Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Radiat Prot Dosimetry ; 199(14): 1485-1494, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37721069

RESUMO

The objective was to investigate the influence of different pre-storage temperatures in the dicentric chromosome analysis (DCA) protocol (22°C vs. 37°C) by using γ-H2AX + 53BP1 foci as a marker for deoxyribonucleic acid (DNA) double-strand break (DSB) damage induction and repair and the formation of dicentric chromosomes as a result of mis-repair. Repair of γ-H2AX + 53BP1 DSB foci was absent in samples that were incubated for 2 h at 22°C after exposure of 0.5 and 1.2 Gy. When 0.5- and 1.2-Gy-exposed samples were incubated at 37°C for 2 h, there was an average decline of 31 and 52% of DSB foci, respectively. This indicated that DNA repair occurred. There was a 27% decrease in dicentric chromosome yield at 1.2 Gy and a 15% decrease at 3.5 Gy after post-irradiation incubation for 2 h at 37°C relative to the observed dicentric frequencies at 22°C. Recommended to re-phase: our data suggested that there were more open DSBs after a 2-h incubation at 22°C, which contributed to more mis-repair and dicentric formation from the start of culture. Our findings are corroborated by publications showing that lesion interaction based on enzymatic activity is suppressed below 21°C. As such temperature variations can be a source of variation in DCA during interlaboratory comparison studies, we propose to establish a common guide for the standardisation of pre-culture conditions in cytogenetic dosimetry proficiency testing.


Assuntos
Quebras de DNA de Cadeia Dupla , Reparo do DNA , Temperatura , Citogenética , Cromossomos/genética
2.
Cytogenet Genome Res ; 163(3-4): 163-177, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37071978

RESUMO

In the case of a radiological or nuclear event, biological dosimetry can be an important tool to support clinical decision-making. During a nuclear event, individuals might be exposed to a mixed field of neutrons and photons. The composition of the field and the neutron energy spectrum influence the degree of damage to the chromosomes. During the transatlantic BALANCE project, an exposure similar to a Hiroshima-like device at a distance of 1.5 km from the epicenter was simulated, and biological dosimetry based on dicentric chromosomes was performed to evaluate the participants ability to discover unknown doses and to test the influence of differences in neutron spectra. In a first step, calibration curves were established by irradiating blood samples with 5 doses in the range of 0-4 Gy at two different facilities in Germany (Physikalisch-Technische Bundesanstalt [PTB]) and the USA (the Columbia IND Neutron Facility [CINF]). The samples were sent to eight participating laboratories from the RENEB network and dicentric chromosomes were scored by each participant. Next, blood samples were irradiated with 4 blind doses in each of the two facilities and sent to the participants to provide dose estimates based on the established calibration curves. Manual and semiautomatic scoring of dicentric chromosomes were evaluated for their applicability to neutron exposures. Moreover, the biological effectiveness of the neutrons from the two irradiation facilities was compared. The calibration curves from samples irradiated at CINF showed a 1.4 times higher biological effectiveness compared to samples irradiated at PTB. For manual scoring of dicentric chromosomes, the doses of the test samples were mostly successfully resolved based on the calibration curves established during the project. For semiautomatic scoring, the dose estimation for the test samples was less successful. Doses >2 Gy in the calibration curves revealed nonlinear associations between dose and dispersion index of the dicentric counts, especially for manual scoring. The differences in the biological effectiveness between the irradiation facilities suggested that the neutron energy spectrum can have a strong impact on the dicentric counts.


Assuntos
Nêutrons , Humanos , Alemanha
3.
Int J Radiat Biol ; 97(9): 1181-1198, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34138666

RESUMO

PURPOSE: Biological and/or physical assays for retrospective dosimetry are valuable tools to recover the exposure situation and to aid medical decision making. To further validate and improve such biological and physical assays, in 2019, EURADOS Working Group 10 and RENEB performed a field exercise in Lund, Sweden, to simulate various real-life exposure scenarios. MATERIALS AND METHODS: For the dicentric chromosome assay (DCA), blood tubes were located at anthropomorphic phantoms positioned in different geometries and were irradiated with a 1.36 TBq 192Ir-source. For each exposure condition, dose estimates were provided by at least one laboratory and for four conditions by 17 participating RENEB laboratories. Three radio-photoluminescence glass dosimeters were placed at each tube to assess reference doses. RESULTS: The DCA results were homogeneous between participants and matched well with the reference doses (≥95% of estimates within ±0.5 Gy of the reference). For samples close to the source systematic underestimation could be corrected by accounting for exposure time. Heterogeneity within and between tubes was detected for reference doses as well as for DCA doses estimates. CONCLUSIONS: The participants were able to successfully estimate the doses and to provide important information on the exposure scenarios under conditions closely resembling a real-life situation.


Assuntos
Cromossomos Humanos/genética , Cromossomos Humanos/efeitos da radiação , Radiometria , Aberrações Cromossômicas/efeitos da radiação , Humanos , Exposição à Radiação/análise , Estudos Retrospectivos
4.
Int J Radiat Biol ; 97(7): 888-905, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33970757

RESUMO

PURPOSE: In case of a mass-casualty radiological event, there would be a need for networking to overcome surge limitations and to quickly obtain homogeneous results (reported aberration frequencies or estimated doses) among biodosimetry laboratories. These results must be consistent within such network. Inter-laboratory comparisons (ILCs) are widely accepted to achieve this homogeneity. At the European level, a great effort has been made to harmonize biological dosimetry laboratories, notably during the MULTIBIODOSE and RENEB projects. In order to continue the harmonization efforts, the RENEB consortium launched this intercomparison which is larger than the RENEB network, as it involves 38 laboratories from 21 countries. In this ILC all steps of the process were monitored, from blood shipment to dose estimation. This exercise also aimed to evaluate the statistical tools used to compare laboratory performance. MATERIALS AND METHODS: Blood samples were irradiated at three different doses, 1.8, 0.4 and 0 Gy (samples A, C and B) with 4-MV X-rays at 0.5 Gy min-1, and sent to the participant laboratories. Each laboratory was requested to blindly analyze 500 cells per sample and to report the observed frequency of dicentric chromosomes per metaphase and the corresponding estimated dose. RESULTS: This ILC demonstrates that blood samples can be successfully distributed among laboratories worldwide to perform biological dosimetry in case of a mass casualty event. Having achieved a substantial harmonization in multiple areas among the RENEB laboratories issues were identified with the available statistical tools, which are not capable to advantageously exploit the richness of results of a large ILCs. Even though Z- and U-tests are accepted methods for biodosimetry ILCs, setting the number of analyzed metaphases to 500 and establishing a tests' common threshold for all studied doses is inappropriate for evaluating laboratory performance. Another problem highlighted by this ILC is the issue of the dose-effect curve diversity. It clearly appears that, despite the initial advantage of including the scoring specificities of each laboratory, the lack of defined criteria for assessing the robustness of each laboratory's curve is a disadvantage for the 'one curve per laboratory' model. CONCLUSIONS: Based on our study, it seems relevant to develop tools better adapted to the collection and processing of results produced by the participant laboratories. We are confident that, after an initial harmonization phase reached by the RENEB laboratories, a new step toward a better optimization of the laboratory networks in biological dosimetry and associated ILC is on the way.


Assuntos
Laboratórios , Radiometria , Aberrações Cromossômicas/efeitos da radiação , Humanos , Exposição à Radiação , Reprodutibilidade dos Testes
5.
Int J Radiat Biol ; 97(2): 256-264, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33211606

RESUMO

PURPOSE: The MSc Radiation Biology course is a highly interdisciplinary degree program placing radiation biology at the interface between biology, medicine, and physics, as well as their associated technologies. The goal was to establish an internationally acknowledged program with diverse and heterogeneous student cohorts, who benefit from each other academically as well as culturally. We have completed a Five-Year evaluation of the program to assess our qualification profile and the further direction we want to take. MATERIALS AND METHODS: We evaluated the student cohort's data from the last 5 years regarding gender, age, and nationality as well as the highest degree before applying and career path after graduation. RESULTS: Data shows a great diversity regarding nationalty as well as undergraduate background. Cohort sizes could be increased and future prospects mainly aimed to a PhD. Measures after regular quality meetings and students' feedback led to improving the curriculum and workload, teacher's training, and changes to examination regulations. CONCLUSIONS: After 5 years, statistics show that our expectations have been met exceedingly. All graduates had excellent career opportunities reflecting the necessity of this MSc and its topics. We are continuously working on improving the program and adapting the curriculum to the requirements in radiation sciences. The future vision includes an expansion of the program as well as undergraduate education opportunities in this field.


Assuntos
Radiobiologia/educação , Adulto , Currículo , Feminino , Humanos , Masculino
6.
Radiat Environ Biophys ; 59(3): 461-472, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32409897

RESUMO

Ionizing radiation produces reactive oxygen species (ROS) leading to cellular DNA damage. Therefore, patients undergoing radiation therapy or first responders in radiological accident scenarios could both benefit from the identification of specifically acting pharmacological radiomitigators. The synthetic triterpenoid bardoxolone-methyl (CDDO-Me) has previously been shown to exert antioxidant, anti-inflammatory and anticancer activities in several cell lines, in part by enhancing the DNA damage response. In our study, we examined the effect of nanomolar concentrations of CDDO-Me in human peripheral blood mononuclear cells (PBMC). We observed increased cellular levels of the antioxidative enzymes heme oxygenase-1 (HO-1), NAD(P)H dehydrogenase (quinone1) and mitochondrial superoxide dismutase 2 by immunoblotting. Surprisingly, we found increased intracellular ROS-levels using imaging flow-cytometry. However, the radiation-induced DNA double-strand break (DSB) formation using the γ-H2AX + 53BP1 DSB focus assay and the cytokinesis-block micronucleus assay both revealed, that nanomolar CDDO-Me pre-treatment of PBMC for 2 h or 6 h ahead of X irradiation with 2 Gy did neither significantly affect γ-H2AX + 53BP1 DSB foci formation nor the frequency of micronuclei. CDDO-Me treatment also failed to alter the nuclear division index and the frequency of IR-induced PBMC apoptosis as investigated by Annexin V-labeled live-cell imaging. Our results indicate that pharmacologically increased cellular concentrations of antioxidative enzymes might not necessarily exert radiomitigating short-term effects in IR-exposed PBMC. However, the increase of antioxidative enzymes could also be a result of a defensive cellular mechanism towards elevated ROS levels.


Assuntos
Leucócitos Mononucleares/efeitos dos fármacos , Leucócitos Mononucleares/efeitos da radiação , Ácido Oleanólico/análogos & derivados , Raios X , Adulto , Apoptose/efeitos dos fármacos , Apoptose/efeitos da radiação , Sobrevivência Celular/efeitos dos fármacos , Sobrevivência Celular/efeitos da radiação , Células Cultivadas , Quebras de DNA de Cadeia Dupla , Feminino , Humanos , Leucócitos Mononucleares/metabolismo , Masculino , Testes para Micronúcleos , Pessoa de Meia-Idade , Ácido Oleanólico/farmacologia , Espécies Reativas de Oxigênio/metabolismo
7.
Radiat Res ; 188(5): 571-578, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-28952879

RESUMO

Thirty years after the Chernobyl nuclear power plant accident we report on a patient who was a clean-up worker, who subsequently developed multiple cutaneous basal cell carcinomas (BCCs). We used several methods to assess the biological long-term effects related to low-dose external and internal radiation exposure. Specifically, because BCC risk may be increased with ionizing radiation exposure, we endeavored to determine whether the multifocal BCCs were related to the patient's past clean-up work. We assessed cytogenetic changes using peripheral blood, and internal incorporation was measured with a whole-body counter. Gene expression alterations were determined and array-based comparative genomic hybridization was performed for copy number aberration analysis of available BCC samples. In 1,053 metaphase cells, the dicentric yield of 0.005 dicentrics, with acentrics/cell, was significantly increased compared to the established calibration curve (P < 0.001). A 2.5-fold increase in total translocations was observed compared to the expected translocation rate. No internal contamination was detected with the whole-body counter. At the RNA level, two of seven genes (HNRNPA1, AGAP4/6/8) indicated internal plutonium exposure associated with the lowest dose category found in Mayak workers (>0-0.055 Gy). Relevant DNA copy number changes were only detected within the most aggressive BCC focus. Our results suggest that the examined worker had low and more recent radiation exposure with presumably internalized radionuclides that were below the detection level of a whole-body counter. The multifocal BCC could not be related to past occupational radiation exposure. The findings from our study suggest that integrating different methodologies potentially provides an improved overall assessment of individual health risks associated with or excluding occupational radiation exposure.


Assuntos
Carcinoma Basocelular/genética , Acidente Nuclear de Chernobyl , Exposição Ocupacional/efeitos adversos , Exposição à Radiação/efeitos adversos , Adulto , Carcinoma Basocelular/etiologia , Aberrações Cromossômicas/efeitos da radiação , Análise Citogenética , Variações do Número de Cópias de DNA/efeitos da radiação , Relação Dose-Resposta à Radiação , Humanos , Masculino , Pessoa de Meia-Idade , Plutônio/efeitos adversos , Risco , Transcriptoma/efeitos da radiação , Contagem Corporal Total
8.
Int J Radiat Biol ; 93(1): 136-141, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27557790

RESUMO

PURPOSE: To identify and assess, among the participants in the RENEB (Realizing the European Network of Biodosimetry) project, the emergency preparedness, response capabilities and resources that can be deployed in the event of a radiological or nuclear accident/incident affecting a large number of individuals. These capabilities include available biodosimetry techniques, infrastructure, human resources (existing trained staff), financial and organizational resources (including the role of national contact points and their articulation with other stakeholders in emergency response) as well as robust quality control/assurance systems. MATERIALS AND METHODS: A survey was prepared and sent to the RENEB partners in order to acquire information about the existing, operational techniques and infrastructure in the laboratories of the different RENEB countries and to assess the capacity of response in the event of radiological or nuclear accident involving mass casualties. The survey focused on several main areas: laboratory's general information, country and staff involved in biological and physical dosimetry; retrospective assays used, the number of assays available per laboratory and other information related to biodosimetry and emergency preparedness. Following technical intercomparisons amongst RENEB members, an update of the survey was performed one year later concerning the staff and the available assays. CONCLUSIONS: The analysis of RENEB questionnaires allowed a detailed assessment of existing capacity of the RENEB network to respond to nuclear and radiological emergencies. This highlighted the key importance of international cooperation in order to guarantee an effective and timely response in the event of radiological or nuclear accidents involving a considerable number of casualties. The deployment of the scientific and technical capabilities existing within the RENEB network members seems mandatory, to help other countries with less or no capacity for biological or physical dosimetry, or countries overwhelmed in case of a radiological or nuclear accident involving a large number of individuals.


Assuntos
Pesquisa Biomédica/organização & administração , Planejamento em Desastres/organização & administração , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Liberação Nociva de Radioativos , Gestão da Segurança/organização & administração , Europa (Continente) , Modelos Organizacionais , Radiobiologia/organização & administração
9.
Int J Radiat Biol ; 93(1): 75-80, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27559844

RESUMO

PURPOSE: The RENEB accident exercise was carried out in order to train the RENEB participants in coordinating and managing potentially large data sets that would be generated in case of a major radiological event. MATERIALS AND METHODS: Each participant was offered the possibility to activate the network by sending an alerting email about a simulated radiation emergency. The same participant had to collect, compile and report capacity, triage categorization and exposure scenario results obtained from all other participants. The exercise was performed over 27 weeks and involved the network consisting of 28 institutes: 21 RENEB members, four candidates and three non-RENEB partners. RESULTS: The duration of a single exercise never exceeded 10 days, while the response from the assisting laboratories never came later than within half a day. During each week of the exercise, around 4500 samples were reported by all service laboratories (SL) to be examined and 54 scenarios were coherently estimated by all laboratories (the standard deviation from the mean of all SL answers for a given scenario category and a set of data was not larger than 3 patient codes). CONCLUSIONS: Each participant received training in both the role of a reference laboratory (activating the network) and of a service laboratory (responding to an activation request). The procedures in the case of radiological event were successfully established and tested.


Assuntos
Planejamento em Desastres/organização & administração , Monitoramento de Radiação/métodos , Liberação Nociva de Radioativos , Radiobiologia/educação , Gestão da Segurança/organização & administração , Triagem/organização & administração , Europa (Continente)
10.
Int J Radiat Biol ; 93(1): 30-35, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27705052

RESUMO

PURPOSE: In the framework of RENEB, several biodosimetry exercises were conducted analyzing different endpoints. Among them, the analysis of translocations is considered the most useful method for retrospective biodosimetry due to the relative stability of their frequency with post irradiation time. The aim of this study was to harmonize the accuracy of translocation-based biodosimetry within the RENEB consortium. MATERIALS AND METHODS: An initial telescoring exercise analyzing FISH metaphase images was done to harmonize chromosome aberration descriptions. Then two blind intercomparison exercises (IE) were performed, by sending irradiated blood samples to each partner. Samples were cultured and stained by each partner using their standard protocol and translocation frequency was used to produce dose estimates. RESULTS: The coefficient of variation in the 1st IE (CV = 0.34) was higher than in the 2nd IE (CV = 0.16 and 0.23 in the two samples analyzed), for the genomic frequency of total translocations. Z-score analysis revealed that eight out of 10 and 17 out of 20 dose estimates were satisfactory in the 1st and 2nd IE, respectively. CONCLUSIONS: The results obtained indicate that, despite the problems identified in few partners, which can be corrected, the RENEB consortium is able to carry out retrospective biodosimetry analyzing the frequency of translocations by FISH.


Assuntos
Bioensaio/métodos , Hibridização in Situ Fluorescente/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Translocação Genética/efeitos da radiação , Bioensaio/normas , Europa (Continente) , Humanos , Hibridização in Situ Fluorescente/normas , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Translocação Genética/genética
11.
Int J Radiat Biol ; 93(1): 36-47, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27673504

RESUMO

PURPOSE: In the framework of the 'Realizing the European Network of Biodosimetry' (RENEB) project, two intercomparison exercises were conducted to assess the suitability of an optimized version of the cytokinesis-block micronucleus assay, and to evaluate the capacity of a large laboratory network performing biodosimetry for radiation emergency triages. Twelve European institutions participated in the first exercise, and four non-RENEB labs were added in the second one. MATERIALS AND METHODS: Irradiated blood samples were shipped to participating labs, whose task was to culture these samples and provide a blind dose estimate. Micronucleus analysis was performed by automated, semi-automated and manual procedures. RESULTS: The dose estimates provided by network laboratories were in good agreement with true administered doses. The most accurate estimates were reported for low dose points (≤ 0.94 Gy). For higher dose points (≥ 2.7 Gy) a larger variation in estimates was observed, though in the second exercise the number of acceptable estimates increased satisfactorily. Higher accuracy was achieved with the semi-automated method. CONCLUSION: The results of the two exercises performed by our network demonstrate that the micronucleus assay is a useful tool for large-scale radiation emergencies, and can be successfully implemented within a large network of laboratories.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
12.
Int J Radiat Biol ; 93(1): 110-117, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27547893

RESUMO

PURPOSE: To establish a training data set of digital images and to investigate the scoring criteria and dose assessment of the dicentric assay within the European network of biodosimetry (RENEB), a web based scoring inter-comparison was undertaken by 17 RENEB partners. MATERIALS AND METHODS: Two sets of 50 high resolution images were uploaded onto the RENEB website. One set included metaphases after a moderate exposure (1.3 Gy) and the other set consisted of metaphases after a high dose exposure (3.5 Gy). The laboratories used their own calibration curves for estimating doses based on observed aberration frequencies. RESULTS: The dose estimations and 95% confidence limits were compared to the actual doses and the corresponding z-values were satisfactory for the majority; only the dose estimations from two laboratories were too low or too high. The coefficients of variation were 17.6% for the moderate and 11.2% for the high dose. Metaphases with controversial results could be identified for training purposes. CONCLUSIONS: Overall, the web based scoring of the two galleries by the 17 laboratories produced very good results. Application of web based scoring for the dicentric assay may therefore be a relevant strategy for an operational biodosimetry assistance network.


Assuntos
Bioensaio/métodos , Análise Citogenética/métodos , Internet/organização & administração , Linfócitos/efeitos da radiação , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Europa (Continente) , Humanos , Laboratórios/estatística & dados numéricos , Linfócitos/citologia , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
13.
Int J Radiat Biol ; 93(1): 2-14, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27707245

RESUMO

PURPOSE: A European network was initiated in 2012 by 23 partners from 16 European countries with the aim to significantly increase individualized dose reconstruction in case of large-scale radiological emergency scenarios. RESULTS: The network was built on three complementary pillars: (1) an operational basis with seven biological and physical dosimetric assays in ready-to-use mode, (2) a basis for education, training and quality assurance, and (3) a basis for further network development regarding new techniques and members. Techniques for individual dose estimation based on biological samples and/or inert personalized devices as mobile phones or smart phones were optimized to support rapid categorization of many potential victims according to the received dose to the blood or personal devices. Communication and cross-border collaboration were also standardized. To assure long-term sustainability of the network, cooperation with national and international emergency preparedness organizations was initiated and links to radiation protection and research platforms have been developed. A legal framework, based on a Memorandum of Understanding, was established and signed by 27 organizations by the end of 2015. CONCLUSIONS: RENEB is a European Network of biological and physical-retrospective dosimetry, with the capacity and capability to perform large-scale rapid individualized dose estimation. Specialized to handle large numbers of samples, RENEB is able to contribute to radiological emergency preparedness and wider large-scale research projects.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/organização & administração , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Proteção Radiológica/métodos , Gestão da Segurança/organização & administração , Emergências , Europa (Continente) , Humanos , Objetivos Organizacionais , Exposição à Radiação/análise , Exposição à Radiação/prevenção & controle , Liberação Nociva de Radioativos/prevenção & controle
14.
Int J Radiat Biol ; 93(1): 20-29, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27766931

RESUMO

PURPOSE: Two quality controlled inter-laboratory exercises were organized within the EU project 'Realizing the European Network of Biodosimetry (RENEB)' to further optimize the dicentric chromosome assay (DCA) and to identify needs for training and harmonization activities within the RENEB network. MATERIALS AND METHODS: The general study design included blood shipment, sample processing, analysis of chromosome aberrations and radiation dose assessment. After manual scoring of dicentric chromosomes in different cell numbers dose estimations and corresponding 95% confidence intervals were submitted by the participants. RESULTS: The shipment of blood samples to the partners in the European Community (EU) were performed successfully. Outside the EU unacceptable delays occurred. The results of the dose estimation demonstrate a very successful classification of the blood samples in medically relevant groups. In comparison to the 1st exercise the 2nd intercomparison showed an improvement in the accuracy of dose estimations especially for the high dose point. CONCLUSIONS: In case of a large-scale radiological incident, the pooling of ressources by networks can enhance the rapid classification of individuals in medically relevant treatment groups based on the DCA. The performance of the RENEB network as a whole has clearly benefited from harmonization processes and specific training activities for the network partners.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Testes para Micronúcleos/métodos , Garantia da Qualidade dos Cuidados de Saúde , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Bioensaio/normas , Europa (Continente) , Humanos , Linfócitos/efeitos da radiação , Monitoramento de Radiação/normas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
Int J Radiat Biol ; 93(1): 99-109, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27437830

RESUMO

PURPOSE: RENEB, 'Realising the European Network of Biodosimetry and Physical Retrospective Dosimetry,' is a network for research and emergency response mutual assistance in biodosimetry within the EU. Within this extremely active network, a number of new dosimetry methods have recently been proposed or developed. There is a requirement to test and/or validate these candidate techniques and inter-comparison exercises are a well-established method for such validation. MATERIALS AND METHODS: The authors present details of inter-comparisons of four such new methods: dicentric chromosome analysis including telomere and centromere staining; the gene expression assay carried out in whole blood; Raman spectroscopy on blood lymphocytes, and detection of radiation-induced thermoluminescent signals in glass screens taken from mobile phones. RESULTS: In general the results show good agreement between the laboratories and methods within the expected levels of uncertainty, and thus demonstrate that there is a lot of potential for each of the candidate techniques. CONCLUSIONS: Further work is required before the new methods can be included within the suite of reliable dosimetry methods for use by RENEB partners and others in routine and emergency response scenarios.


Assuntos
Bioensaio/métodos , Planejamento em Desastres/métodos , Laboratórios , Exposição à Radiação/análise , Monitoramento de Radiação/métodos , Gestão da Segurança/métodos , União Europeia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade , Integração de Sistemas
16.
Radiat Prot Dosimetry ; 172(1-3): 192-200, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27412509

RESUMO

The BioDoseNet was founded by the World Health Organization as a global network of biodosimetry laboratories for building biodosimetry laboratory capacities in countries. The newly established BioDoseNet image repository is a databank of ~25 000 electronically captured images of metaphases from the dicentric assay, which have been previously analysed by international experts. The detailed scoring results and dose estimations have, in most cases, already been published. The compilation of these images into one image repository provides a valuable tool for training and research purposes in biological dosimetry. No special software is needed to view and score the image galleries. For those new to the dicentric assay, the BioDoseNet Image Repository provides an introduction to and training for the dicentric assay. It is an excellent instrument for intra-laboratory training purposes or inter-comparisons between laboratories, as recommended by the International Organization for Standardisation standards. In the event of a radiation accident, the repository can also increase the surge capacity and reduce the turnaround time for dose estimations. Finally, it provides a mechanism for the discussion of scoring discrepancies in difficult cases.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Análise Citogenética/métodos , Bases de Dados Factuais , Internet , Microscopia/métodos , Radiometria/métodos , Sistemas de Gerenciamento de Base de Dados , Humanos , Doses de Radiação
18.
Radiat Environ Biophys ; 54(1): 81-90, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25398502

RESUMO

The lymphocyte cytokinesis-block micronucleus (CBMN) assay is a biodosemeter for the exposure to ionizing radiation. We examined the feasibility to implement a fully automated cell harvesting system for binucleate lymphocyte (BN) fixation. We compared fully automated versus manual BN fixation and evaluated its relevance on the accuracy of dose estimates using the CBMN. First, dose-response curves based on X-ray irradiated blood samples of ten healthy donors (0-4 Gy, dose rate 1.0 Gy/min) were established. BN was either prepared manually or fully automatically using the Hanabi cell harvester system PII. Slides were finally scored following an automatic or semi-automatic approach using the Metafer4 platform. The variance was calculated per dose and separately for each of the four fixation and scoring combinations. Thereafter, a serial of 16 blood samples of unknown exposure doses (0-3.9 Gy X-ray) was analyzed. Employing the four fixation and scoring combinations, we compared the number of dose estimates lying outside the ±0.5 Gy interval and the mean absolute difference (MAD) and examined sensitivity, specificity and accuracy of doses merged into binary dose categories of clinical significance. Irrespective of the fixation procedure, we observed at doses ≤1.0 Gy about 2-4 times higher median variances for the automated scoring procedure over the semi-automated approach (p ≤ 0.03). The lowest median variance was observed for automatic fixation + semi-automated scoring (135) which was even 2 times lower relative to manual fixation + semi-automated scoring (276, p = 0.04). These differences became negligible after doses >1.0 Gy. For the automatic fixation procedure, we also observed a tendency toward borderline significant higher numbers of dose estimates falling into the ±0.5 Gy interval (25 %, p = 0.08) and lower MAD values (50 %, p = 0.09), which was predominantly caused by the accuracy of dose assessment >1.0 Gy. Regarding the discrimination of binary dose categories of clinical significance, we observed a good agreement of both fixation procedures. The implementation of the automatic cell harvesting system considerably reduces the workload and results in dose estimates with a tendency of being slightly more accurate as they are after a manual fixation.


Assuntos
Citocinese/efeitos da radiação , Linfócitos/efeitos da radiação , Coleta de Tecidos e Órgãos/métodos , Relação Dose-Resposta à Radiação , Humanos , Testes para Micronúcleos/métodos , Doses de Radiação
20.
Int J Radiat Biol ; 90(2): 193-202, 2014 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-24289146

RESUMO

PURPOSE: The European Union's Seventh Framework Programme-funded project 'Multi-disciplinary biodosimetric tools to manage high scale radiological casualties' (MULTIBIODOSE) has developed a multiparametric approach to radiation biodosimetry, with a particular emphasis on triage of large numbers of potentially exposed individuals following accidental exposures. In November 2012, an emergency exercise took place which tested the capabilities of the MULTIBIODOSE project partners. The exercise described here had a dual purpose: Intercomparison of (i) three biodosimetric assays, and (ii) the capabilities of the seven laboratories, with regards to provision of triage status for suspected radiation exposed individuals. MATERIALS AND METHODS: Three biological dosimetry tools - the dicentric, micronucleus and gamma-H2AX (the phosphorylated form of member X of histone H2A, in response to DNA double-strand breaks) foci assays - were tested, in addition to provision of the triage status results (low exposure: < 1 Gy; medium exposure: 1-2 Gy; high exposure: > 2 Gy) by the MULTIBIODOSE software. The exercise was run in two modes: An initial triage categorisation of samples (based on the first dose estimates for each assay received from each laboratory) followed by collation of the full set of estimated doses (all the results from all modes of each assay carried out by the participating laboratories) calculated using as many modes of operation as possible of the different assays developed during the project. Simulated acute whole body and partial body exposures were included. RESULTS: The results of the initial triage categorisation and the full comparison of assays and methods within and between laboratories are presented here. CONCLUSIONS: The data demonstrate that the MULTIBIODOSE approach of applying multiparametric tools to radiation emergencies is valid and effective.


Assuntos
Radiometria , Triagem , Histonas/análise , Humanos , Laboratórios , Testes para Micronúcleos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...