collateral ligament-deficient elbows with the radial head intact, with the radial head excised, and after radial head arthroplasty. Valgus angulation and rotational kinematics were determined during passive and simulated active motion with the arm dependent. Maximum varus-valgus laxity was measured with the arm in a gravity-loaded position. RESULTS: In specimens with intact ligaments, elbow kinematics were altered and varus-valgus laxity was increased after radial head excision and both were corrected after radial head arthroplasty. In specimens with disrupted ligaments, elbow kinematics were altered after radial head excision and were similar to those observed in specimens with a native radial head after radial head arthroplasty. Varus-valgus laxity was increased after ligament disruption and was further increased after radial head excision. Varus-valgus laxity was corrected after radial head arthroplasty and ligament repair; however, it was not corrected after radial head arthroplasty without ligament repair. CONCLUSIONS: Radial head excision causes altered elbow kinematics and increased laxity. The kinematics and laxity of stable elbows after radial head arthroplasty are similar to those of elbows with a native radial head. However, radial head arthroplasty alone may be insufficient for the treatment of complex fractures that are associated with damage to the collateral ligaments as arthroplasty alone does not restore stability to elbows with ligament injuries.


Assuntos
Artroplastia/métodos , Articulação do Cotovelo/fisiologia , Articulação do Cotovelo/cirurgia , Rádio (Anatomia)/cirurgia , Idoso , Fenômenos Biomecânicos , Cadáver , Humanos , Ligamentos Articulares/fisiologia , Ligamentos Articulares/cirurgia , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...