Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Semin Arthritis Rheum ; 44(3): 345-52, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25077842

RESUMO

OBJECTIVE: Rheumatoid arthritis, and to a lesser extent ankylosing spondylitis and psoriatic arthritis, associates with increased morbidity and mortality due to cardiovascular complications. We hypothesized that the increased risk of cardiovascular disease is reflected by changes in blood parameters that are compatible with a prothrombotic propensity. To substantiate this notion, we performed an extensive literature search identifying such parameters. METHODS: A search through PubMed (1970-2013) was done to find primary articles with the following search terms: rheumatoid arthritis, ankylosing spondylitis, psoriatic arthritis or synovial fluid. These were combined with keywords reflecting processes of atherothrombosis: atherosclerosis, cardiovascular disease, coagulation, endothelial, fibrinolysis, mean platelet volume, microparticle, platelet, platelet count and mass, thrombosis, and thrombus. RESULTS: The published studies point to a multitude of blood-related processes that can contribute to a prothrombotic propensity in chronic inflammatory diseases. These include an increase in platelet mass; low-level platelet activation, enforced by interaction with leukocytes and the formation of proinflammatory cytokines; a locally activated endothelium; and an increased coagulant activity. Patient treatment with methotrexate or TNF-α blockers appears to result in normalization of several of these prothrombotic parameters. CONCLUSION: This analysis provides a first identification of the mechanisms by which inflammatory arthritis can aggravate cardiovascular disease.


Assuntos
Artrite/sangue , Artrite/complicações , Doenças Cardiovasculares/epidemiologia , Trombose/epidemiologia , Artrite/fisiopatologia , Coagulação Sanguínea/fisiologia , Doenças Cardiovasculares/fisiopatologia , Humanos , Volume Plaquetário Médio , Ativação Plaquetária/fisiologia , Contagem de Plaquetas , Fatores de Risco , Trombose/fisiopatologia
2.
J Oral Maxillofac Surg ; 70(10): 2264-70, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22705219

RESUMO

PURPOSE: To measure sensory disturbances of the inferior alveolar nerve (IAN) after removal of impacted mandibular third molars using cone beam computed tomography (CBCT) and dental panoramic radiography (PAN) for preoperative assessment in a randomized controlled trial and to measure the efficacy of the observers' prediction of IAN exposure at surgery based on CBCT compared with PAN. MATERIALS AND METHODS: The sample consisted of 86 impacted third molars (from 79 consecutive patients) in close relation to the IAN as determined by PAN and judged as showing a "moderate" risk of IAN damage. Cases presenting with no close relation between the IAN and roots and extremely risky cases with an obvious interrelation were excluded. Potential neurosensory disturbances of the lip and chin were assessed before surgery and during the postoperative recall by measuring the function of the IAN with the light-touch sensation method. RESULTS: Postoperative sensory disturbances occurred in 1 patient in the CBCT group and 1 patient in the PAN group. The light-touch sensation test showed no significant differences at the lip (P = .10) and chin (P = .17) levels for CBCT- versus PAN-based surgery. Significant differences in making a correct diagnosis of neurovascular bundle exposure at the extraction of impacted teeth were found between the 2 modalities (P = .029). CONCLUSIONS: Within the limits of the present pilot study, CBCT was not superior to PAN in predicting postoperative sensory disturbances but was superior in predicting IAN exposure during third molar removal in cases judged as having "moderate" risk.


Assuntos
Tomografia Computadorizada de Feixe Cônico/métodos , Nervo Mandibular/diagnóstico por imagem , Dente Serotino/cirurgia , Radiografia Panorâmica/métodos , Distúrbios Somatossensoriais/etiologia , Dente Impactado/cirurgia , Traumatismos do Nervo Trigêmeo/etiologia , Queixo/inervação , Seguimentos , Previsões , Humanos , Lábio/inervação , Nervo Mandibular/patologia , Dente Serotino/diagnóstico por imagem , Dente Serotino/inervação , Planejamento de Assistência ao Paciente , Projetos Piloto , Complicações Pós-Operatórias , Radiografia Dentária Digital/métodos , Medição de Risco , Limiar Sensorial/fisiologia , Extração Dentária/efeitos adversos , Alvéolo Dental/inervação , Alvéolo Dental/cirurgia , Dente Impactado/diagnóstico por imagem , Tato/fisiologia , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-22727102

RESUMO

OBJECTIVE: The purpose was to evaluate the perceived spatial and contrast resolution for a wide range of cone-beam computed tomography (CBCT) devices. STUDY DESIGN: A customized polymethyl methacrylate (PMMA) phantom was developed. Inserts containing a line-pair and rod pattern were used. The phantom was scanned with 13 CBCT devices and 1 multislice CT (MSCT) device using a variety of scanning protocols. The images were presented to 4 observers for scoring. RESULTS: The observer scores showed excellent agreement. A wide range was seen in image quality between CBCT exposure protocols. Compared with the average CBCT scores, the MSCT protocols scored lower for the line-pair insert but higher for the rod insert. CONCLUSIONS: CBCT devices are generally suitable for the visualization of high-contrast structures. Certain exposure protocols can be used for depicting low-contrast structures or fine details. The user should be able to select appropriate exposure protocols according to varying diagnostic requirements.


Assuntos
Tomografia Computadorizada de Feixe Cônico/instrumentação , Tomógrafos Computadorizados , Humanos , Imagens de Fantasmas , Doses de Radiação , Reprodutibilidade dos Testes
4.
Eur J Radiol ; 81(2): 267-71, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21196094

RESUMO

OBJECTIVE: To estimate the absorbed organ dose and effective dose for a wide range of cone beam computed tomography scanners, using different exposure protocols and geometries. MATERIALS AND METHODS: Two Alderson Radiation Therapy anthropomorphic phantoms were loaded with LiF detectors (TLD-100 and TLD-100 H) which were evenly distributed throughout the head and neck, covering all radiosensitive organs. Measurements were performed on 14 CBCT devices: 3D Accuitomo 170, Galileos Comfort, i-CAT Next Generation, Iluma Elite, Kodak 9000 3D, Kodak 9500, NewTom VG, NewTom VGi, Pax-Uni3D, Picasso Trio, ProMax 3D, Scanora 3D, SkyView, Veraviewepocs 3D. Effective dose was calculated using the ICRP 103 (2007) tissue weighting factors. RESULTS: Effective dose ranged between 19 and 368 µSv. The largest contributions to the effective dose were from the remainder tissues (37%), salivary glands (24%), and thyroid gland (21%). For all organs, there was a wide range of measured values apparent, due to differences in exposure factors, diameter and height of the primary beam, and positioning of the beam relative to the radiosensitive organs. CONCLUSIONS: The effective dose for different CBCT devices showed a 20-fold range. The results show that a distinction is needed between small-, medium-, and large-field CBCT scanners and protocols, as they are applied to different indication groups, the dose received being strongly related to field size. Furthermore, the dose should always be considered relative to technical and diagnostic image quality, seeing that image quality requirements also differ for patient groups. The results from the current study indicate that the optimisation of dose should be performed by an appropriate selection of exposure parameters and field size, depending on the diagnostic requirements.


Assuntos
Carga Corporal (Radioterapia) , Tomografia Computadorizada de Feixe Cônico/instrumentação , Doses de Radiação , Radiografia Dentária/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Masculino , Imagens de Fantasmas , Radiometria , Eficiência Biológica Relativa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA